Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCANNING DEVICE”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Photo-Crosslinkable Naphthalene Diimide Polymer for Solution-Processed n – i – p Perovskite Solar Cells

We copolymerize a norbornene monomer bearing a pendant naphthalene diimide with a norbornene bearing a cinnamate pendant moiety to synthesize a crosslinkable electron-transporting polymer and study its use in solution-processed n–i–p perovskite solar cells. The crosslinked material exhibits over 90% transparency in the visible region and higher thermal stability (>300 °C) and lower surface energy than the corresponding homopolymer of the naphthalene diimide functionalized norbornene. Coating an ITO surface with the photo-crosslinked copolymer yields a slightly lower work function than homopolymer-coated ITO. We show that the morphologies of the perovskite films deposited on both polymers are similar (~300 nm features) based upon scanning electron microscopy. Our solar-cell device results show that the crosslinked naphthalene diimide polymer gives a higher open-circuit voltage (1.08 vs 1.05 V), fill factor (average 64.43 vs 58.77%), and stabilized power conversion efficiency (12.28 vs 10.33%) compared to its non-crosslinked homopolymer counterpart, as well as reduced hysteresis. As a result, we attribute the improved performance to decreased work function, reduced nonradiative recombination, and higher shunt resistance.

14 SOLAR ENERGY↗

Vacancy structures and melting behavior in rock-salt GeSbTe

Ge-Sb-Te alloys have been widely used in optical/electrical memory storage. Because of the extremely fast crystalline-amorphous transition, they are also expected to play a vital role in next generation nonvolatile microelectronic memory devices. However, the distribution and structural properties of vacancies have been one of the key issues in determining the speed of melting (or amorphization), phase-stability, and heat-dissipation of rock-salt GeSbTe, which is crucial for its technological breakthrough in memory devices. Using spherical aberration-aberration corrected scanning transmission electron microscopy and atomic scale energy-dispersive X-ray mapping, we observe a new rock-salt structure with high-degree vacancy ordering (or layered-like ordering) at an elevated temperature, which is a result of phase transition from the rock-salt phase with randomly distributed vacancies. First-principles calculations reveal that the phase transition is an energetically favored process. Furthermore, molecular dynamics studies suggest that the melting of the cubic rock-salt phases is initiated at the vacancies, which propagate to nearby regions. The observation of multi-rock-salt phases suggests another route for multi-level data storage using GeSbTe.

36 MATERIALS SCIENCE↗

Observation of rebirth of metallic paths during resistance switching of metal nanowire

To clarify the mechanism of resistance-switching phenomena, we have investigated the change in the electronic structure of a Ni nanowire device during resistance-switching operations using scanning photoelectron microscopy techniques. We directly observed the disappearance of density of state (DOS) at the Fermi level (E{sub F}) in a high-resistance state and recovery of a finite DOS at E{sub F} in a low-resistance state. These results are direct evidence that the Ni nanowire is fully oxidized after switching to the high-resistance state and that Ni-metal conductive paths in the oxidized nanowire are recovered in the low-resistance state.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

2024 roadmap on magnetic microscopy techniques and their applications in materials science

Considering the growing interest in magnetic materials for unconventional computing, data storage, and sensor applications, there is active research not only on material synthesis but also characterisation of their properties. In addition to structural and integral magnetic characterisations, imaging of magnetisation patterns, current distributions and magnetic fields at nano- and microscale is of major importance to understand the material responses and qualify them for specific applications. In this roadmap, we aim to cover a broad portfolio of techniques to perform nano- and microscale magnetic imaging using superconducting quantum interference devices, spin centre and Hall effect magnetometries, scanning probe microscopies, x-ray- and electron-based methods as well as magnetooptics and nanoscale magnetic resonance imaging. The roadmap is aimed as a single access point of information for experts in the field as well as the young generation of students outlining prospects of the development of magnetic imaging technologies for the upcoming decade with a focus on physics, materials science, and chemistry of planar, three-dimensional and geometrically curved objects of different material classes including two-dimensional materials, complex oxides, semi-metals, multiferroics, skyrmions, antiferromagnets, frustrated magnets, magnetic molecules/nanoparticles, ionic conductors, superconductors, spintronic and spinorbitronic materials.

2D materials↗

An atomic force microscopy-based method for line edge roughness measurement

With the constant decrease of semiconductor device dimensions, line edge roughness (LER) becomes one of the most important sources of device variability and needs to be controlled below 2 nm for the future technological nodes of the semiconductor roadmap. LER control at the nanometer scale requires accurate measurements. We introduce a technique for LER measurement based upon the atomic force microscope (AFM). In this technique, the sample is tilted at about 45 Degree-Sign and feature sidewalls are scanned along their length with the AFM tip to obtain three-dimensional images. The small radius of curvature of the tip together with the low noise level of a laboratory AFM result in high resolution images. Half profiles and LER values on all the height of the sidewalls are extracted from the 3D images using a procedure that we developed. The influence of sample angle variations on the measurements is shown to be small. The technique is applied to the study of a full pattern transfer into a simplified gate stack. The images obtained are qualitatively consistent with cross-section scanning electron microscopy images and the average LER values agree with that obtained by critical dimension scanning electron microscopy. In addition to its high resolution, this technique presents several advantages such as the ability to image the foot of photoresist lines, complex multi-layer stacks regardless of the materials, and deep re-entrant profiles.

36 MATERIALS SCIENCE↗

Resolution in Carrier Profiling Semiconductors by Scanning Spreading Resistance Microscopy and Scanning Frequency Comb Microscopy

High resolution measurements of the carrier profile in semiconductor devices is required as the semiconductor industry progresses from the 10-nm lithography node to 7-nm and beyond. We examine the factors which determine the resolution of the present method of scanning spreading resistance microscopy as well as such factors for the newer method of scanning frequency comb microscopy that is now under development. Also, for the first time, we consider the sensitivity of both methods to the location of heterogeneities in the semiconductor. In addition, mesoscopic effects on these measurements are considered for the first time. Two simple analytical models are extended to study the sensitivity to heterogeneities as well as mesoscopic effects.

36 MATERIALS SCIENCE↗

Shear-free mixing to achieve accurate temporospatial nanoscale kinetics through scanning-SAXS: ion-induced phase transition of dispersed cellulose nanocrystals

Time-resolved in situ characterization of well-defined mixing processes using small-angle X-ray scattering (SAXS) is usually challenging, especially if the process involves changes of material viscoelasticity. In specific, it can be difficult to create a continuous mixing experiment without shearing the material of interest; a desirable situation since shear flow both affects nanoscale structures and flow stability as well as resulting in unreliable time-resolved data. Here, we demonstrate a flow-focusing mixing device for in situ nanostructural characterization using scanning-SAXS. Given the interfacial tension and viscosity ratio between core and sheath fluids, the core material confined by sheath flows is completely detached from the walls and forms a zero-shear plug flow at the channel center, allowing for a trivial conversion of spatial coordinates to mixing times. With this technique, the time-resolved gel formation of dispersed cellulose nanocrystals (CNCs) was studied by mixing with a sodium chloride solution. It is observed how locally ordered regions, so called tactoids, are disrupted when the added monovalent ions affect the electrostatic interactions, which in turn leads to a loss of CNC alignment through enhanced rotary diffusion. The demonstrated flow-focusing scanning-SAXS technique can be used to unveil important kinetics during structural formation of nanocellulosic materials. However, the same technique is also applicable in many soft matter systems to provide new insights into the nanoscale dynamics during mixing.

36 MATERIALS SCIENCE↗

Factors affecting eluation characteristics of sorption generators of technetium-99m

The influence of the adsorbed mass of molybdenum on the width of eluation profiles of generators and the patterns of molybdenum distribution in the amount of chromatographic columns by scanning them on the germanium-gallium detector using collimating device are studied. The boundary conditions under which the maximum value of {sup 99m}Tc yield from generators Y{sub e} = 1 are defined. After scanning the columns, it was found out that the degree of filling the columns with molybdenum Q and the value of its maximum adsorption depend naturally on the total weight of the adsorbed mass. In order to achieve the condition Y{sub e} = 1 the value of Q should be at least 85%.

07 ISOTOPE AND RADIATION SOURCES↗

Abstract for CRADA between NETL and the University of Massachusetts Lowell (AGMT-1275)

The demand for printed electronics over conventional electronics is growing each year due to their low costs, low material waste during manufacturing, and compatibility with flexible substrates. The development of inks for printed electronics is a challenge because each printing technology requires different viscosities and curing behaviors to create devices with controlled structures at the micron scale, or smaller. Carbon is a great candidate for fabricating printed electronics devices because it is inexpensive and earth abundant, easily functionalized to impart miscibility with solvent systems, and has electrical properties that can be tuned from insulating to conducting. Despite these advantages, carbons are rarely used for printed electronics because there is a scarcity of inks available for non-contact printing technologies. To address these challenges, the National Energy Technology Laboratory (NETL) will collaborate with the University of Massachusetts Lowell (Participant) through its Printed Electronics Research Collaborative (PERC) to develop engineered carbons and ink formulations optimized specifically for printing radio- and microwave-frequency electronic devices using ink jet, aerosol jet, syringe dispensing, and other additive manufacturing techniques. NETL will process coal, petroleum, and other carbon feedstocks to make engineered carbons with the appropriate composition, microstructure, surface functionalization, and particle morphologies needed to stabilize ink suspensions and impart useful electronic properties to printed devices. The University of Massachusetts Lowell will utilize these engineered carbons to determine which solvent systems and ink additives are needed to achieve the appropriate viscosity, stability, and printability to make useful ink formulations. The University of Massachusetts Lowell will then utilize these inks to manufacture printed resistors and conductors using inkjet, aerosol jet, and syringe dispensing printing methods and will characterize device performance using four-point probe resistivity measurements, contact angle measurements to assess wettability, adhesion evaluation to various substrates, and focused ion beam and scanning electron microscopy for surface and density investigations of printed devices.

36 MATERIALS SCIENCE↗

In Situ Study of the Impact of Aberration-Corrected Electron-Beam Lithography on the Electronic Transport of Suspended Graphene Devices

The implementation of aberration-corrected electron beam lithography (AC-EBL) in a 200 keV scanning transmission electron microscope (STEM) is a novel technique that could be used for the fabrication of quantum devices based on 2D atomic crystals with single nanometer critical dimensions, allowing to observe more robust quantum effects. In this work we study electron beam sculpturing of nanostructures on suspended graphene field effect transistors using AC-EBL, focusing on the in situ characterization of the impact of electron beam exposure on device electronic transport quality. When AC-EBL is performed on a graphene channel (local exposure) or on the outside vicinity of a graphene channel (non-local exposure), the charge transport characteristics of graphene can be significantly affected due to charge doping and scattering. While the detrimental effect of non-local exposure can be largely removed by vigorous annealing, local-exposure induced damage is irreversible and cannot be fixed by annealing. We discuss the possible causes of the observed exposure effects. Our results provide guidance to the future development of high-energy electron beam lithography for nanomaterial device fabrication.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Gas cluster ion beam assisted NiPt germano-silicide formation on SiGe

We report the formation of very uniform and smooth Ni(Pt)Si on epitaxially grown SiGe using Si gas cluster ion beam treatment after metal-rich silicide formation. The gas cluster ion implantation process was optimized to infuse Si into the metal-rich silicide layer and lowered the NiSi nucleation temperature significantly according to in situ X-ray diffraction measurements. This novel method which leads to more uniform films can also be used to control silicide depth in ultra-shallow junctions, especially for high Ge containing devices, where silicidation is problematic as it leads to much rougher interfaces.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Theory of Electron Imaging in Small Devices

The research in this program involved theoretical investigations of the transport of charge in graphene and small heterostructure devices. There is an important trend toward imaging electronic systems in real space, with the goal of understanding the specifics of individual samples rather than settling for ensemble and statistical descriptions. For example one of our goals has been the understanding of scanning probe microscopy (SPM) imaging of systems in which the motion of the carriers is restricted to two degrees of freedom, such as in grapheme and the two dimensional electron (and hole) gas (2DEGs and 2DHGs) in GaAs/AlGaAs heterostructures, or when the motion is restricted to one degree of freedom as in nanowires. SPM imaging uses the tip of a movable charged probe to alter the electrons locally, depleting or alternatively increasing the amount of charges in the electron gas just below the tip results in a change to the flow pattern of the charge. The focus of this research was on understanding how the tunable tip affects functional aspects of the device that can be used to understand electronic and transport properties. For instance, scanning over the device while measuring the conductance results in conductance maps, an imaging of the charge transport. This imaging is often semi-direct and requires theory and interpretation to extract all that can be deduced about the underlying physical quantities.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Reliable strain measurement in transistor arrays by robust scanning transmission electron microscopy

Accurate measurement of the strain field in the channels of transistor arrays is critical for strain engineering in modern electronic devices. We applied atomic-resolution high-angle annular dark-field scanning transmission electron microscopy to quantitative measurement of the strain field in transistor arrays. The quantitative strain profile over 20 transistors was obtained with high reliability and a precision of 0.1%. The strain field was found to form homogeneously in the channels of the transistor arrays. Furthermore, strain relaxation due to the thin foil effect was quantitatively investigated for thicknesses of 35 to 275 nm.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Effects of rapid thermal annealing on the structural and local atomic properties of ZnO: Ge nanocomposite thin films

We have investigated the structural and local atomic properties of Ge nanocrystals (Ge-ncs) embedded ZnO (ZnO: Ge) thin films. The films were deposited by sequential sputtering of ZnO and Ge thin film layers on z-cut quartz substrates followed by an ex-situ rapid thermal annealing (RTA) at 600 °C for 30, 60, and 90 s under forming gas atmosphere. Effects of RTA time on the evolution of Ge-ncs were investigated by x-ray diffraction (XRD), scanning electron microscopy (SEM), hard x-ray photoelectron spectroscopy (HAXPES), and extended x-ray absorption fine structure (EXAFS). XRD patterns have clearly shown that fcc diamond phase Ge-ncs of sizes ranging between 18 and 27 nm are formed upon RTA and no Ge-oxide peak has been detected. However, cross-section SEM images have clearly revealed that after RTA process, Ge layers form varying size nanoclusters composed of Ge-ncs regions. EXAFS performed at the Ge K-edge to probe the local atomic structure of the Ge-ncs has revealed that as prepared ZnO:Ge possesses Ge-oxide but subsequent RTA leads to crystalline Ge structure without the oxide layer. In order to study the occupied electronic structure, HAXPES has been utilized. The peak separation between the Zn 2p and Ge 3d shows no significant change due to RTA. This implies little change in the valence band offset due to RTA.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Actively triggered 4d cone-beam CT acquisition

Purpose: 4d cone-beam computed tomography (CBCT) scans are usually reconstructed by extracting the motion information from the 2d projections or an external surrogate signal, and binning the individual projections into multiple respiratory phases. In this “after-the-fact” binning approach, however, projections are unevenly distributed over respiratory phases resulting in inefficient utilization of imaging dose. To avoid excess dose in certain respiratory phases, and poor image quality due to a lack of projections in others, the authors have developed a novel 4d CBCT acquisition framework which actively triggers 2d projections based on the forward-predicted position of the tumor.Methods: The forward-prediction of the tumor position was independently established using either (i) an electromagnetic (EM) tracking system based on implanted EM-transponders which act as a surrogate for the tumor position, or (ii) an external motion sensor measuring the chest-wall displacement and correlating this external motion to the phase-shifted diaphragm motion derived from the acquired images. In order to avoid EM-induced artifacts in the imaging detector, the authors devised a simple but effective “Faraday” shielding cage. The authors demonstrated the feasibility of their acquisition strategy by scanning an anthropomorphic lung phantom moving on 1d or 2d sinusoidal trajectories.Results: With both tumor position devices, the authors were able to acquire 4d CBCTs free of motion blurring. For scans based on the EM tracking system, reconstruction artifacts stemming from the presence of the EM-array and the EM-transponders were greatly reduced using newly developed correction algorithms. By tuning the imaging frequency independently for each respiratory phase prior to acquisition, it was possible to harmonize the number of projections over respiratory phases. Depending on the breathing period (3.5 or 5 s) and the gantry rotation time (4 or 5 min), between ∼90 and 145 projections were acquired per respiratory phase resulting in a dose of ∼1.7–2.6 mGy per respiratory phase. Further dose savings and decreases in the scanning time are possible by acquiring only a subset of all respiratory phases, for example, peak-exhale and peak-inhale only scans.Conclusions: This study is the first experimental demonstration of a new 4d CBCT acquisition paradigm in which imaging dose is efficiently utilized by actively triggering only those projections that are desired for the reconstruction process.

61 RADIATION PROTECTION AND DOSIMETRY↗

Structure and photoluminescence properties of carbon nanotip-vertical graphene nanohybrids

We report on the effective enhancement and tuning of photoluminescence (PL) by combining vertical graphene nanoflakes (VGs) and carbon nanotips (CNTPs). The VGs are grown on the vertical CNTPs by hot filament chemical vapor deposition in the methane environment, where the CNTPs are synthesized on silicon substrates by CH{sub 4}-H{sub 2}-N{sub 2} plasma-enhanced hot filament chemical vapor deposition. The results of field emission scanning electron microscopy, transmission electron microscopy, micro-Raman spectroscopy, and X-ray photoelectron spectroscopy indicate that the VGs can be grown on the CNTP and silicon substrate surfaces with the orientation perpendicular to the surfaces of CNTPs and silicon substrates. The PL properties of VG, CNTP, and CNTP-VG structures are studied using a 325 nm line of He-Cd laser as the excitation source. The PL results indicate that the PL of VGs is enhanced by the CNTPs due to the increasing density of PL emitters, while the PL properties of the nanohybrid system can be tuned. Furthermore, the potential applications of CNTP-VG structures in optoelectronic devices are analyzed. These results contribute to the design of functional graphene-based materials and the development of next-generation optoelectronic devices.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

WE-D-17A-02: Evaluation of a Two-Dimensional Optical Dosimeter On Measuring Lateral Profiles of Proton Pencil Beams

Purpose: To evaluate the accuracy of a two-dimensional optical dosimeter on measuring lateral profiles for spots and scanned fields of proton pencil beams. Methods: A digital camera with a color image senor was utilized to image proton-induced scintillations on Gadolinium-oxysulfide phosphor reflected by a stainless-steel mirror. Intensities of three colors were summed for each pixel with proper spatial-resolution calibration. To benchmark this dosimeter, the field size and penumbra for 100mm square fields of singleenergy pencil-scan protons were measured and compared between this optical dosimeter and an ionization-chamber profiler. Sigma widths of proton spots in air were measured and compared between this dosimeter and a commercial optical dosimeter. Clinical proton beams with ranges between 80 mm and 300 mm at CDH proton center were used for this benchmark. Results: Pixel resolutions vary 1.5% between two perpendicular axes. For a pencil-scan field with 302 mm range, measured field sizes and penumbras between two detection systems agreed to 0.5 mm and 0.3 mm, respectively. Sigma widths agree to 0.3 mm between two optical dosimeters for a proton spot with 158 mm range; having widths of 5.76 mm and 5.92 mm for X and Y axes, respectively. Similar agreements were obtained for others beam ranges. This dosimeter was successfully utilizing on mapping the shapes and sizes of proton spots at the technical acceptance of McLaren proton therapy system. Snow-flake spots seen on images indicated the image sensor having pixels damaged by radiations. Minor variations in intensity between different colors were observed. Conclusions: The accuracy of our dosimeter was in good agreement with other established devices in measuring lateral profiles of pencil-scan fields and proton spots. A precise docking mechanism for camera was designed to keep aligned optical path while replacing damaged image senor. Causes for minor variations between emitted color lights will be investigated.

60 APPLIED LIFE SCIENCES↗

Three-dimensional imaging of copper pillars using x-ray tomography within a scanning electron microscope: A simulation study based on synchrotron data

While microelectronic devices are frequently characterized with surface-sensitive techniques having nanometer resolution, interconnections used in 3D integration require 3D imaging with high penetration depth and deep sub-micrometer spatial resolution. X-ray tomography is well adapted to this situation. In this context, the purpose of this study is to assess a versatile and turn-key tomographic system allowing for 3D x-ray nanotomography of copper pillars. The tomography tool uses the thin electron beam of a scanning electron microscope (SEM) to provoke x-ray emission from specific metallic targets. Then, radiographs are recorded while the sample rotates in a conventional cone beam tomography scheme that ends up with 3D reconstructions of the pillar. Starting from copper pillars data, collected at the European Synchrotron Radiation Facility, we build a 3D numerical model of a copper pillar, paying particular attention to intermetallics. This model is then used to simulate physical radiographs of the pillar using the geometry of the SEM-hosted x-ray tomography system. Eventually, data are reconstructed and it is shown that the system makes it possible the quantification of 3D intermetallics volume in copper pillars. The paper also includes a prospective discussion about resolution issues.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗