Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Rooftop”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Interferometric Polarization Control

A signal conditioning module provides a polarimeter capability in a photometric system. The module may include multiple variable delay polarization modulators. Each modulator may include an input port, and a first arm formed to include a first reflector and first rooftop mirror arranged in opposed relationship. The first reflector may direct an input radiation signal to the first rooftop mirror. Each modulator also may include an output port and a second arm formed to include a second reflector and second rooftop mirror arranged in opposed relationship. The second reflector can guide a signal from the second rooftop mirror towards the output port to provide an output radiation signal. A beamsplitting grid may be placed between the first reflector and the first rooftop mirror, and also between the second reflector and the second rooftop mirror. A translation apparatus can provide adjustment relative to optical path length vis-a-vis the first arm, the second arm and the grid.

Chuss, David T.↗

Interferometric polarization control

A signal conditioning module provides a polarimeter capability in a photometric system. The module may include multiple variable delay polarization modulators. Each modulator may include an input port, and a first arm formed to include a first reflector and first rooftop mirror arranged in opposed relationship. The first reflector may direct an input radiation signal to the first rooftop mirror. Each modulator also may include an output port and a second arm formed to include a second reflector and second rooftop mirror arranged in opposed relationship. The second reflector can guide a signal from the second rooftop mirror towards the output port to provide an output radiation signal. A beamsplitting grid may be placed between the first reflector and the first rooftop mirror, and also between the second reflector and the second rooftop mirror. A translation apparatus can provide adjustment relative to optical path length vis-a-vis the first arm, the second arm and the grid.

Wollack, Edward J.↗

Interferometric polarization control

A signal conditioning module provides a polarimeter capability in a photometric system. The module may include multiple variable delay polarization modulators. Each modulator may include an input port, and a first arm formed to include a first reflector and first rooftop mirror arranged in opposed relationship. The first reflector may direct an input radiation signal to the first rooftop mirror. Each modulator also may include an output port and a second arm formed to include a second reflector and second rooftop mirror arranged in opposed relationship. The second reflector can guide a signal from the second rooftop mirror towards the output port to provide an output radiation signal. A beamsplitting grid may be placed between the first reflector and the first rooftop mirror, and also between the second reflector and the second rooftop mirror. A translation apparatus can provide adjustment relative to optical path length vis-a-vis the first arm, the second arm and the grid.

Wollack, Edward J.↗

Understanding the Evolution of Customer Motivations and Adoption Barriers in Residential Solar Markets: Survey Data

This research focused on accelerating solar photovoltaic (PV) diffusion by collecting new market data and developing predictive modeling frameworks to test and refine understandings of household level motivations for adopting solar. Three different household-level surveys were fielded: one for households who had installed PV on their current home or had signed a contract to do so (the Adopter survey), one for households that had seriously considered PV but had not installed it (the Considerer survey), and one for the general population who did not have PV on their current home (the general population survey or GPS). Survey respondents were from four U.S. states: New Jersey, New York, Arizona, and California. Details of recruiting and sampling are documented below. Research projects on residential PV adoption often collect data only from PV adopters or from the general population. One of the innovations of this project was the three-pronged household survey data collection. By collecting similar data from three fairly different "statuses" with respect to adoption, the surveys provide a basis for understanding how those who do not have rooftop PV differ from those who have, for how and why people do (or don't) transition from not having to having rooftop PV on their home, and for understanding the characteristics and viewpoints of households who have scarcely, or not at all, entered the "PV consideration" track. All three surveys covered single-family owner-occupied households in each of the four target states used in the project -- Arizona, California, New Jersey, and New York - allowing a comparative approach to understanding how the factors that affect PV adoption vary by geography and policy conditions. The General Population and Considerer surveys provide a basis for understanding opinions about and interest in solar, and how these relate to household demographics and other conditions. Paired with the Adopter survey, they also provide data for understanding how those who do not have rooftop PV differ from those who have, and for how and why people do (or don't) transition from not having to having rooftop PV on their home. The Adopter survey questions were designed to capture a broad range of information on what motivates and impedes households to install rooftop PV, as well as the details and timing of the decision and installation. Survey instrument development drew from existing PV adoption survey instruments, PV adoption literature, and research team experience, as well as from past work on household interest in energy efficiency, environmental attitudes, purchasing tendencies, and related knowledge. Early interviews and discussions with installers and others in the PV industry were also taken into consideration.

14 SOLAR ENERGY↗

Empirically Derived Strength of Residential Roof Structures for Solar Installations

Engineering certification for the installation of solar photovoltaic (PV) modules on wood roofs is often denied because existing wood roofs do not meet structural design codes. This work is intended to show that many roofs are actually sufficiently strong given the conservatism in codes, documented allowable strengths, roof structure system effects, and beam composite action produced by joist-sheathing interaction. This report provides results from a testing program to provide actual load carrying capacity of residential rooftops. The results reveal that the actual load carrying capacity of structural members and systems tested are significantly stronger than allowable loads provided by the International Residential Code (IRC 2009) and the national structural code found in Minimum Design Loads for Buildings and Other Structures (ASCE 7-10). Engineering analysis of residential rooftops typically ignores the system affects and beam composite action in determining rooftop stresses given a potential PV installation. This extreme conservatism combined with conservatism in codes and published allowable stress values for roof building materials (NDS 2012) lead to the perception that well built homes may not have adequate load bearing capacity to enable a rooftop PV installation. However, based on the test results presented in this report of residential rooftop structural systems, the actual load bearing capacity is several times higher than published values (NDS 2012).

Dwyer, Stephen F.↗

2021 Prototype Design Development Awardee: Accelerate Wind, Inc.

In the United States, rooftop photovoltaic systems can be installed on most commercial buildings. However, even if all available rooftop space is used, solar energy cannot satisfy the building's total energy demand. With many building owners trying to move toward net-zero-carbon-emission energy generation, these customers often have no way to achieve this goal on-site. Rooftop wind energy technology could be an option, but most rooftop wind turbines are not economically viable because they do not produce meaningful amounts of energy and are not likely to pay for themselves within their lifetime. Some rooftop wind turbine companies have attempted to exploit the fact that wind naturally speeds up at the edge of a roof; but, so far, these solutions have also struggled to produce significant energy because only a small portion of that wind can be captured so close to the edge of the roof.

CIP↗

Observations and Lessons Learned From Installing Residential Roofing-Integrated Photovoltaics

Building-sited solar photovoltaics (PV) could play a key role in decarbonizing the building sector either through racked and mounted PV or through Building-integrated PV (BIPV). BIPV is installed into the building envelope itself, with solar cells and/or modules forming the outer layer of a building structure, thus transforming a single-purpose structure into one that serves the dual purposes of the building envelope and electricity. BIPV can be applied to building roofs, facades, awnings, pergolas, windows, skylights, balustrades, and other external surfaces. Given BIPV products vary widely, the focus of this research is residential roofing integrated PV (RIPV), where solar is incorporated into or otherwise replaces the roofing material. Previous research suggests that residential RIPV could reduce customer acquisition, labor, supply chain, and equipment costs. These products have yet to realize these cost savings and deployment remains significantly less than conventional rooftop PV as a relative share of the addressable market in the US. One potential barrier to broader residential roofing integrated PV deployment may be higher costs relative to conventional rooftop PV, primarily because the design and installation of these products is still evolving. Here, we explore residential RIPV cost-reduction opportunities by analyzing installation processes. Our study documents residential RIPV installations at 2 reroofing sites and the equivalent of 9 new construction sites in California through a methodology known as time and motion study. We also conducted interviews with subject-matter experts to identify barriers and solutions to maximize these products' market penetration. Our time and motion study breaks the RIPV installation process into four steps: 1) staging, unloading, and roof preparation; 2) fire resistant underlayment(s) (synthetic material laid between roof shingles and roof deck); 3) flashings and PV installation; and 4) wiring and monitoring. We measure the time required for each step in terms of worker-hours, representing an hour of labor from a single worker. We further normalize process time by dividing worker-hours by kilowatt (kW) of system capacity. The most time-intensive step was flashings and PV installation, taking around 2.4 worker-hours per kW on average and accounting for around 60% of the process time for an average installation. The total installation process took on average about 6.4 and 3.5 worker-hours per kW at the reroofing sites and new construction sites, respectively. For comparison, a previous time and motion study documented a time of 6.9 worker-hours per kW for conventional rooftop PV. The shorter RIPV installation times are consistent with previous studies suggesting that RIPV could be installed faster than conventional rooftop PV. The time and motion results and feedback from interviewees provide insights into potential residential RIPV cost reduction opportunities. Several interviewees suggested that these products would be more efficient if PV installation was more fully integrated into the roofing/construction industries, which currently use separate supply chains and skillsets. Further integration could reduce supply chain delays and labor force redundancies. Future research could explore specific ways to integrate these industries to help realize the cost savings potential of RIPV.

14 SOLAR ENERGY↗

Pueblo of Laguna Village Community Solar

The project was to install approximately 11.44 kilowatts (kW) rooftop solar photovoltaic (PV) system on the Mesita Village Community Center, an approximately 9.24 kW rooftop solar PV system on the Paguate Village Community Center, an approximately 21.56 kW rooftop solar PV system on the Paraje Village Community Center, and an approximately 11.00 kW rooftop solar PV system on the Seama Community Center, for a total of about 53.24 kW on four village community centers. The systems were expected to generate approximately 93,329 kWh annually. Installing solar PV systems on the four village community centers would have helped achieve the Pueblo of Laguna’s six energy objectives: community development (decreased utility bills, funds for other needs), economic development (training and participation in the renewable energy economy), energy reliability (future storage), community resilience (alternative sources), relationship to people and the natural world (reducing fossil fuel use), and energy sovereignty (Pueblo decision-making). Installing solar PV systems would have also met specific project goals to offset not less than 85% of each selected building’s annual electricity use, ranging from 87% to 103% of demand; save a minimum of 70% of the cost of utility bills per year for each building, ranging from 75% to 77% percent (including service charges); and would have had payback periods shorter than the estimated useful life of the project

14 SOLAR ENERGY↗

A Pilot Study of the Effectiveness of Indoor Plants for Removal of Volatile Organic Compounds in Indoor Air in a Seven-Story Office Building

The Paharpur Business Centre and Software Technology Incubator Park (PBC) is a 7 story, 50,400 ft{sup 2} office building located near Nehru Place in New Delhi India. The occupancy of the building at full normal operations is about 500 people. The building management philosophy embodies innovation in energy efficiency while providing full service and a comfortable, safe, healthy environment to the occupants. Provision of excellent Indoor Air Quality (IAQ) is an expressed goal of the facility, and the management has gone to great lengths to achieve it. This is particularly challenging in New Delhi, where ambient urban pollution levels rank among the worst on the planet. The approach to provide good IAQ in the building includes a range of technical elements: air washing and filtration of ventilation intake air from rooftop air handler, the use of an enclosed rooftop greenhouse with a high density of potted plants as a bio-filtration system, dedicated secondary HVAC/air handling units on each floor with re-circulating high efficiency filtration and UVC treatment of the heat exchanger coils, additional potted plants for bio-filtration on each floor, and a final exhaust via the restrooms located at each floor. The conditioned building exhaust air is passed through an energy recovery wheel and chemisorbent cartridge, transferring some heat to the incoming air to increase the HVAC energy efficiency. The management uses 'green' cleaning products exclusively in the building. Flooring is a combination of stone, tile and 'zero VOC' carpeting. Wood trim and finish appears to be primarily of solid sawn materials, with very little evidence of composite wood products. Furniture is likewise in large proportion constructed from solid wood materials. The overall impression is that of a very clean and well-kept facility. Surfaces are polished to a high sheen, probably with wax products. There was an odor of urinal cake in the restrooms. Smoking is not allowed in the building. The plants used in the rooftop greenhouse and on the floors were made up of a number of species selected for the following functions: daytime metabolic carbon dioxide (CO{sub 2}) absorption, nighttime metabolic CO{sub 2} absorption, and volatile organic compound (VOC) and inorganic gas absorption/removal for air cleaning. The building contains a reported 910 indoor plants. Daytime metabolic species reported by the PBC include Areca Palm, Oxycardium, Rubber Plant, and Ficus alii totaling 188 plants (21%). The single nighttime metabolic species is the Sansevieria with a total of 28 plants (3%). The 'air cleaning' plant species reported by the PBC include the Money Plant, Aglaonema, Dracaena Warneckii, Bamboo Palm, and Raphis Palm with a total of 694 plants (76%). The plants in the greenhouse (Areca Palm, Rubber Plant, Ficus alii, Bamboo Palm, and Raphis Palm) numbering 161 (18%) of those in the building are grown hydroponically, with the room air blown by fan across the plant root zones. The plants on the building floors are grown in pots and are located on floors 1-6. We conducted a one-day monitoring session in the PBC on January 1, 2010. The date of the study was based on availability of the measurement equipment that the researchers had shipped from Lawrence Berkeley National Lab in the U.S.A. The study date was not optimal because a large proportion of the regular building occupants were not present being New Year's Day. An estimated 40 people were present in the building all day during January 1. This being said, the building systems were in normal operations, including the air handlers and other HVAC components. The study was focused primarily on measurements in the Greenhouse and 3rd and 5th floor environments as well as rooftop outdoors. Measurements included a set of volatile organic compounds (VOCs) and aldehydes, with a more limited set of observations of indoor and outdoor particulate and carbon dioxide concentrations. Continuous measurements of Temperature (T) and relative humidity (RH) were made selected indoor and outdoor locations.

54 ENVIRONMENTAL SCIENCES↗

Threatened and Endangered Species Survey for Patrick Air Force Base, Florida

A review of previous environmental work conducted at Patrick Air Force Base (PAFB) indicated that several threatened, endangered, or species of special concern occurred or had the potential to occur there. This study was implemented to collect more information on protected species at PAFB. A map of landcover types was prepared for PAFB using aerial photography, groundtruthing, and a geographic information system (GIS). Herbaceous vegetation was the most common vegetation type. The second most abundant vegetation type was disturbed shrubs/exotics. The beach and associated dune vegetation comprised 3.2% of the land area, but was the most extensive natural community within PAFB. A few isolated mangrove communities exist along the Banana River. Seventy-seven species of vascular plants occurred on the dunes, including four species listed by state agencies: spider lily (Hymenocallis latifolia), prickly pear cactus (Opuntia stricta), beach star (Remirea maritima), and inkberry (Scaevola plumien). Surveys of other habitats revealed eighty-four species of vascular plants including two state-listed species: spider lily and prickly pear cactus. Many of these areas are dominated by invasive, exotic species, particularly Brazilian pepper (Schinus terebinthifolius) and Australian pine (Casuarina equisetifolia), and native species of open or disturbed sites such as camphorweed (Heterotheca subaxillaris) and beardgrass (Andropogon spp.). Due to the isolation of PAFB from other natural areas, most exotic plant populations on the base are not an immediate threat to intact native plant communities. Dune habitat was surveyed for the southeastem beach mouse (Peromyscus polionotus niveiventris) by quarterly trapping along eight 100 m transects. No beach mice were found. The limited extent of dune habitat, its fragmented condition, and the isolation of PAFB from extant populations of the beach mouse probably accounts for its absence. Surveys of birds on PAFB found an avifauna characteristic of species that occur in the Indian River Lagoon system. Twenty-five species of waterbirds were observed during quarterly surveys on PAFB, including five species listed as species of special concern by the state of Florida: Snowy Egret (Egretta thula), Little Blue Heron (Egretta caerulea), Tricolored Heron (Egretta tricolo4, White Ibis (Eudocimus albus), and Brown Pelican (Pelecanus occidentalis). The Golf Course was used extensively by almost all species of waterbirds on PAFB. Twenty-two species of shorebirds were observed on PAFB. Although no listed species were observed, the potential exists for several protected species of shorebirds to use the beach at PAFB during some parts of the year. The Airfield runways and associated grass areas were important sites at PAFB for loafing and feeding for some shorebirds. Surveys of rooftop nesting by Least Terns (Stema antillarum) on PAFB found a large colony on a rooftop in the PAFB Industrial Area. This colony produced some independent young. Two rooftop Least Tern colonies reported from previous years were inactive during 1996. A small number of Black Skimmers (Rhynchops nigee attempted to nest at the Least Ten colony but were unsuccessful. Surveys for the gopher tortoise (Gopherus polyphemus) revealed burrows and tortoises only at the Waste Study Site; five burrows and three tortoises were observed. No Florida scrub lizards (Sceloporus woodi), eastern indigo snakes (Drymarchon corais couperl), or diamondback terrapins (Malademys terrapin terrapin) were observed. American alligators (Alligator mississippiensis) were observed on the Golf Course and using ditches, ponds, and areas along the Banana River. The amount of dune habitat could be expanded by not mowing areas adjacent to the dunes to allow dune species to colonize and expand. Planting dune species as part of the beach renourishment project will also increase this habitat. Exotic plants dominate several areas on the base and are used by threatened, endangered, and species of special concern. However, the use of native vegetation in landscaping projects throughout the base would improve habitat for wildlife, and invasive, exotic plants should not be used in any horticultural plantings. Water quality of ponds, ditches, and canals is important for waterbirds; it should be maintained and protected from contamination. Nesting Least Terns are sensitive to disturbance; rooftops used for nesting should be protected from disturbance. Monitoring of Least Tern and Black Skimmer nesting should be continued to determine what roofs are being used and whether nesting is successful. Furthermore, based on the large numbers of waterbirds observed on PAFB, continued monitoring of them is recommended.

Oddy, Donna M.↗

Effects of Solar Photovoltaic Panels on Roof Heat Transfer

Building Heating, Ventilation and Air Conditioning (HVAC) is a major contributor to urban energy use. In single story buildings with large surface area such as warehouses most of the heat enters through the roof. A rooftop modification that has not been examined experimentally is solar photovoltaic (PV) arrays. In California alone, several GW in residential and commercial rooftop PV are approved or in the planning stages. With the PV solar conversion efficiency ranging from 5-20% and a typical installed PV solar reflectance of 16-27%, 53-79% of the solar energy heats the panel. Most of this heat is then either transferred to the atmosphere or the building underneath. Consequently solar PV has indirect effects on roof heat transfer. The effect of rooftop PV systems on the building roof and indoor energy balance as well as their economic impacts on building HVAC costs have not been investigated. Roof calculator models currently do not account for rooftop modifications such as PV arrays. In this study, we report extensive measurements of a building containing a flush mount and a tilted solar PV array as well as exposed reference roof. Exterior air and surface temperature, wind speed, and solar radiation were measured and thermal infrared (TIR) images of the interior ceiling were taken. We found that in daytime the ceiling surface temperature under the PV arrays was significantly cooler than under the exposed roof. The maximum difference of 2.5 C was observed at around 1800h, close to typical time of peak energy demand. Conversely at night, the ceiling temperature under the PV arrays was warmer, especially for the array mounted flat onto the roof. A one dimensional conductive heat flux model was used to calculate the temperature profile through the roof. The heat flux into the bottom layer was used as an estimate of the heat flux into the building. The mean daytime heat flux (1200-2000 PST) under the exposed roof in the model was 14.0 Watts per square meter larger than under the tilted PV array. The maximum downward heat flux was 18.7 Watts per square meters for the exposed roof and 7.0 Watts per square meters under the tilted PV array, a 63% reduction due to the PV array. This study is unique as the impact of tilted and flush PV arrays could be compared against a typical exposed roof at the same roof for a commercial uninhabited building with exposed ceiling and consisting only of the building envelope. Our results indicate a more comfortable indoor environment in PV covered buildings without HVAC both in hotter and cooler seasons.

Dominguez, A.↗

Utilization of Unmanned Aircraft Systems for Environmental Purposes at the Savannah River Site – 26578

Born in the 1950s, the Savannah River Plant was constructed as a plutonium and tritium production plant. As the Cold War era came and went, a change of direction was signaled when the name of the facility changed from Savannah River Plant to Savannah River Site (1989) – the main mission at Savannah River shifted from “production” to “cleanup.” The Department of Energy is responsible for managing the 310 square miles of land that is the Savannah River Site and the cleanup/remediation activities that occur. The Savannah River National Laboratory utilizes unmanned aircraft systems to assist with some of those environmental monitoring and remediation activities. One function of unmanned aircraft systems at the Savannah River National Laboratory is conducting aerial photography and videography. Various infrastructure evaluations have been performed with unmanned aircraft – facility rooftop inspections, water tower lock verifications, earthen dam surveys, etc. An unmanned aircraft system has been used for progress footage of remediation projects – Dunbarton Bay remediation, Saltstone Disposal Unit construction, etc. Thermal cameras on an unmanned aircraft system are used to help identify cracks/leaks in structures from vantage points not readily accessible by personnel. Virtual tours of different waste units are conducted with unmanned aircraft systems for Site groups and federal/state regulators to save costs and travel time. Additionally, advanced remote sensing technologies are used on unmanned aircraft systems at the Savannah River Site. Light Detection and Ranging uses laser pulses to measure distances to the Earth's surface or other targets to create highly detailed topographic maps that accurately portray terrain (e.g., elevation changes, slopes, and contours). Data collection with a Light Detection and Ranging unit mounted on an unmanned aircraft system is quick and efficient – large-area surveys are conducted in shorter time frames. Because Light Detection and Ranging can penetrate through foliage and vegetation to ground level, it is being used in conjunction with a watershed model to study the General Separations Area of the Site to determine stormwater flow volume and direction, monitor stream stability, and forecast river flow behavior. A hyperspectral camera captures a wide spectrum of electromagnetic wavelengths across numerous narrow bands, beyond what the human eye can see. It provides detailed spectral information about the objects or surfaces in an image, which can be used to identify and analyze materials based on their spectral signatures. A hyperspectral camera mounted on an unmanned aircraft system has been used at the Savannah River Site for non-destructive evaluation of concrete and concrete structures. Unmanned aircraft systems at the Savannah River Site are also used for the application of herbicide on identified rooftops. P-Reactor and R-Reactor are entombed nuclear reactors at the Savannah River Site. Unwanted vegetation is often present on these rooftops – over time roots can penetrate seams, cracks, and joints of the general roof and concrete caps, leading to water ingress and deterioration of the structural components. For time and cost efficiencies as well as in the interest of personnel safety, an unmanned aircraft is used to dispense herbicide on rooftop areas where vegetation is noticed to help alleviate the issues/hazards.

Lorier, Troy [Savannah River National Laboratory (↗

Tribal Renewable Energy Report - Final Report: Bishop Paiute Tribe Residential Solar Program. Phase 1 (DOE Award # DE-EE0006949)

The objective of the project was to provide affordable renewable energy to 22 low income reservation homeowners; provide job training to tribal members and reduce air pollution by equivalent carbon offsets. The project exceeded grant objectives installing 66kW of rooftop solar on 22 low income single family homes and providing hands-on PV rooftop solar installation training to 24 tribal individuals (four more than planned). The project was a phased installment of an on-going partnership between the Tribe and GRID that was initiated in 2013 whereby 62 rooftop solar units were installed prior to this funded effort. The reported work in this report describes the funded effort where US Department of Energy provided partial funding through grant award IE0006949 and marks the first phase of an effort matching California Solar SASH Initiative funding with DOE Office of Indian Energy Funding and brings the total for the program to 84 installed systems (running total of 271 Kw installed) and the end of the project. Tribal workforce development was a key aspect of the project and trained 24tribal members for a total 1168 cumulative on-job training hours. The solar installations and training efforts were fully completed by September of 2016 with 66.6 kW installed - 8 kW more than the original estimate stated in the grant application.

14 SOLAR ENERGY↗

Estimating and parameterizing mismatch power loss in bifacial photovoltaic systems

Nonuniform irradiance on the rear side of bifacial photovoltaic (PV) systems can cause additional mismatch loss, which may not be appropriately captured in PV energy production estimates and software. We evaluated several scenarios including horizontal single-axis tracking (HSAT) over natural ground-cover and rooftop-mounted systems over high albedo reflective roofs. We found mismatch losses of up to 1.5% annual loss for very close-mounted (0.15 m) rooftop systems, but losses for HSAT systems and high-ground-clearance rooftop systems were lower (<0.5%). A simplified empirical relationship was found that links the spatial variation of irradiance (specifically, the mean absolute difference of irradiance) to the resulting mismatch loss factor, with an R 2 better than .99. Furthermore, this approximate relationship was experimentally validated on mismatched PV modules, and it provides a basis for rapidly estimating bifacial mismatch loss factors for use in hourly PV performance simulations such as PVSyst or SAM. Additional parameters investigated include (a) climate dependence and module orientation, which were not found to have a strong impact on bifacial mismatch losses and (b) PV module fill factor and bifaciality ratio, which did have a strong linear impact on mismatch losses.

14 SOLAR ENERGY↗

Impact of residential PV adoption on Retail Electricity Rates

The price of electricity supplied from home rooftop photo voltaic (PV) solar cells has fallen below the retail price of grid electricity in some areas. A number of residential households have an economic incentive to install rooftop PV systems and reduce their purchases of electricity from the grid. A significant portion of the costs incurred by utility companies are fixed costs which must be recovered even as consumption falls. Electricity rates must increase in order for utility companies to recover fixed costs from shrinking sales bases. Increasing rates will, in turn, result in even more economic incentives for customers to adopt rooftop PV. In this paper, we model this feedback between PV adoption and electricity rates and study its impact on future PV penetration and net-metering costs. We find that the most important parameter that determines whether this feedback has an effect is the fraction of customers who adopt PV in any year based solely on the money saved by doing so in that year, independent of the uncertainties of future years. These uncertainties include possible changes in rate structures such as the introduction of connection charges, the possibility of PV prices dropping significantly in the future, possible changes in tax incentives, and confidence in the reliability and maintainability of PV. (C) 2013 Elsevier Ltd. All rights reserved.

Cai, DWH↗

Air, surface, and wastewater surveillance of SARS-CoV-2; a multimodal evaluation of COVID-19 detection in a built environment

Environmental surveillance of infectious organisms holds tremendous promise to reduce human-to-human transmission in indoor spaces through early detection. In this study we determined the applicability and limitations of wastewater, indoor high-touch surfaces, in-room air, and rooftop exhaust air sampling methods for detecting SARS-CoV-2 in a real world building occupied by residents recently diagnosed with COVID-19. We concurrently examined the results of three 24-hour environmental surveillance techniques, indoor surface sampling, exhaust air sampling and wastewater surveillance, to the known daily census fluctuations in a COVID-19 isolation dormitory. Additionally, we assessed the ability of aerosol samplers placed in the large volume lobby to detect SARS-CoV-2 multiple times per day. Our research reveals an increase in the number of individuals confirmed positive with COVID-19 as well as their estimated human viral load to be associated with statistically significant increases in viral loads detected in rooftop exhaust aerosol samples (p = 0.0413), wastewater samples (p = 0.0323,), and indoor high-touch surfaces (p < 0.001)). We also report that the viral load detected in lobby aerosol samples was statistically higher in samples collected during presence of occupants whose COVID-19 diagnostic tests were confirmed positive via qPCR compared to periods when the lobby was occupied by either contact-traced (suspected positive) individuals or during unoccupied periods (p = 0.0314 and <2e–16). We conclude that each daily (24h) surveillance method, rooftop exhaust air, indoor high-touch surfaces, and wastewater, provide useful detection signals for building owner/operator(s). Furthermore, we demonstrate that exhaust air sampling can provide spatially resolved signals based upon ventilation exhaust zones. Additionally, we find that indoor lobby air sampling can provide temporally resolved signals useful during short duration sampling periods (e.g., 2-4 hours) even with intermittent occupancy by occupants diagnosed with COVID-19.

60 APPLIED LIFE SCIENCES↗

Mitigating urban heat island and enhancing indoor thermal comfort using terrace garden

The United Nations advocates for sustainable urban planning and design, emphasizing green infrastructure initiatives to mitigate urban heat island effects and enhance the resilience and livability of cities globally. To address urban heat challenges, a study was conducted in Chennai, India, from April to June 2023. The study focused on assessing temperature dynamics on a building's terrace by comparing a well-maintained garden area with an exposed region. Temperature and humidity sensors were deployed in both the garden and exposed areas of the terrace, as well as within rooms beneath it, to monitor hourly temperature fluctuations. The findings indicate a significant reduction in internal room temperatures in areas with rooftop gardens, ranging from 4 to 11 °C, depending on the time of year and sun's position, compared to rooms with fully exposed roof configurations. Additionally, simulation studies were performed to validate these findings, suggesting that optimizing the distribution of soil beds and plant density across the roof could yield an additional temperature reduction of 3–4 °C, resulting in an overall difference of up to 14–15 °C. The study highlights the efficacy of rooftop gardens in providing cooling effects during daylight hours and maintaining temperature parity post-sunset. Through analysis of sensor data, the research elucidates the intricate relationship between green infrastructure and thermal comfort, offering insights for energy-efficient building design and resilient urban planning. The findings underscore the potential of rooftop gardens in fostering a more comfortable, energy-efficient, and sustainable urban living environment.

54 ENVIRONMENTAL SCIENCES↗

Prioritizing urban heat adaptation infrastructure based on multiple outcomes: Comfort, health, and energy

Globally, cities face increasing extreme heat, impacting comfort, health, and energy consumption. Infrastructure-based heat adaptation strategies can improve these outcomes, but each strategy has a unique mix of benefits and drawbacks. Here, we apply an urbanized meteorological model (WRF) with the newly integrated multilayer BEP-Tree street tree model to dynamically downscale Earth System Model projections and a 3-D microclimate model (TUF-Pedestrian) to simulate the street-scale radiation environment impacting pedestrians. We evaluate the performance of five heat adaptation strategies (street trees, cool roofs, green roofs, rooftop photovoltaics (PV), and reflective pavements) during extreme heat events in three cities with contrasting background climates (Toronto, Phoenix, and Miami), under contemporary and end-of-century projected climates, based on three metrics: outdoor heat stress, air conditioning (AC) energy use, and ventilation of vehicular air pollution. No single adaptation strategy improves all three outcomes. While street trees inhibit ventilation, they reduce outdoor heat stress four times more effectively than the next best strategy via shade provision, fully offsetting heat stress increases under a high-emissions end-of-century climate scenario in all cities studied. Cool roofs and green roofs moderately reduce heat stress and energy use. Alternatively, rooftop PV with energy storage can generate sufficient power for space cooling but have marginal effects on heat stress. Reflective pavements are the least effective across metrics. Where the ventilation of street-level emissions is of less concern, our results clearly support the combination of street trees and rooftop PV as a highly complementary and effective means of adaptive mitigation across different climates and neighborhood densities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗