Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “SCAN”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Imaging Supramolecular Morphogenesis with Confocal Laser Scanning Microscopy at Elevated Temperatures

The morphogenesis of supramolecular assemblies is a highly dynamic process that has only recently been recognized, and our understanding of this phenomenon will require imaging techniques capable of crossing scales. Shape transformations depend both on the complex energy landscapes of supramolecular systems and the kinetically controlled pathways that define their structures and functions. We report here the use of confocal laser scanning microscopy coupled with a custom-designed variable-temperature sample stage that enables in situ observation of such shape changes. The submicrometer resolution of this technique allows for real-time observation of the nanostructures in the native liquid environments in which they transform with thermal energy. We use this technique to study the temperature-dependent morphogenic behavior of peptide amphiphile nanofibers and photocatalytic chromophore amphiphile nanoribbons. Furthermore, the variable-temperature confocal microscopy technique demonstrated in this work can sample a large volume and provides real-time information on thermally induced morphological changes in the solution.

36 MATERIALS SCIENCE↗

Performance and characterization of the prototype nm-scale spatial resolution scanning multilayer Laue lenses microscope

Synchrotron based x-ray microscopy established itself as a prominent tool for noninvasive investigations in many areas of science and technology. Many facilities around the world routinely achieve sub-micrometer resolution with a few instruments capable of imaging with the spatial resolution better than 100 nm. With an ongoing effort to push the 2D/3D resolution down to 10 nm in the hard x-ray regime both fabrication of the nano-focusing optics and stability of a microscope become extremely challenging. In this work we present our approach to overcome technical challenges on the path towards high spatial resolution hard x-ray microscopy and demonstrate the performance of a scanning fluorescence microscope equipped with the multilayer Laue lenses focusing optics.

36 MATERIALS SCIENCE↗

The Ehrlich–Schwoebel barrier on an oxide surface: a combined Monte-Carlo and in situ scanning tunneling microscopy approach

The controlled growth of epitaxial films of complex oxides requires an atomistic understanding of key parameters determining final film morphology, such as termination dependence on adatom diffusion, and height of the Ehrlich–Schwoebel (ES) barrier. In this study, through an in situ scanning tunneling microscopy study of mixed-terminated La 5/8 Ca 3/8 MnO 3 (LCMO) films, we image adatoms and observe pile-up at island edges. Image analysis allows determination of the population of adatoms at the edge of islands and fractions on A-site and B-site terminations. A simple Monte-Carlo model, simulating the random walk of adatoms on a sinusoidal potential landscape using Boltzmann statistics is used to reproduce the experimental data, and provides an estimate of the ES barrier as ~0.18 ± 0.04 eV at T = 1023 K, similar to those of metal adatoms on metallic surfaces. In conclusion, these studies highlight the utility of in situ imaging, in combination with basic Monte-Carlo methods, in elucidating the factors which control the final film growth in complex oxides.

36 MATERIALS SCIENCE↗

Imaging the spatial form of a superconducting order parameter via Josephson scanning tunneling spectroscopy

Motivated by recent experiments, we investigate Josephson scanning tunneling spectroscopy in an s-wave superconductor. Here, we demonstrate that the spatial oscillations in the superconducting order parameter induced by defects can be spatially imaged through local measurements of the critical Josephson current, providing unprecedented insight into the nature of superconductivity. The spatial form of the Josephson current reflects the nature of the defects, and can be used to probe defect-induced phase transitions from an S = 0 to an S = 1/2 ground state.

Graham, Martin↗

Building and exploring libraries of atomic defects in graphene: Scanning transmission electron and scanning tunneling microscopy study

The presence and configurations of defects are primary components determining materials functionality. Their population and distribution are often nonergodic and dependent on synthesis history, and therefore rarely amenable to direct theoretical prediction. Here, dynamic electron beam–induced transformations in Si deposited on a graphene monolayer are used to create libraries of possible Si and carbon vacancy defects. Deep learning networks are developed for automated image analysis and recognition of the defects, creating a library of (meta) stable defect configurations. Density functional theory is used to estimate atomically resolved scanning tunneling microscopy (STM) signatures of the classified defects from the created library, allowing identification of several defect types across imaging platforms. This approach allows automatic creation of defect libraries in solids, exploring the metastable configurations always present in real materials, and correlative studies with other atomically resolved techniques, providing comprehensive insight into defect functionalities.

36 MATERIALS SCIENCE↗

W-Band Scanning ARM Cloud Radar (WSACR) Multiple Elevation PPI Scan (a1-level)

The wsacr PCM process executed by the sacr3 binary reads in wsacr.00 data and produces CF/Radial compliant NetCDF files for each of the radar operational scanning modes. This incorporates raw data from the radar, as well as scientifically important base derived parameters that affect interpretation of the data.

54 ENVIRONMENTAL SCIENCES↗

Directed flow of quarks from the RHIC Beam Energy Scan measured by STAR

Directed flow (ν 1 ) is a good probe of the early-stage dynamics of collision systems, and the ν 1 slope at midrapidity ( dv 1 /dy| y=0 ) is sensitive to the system's equation of state. STAR has published ν 1 (y) measurements for ten particle species (π ± ,$p, \bar{p},Λ,\bar{Λ},ϕ,K^± and K_S^0$) in Au+Au collisions at eight beam energies from $ \sqrt{s_{NN}}$ = 7.7 GeV to 200 GeV. In this study, we employ a simple coalescence idea to decompose ν 1 of hadrons into ν 1 of constituent quarks. The dv 1 /dy values of $\bar{p},\bar{K},$ and $\bar{Λ}$ are used to test the coalescence sum rule for produced quarks. Data involving produced quarks support the coalescence picture at $ \sqrt{s_{NN}}$ =11.5 GeV to 200 GeV, and a sharp deviation from this picture is observed at 7.7 GeV. The dv 1 /dy of transported quarks is studied via net particles (net p and net Λ). In these proceedings, we further extract the ν 1 slopes of produced and transported quarks, assuming that the coalescence sum rule is valid.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Comparison of image noise and image quality between full-dose abdominal computed tomography scans reconstructed with weighted filtered back projection and half-dose scans reconstructed with improved sinogram-affirmed iterative reconstruction (SAFIRE*)

Purpose: To retrospectively compare the image noise, signal-to-noise ratio (SNR), and subjective image quality between CT images acquired with a dual-source, split-dose imaging protocol reconstructed at full and half doses with weighted filtered back projection (wFBP) and an improved sinogram-affirmed iterative reconstruction algorithm (SAFIRE*). Methods: Fifty-three consecutive patients underwent contrast-enhanced CT of the abdomen using a standardized dual-source, single energy CT protocol. Half-dose images were retrospectively generated using data from one detector only. Full-dose datasets were reconstructed with wFBP, while half-dose datasets were reconstructed with wFBP and SAFIRE* strengths 1–5. Region of interest analysis was performed to assess SNR and noise. Diagnostic acceptability, subjective noise, and spatial resolution were graded on a 10-point scale by two readers. Statistical analysis was carried out with repeated measures analysis of variance, Wilcoxon signed rank test, and Cohen’s κ test. Results: With the increasing strengths of SAFIRE*, a progressive reduction in noise and increase in SNR (p < 0.01) was observed. There was a statistically significant decrease in objective noise and increase in SNR in half-dose SAFIRE* strength 4 and 5 reconstructions compared to full-dose reconstructions using wFBP (p < 0.01). Qualitative analysis revealed a progressive increase in diagnostic acceptability, decrease in subjective noise and increase in spatial resolution for half-dose images reconstructed with the increasing strengths of SAFIRE* (p < 0.01). Conclusions: Half-dose CT images reconstructed with SAFIRE* at strength 4 and 5 have superior image quality compared to full-dose images reconstructed with wFBP. SAFIRE* potentially allows dose reductions in the order of 50% over wFBP.

62 RADIOLOGY AND NUCLEAR MEDICINE↗