Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SENSORS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) Sensor Suite

The Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite seeks to address the aerodynamic, aerothermodynamic, and thermal protection system (TPS) performance issues during atmospheric entry, descent, and landing of the Mars 2020 mission. Based on the highly successful instrumentation suite that flew on Mars Science Laboratory (MEDLI), the new sensor suite expands on the types of measurements and also seeks to answer questions not fully addressed by the previous mission. Sensor Package: MEDLI2 consists of 7 pressure transducers, 17 thermal plugs, 2 heat flux sensors, and one radiometer. The sensors are distributed across both the heatshield and backshell, unlike MEDLI (the first sensor suite), which was located solely on the heat-shield. The sensors will measure supersonic pressure on the forebody, a pressure measurement on the aftbody, near-surface and in-depth temperatures in the heatshield and backshell TPS materials, direct total heat flux on the aftbody, and direct radiative heating on the aftbody. Instrument Development: The supersonic pressure transducers, the direct heat flux sensors, and the radiometer all were tested during the development phase. The status of these sensors, including the piezo-resistive pressure sensors, will be presented. The current plans for qualification and calibration for all of the sensors will also be discussed. Post-Flight Data Analysis: Similar to MEDLI, the estimated flight trajectory will be reconstructed from the data. The aerodynamic parameters that will be reconstructed will be the axial force coefficient, freestream Mach number, base pressure, atmospheric density, and winds. The aerothermal quantities that will be determined are the heatshield and backshell aero-heating, turbulence transition across the heatshield, and TPS in-depth performance of PICA. By directly measuring the radiative and total heat fluxes on the back-shell, the convective portion of the heat flux will be estimated. The status of the current tools to perform the post-flight data analysis will be presented, along with plans for model improvements.

Hwang, Helen H.↗

Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) Sensor Suite

The Mars 2020 Entry, Descent, and Landing Instrumentation 2 (MEDLI2) sensor suite seeks to address the aerodynamic, aerothermodynamic, and thermal protection system (TPS) performance issues during atmospheric entry, descent, and landing of the Mars 2020 mission. Based on the highly successful instrumentation suite that flew on Mars Science Laboratory (MEDLI), the new sensor suite expands on the types of measurements and also seeks to answer questions not fully addressed by the previous mission. Sensor Package: MEDLI2 consists of 7 pressure transducers, 17 thermal plugs, 2 heat flux sensors, and one radiometer. The sensors are distributed across both the heatshield and backshell, unlike MEDLI (the first sensor suite), which was located solely on the heat-shield. The sensors will measure supersonic pressure on the forebody, a pressure measurement on the aftbody, near-surface and in-depth temperatures in the heatshield and backshell TPS materials, direct total heat flux on the aftbody, and direct radiative heating on the aftbody. Instrument Development: The supersonic pressure transducers, the direct heat flux sensors, and the radiometer all were tested during the development phase. The status of these sensors, including the piezo-resistive pressure sensors, will be presented. The current plans for qualification and calibration for all of the sensors will also be discussed. Post-Flight Data Analysis: Similar to MEDLI, the estimated flight trajectory will be reconstructed from the data. The aerodynamic parameters that will be reconstructed will be the axial force coefficient, freestream Mach number, base pressure, atmospheric density, and winds. The aerothermal quantities that will be determined are the heatshield and backshell aero-heating, turbulence transition across the heatshield, and TPS in-depth performance of PICA. By directly measuring the radiative and total heat fluxes on the back-shell, the convective portion of the heat flux will be estimated. The status of the current tools to perform the post-flight data analysis will be presented, along with plans for model improvements.

Hwang, Helen↗

Oxide Semiconductor Sensors for Monitoring Advanced Energy Conversion and Manufacturing Processes at High Temperature

To optimize the operation and functionality of high temperature systems such as slagging gasifiers, coal boilers and glass/steel smelters, it is important to monitor temperature, corrosion and erosion of the refractory used in such systems. Both thermocouple and failure sensors (and arrays of these) would be useful to monitor the health of any refractory or coatings in these systems. Many of such type of sensors are installed into the systems through open access ports within the refractory; however, there are some disadvantages of this approach where corrosive/erosive gas and molten materials can penetrate and compromise the system. The current work presents the development and performance of refractory with embedded high temperature sensors such as thermocouples, thermistors, and various spallation/crack monitoring sensors, which may be used within a variety of refractory brick in different high temperature processes and applications. The objective of our work is to develop high-temperature sensors composed of electroceramic materials that are chemically stable at high temperatures (750°-1500°C) and high pressures (up to 1000 psi) that can be used in monitoring temperature, corrosion and erosion process in refractory used in high energy systems. The high-temperature sensors investigated in this work were composed of various oxide composites directly embedded into the refractory oxides. The composites used for this work were synthesized by a mixed-oxide route. Metal oxides were inserted within a matrix material composed of refractory oxides (Al2O3, ZrO2, etc.). The physical and electrical properties were specifically manipulated by altering the level of percolation of the conductive species (metal oxides) within the refractory constituent (refractory oxide). An example of one of these embedded sensors consisted of an electroceramic-based thermocouple fabricated with two separate oxide composite compositions which were patterned to produce a couple within the interior of a refractory matrix. The thermocouple successfully displayed thermoelectric voltage trend (as a function of temperature), and the voltage was 220.0 mV near 1400 °C. In addition, corrosion tests on the refractory embedded sensors were performed. To evaluate corrosion in the refractory was exposed to high-temperature glass compositions over a 90 h period. The penetration of the glass through the refractory could be monitored by both an amperometric and voltametric based sensor. With this experiment, it was demonstrated that the embedded sensor could dynamically monitor the corrosion process, and thus, provide real-time feedback on both temperature and the refractory health.

20 FOSSIL-FUELED POWER PLANTS↗

Recent Advances in 3D Printed Sensors: Materials, Design, and Manufacturing

Sensors are of great importance in different aspects of research and industry. Future sensors will require high-efficient and low-cost manufacturing, as well as high-performance functionality in areas, such as mechanical sensing, biomedical, and optical applications. Recent advances in 3D printing open a new paradigm for sensors fabrication as a precision, customizable, and seamless process. Here, in this article, the state-of-the-art 3D printing methods in sensors manufacturing is reviewed and the performance of the 3D printed sensing materials and devices is summarized. Special attention is paid to emerging multimaterial printing and 4D printing technologies, which will benefit the fabrication of a new generation of structures with multifunctionalities. The content on 3D printed sensors covers piezoelectric sensors, medical, and optical sensing devices. The performance of 3D printed sensors in comparison with the sensors made by traditional manufacturing is also covered. Finally, section 4 provides the viewpoints on the future development of 3D printed sensors.

36 MATERIALS SCIENCE↗

Sensor cost-effectiveness analysis for data-driven fault detection and diagnostics in commercial buildings

Data-driven building fault detection and diagnostics (FDD) is heavily dependent on sensors. However, common sensors from Building Automation Systems are not optimized to maximize accuracy in FDD. Installing additional sensors that provide more detailed building system information is key to maximizing the performance of FDD solutions. Here in this paper, we present a sensor cost analysis workflow to quantify the economic implications of installing new sensors for FDD using the concept of sensor threshold marginal cost (STMC). STMC does not represent actual sensor cost. Rather, it represents a target cost based on the economic benefit that would be realized through improved FDD performance and one or more specified economic criteria. We calculate STMCs for multiple possible fault types and use fault prevalence information to aggregate STMCs into a single dollar value to determine the cost-effectiveness of a potential sensor investment. We conducted a case study using Oak Ridge National Laboratory's Flexible Research Platform (FRP) test facility as a reference. The case study demonstrates the feasibility of the analysis and highlights the key cost considerations in sensor selection for FDD. The results also indicate that identifying and installing the few key sensor(s) is critical to cost-effectively improve FDD performance.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ultra-fast and sensitive magneto-optical hydrogen sensors using a magnetic nano-cap array

Magnetism in curved nano-geometries has opened a new path to design novel characteristics and phenomena that could greatly impact the future fundamental and applied studies of materials. Here, in this report, a hexagonally-packed array of magnetic nano-caps (or nano-patches, NP) exhibiting unique magnetic anisotropy and optimal nanostructure for fast hydrogen kinetics is explored as a sensing element for the spark-free magnetic-circular-dichroism (MCD) H 2 sensor. The MCD H 2 sensor outperforms the state-of-the-art optical sensors reported to date and satisfies the most challenging performance targets imposed by US Department of Energy. In particular, a Pd 67 Co 33 NP sensor exhibits response time of t 90 < 0.9 s, recovery time of t 10 < 9.0 s over the 1-100 mbar H 2 partial pressure range, and limit of detection (LOD) of ~1 ppm. The LOD improves to <700 ppb, when the signal-to-noise ratio is enhanced by stacking three NP arrays. Using a 30-nm TAF (Teflon AF 2400) polymer coating, the sorption kinetics of the Pd 67 Co 33 /TAF sensor are significantly accelerated, with t 90 < 0.4 s and t 10 < 2.8 s over the same pressure range. When the Pd 67 Co 33 /TAF sensor is further coated with a 100-nm poly(methyl methacrylate) (PMMA) layer, a rapid sorption time of t 90 < 0.5 s, LOD < 1 ppm and excellent sensor accuracy (<2.5% full scale) are maintained, while the sensor obtains strong selectivity against interference gases and moisture and a negligible aging effect. The MCD nano-cap sensor platform may have a great impact on the future deployment of H 2 fuel, H 2 environmental monitoring sensors, and fast proton-based magneto-ionic devices.

Fast and sensitive hydrogen sensors↗

Humidity sensitivity of large area silicon sensors: Study and implications

The production of large area sensors is one of the main challenges that the ATLAS collaboration faces for the new Inner-Tracker full-silicon detector. During the prototype fabrication phase for the High Luminosity Large Hadron Collider upgrade, several ATLAS institutes observed indications of humidity sensitivity of large area sensors, even at relative humidities well below the dew point. Specifically, prototype Barrel and End-Cap silicon strip sensors fabricated in 6-inch wafers manifest a prompt decrease of the breakdown voltage when operating under high relative humidity, adversely affecting the performance of the sensors. In addition to the investigation of these prototype sensors, a specific fabrication batch with special passivation is also studied, allowing for a deeper understanding of the responsible mechanisms. Here we present an extensive study of this behaviour on large area sensors. The locations of the hotspots at the breakdown voltage at high humidity are revealed using different infrared thermography techniques. Several palliative treatments are attempted, proving the influence of sensor cleaning methods, as well as baking, on the device performance, but no improvement on the humidity sensitivity was achieved. Furthermore, a study of the incidence of the sensitivity in different batches is also presented, introducing a hypothesis of the origins of the humidity sensitivity associated to the sensor edge design, together with passivation thickness and conformity. Several actions to be taken during sensor production and assembly are extracted from this study, in order to minimize the impact of humidity sensitivity on the performance of large area silicon sensors for High Energy Physics experiments.

47 OTHER INSTRUMENTATION↗

Aerosol jet printed 3 omega sensors for thermal conductivity measurement

The 3 omega (3ω) method is a trusted technique for measuring thermal conductivity—a fundamental material property of critical importance in a broad range of applications. However, traditional 3ω sensor processing requires some form of physical vapor deposition, such as metal evaporation or sputtering. These 3ω sensor deposition techniques limit the materials and sample sizes applicable to the 3ω method. This work demonstrates an aerosol jet printing method to directly print silver 3ω sensors that yield accurate temperature-dependent measurement up to 300 °C on materials with thermal conductivity ranging from 1 to 150 W/m K. The interrelationship between printed sensor geometry, sensor thermal stability, and applicability to the 3ω method is examined. Thermal conductivity measurement with 3ω sensors conventionally sintered at 300 °C agrees to independent laser flash measurement within 4% from room temperature to 150 °C. An unconventional rapid high-temperature sintering method is shown to produce sensors that agree within 3% of the laser flash measurements from room temperature to 300 °C. The rapid sintering profiles also reduced the sensor–substrate thermal boundary resistance of the printed sensors by as much as 88%. The direct printing of 3ω sensors creates opportunities for measurement of thermal transport properties in applications previously inapplicable to the 3ω method.

47 OTHER INSTRUMENTATION↗

Microbial sensor variation across biogeochemical conditions in the terrestrial deep subsurface

ABSTRACT Microbes can be found in abundance many kilometers underground. While microbial metabolic capabilities have been examined across different geochemical settings, it remains unclear how changes in subsurface niches affect microbial needs to sense and respond to their environment. To address this question, we examined how microbial extracellular sensor systems vary with environmental conditions across metagenomes at different Deep Mine Microbial Observatory (DeMMO) subsurface sites. Because two-component systems (TCSs) directly sense extracellular conditions and convert this information into intracellular biochemical responses, we expected that this sensor family would vary across isolated oligotrophic subterranean environments that differ in abiotic and biotic conditions. TCSs were found at all six subsurface sites, the service water control, and the surface site, with an average of 0.88 sensor histidine kinases (HKs) per 100 genes across all sites. Abundance was greater in subsurface fracture fluids compared with surface-derived fluids, and candidate phyla radiation (CPR) bacteria presented the lowest HK frequencies. Measures of microbial diversity, such as the Shannon diversity index, revealed that HK abundance is inversely correlated with microbial diversity ( r 2 = 0.81). Among the geochemical parameters measured, HK frequency correlated most strongly with variance in dissolved organic carbon ( r 2 = 0.82). Taken together, these results implicate the abiotic and biotic properties of an ecological niche as drivers of sensor needs, and they suggest that microbes in environments with large fluctuations in organic nutrients (e.g., lacustrine, terrestrial, and coastal ecosystems) may require greater TCS diversity than ecosystems with low nutrients (e.g., open ocean). IMPORTANCE The ability to detect extracellular environmental conditions is a fundamental property of all life forms. Because microbial two-component sensor systems convert information about extracellular conditions into biochemical information that controls their behaviors, we evaluated how two-component sensor systems evolved within the deep Earth across multiple sites where abiotic and biotic properties vary. We show that these sensor systems remain abundant in microbial consortia at all subterranean sampling sites and observe correlations between sensor system abundances and abiotic (dissolved organic carbon variation) and biotic (consortia diversity) properties. These results suggest that multiple environmental properties may drive sensor protein evolution and highlight the need for further studies of metagenomic and geochemical data in parallel to understand the drivers of microbial sensor evolution.

response regulator↗

AOI [1]: Passive Wireless Sensor Systems Fabricated by Direct-Writing for Temperature and Health Monitoring of Energy Systems in Harsh-Environments (Final Report)

Researchers at West Virginia University (WVU) propose to demonstrate a wireless, high-temperature sensor system for monitoring the temperature and health of energy-system components. The active sensor and electronics for wireless communication will be composed entirely of an electroceramic materials (conductive ceramics) which are capable of withstanding the harsh-environments required for fossil energy-based technologies. This work will focus primarily on the fabrication and testing of temperature (thermocouples and thermistors) and health (strain/stress and crack propagation sensors) that function at extreme temperatures (up to 700-1700ºC). The electronics will accompany the high-temperature sensor, which will include a passive wireless communication circuit that allows the transmission of the data based on the LCR resonance principle to a near-by reader antenna. This passive transmission of data will reduce the need for interconnect wires near the active, and possibly rotating, energy-system component. The research will include process development to permit the 2D/3D direct-writing of the entire sensor and communication circuit onto the energy-system component. The direct-writing will be facilitated by using silicon-based polymer-derived precursors to form the high-temperature, stable electroceramic compositions. In addition, methods for direct-writing the circuit onto a fugitive carrier substrate will be completed, which will permit a “peel-and-stick”-like transfer of the sensor circuit to the energy-system component. This feature will allow the economical and precise placement of the sensor circuit onto components of various shapes and locations, without altering the geometry and active features of the manufactured component, or the removal (or decommissioning) of the component for installation. The proposed work will be directed at the following areas: 1) Investigation of phase formation, sintering/grain growth, and electrical properties of polymer-derived electroceramic composites; 2) Definition of processes to direct-write through ink-jet and robo-casting the polymer-derived electroceramic composites onto oxide and polymer surfaces; 3) Development of methods to form monolithic "peel-and-stick" preforms that will efficiently transfer the sensor circuit to ceramic surfaces after thermal treatment; 4) Design of passive wireless LCR circuits and receiver (reader) antennas for communication and testing at high temperatures; 5) Investigation of the passive wireless sensor system developed (and method of transferring sensor system) for temperature and stress/strain measurements on a SOFC repeat unit and a singular gas turbine blade prototype as example applications.

01 COAL, LIGNITE, AND PEAT↗

Development of a Portable In Situ Phosphorous Sensor

While phosphorus is a critical nutrient for all forms of life, runoff leads to phosphorus accumulation in surface water where it can cause a variety of health, environmental, and economic problems. The Department of Energy is interested in conducting long-term field experiments to monitor the impact of phosphorus in terrestrial and aquatic environments, and to better understand a cost vs. benefit analysis of reducing phosphorus pollution. Performing such long-term experiments requires affordable sensors capable of monitoring low-level phosphorus concentrations under challenging environmental conditions. However, such sensors are currently not available. The goal of this proposed project is to develop and demonstrate a low-cost portable phosphorus sensor suitable for in situ measurements. We will determine the technical requirements for a Raman-based sensor system, design and build a signal amplifier, integrate it with a Raman-based sensor, and demonstrate a proof-of-concept level sensor system. The expected accomplishments for Phase I include the identification of the technical requirements of a combined Raman laser/spectrometer and cavity enhancement system, building a proof-of-concept level sensor system capable of detecting orthophosphate compounds at the desired level of 0.25 mg P/L and organic P compounds, and verification of the sensor performance under laboratory and field conditions. In addition, we will identify initial hardening requirements that will need to be implemented during Phase II. While we plan to develop an integrated sensor system for monitoring phosphorus, the cavity-based enhancement system can also be used in combination with other (non-phosphorus) Raman sensors that we plan to develop or that are already commercially available. A recent market report highlights the increasing demand for such environmental monitoring applications, with the market for chemical detection anticipated to grow at a compound annual growth rate of 6.5% (2020-2025). Wide-spread monitoring of phosphorus could reduce the damage from eutrophication in freshwater, which is estimated to be $2.2 billion annually, thereby increasing biodiversity, reducing costs required for drinking water treatment, and decreasing economic losses related to recreation and angling and lake property values.

54 ENVIRONMENTAL SCIENCES↗

Biomimetic Fly Eye Sensor for Real-Time Target Tracking

The project objective is to design, build, and demonstrate a biomimetic (inspired by biology) smart sensor based on the common house fly eye for real-time target tracking in three dimensions (3-D). The sensor makes use of revolutionary optical sensor design resulting in significantly improved motion detection capabilities when compared with conventional optical sensors. The design is motivated by the parallel nature of the flys vision system and its demonstrated hyperacuity or precision of visual localization beyond the conventional resolution limit. This means that the sensor is able to accurately detect very fast motion and small changes in motion. The analog architecture of the sensor allows for real-time solution at adjustable bandwidths depending on the application. The low cost, exceptionally lightweight, small form factor, low power requirements, and low computation requirements of the sensor make it ideally suited to many aeronautics applications that have limitations on weight, power, and processing time. The sensor is modular and can be easily adapted in scale and manufactured for a wide variety of sensing applications. Advanced target tracking algorithms will be developed to allow the sensor to track a target in 3-D. These algorithms will be implemented in the smart sensors hardware to enable real-time target tracking.

wing position measurement system↗

The NREL Sensor Laboratory: Status and Future Directions for Hydrogen Detection

The NREL Hydrogen Sensor Laboratory was commissioned in 2010 as a resource for the national and international hydrogen community to ensure the availability and proper use of hydrogen sensors. Since then, the Sensor Laboratory has provided unbiased verification of hydrogen sensor performance for sensor developers, end-users, and regulatory agencies and has also provided active support for numerous code and standards development organizations. Although sensor performance assessment remains a core capability, the mission of the NREL Sensor Laboratory has expanded toward a more holistic approach regarding the role of hydrogen detection and its implementation strategy for both assurance of facility safety as well as for process control applications. Active monitoring for detection of unintended releases has been identified by the NFPA 2 Storage Task Group as a viable approach for improving facility safety and lowering setbacks. The current research program for the Sensor Laboratory addresses both conventional and advanced developing detection strategies in response to the emerging large-scale markets, such as those envisioned by H2@Scale. These emerging hydrogen applications may require alternative detection strategies that supplement and may ultimately supplant the use of traditional sensors for monitoring hydrogen releases. Research focus areas for the NREL Sensor Laboratory now encompasses the characterization of released hydrogen behavior to optimize detection strategies for both indoor and outdoor applications, advanced methods of hydrogen leak detection such as hydrogen wide area monitoring approaches for large scale and distributed applications, the incorporation of active monitoring as a risk reduction strategy to improve safety at hydrogen facilities, and continuing support of hydrogen safety codes and standards. In addition to assurance of safety, detection will be critical for process control applications, such as hydrogen fuel quality verification for fuel cell vehicle applications and for monitoring and controlling of hydrogen-natural gas blend composition.

codes and standards↗

Metal-embedded fiber optic sensor packaging and signal demodulation scheme towards high-frequency dynamic measurements in harsh environments

Optical fiber-based sensors are commonly used for industrial monitoring and control processes due to their small size, resistance to electromagnetic interference, and ability to perform a wide variety of high-precision measurements. However, implementing optical fiber sensors in harsh environments is challenging because they are small and fragile. Proper packaging of fiber-optic sensors could extend their use to harsh environments, including at high temperature and under high radiation. Furthermore, conventional fiber optic-based measurement systems often use computationally expensive signal processing algorithms which hinder their use in high-frequency dynamic applications. This work reports on the design of an optical fiber-pressure sensor system based on low-coherence interferometry that uses a metal-embedded optical fiber to provide a robust sensor package. Additionally, a novel phase demodulation scheme is proposed to extract length changes from the deformation of a thin diaphragm within a Fabry–Pérot cavity to measure pressure. The sensor has been tested to ±100 kPa, has a theoretical linear response over a 270 kPa dynamic range (24 dB maximum signal-to-noise ratio), and can resolve pressure transients up to 3910 kPa/s. Sampling at 100 kHz, the present sensor can resolve 2 kPa dynamic pressures at frequencies up to 2 kHz. Faster transients on the order of tens to hundreds of kHz can theoretically be resolved at the expense of decreasing the maximum resolvable amplitude. A methodology for designing a LCI pressure sensor for a given application is outlined based on the limitations imposed by the Nyquist criterion, the diaphragm's resonant frequency, the LCI optoelectronics, and the phase demodulation scheme. The sensor is the first to implement a low-coherence light source and a Fabry–Pérot interferometer designed to provide real-time high-fidelity pressure measurements using a metal-embedded optical fiber. The demonstrated sensor provides a platform for sensing in harsh conditions such as in nuclear and energy applications.

47 OTHER INSTRUMENTATION↗

Exceptional Electrical Detection of Trace NO 2 via Mixed Metal MOF-on-MOF Film-Based Sensors

The tunability of metal–organic frameworks (MOFs) makes them exceptional materials for the development of highly selective, low-power sensors for toxic gas detection. Herein, we demonstrate enhanced detection of NO 2 gas by a MOF-based electrical impedance sensor made using a unique mixed metal MOF-on-MOF synthesis. For this work, a combined experimental and computational study was performed using the exemplar Ni x Mg 1–x -MOF-74 to understand the fundamental structure–property relationships behind metal mixing and MOF film synthesis methods on sensor performance. Density functional theory results indicated that the presence of Ni in Mg-MOF-74 increased framework stability and increased the electron density of states at lower energies near the HOMO, as well as enhanced the NO 2 –Mg adsorption interaction. Impedance data of the Ni x Mg 1–x -MOF-74 films with larger Ni contents showed greater impedance change after exposure to 1 ppm of NO 2 gas. Furthermore, when synthesized through either a drop-cast or direct solvothermal film growth approach, the monometallic Ni-based sensors had the best performance. However, the mixed metal Ni x Mg 1–x -MOF-74 sensors synthesized through a MOF-on-MOF approach resulted in the highest impedance change, outperforming all monometallic Ni-based sensors. In particular, the mixed metal Ni-on-Mg-MOF-74 film was the best-performing sensor with an impedance change of 309 upon trace NO 2 exposure. Change in impedance response after NO 2 exposure was improved by 52% compared to the best monometallic Ni-on-Ni-MOF-74 sensor. Structural analysis of the Ni-on-Mg film showed that the first Mg-MOF-74 layer acts as a structural template controlling the structural features of the final film after metal exchange with Ni. This led to improved film quality, evidenced by the greater crystallinity and larger MOF grain sizes, and resulted in enhanced sensor performance which was not achievable through other metal mixing methods. Altogether, this study identifies structure–property relationships and synthetic templating methods that inform MOF-based sensor design, allowing for improved detection of toxic compounds.

36 MATERIALS SCIENCE↗

Sensor Placement Optimization Software Applied to Site-Scale Methane-Emissions Monitoring

Advances in sensor technology have increased our ability to monitor a wide range of environments. However, even as the cost of sensors decline, only a limited number of sensors can be installed at any given site. The physical placement of sensors, along with the sensor technology and operating conditions, can have a large impact on our ability to adequately monitor environmental change. This paper introduces a new open-source Python package, called Chama, that determines optimal sensor placement and technology to improve a sensor network’s detection capabilities. Additionally, the methods are demonstrated using site-specific methane emission scenarios that capture uncertainty in wind conditions and emission characteristics. Mixed-integer linear programming formulations are used to determine sensor locations and detection thresholds that maximize detection of the emission scenarios. The optimized sensor networks consistently increase the ability to detect leaks, as compared to sensors placed near each potential emission source or along the perimeter of the site.

47 OTHER INSTRUMENTATION↗

Performance of Embedded Sensors in 3D Printed SiC

This report summarizes recent advances in embedding sensors in 3D printed silicon carbide (SiC) ceramic components under the Transformational Challenge Reactor (TCR) program. The additive manufacturing technologies developed under this program will enable fabrication of complex structures with embedded fuels and sensors. The sensors will be capable of characterizing fuel performance using spatially distributed measurements at the most strategic locations that would be otherwise inaccessible using conventional manufacturing techniques. While previous programmatic updates describe initial concepts for embedding sensors, materials selection, and initial characterization of the embedded sensors, the technology requires further demonstration, and quality-significant procedures must be established before the embedding technology is ready for adoption by industry. To this end, this report describes the most effective techniques that have been used to embed functional sensors in 3D printed components using a combination of binder-jet additive manufacturing and chemical vapor infiltration (CVI). A detailed procedure describes each step in the process and is available upon request. Molybdenum (Mo)-sheathed thermocouples have been successfully embedded in complex SiC components, and temperatures were monitored in situ during the embedding process. Post-embedding measurements showed no significant hysteresis, and characterization of the interface revealed qualitatively strong bonding around the entire perimeter of the sensor sheath. Distributed fiber-optic temperature sensors were able to briefly measure temperature profiles during CVI, but they ultimately failed prior to completion of the CVI run. The failure appears to be related to the fiber coating at temperatures close to 1,000°C. Future work will focus on irradiation testing of embedded thermocouples and other sheathed electrical sensors, as well as the identification of fiber-optic sensor coatings that can survive CVI.

42 ENGINEERING↗

Preliminary Sensitivity Analysis for Sensors Impacts on Building Control Performance

This report describes the preliminary sensitivity analysis for sensor impacts on building control performance through the US Department of Energy’s Oak Ridge National Laboratory’s Flexible Research Platform (FRP-2) building. The rooftop unit system provides cooling and heating to the building. The main heating coil is a gas heating coil. Each zone is served by a variable air volume box with an electricity reheat coil. The rooftop unit and variable air volume box controls adopted the practical control sequences from ASHRAE Guideline 36-2018: High-Performance Sequences of Operation. For sensors, the incipient (time-changing) sensor errors, including bias sensor error and precision sensor error, are the inputs of interest. The outputs are energy consumption and thermal comfort (e.g., the predicted percentage of dissatisfied occupants). The large-scale simulation (3,600 cases) was conducted on a cloud platform by integrating sensor errors and ASHRAE Guideline 36 control sequences into an emulator based on the EnergyPlus simulation program with Python energy management system feature. The surrogate models were developed based on cloud simulation results. The uncertainty analysis showed that the sensor errors substantially affect building energy consumption and thermal comfort. The sensitivity analysis shows a ranking of sensor error impacts for each interested output item (e.g., cooling energy, reheat coil heating energy, predicted percentage of dissatisfied occupants). In FY 2022, sensor locations, types, and costs will be evaluated. The field test in Oak Ridge National Laboratory’s Flexible Research Platform building regarding sensor impacts will also be performed. Finally, a comparative analysis will be conducted based on the field test results and emulator results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗