Simultaneous spin-coating and solvent annealing: Manipulating the active layer morphology to a power conversion efficiency of 9.6% in polymer solar cells

Here, we developed a simultaneous spin-coating/solvent-annealing process and demonstrated morphology optimization for PTB7 based organic photovoltaics. This novel processing method enhances the edge-on crystalline content in thin films and induces the formation of weak PCBM aggregates. As a result, the efficiency of polymer solar cells increased from 9.2% to a certified high efficiency of 9.61%, owing to an enhanced short-circuit current (J sc , 18.4 mA cm –2 vs. 17. 5 mA cm –2 ) and an improved fill factor.

36 MATERIALS SCIENCE↗

Enabling liquid solvent structure analysis using hard x-ray absorption spectroscopy with a transferrable microfluidic reactor

In this study, a vacuum compatible microfluidic device, system for analysis at the liquid vacuum interface, is integrated to hard x-ray absorption spectroscopy to obtain the local structure of K 3 [Fe(CN) 6 ] in aqueous solutions with three concentrations of 0.5 M, 0.05 M, and 0.005 M. The solutions were sealed in a microchannel 500 µm wide and 300 µm deep in a portable microfluidic device. The Fe K-edge x-ray absorption spectra indicate a presence of Fe(III) in the complex in water, with an octahedral geometry coordinated with 6 C atoms in the first shell with a distance of ~1.92 Å and 6 N atoms in the second shell with a distance of ~3.10 Å. Varying the concentration has no observable influence on the structure of K 3 [Fe(CN) 6 ]. Our results demonstrate the feasibility of using microfluidic based liquid cells in large synchrotron facilities. Using portable microfludic reactors provides a viable approach to enable multifaceted measurements of liquids in the future.

25 ENERGY STORAGE↗

Subtask 2.5 – Syngas Testing of NETL's Advanced Precombustion CO2 Capture Solvent

U.S. Department of Energy (DOE) National Energy Technology Laboratory (NETL) on-site researchers have been examining and developing a novel solvent for precombustion capture that has the potential for improved performance and lower costs compared to Selexol™ and Rectisol®. In Subtask 2.5, the Energy & Environmental Research Center (EERC) conducted actual comparison tests on actual coal-derived syngas of a PEGDME (polyethylene glycol dimethyl ether) Selexol-type solvent and three other solvents provided by NETL. One was a new hybrid PEG–PDMS (poly[dimethylsiloxane]) solvent engineered by NETL. In addition, two commercially available chemicals that are projected to have good CO2 capture abilities were also selected for testing on actual coal-derived syngas. These tests were conducted in the EERC high-pressure fluid-bed gasifier (HPFBG) system utilizing an existing gas-sweetening absorption system (GSAS) to test the solvents. The four solvents tested were Solvent 1 – AGR II from Coastal Chemical Co., LLC, NETL Solvent 2 – XG-3229 Bis(methoxytriethyleneoxypropyl)hexamethyltrisiloxane, as manufactured by Gelast, Inc.; Solvent 3 – CASSH-1 (diethyl sebacate), procured from Sigma Aldrich; and Solvent 4 – TBP (tributyl phosphate), purchased from ThermoFisher Scientific. The solvents were all tested at a consistent syngas flow and composition at approximately 50 bar to make direct comparisons easier; two solvent flow rates which would bracket 90% CO2 capture; and, temperatures of 10°, 25°, 40°, and 55°C to determine the effects of temperature on CO2 uptake and CO2 to H2 selectivity. Figure E-1 shows the results for CO2 uptake and selectivity for the various solvents. These data show that the CO2 uptake for the Selexol-type solvent for the PEG-PDMS-3 and CASHH-1 solvents at higher operating temperatures around 40°C was better than the Selexol-type solvent was able to achieve at the lower operating temperature of 10°C. Selectivity of CO2 over H2 was at least as good as Selexol for the PEG-PDMS-3 solvent and even better than Selexol for the CASSH-1 solvent. The TBP solvent also displayed good CO2 uptake; however, CO2/H2 selectivity was worse than for the Selexol-type solvent. Operation of precombustion CO2 solvents at temperatures above ambient can provide a 2% process efficiency improvement along with a significant capital cost reduction since refrigeration and solvent dehydration equipment is not required. The excellent results from these tests warrant further longer-duration testing with one or both superior NETL-provided solvents to determine if longer-term exposure to any coal-derived syngas trace species may have an adverse impact on solvent performance. This project was funded through the EERC–DOE Joint Program on Research and Development for Fossil Energy-Related Resources Cooperative Agreement No. DE-FE0024233.

01 COAL, LIGNITE, AND PEAT↗

Chain conformations and phase separation in polymer solutions with varying solvent quality

Molecular dynamics simulations are used to investigate the conformations of a single polymer chain, represented by the Kremer-Grest bead-spring model, in a solution with a Lennard-Jones liquid as the solvent when the interaction strength between the polymer and solvent is varied. Results show that when the polymer-solvent interaction is unfavorable, the chain collapses as one would expect in a poor solvent. For more attractive polymer-solvent interactions, the solvent quality improves and the chain is increasingly solvated and exhibits ideal and then swollen conformations. However, as the polymer-solvent interaction strength is increased further to be more than about twice the strength of the polymer-polymer and solvent-solvent interactions, the chain exhibits an unexpected collapsing behavior. Correspondingly, for strong polymer-solvent attractions, phase separation is observed in the solutions of multiple chains. These results indicate that the solvent becomes effectively poor again at very attractive polymer-solvent interactions. Nonetheless, the mechanism of chain collapsing and phase separation in this limit differs from the case with a poor solvent rendered by unfavorable polymer-solvent interactions. In the latter, the solvent is excluded from the domain of the collapsed chains while in the former, the solvent is still present in the pervaded volume of a collapsed chain or in the polymer-rich domain that phase separates from the pure solvent. Finally, in the limit of strong polymer-solvent attractions, the solvent behaves as a glue to stick monomers together, causing a single chain to collapse and multiple chains to aggregate and phase separate.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

X-Ray Fluorescence Solvent Detection at the Substrate-Adhesive Interface

With environmental regulations limiting the use of volatile organic compounds, low-vapor pressure solvents have replaced traditional degreasing solvents for bond substrate preparation. When used to clean and prepare porous bond substrates such as phenolic composites, low vapor pressure solvents can penetrate deep into substrate pore networks and remain there for extended periods. Trapped solvents can interact with applied adhesives either prior to or during cure, potentially compromising bond properties. Currently, methods for characterizing solvent time-depth profiles in bond substrates are limited to bulk gravimetric or sectioning techniques. While sectioning techniques such as microtome allow construction of solvent depth profiles, their depth resolution and reliability are limited by substrate type. Sectioning techniques are particularly limited near the adhesive-substrate interface where depth resolution is further limited by adhesive-substrate hardness and, in the case of a partially cured adhesive, mechanical properties differences. Additionally, sectioning techniques cannot provide information about lateral solvent diffusion. Cross-section component mapping is an alternative method for measuring solvent migration in porous substrates that eliminates the issues associated with sectioning techniques. With cross-section mapping, the solvent-wiped substrate is sectioned perpendicular rather than parallel to the wiped surface, and the sectioned surface is analyzed for the solvent or solvent components of interest using a two-dimensional mapping or imaging technique. Solvent mapping can be performed using either direct or indirect methods. With a direct method, one or more solvent components are mapped using red or Raman spectroscopy together with a moveable sample stage and/or focal plane array detector. With an indirect method, an elemental "tag" not present in the substrate is added to the solvent before the substrate is wiped. Following cross sectioning, the tag element can then be mapped by its characteristic x-ray emission using either x-ray fluorescence, or electron-beam energy-and wavelength-dispersive x-ray spectrometry. The direct mapping techniques avoid issues of different diffusion or migration rates of solvents and elemental tags, while the indirect techniques avoid spectral resolution issues in cases where solvents and substrates have adjacent or overlapping peaks. In this study, cross-section component indirect mapping is being evaluated as a method for measuring migration of d-limonene based solvents in glass-cloth phenolic composite (GCP) prior to and during subsequent bonding and epoxy adhesive cure.