Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SIGNAL NOISE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Post-embedding tem signal-to-noise ratio of S-100

We assessed the reactivity of purified S-100 antiserum in immuno-electron microscopy by counting the number of gold particles per microns 2 over inner ear tissues embedded in different media. Sections containing predominantly Schwann's cell cytoplasm and nucleus, afferent fiber axoplasm and myelin sheath of chick cochleae were reacted with anti-S-100 IgG, an antibody to a calcium binding protein of neuronal tissues, then labeled with anti-IgG-gold conjugate. This investigation was conducted because previously published procedures, unmodified, did not yield acceptable results. Preparation of all specimens was identical. Only the medium (PolyBed 812, Araldite or Spurr epoxies; and LR White, LR Gold or Lowicryl plastics) was changed. The medium was made the changing variable because antigens available in post-embedding immuno-electron microscopy are decreased by heat, either used and/or released during polymerization of the embedding medium. The results indicate that: (a) none of the embedding media above provided optimal signal-to-noise ratio for all parts of the nerve stained in the same section; (b) aggregation of gold particles over cells was highest in embedding media with high background labeling over areas devoid of tissue (noise); (c) aggregation occurred randomly throughout both cellular and acellular regions; and (d) particles aggregated less and were distributed more evenly in tissues from media yielding good ultrastructural integrity.

Non-NASA Center↗

Signal processing method and system for noise removal and signal extraction

A signal processing method and system combining smooth level wavelet pre-processing together with artificial neural networks all in the wavelet domain for signal denoising and extraction. Upon receiving a signal corrupted with noise, an n-level decomposition of the signal is performed using a discrete wavelet transform to produce a smooth component and a rough component for each decomposition level. The n.sup.th level smooth component is then inputted into a corresponding neural network pre-trained to filter out noise in that component by pattern recognition in the wavelet domain. Additional rough components, beginning at the highest level, may also be retained and inputted into corresponding neural networks pre-trained to filter out noise in those components also by pattern recognition in the wavelet domain. In any case, an inverse discrete wavelet transform is performed on the combined output from all the neural networks to recover a clean signal back in the time domain.

47 OTHER INSTRUMENTATION↗

The discrete noise of magnons

We report experimental results, which show that the low-frequency noise of magnonic devices is dominated by the random telegraph signal noise rather than 1/$f$ noise—a striking contrast to many electronic devices ($f$ is a frequency). It was also found that the noise level of surface magnons depends strongly on the power level, increasing sharply at the on-set of nonlinear dissipation. The presence of the random telegraph signal noise suggests that the current fluctuations involve random discrete macro events caused by an individual macro-scale fluctuator. We anticipate that our results will help in developing the next generation of magnonic devices for information processing and sensing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Measurement of neutron and gamma-ray noise in large subcritical condition for criticality safety - 14485

Various experimental methods have been proposed for subcriticality measurement and neutron noise analysis method is one of important experimental techniques for this purpose. The variance to mean value method, called Feynman-alpha method, is one of well-known noise analysis methods. In this method, variation of neutron count rate distribution from the Poisson distribution caused by fission chain reactions, which is called Y-value, is measured, however, it is difficult to measure the Y-value in large subcritical state such as nuclear fuel facility, because number of emitted neutrons by fission chain reaction is small, which causes large statistical error. We developed new experimental technique based on Feynman-alpha method combined with pulsed neutron source, called Delayed Neutron Noise Analysis (DNNA) method, to monitor the change of subcriticality. In this new method, neutron and gamma-ray counts measured only appeared in the delayed neutron region after injection of pulsed neutron are analyzed, and the prompt neutron region is completely ignored. The advantage of DNNA compared with conventional method is that spatial dependency of detector positions on measured results can be greatly decreased, which result in increase of accuracy of measured subcriticality. The validity of the DNNA method was experimentally investigated in the Kyoto University Critical Assembly (KUCA) at Kyoto University Research Reactor Institute. In the experiments, pulsed neutrons by D-T reactions are injected into the core and we used {sup 3}He detectors to measure neutron noise signals and BGO scintillation detectors to measure gamma-ray noise signals, and all data in the delayed neutron region were analyzed based on Feynman-alpha method. From the experimental results, it was found that the Y-values are clearly larger than zero in the case of existence of fuel assemblies and this method can be applied to detection of hidden special nuclear materials for example in a cargo container. (authors)

42 ENGINEERING↗

Signal-to-noise assessment for diffusion tensor imaging with single data set and validation using a difference image method with data from a multicenter study

Purpose: To describe a quantitative method for determination of SNR that extracts the local noise level using a single diffusion data set. Methods: Brain data sets came from a multicenter study (eight sites; three MR vendors). Data acquisition protocol required b = 0, 700 s/mm{sup 2}, fov = 256 × 256 mm{sup 2}, acquisition matrix size 128 × 128, reconstruction matrix size 256 × 256; 30 gradient encoding directions and voxel size 2 × 2 × 2 mm{sup 3}. Regions-of-interest (ROI) were placed manually on the b = 0 image volume on transverse slices, and signal was recorded as the mean value of the ROI. The noise level from the ROI was evaluated using Fourier Transform based Butterworth high-pass filtering. Patients were divided into two groups, one for filter parameter optimization (N = 17) and one for validation (N = 10). Six white matter areas (the genu and splenium of corpus callosum, right and left centrum semiovale, right and left anterior corona radiata) were analyzed. The Bland–Altman method was used to compare the resulting SNR with that from the difference image method. The filter parameters were optimized for each brain area, and a set of “global” parameters was also obtained, which represent an average of all regions. Results: The Bland–Altman analysis on the validation group using “global” filter parameters revealed that the 95% limits of agreement of percent bias between the SNR obtained with the new and the reference methods were −15.5% (median of the lower limit, range [−24.1%, −8.9%]) and 14.5% (median of the higher limits, range [12.7%, 18.0%]) for the 6 brain areas. Conclusions: An FT-based high-pass filtering method can be used for local area SNR assessment using only one DTI data set. This method could be used to evaluate SNR for patient studies in a multicenter setting.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Adaptive Noise Suppression Using Digital Signal Processing

A signal to noise ratio dependent adaptive spectral subtraction algorithm is developed to eliminate noise from noise corrupted speech signals. The algorithm determines the signal to noise ratio and adjusts the spectral subtraction proportion appropriately. After spectra subtraction low amplitude signals are squelched. A single microphone is used to obtain both eh noise corrupted speech and the average noise estimate. This is done by determining if the frame of data being sampled is a voiced or unvoiced frame. During unvoice frames an estimate of the noise is obtained. A running average of the noise is used to approximate the expected value of the noise. Applications include the emergency egress vehicle and the crawler transporter.

Kozel, David↗

Towards a practical Johnson noise thermometer for long-term measurements in harsh environments

The impact of mechanical and chemical changes in conventional sensors such as thermocouples and resistance thermometers can be avoided by instead using temperature sensors based on fundamental thermometry. A prime example of this is Johnson noise thermometry, which is based on measurement of the fluctuations in the voltage of a resistor arising from thermal motion of charge carriers - i.e. the 'Johnson noise'. A Johnson noise thermometer never needs calibration and is insensitive to the condition of the sensor material. It is therefore ideally suited to long-term temperature measurements in harsh environments, such as nuclear reactor coolant circuits, in-pile measurements, nuclear waste management and storage, and severe accident monitoring. There have been a number of previous attempts to develop a Johnson noise thermometer for the nuclear industry, but none have reached commercial exploitation because of technical problems in practical implementation. The main challenge is to extract the tiny Johnson noise signal from ambient electrical noise influences, both from the internal amplification electronics, and from external electrical noise sources. Recent advances in electronics technology and digital signal processing techniques have opened up new possibilities for developing a viable, practical Johnson noise thermometer. We describe a project funded by the UK Technology Strategy Board (now Innovate UK) 'Developing the nuclear supply chain' call, currently underway, to develop a practical Johnson noise thermometer that makes use of innovative electronics for ultralow noise amplification and signal processing. The new electronics technology has the potential to help overcome the problems encountered with previous attempts at constructing a practical Johnson noise thermometer. An outline of the new developments is presented, together with an overview of the current status of the project. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear spin noise in NMR revisited

The theoretical shapes of nuclear spin-noise spectra in NMR are derived by considering a receiver circuit with finite preamplifier input impedance and a transmission line between the preamplifier and the probe. Using this model, it becomes possible to reproduce all observed experimental features: variation of the NMR resonance linewidth as a function of the transmission line phase, nuclear spin-noise signals appearing as a “bump” or as a “dip” superimposed on the average electronic noise level even for a spin system and probe at the same temperature, pure in-phase Lorentzian spin-noise signals exhibiting non-vanishing frequency shifts. Extensive comparisons to experimental measurements validate the model predictions, and define the conditions for obtaining pure in-phase Lorentzian-shape nuclear spin noise with a vanishing frequency shift, in other words, the conditions for simultaneously obtaining the spin-noise and frequency-shift tuning optima.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

NOISE AND SIGNAL FOR SPECTRA OF INTERMITTENT NOISELIKE EMISSION

We show that intermittency of noiselike emission, after propagation through a scattering medium, affects the distribution of noise in the observed correlation function. Intermittency also affects correlation of noise among channels of the spectrum, but leaves the average spectrum, average correlation function, and distribution of noise among channels of the spectrum unchanged. Pulsars are examples of such sources: intermittent and affected by interstellar propagation. We assume that the source emits Gaussian white noise, modulated by a time envelope. Propagation convolves the resulting time series with an impulse-response function that represents effects of dispersion, scattering, and absorption. We assume that this propagation kernel is shorter than the time for an observer to accumulate a single spectrum. We show that rapidly varying intermittent emission tends to concentrate noise near the central lag of the correlation function. We derive mathematical expressions for this effect, in terms of the time envelope and the propagation kernel. We present examples, discuss effects of background noise, and compare our results with observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Pulse-code-modulation baseline correction for low signal-to-noise ratios

Time-shared integrate-hold-dump circuits separate the dc level due to the signal /bit information/ from the dc signal due to the baseline error. The system detects the baseline error, filters it, and then algebraically adds enough voltage to a servo loop to reduce the error to zero.

Stephens, T. J.↗

Transcriptomics-based Machine Learning Analysis Predicts Space-Exposed Murine Livers

Limited sample sizes, high data dimensionality, and sensitivity to technical and biological variability of next generation sequencing (NGS), has typically limited machine learning (ML) in space studies and further study of radiation effects. However, pooling smaller studies while addressing intra- and inter-study variabilities allows for ML predictive modeling. Here, integration methods were applied to whole transcriptome shotgun sequencing (RNAseq) data from 6 mouse liver GeneLab datasets (GLDS) with a total of 113 spaceflight and ground-control samples to determine top features relevant to spaceflight including the effect of radiation exposure. Data was normalized within each study, then merged and scaled across all datasets. Data dimensionality was reduced using a minimum redundancy maximum relevance (MRMR) methodology. The top MRMR features were used to predict spaceflight vs. ground-control samples using a Random Forest (RF) classifier with 5-fold cross validation (CV). The ML-based gene sets were further compared against differential gene expression results from individual GLDS. CV training using the top 100 MRMR genes show averages of 86% accuracy and 0.95 AUC value on the validation set over 5 folds (Figure 1A). Baseline set analysis on differentially expressed genes (DEGs) identified using padj ≤ 0.05 show 811 or 68 DEGs overlapping between at least 2 or 3 studies, respectively (Figure 1B). Over-representation analysis showed overlapping biological processes related to fatty acid and lipid metabolism. Set analysis between the MRMR features and the DEGs showed 60 or 8 genes overlapping with at least 1 or 2 studies, respectively. MRMR feature selection and ensemble ML methods (e.g. RF) improve performance relative to a Naïve Bayes classifier when NGS data sets are analyzed. A challenge of applying ML methods across heterogeneous NGS data is accounting for signal:noise ratio. Here, signal validation across studies was shown by intersecting sets between top MRMR genes and DEGs from RNASeq analysis. Non-intersecting sets introduce opportunity to explore spaceflight relevant genes and implementing ML methods across existing NGS datasets may overcome sample size limitations. ML coupled with existing analytical methods enhances understanding of disease by revealing common underlying pathways across datasets.

Machine Learning↗

Achievable noise performance of spectroscopic prototype DEPFET detectors

A new generation of spectroscopic X-ray DEPFET detectors has been produced here in the course of the detector development for the Wide Field Imager (WFI) of Athena. These devices served to perform a detailed analysis of the noise composition, which was enabled by the development of appropriate test algorithms. A result of the analysis is the distinction of different components, which sum up to the total noise. In particular the contribution of shot noise, white noise and 1/f noise to the readout noise is determined as well as the signal noise caused by the generation of charge carriers. The resulting parametrization enables the adaptation and optimization of operation modes to given purposes. The studied prototype detectors included 64×64 pixels with a linear gate design and provided an excellent noise, below 1.6 e - ENC at a readout time faster than 10 μs/pixel and a temperature of -80 °C in rolling-shutter operation. This performance is enabled by an extended signal integration time. A further noise reduction is prevented by the signal noise, caused by charge carrier generation. In order to demonstrate the low noise properties of the DEPFET transistor, the measurement conditions were adapted and a noise of 0.95 e - ENC was measured at the expense of the sensor size—by operating only parts of the sensor in window mode—and dynamic range—by using the Al Kα line at about 1.49 keV for calibration.

47 OTHER INSTRUMENTATION↗