Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SMALL INTESTINE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

SU-E-T-300: Dosimetric Comparision of 4D Radiation Therapy and 3D Radiation Therapy for the Liver Tumor Based On 4D Medical Image

Purpose: The purpose of this work was to determine the dosimetric benefit to normal tissues by tracking liver tumor dose in four dimensional radiation therapy (4DRT) on ten phases of four dimensional computer tomagraphy(4DCT) images. Methods: Target tracking each phase with the beam aperture for ten liver cancer patients were converted to cumulative plan and compared to the 3D plan with a merged target volume based on 4DCT image in radiation treatment planning system (TPS). The change in normal tissue dose was evaluated in the plan by using the parameters V5, V10, V15, V20,V25, V30, V35 and V40 (volumes receiving 5, 10, 15, 20, 25, 30, 35 and 40Gy, respectively) in the dose-volume histogram for the liver; mean dose for the following structures: liver, left kidney and right kidney; and maximum dose for the following structures: bowel, duodenum, esophagus, stomach and heart. Results: There was significant difference between 4D PTV(average 115.71cm3 )and ITV(169.86 cm3). When the planning objective is 95% volume of PTV covered by the prescription dose, the mean dose for the liver, left kidney and right kidney have an average decrease 23.13%, 49.51%, and 54.38%, respectively. The maximum dose for bowel, duodenum,esophagus, stomach and heart have an average decrease 16.77%, 28.07%, 24.28%, 4.89%, and 4.45%, respectively. Compared to 3D RT, radiation volume for the liver V5, V10, V15, V20, V25, V30, V35 and V40 by using the 4D plans have a significant decrease(P≤0.05). Conclusion: The 4D plan method creates plans that permit better sparing of the normal structures than the commonly used ITV method, which delivers the same dosimetric effects to the target.

60 APPLIED LIFE SCIENCES↗

Endoluminal ultrasound applicators for MR-guided thermal ablation of pancreatic tumors: Preliminary design and evaluation in a porcine pancreas model

Purpose: Endoluminal ultrasound may serve as a minimally invasive option for delivering thermal ablation to pancreatic tumors adjacent to the stomach or duodenum. The objective of this study was to explore the basic feasibility of this treatment strategy through the design, characterization, and evaluation of proof-of-concept endoluminal ultrasound applicators capable of placement in the gastrointestinal (GI) lumen for volumetric pancreas ablation under MR guidance. Methods: Two variants of the endoluminal applicator, each containing a distinct array of two independently powered transducers (10 × 10 mm 3.2 MHz planar; or 8 × 10 × 20 mm radius of curvature 3.3 MHz curvilinear geometries) at the distal end of a meter long flexible catheter assembly, were designed and fabricated. Transducers and circulatory water flow for acoustic coupling and luminal cooling were contained by a low-profile polyester balloon covering the transducer assembly fixture. Each applicator incorporated miniature spiral MR coils and mechanical features (guiding tips and hinges) to facilitate tracking and insertion through the GI tract under MRI guidance. Acoustic characterization of each device was performed using radiation force balance and hydrophone measurements. Device delivery into the upper GI tract, adjacent to the pancreas, and heating characteristics for treatment of pancreatic tissue were evaluated in MR-guided ex vivo and in vivo porcine experiments. MR guidance was utilized for anatomical target identification, tracking/positioning of the applicator, and MR temperature imaging (MRTI) for PRF-based multislice thermometry, implemented in the real-time RTHawk software environment. Results: Force balance and hydrophone measurements indicated efficiencies of 48.8% and 47.8% and −3 dB intensity beam-widths of 3.2 and 1.2 mm for the planar and curvilinear transducers, respectively. Ex vivo studies on whole-porcine carcasses revealed capabilities of producing ablative temperature rise (ΔT > 15 °C) contours in pancreatic tissue 4–40 mm long and 4–28 mm wide for the planar transducer applicator (1–13 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Curvilinear transducers produced more selective heating, with a narrower ΔT > 15 °C contour length and width of up to 1–24 mm and 2–7 mm, respectively (1–7 min sonication duration, ∼4 W/cm{sup 2} applied acoustic intensity). Active tracking of the miniature spiral coils was achieved using a Hadamard encoding tracking sequence, enabling real-time determination of each coil’s coordinates and automated prescription of imaging planes for thermometry. In vivo MRTI-guided heating trials in three pigs demonstrated capability of ∼20 °C temperature elevation in pancreatic tissue at 2 cm depths from the applicator, with 5–7 W/cm{sup 2} applied intensity and 6–16 min sonication duration. Dimensions of thermal lesions in the pancreas ranged from 12 to 28 mm, 3 to 10 mm, and 5 to 10 mm in length, width, and depth, respectively, as verified through histological analysis of tissue sections. Multiple-baseline reconstruction and respiratory-gated acquisition were demonstrated to be effective strategies in suppressing motion artifacts for clear evolution of temperature profiles during MRTI in the in vivo studies. Conclusions: This study demonstrates the technical feasibility of generating volumetric ablation in pancreatic tissue using endoluminal ultrasound applicators positioned in the stomach lumen. MR guidance facilitates target identification, device tracking/positioning, and treatment monitoring through real-time multislice PRF-based thermometry.

60 APPLIED LIFE SCIENCES↗

SU-D-BRA-06: Duodenal Interfraction Motion with Abdominal Compression

Purpose: To quantify the effect of abdominal compression on duodenal motion during pancreatic radiotherapy. Methods: Seven patients treated for pancreatic cancer were selected for analysis. Four patients were treated with abdominal compression and three without. The duodenum was contoured by the same physician on each CBCT (five CBCTs for patients with compression, four for non-compression patients). CBCTs were rigidly registered using a soft tissue match and contours were copied to the delivered plans which were all radical (BED > 50 Gy). The distance between the duodenum on the planning CT and each CBCT was quantified by calculating the root mean square (RMS) distance. The DVHs of each abdominal compression patient was converted to an EQD2 DVH (alpha/beta = 10) using an in-house tool and volumes receiving at least 25, 35, 45, and 50 Gy were recorded. Results: The maximum variation in duodenal volumes on the CBCTs for the four abdominal compression patients were 19.1 cm{sup 3} (32.8%), 19.1 cm{sup 3} (20.6%), 19.9 cm{sup 3} (14.3%), and 12.9 cm{sup 3} (27.3%) compared to 15.2 cm{sup 3} (17.6%), 34.7 cm{sup 3} (83.4%), and 56 cm{sup 3} (60.2%) for non-compression patients. The average RMS distance between the duodenum on the planning CT and each CBCT for all abdominal compression patients was 0.3 cm compared to 0.7 cm for non-compressed patients. The largest (and average) difference between the planning CT and CBCTs in volume of duodenum receiving more than 25, 35, 45 and 50 Gy for abdominal compression patients was 11% (5%), 9% (3%), 9% (2%), and 6% (1%). Conclusion: Abdominal compression reduces variation in volume and absolute position of the duodenum throughout treatment. This is seen as an improvement but does not eliminate the need to consider dosimetric effects of motion. Abdominal compression is particularly useful in SBRT when only a few fractions are delivered. Alon Witztum is supported by an MRC/Gray Institute DPhil Studentship. Daniel Holyoake is supported by a CRUK/Nuffield Clinical Research Fellowship. Sam Warren and Mike Partridge are supported by CRUK grant C5255/A15935. Maria Hawkins received an MRC Fellowship MC-PC-12001/2.

60 APPLIED LIFE SCIENCES↗

SU-F-J-173: Online Replanning for Dose Painting Based On Changing ADC Map of Pancreas Cancer

Purpose: The introduction of MR-guided radiation therapy (RT), e.g., MR-Linac, would allow dose painting to adapt spatial RT response revealed from MRI data during the RT delivery. The purpose of this study is to investigate the use of an online replanning method to adapt dose painting from the MRI Apparent Diffusion Coefficient (ADC) map acquired during the delivery of RT for pancreatic cancers. Methods: Original dose painting plans were created based on multi-parametric simulation MRI including T1, T2 and ADC, using a treatment planning system (MONACO, Elekta) equipped with an online replanning algorithm (WSO, warm start optimization). Multiple GTVs, identified based on various ADC levels were prescribed to different doses ranging from 50–70 Gy with simultaneous integrated boost in 28 fractions. The MRI acquired after RT were used to mimic weekly MRI, on which the changing GTVs, pancreatic head and other organs-at-risk (OAR) (duodenum, stomach, small bowel) were delineated. The adaptive plan was generated by applying WSO algorithm starting from the deformed original plan based on the weekly MRI using a deformable image registration (DIR) software (ADMIRE, Elekta). The online replanning method takes <10 min. including DIR, target delineation, WSO execution and final dose calculation. Standard IGRT repositioning and full-blown reoptimization plans were also generated to compare with the adaptive plans. Results: The online replanning method significantly improved the multiple target coverages and OAR sparing for pancreatic cancers. For example, for a case with two GTVs with prescriptions of 60 and 70 Gy in pancreatic head, V100-GTV70 (the volume covered by 100% of prescription dose for GTV with 70 Gy)/V100-GTV60/V100-CTV50/V45-duodenum were (95.1/22.2/69.5/85.7), (95.0/97.0/98.6/34.3), and (95.0/98.1/100.0/38.7) for the IGRT, adaptive and reoptimization plans, respectively. Conclusion: The introduced online adaptive replanning method can effectively account for interfractional changes including tumor spatial response during MR-guided RT delivery, allowing precise delivery of dose painting. This study was partially supported by Elekta Inc.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRA-11: Indications for Online Adaptive Radiotherapy Based On Dosimetric Consequences of Interfractional Pancreas-To-Duodenum Motion in MRI-Guided Pancreatic Radiotherapy

Purpose: Dose limiting structures, such as the duodenum, render the treatment of pancreatic cancer challenging. In this multi-institutional study, we assess dosimetric differences caused by interfraction pancreas-to-duodenum motion using MR-IGRT to determine the potential impact of adaptive replanning. Methods: Ten patients from two institutions undergoing MRI-guided radiotherapy with conventional fractionation (n=5) or SBRT (n=5) for pancreatic cancer were included. Initial plans were limited by duodenal dose constraints of 50 Gy (0.5 cc)/31 Gy (0.1 cc) for conventional/SBRT with prescriptions of 30 Gy/5 fractions (SBRT) and 40–50 Gy/25 fractions (conventional). Daily volumetric MR images were acquired under treatment conditions on a clinical MR-IGRT system. The correlation was assessed between interfractional GTV-to-duodenum positional variation and daily recalculations of duodenal dose metrics. Positional variation was quantified as the interfraction difference in Hausdorff distance from simulation baseline (ΔHD) between the GTV and proximal duodenal surface, or volume overlap between GTV and duodenum for cases with HD{sub 0}=0 (GTV abutting duodenum). Adaptation was considered indicated when daily positional variations enabled dose escalation to the target while maintaining duodenal constraints. Results: For fractions with ΔHD>0 (n=14, SBRT only), the mean interfraction duodenum dose decrease from simulation to treatment was 44±53 cGy (maximum 136 cGy). A correlation was found between ΔHD and dosimetric difference (R{sup 2}=0.82). No correlation was found between volume of overlap and dosimetric difference (R{sup 2}=0.31). For 89% of fractions, the duodenum remained overlapped with the target and the duodenal dose difference was negligible. The maximum observed indication for adaptation was for interfraction ΔHD=11.6 mm with potential for adaptive dose escalation of 136 cGy. Conclusion: This assessment showed that Hausdorff distance was a reasonable metric to use to determine the indication for adaptation. Adaptation was potentially indicated in 11% of the treatments (fractions where GTV-to-duodenum distance increased from simulation), with a feasible average dose escalation of 7.0%. MB, LH, JO, RK, PP: research and/or travel funding from ViewRay Inc. PP: research grant from Varian Medical Systems and Philips Healthcare.

60 APPLIED LIFE SCIENCES↗

WE-AB-207B-01: Dose Tolerance for SBRT/SABR

Purpose: Stereotactic body radiation therapy (SBRT) / stereotactic ablative body radiotherapy (SABR) is gaining popularity, but quantitative dose tolerance has still been lacking. To improve this, the April 2016 issue of Seminars in Radiation Oncology will have normal tissue complication probability (NTCP) models for 10 critical structures: optic pathway, cochlea, oral mucosa, esophagus, chestwall, aorta, bronchi, duodenum, small bowel, and spinal cord. Methods: The project included more than 1500 treatments in 1–5 fractions using CyberKnife, Gamma Knife, or LINAC, with 60 authors from 15 institutions. NTCP models were constructed from the 97 grade 2–3 complications, predominantly scored using the common terminology criteria for adverse events (CTCAEv4). Dose volume histogram (DVH) data from each institutional dataset was loaded into the DVH Evaluator software (DiversiLabs, LLC, Huntingdon Valley, Pa) for modeling. The current state of the literature for the critical structures was depicted using DVH Risk Maps: comparative graphs of dose tolerance limits that can include estimated risk levels, reported complications, DVH data for study patients, as well as high- and low-risk dose tolerance limits. Results: For relatively acceptable toxicity like grade 1–3 rib fractures and chestwall pain, the high-risk limits have 50% risk and the low-risk limits have 5% risk. Emami et al (IJROBP 1991 May 15;21(1):109–22) used 50% and 5% risk levels for all structures, whereas this effort used clinically acceptable ranges for each: in structures like aorta or spinal cord where complications must be avoided, the high- and low-risk limits have about 3% and 1% risk, respectively, in this issue of Seminars. These statistically based guidelines can help ensure plan quality for each patient. Conclusion: NTCP for SBRT is now becoming available. Hypofractionated dose tolerance can be dramatically different than extrapolations of conventional fractionation so NTCP analysis of the SBRT/SBRT data is important to ensure safe clinical practice. Dr. Grimm, designed and holds intellectual property rights to the DVH Evaluator software tool which is an FDA-cleared product in commercial use, and was used to analyze the data.

60 APPLIED LIFE SCIENCES↗

Modeling Sepsis: Establishment and Validation of a 72-Hour Swine Model of Penetrating Abdominal Trauma

Background/Objectives: Fecal peritonitis following penetrating abdominal trauma is a serious condition that often results in sepsis and organ failure. The aim of our study was to develop a novel conscious porcine model of sepsis and organ dysfunction caused by multiple penetrating injuries to the small and large intestines. Methods: Twelve female Yorkshire pigs (average weight 50.6 ± 6.5 kg) were divided into two groups: Penetrating Abdominal Trauma (PAT) (n = 8) and Control (n = 4). All surgical procedures were performed under anesthesia with adequate analgesia. In the PAT group, the small and large intestines were punctured, and feces mixed with saline were introduced into the abdominal cavity to induce peritonitis. The Control group received sham surgery with only saline solution. The animals were observed in a conscious state over a period of 72 h, vital parameters were recorded, and blood samples were taken regularly. We adapted a pig-specific SOFA score and developed pig-specific SIRS criteria and NEWS2 score to assess organ function. The model was validated by independent investigators. Results: The survival rate in the PAT group was 75%, with an average survival time of 58.5 h, while all animals in the Control group survived to euthanasia. Monitoring showed pathophysiological changes, such as tachycardia, leucopenia, and thrombocytopenia, indicative of sepsis and organ dysfunction. Blinded investigators independently confirmed the model’s validity. Conclusions: A new swine model of penetrating abdominal trauma and sepsis has been successfully developed that demonstrates significant physiological and immunologic changes comparable to human sepsis. This new model provides a realistic platform for future research into sepsis, its diagnostics, and the evaluation of therapeutic strategies.

General & Internal Medicine↗

Mapping O 2 concentration in ex-vivo tissue samples on a fast PLIM macro-imager

O 2 PLIM microscopy was employed in various studies, however current platforms have limitations in sensitivity, image acquisition speed, accuracy and general usability. We describe a new PLIM imager based on the Timepix3 camera (Tpx3cam) and its application for imaging of O 2 concentration in various tissue samples stained with a nanoparticle based probe, NanO 2 -IR. Upon passive staining of mouse brain, lung or intestinal tissue surface with minute quantities of NanO 2 -IR or by microinjecting the probe into the lumen of small or large intestine fragments, robust phosphorescence intensity and lifetime signals were produced, which allow mapping of O 2 in the tissue within 20 s. Inhibition of tissue respiration or limitation of O 2 diffusion to tissue produced the anticipated increases or decreases in O 2 levels, respectively. The difference in O 2 concentration between the colonic lumen and air-exposed serosal surface was around 140 µM. Furthermore, subcutaneous injection of 5 µg of the probe in intact organs (a paw or tail of sacrificed mice) enabled efficient O 2 imaging at tissue depths of up to 0.5 mm. Overall, the PLIM imager holds promise for metabolic imaging studies with various ex vivo models of animal tissue, and also for use in live animals.

59 BASIC BIOLOGICAL SCIENCES↗

A New Class of Molecular Targeted Radioprotectors: GSK-3beta Inhibitors

Purpose: Development of new treatments is critical to effective protection against radiation-induced injury. We investigate the potential of developing small-molecule inhibitors of glycogen synthase kinase 3beta (GSK-3beta)-SB216763 or SB415286-as radioprotective agents to attenuate intestinal injury. Methods and Materials: A survival study was done by use of C57BL/6J mice to evaluate the radioprotective effect of GSK-3beta inhibitors. Terminal deoxynucleotidyl transferase dUTP nick end labelling (TUNEL) assay and immunohistochemical staining for Bax and Bcl-2 were used to assess apoptosis in the small intestines of the treated mice. A clonogenic survival study, apoptosis assays (staining with annexin V or 4',6-diamidino-2-phenylindole), and immunoblot analysis of beta-catenin, Bcl-2, Bax, and caspase 3 were done by use of Rat intestinal epithelial cell line IEC-6 cells. Results: Pretreatment with SB415286 significantly improved survival of mice irradiated with 8 and 12 Gy. Mice pretreated with SB216763 or SB415286 showed a significant reduction in TUNEL- and Bax-positive cells and an increase in Bcl-2-positive cells in intestinal crypts at 4 and/or 12 h after radiation with 4 and/or 8 Gy compared with radiation alone. Pretreatment of irradiated IEC-6 cells with GSK-3beta inhibitors significantly increased clonogenic survival compared with cells treated with radiation alone. This increase was due to the attenuation of radiation-induced apoptosis, as shown by annexin V and 4',6-diamidino-2-phenylindole assays, as well as immunoblot analysis of Bcl-2, Bax, and caspase 3. Conclusions: Glycogen synthase kinase 3beta small-molecule inhibitors protect mouse intestine from radiation-induced damage in cell culture and in vivo and improve survival of mice. Molecular mechanisms of this protection involve attenuated radiation-induced apoptosis regulated by Bcl-2, Bax, and caspase 3. Therefore GSK-3beta inhibitors reduce deleterious consequences of intestinal irradiation and thereby improve quality of life during radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Defining cell culture conditions to improve human norovirus infectivity assays

Significant difficulties remain for determining whether human noroviruses (hNoV) recovered from water, food, and environmental samples are infectious. Three-dimensional tissue culture of human intestinal cells has shown promise in developing an infectivity assay, but reproducibility, even within a single laboratory, remains problematic. From the literature and our observations, we hypothesized that the common factors that leads to more reproducible hNoV infectivity in vitro requires that the cell line be 1) of human gastrointestinal origin, 2) expresses apical microvilli, and 3) be a positive secretor cell line. The C 2 BBe1 cell line, which is a brush-border producing clone of Caco-2, meets these three criteria. When challenged with Genogroup II viruses, we observed a 2 Log10 increase in viral RNA titer. A passage experiment with GII viruses showed evidence of the ability to propagate hNoV by both reverse transcription quantitative PCR (qRT-PCR) and microscopy. Using 3-D C 2 BBe1 cells improves reproducibility of the infectivity assay for hNoV, but the assay can still be variable. Two sources of variability include the cells themselves (mixed phenotypes of small and large intestine) and initial titer measurements using quantitative reverse transcription PCR (qRT-PCR) that measures all RNA vs. plaque assays that measure infectious virus.

C2BBe1 cells↗

Human Dosimetry and Preliminary Tumor Distribution of (superscript)18F-Fluoropaclitaxel in Healthy Volunteers and Newly Diagnosed Breast Cancer Patients Using PET/CT

{sup 18}F-fluoropaclitaxel is a radiolabeled form of paclitaxel, a widely used chemotherapy agent. Preclinical data suggest that {sup 18}F-fluoropaclitaxel may be a reasonable surrogate for measuring the uptake of paclitaxel. As a substrate of P-glycoprotein, a drug efflux pump associated with multidrug resistance, {sup 18}F-fluoropaclitaxel may also be useful in identifying multidrug resistance and predicting tumor response for drugs other than paclitaxel. After informed consent was obtained, 3 healthy volunteers and 3 patients with untreated breast cancer (neoadjuvant chemotherapy candidates, tumor size > 2 cm) received an intravenous infusion of {sup 18}F-fluoropaclitaxel and then underwent PET/CT. Healthy volunteers underwent serial whole-body imaging over an approximately 3-h interval, and organ {sup 18}F residence times were determined from the time-activity curves uncorrected for decay to determine dosimetry. Radiation dose estimates were calculated using OLINDA/EXM software. For breast cancer patients, dynamic imaging of the primary tumor was performed for 60 min, followed by static whole-body scans at 1 and 2 h after injection. Dosimetry calculations showed that the gallbladder received the highest dose (229.50 {mu}Gy/MBq [0.849 rad/mCi]), followed by the small and large intestines (161.26 {mu}Gy/MBq [0.597 rad/mCi] and 184.59 {mu}Gy/MBq [0.683 rad/mCi]). The resultant effective dose was 28.79 {mu}Gy/MBq (0.107 rem/mCi). At approximately 1 h after injection, an average of 42% of the decay-corrected activity was in the gastrointestinal system, with a mean of 0.01% in the tumor. All 3 breast cancer patients showed retention of {sup 18}F-fluoropaclitaxel and ultimately demonstrated a complete pathologic response (no invasive cancer in the breast or axillary nodes) to chemotherapy that included a taxane (either paclitaxel or docetaxel) at surgical resection. The tumor-to-background ratio increased with time to a maximum of 7.7 at 20 min. This study demonstrates the feasibility of using {sup 18}F-fluoropaclitaxel PET/CT tumor imaging and provides radiation dosimetry measurements in humans. Although further study is needed, it is hoped that the measured intratumoral {sup 18}F-fluoropaclitaxel distribution can serve as a surrogate for paclitaxel, and potentially other chemotherapeutic agent retention, in solid tumors.

18F-Fluoropaclitaxel (FPAC)↗

Predictive Capabilities of in Vitro Assays for Estimating Pb Relative Bioavailability in Phosphate Amended Soils

In this study, the in vitro bioaccessibility (IVBA) of lead (Pb) in phosphate-amended Pb-contaminated soil was assessed using a variety of IVBA assays with an overarching aim of determining whether changes in Pb IVBA were congruent to those observed for Pb relative bioavailability (RBA) determined using an in vivo mouse assay. Here, amending soil with phosphoric acid or rock phosphate resulted in changes in Pb speciation, however, varying Pb IVBA results were obtained depending on the methodology utilized. In addition, IVBA assays influenced Pb speciation as a consequence of interactions between dissolved Pb and unreacted phosphate arising from the amendment or from assay constituents. When the relationship between Pb RBA and IVBA was assessed, a comparison of treatment effect ratios (Pb RBA or IVBA in treated soil divided by Pb RBA or IVBA for untreated soil) provided the best in vivo–in vitro correlation particular for SBRC (r 2 = 0.83) and IVG (r 2 = 0.89) intestinal extraction. For these assays, the slope of the lines of best fit were close to 1 (1.12, 0.82; SBRC, IVG intestinal extraction respectively) with small y-intercepts (0.09, 0.08 respectively) indicating that the efficacy of phosphate amendments for reducing Pb RBA may be predicted using IVBA assays.

54 ENVIRONMENTAL SCIENCES↗

Three Human Cell Types Respond to Multi-Walled Carbon Nanotubes and Titanium Dioxide Nanobelts with Cell-Specific Transcriptomic and Proteomic Expression Patterns.

The growing use of engineered nanoparticles (NPs) in commercial and medical applications raises the urgent need for tools that can predict NP toxicity. Global transcriptome and proteome analyses were conducted on three human cell types, exposed to two high aspect ratio NP types, to identify patterns of expression that might indicate high versus low NP toxicity. Three cell types representing the most common routes of human exposure to NPs, including macrophage-like (THP-1), small airway epithelial and intestinal (Caco-2/HT29-MTX) cells, were exposed to TiO2 nanobelts (TiO2-NB; high toxicity) and multi-walled carbon nanotubes (MWCNT; low toxicity) at low (10 µg/mL) and high (100 µg/mL) concentrations for 1 and 24 h. Unique patterns of gene and protein expressions were identified for each cell type, with no differentially expressed (p < 0.05, 1.5-fold change) genes or proteins overlapping across all three cell types. While unique to each cell type, the early response was primarily independent of NP type, showing similar expression patterns in response to both TiO2-NB and MWCNT. The early response might, therefore, indicate a general response to insult. In contrast, the 24 h response was unique to each NP type. The most significantly (p < 0.05) enriched biological processes in THP-1 cells indicated TiO2-NB regulation of pathways associated with inflammation, apoptosis, cell cycle arrest, DNA replication stress and genomic instability, while MWCNT-regulated pathways indicated increased cell proliferation, DNA repair and anti-apoptosis. These two distinct sets of biological pathways might, therefore, underlie cellular responses to high and low NP toxicity, respectively.

Environmental Molecular Sciences Laboratory↗

Comparison of the Effects of Iodine and Iodide on Thyroid Function in Humans

The present experiment in humans failed to confirm the differential effect of I(sub 2) on maintenance of serum T(sub 4) concentrations relative to the effects of I(-) that was observed in prior experiments in rats. The reaction of I(sub 2) with metabolites of thyroid hormones in the intestine that appears responsible for this effect in rats probably also exists at some level in humans. The present results suggest that the concentrations of such metabolites in the human intestinal tract are too small to significantly affect circulating concentration of T(sub 4). However, based on the elevations in TSH, there should be some concern over the potential impacts of chronic consumption of iodine in drinking water.

Robison, Linda M.↗

In situ detection of ferric reductase activity in the intestinal lumen of an insect

The rise of atmospheric oxygen as a result of photosynthesis in cyanobacteria and chloroplasts has transformed most environmental iron into the ferric state. In contrast, cells within organisms maintain a reducing internal milieu and utilize predominantly ferrous iron. Ferric reductases are enzymes that transfer electrons to ferric ions, either extracellularly or within endocytic vesicles, enabling cellular ferrous iron uptake through Divalent Metal Transporter 1. In mammals, duodenal cytochrome b is a ferric reductase of the intestinal epithelium, but how insects reduce and absorb dietary iron remains unknown. Here we provide indirect evidence of extracellular ferric reductase activity in a small subset of Drosophila melanogaster intestinal epithelial cells, positioned at the neck of the midgut’s anterior region. Dietary-supplemented bathophenanthroline sulphate (BPS) captures locally generated ferrous iron and precipitates into pink granules, whose chemical identity was probed combining in situ X-ray absorption near edge structure and electron paramagnetic resonance spectroscopies. An increased presence of manganese ions upon BPS feeding was also found. Control animals were fed with ferric ammonium citrate, which is accumulated into ferritin iron in distinct intestinal subregions suggesting iron trafficking between different cells inside the animal. Spectroscopic signals from the biological samples were compared to purified Drosophila and horse spleen ferritin and to chemically synthesized BPS-iron and BPS-manganese complexes. The results corroborated the presence of BPS-iron in a newly identified ferric iron reductase region of the intestine, which we propose constitutes the major site of iron absorption in this organism.

EPR↗

Retroperitoneal Sarcoma Target Volume and Organ at Risk Contour Delineation Agreement Among NRG Sarcoma Radiation Oncologists

Purpose: The purpose of this study was to evaluate the variability in target volume and organ at risk (OAR) contour delineation for retroperitoneal sarcoma (RPS) among 12 sarcoma radiation oncologists. Methods and Materials: Radiation planning computed tomography (CT) scans for 2 cases of RPS were distributed among 12 sarcoma radiation oncologists with instructions for contouring gross tumor volume (GTV), clinical target volume (CTV), high-risk CTV (HR CTV: area judged to be at high risk of resulting in positive margins after resection), and OARs: bowel bag, small bowel, colon, stomach, and duodenum. Analysis of contour agreement was performed using the simultaneous truth and performance level estimation (STAPLE) algorithm and kappa statistics. Results: Ten radiation oncologists contoured both RPS cases, 1 contoured only RPS1, and 1 contoured only RPS2 such that each case was contoured by 11 radiation oncologists. The first case (RPS 1) was a patient with a de-differentiated (DD) liposarcoma (LPS) with a predominant well-differentiated (WD) component, and the second case (RPS 2) was a patient with DD LPS made up almost entirely of a DD component. Contouring agreement for GTV and CTV contours was high. However, the agreement for HR CTVs was only moderate. For OARs, agreement for stomach, bowel bag, small bowel, and colon was high, but agreement for duodenum (distorted by tumor in one of these cases) was fair to moderate. Conclusions: For preoperative treatment of RPS, sarcoma radiation oncologists contoured GTV, CTV, and most OARs with a high level of agreement. HR CTV contours were more variable. Further clarification of this volume with the help of sarcoma surgical oncologists is necessary to reach consensus. More attention to delineation of the duodenum is also needed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗