Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building Energy Use”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

High-resolution hourly surrogate modeling framework for physics-based large-scale building stock modeling

Surrogate modeling can play a key role in reducing high computational burdens for large-scale physics-based modeling and uncertainty quantification. With the rapid development of large-scale building stock energy modeling, surrogate modeling has also begun to be widely applied in this field; however, most existing surrogate models lack hourly time resolution for regional-scale modeling, which is essential for understanding building demand profiles and grid impacts. Further, there is generally a lack of necessary data and feature engineering frameworks specific to building modeling for efficiently managing large datasets and complex computations. Furthermore, this paper proposes a modeling framework for large-scale (city-/region-scale), high-resolution, high-fidelity surrogate building stock energy models. Our developed framework consists of six modules: (1) building stock energy modeling (ComStock TM and ResStock TM ), (2) data engineering for large simulation data, (3) high performance computing workflow, (4) feature engineering, (5) machine learning model development, and (6) model performance evaluation. Two case studies apply the developed framework in both residential and commercial building stock analysis to demonstrate its computational efficiency and surrogate modeling accuracies. Results show that surrogate models, when efficiently trained using the HPC workflow module, reach a high level of modeling accuracy for two case studies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparative Performance of Low Global Warming Potential (GWP) Refrigerants as Replacement for R-410A in a Regular 2-Speed Heat Pump for Sustainable Cooling

Heat pumps are currently being developed to reduce the energy footprint for residential and commercial building space conditioning and water heating loads in cold climates. To mitigate the nocuous impact of greenhouse gas emissions on the environment, and to create a carbon-neutral building stock, alternate lower-GWP refrigerants must also replace the predominant use of R-410A, without re-engineering the mechanical hardware. In this paper, we analyze the performance of lower-GWP alternative refrigerants (R-32, R-452B, R-454B, and R-466A) relative to the conventional R-410A and draw conclusions on the relative performances to meet cooling loads. The simulations are accomplished using the heat pump design model, a well-known, public-domain design tool with a free web interface and downloadable desktop version to support public use and the HVAC R&D community. The contributions contain detailed, hardware-based heat exchanger and system analyses to provide a comprehensive assessment. The results of the simulation are scrutinized from the first (capacity and energy efficiency) and second laws (exergy analysis) to identify sources of systemic inefficiency, the root cause of lost work. This rigorous approach provides an exhaustive analysis of alternate lower-GWP refrigerants to replace R-410A using the same hardware. The results have practical value in engineering heat pumps in an economy that is compelled to alter by the consequences and uncertainties of climate change, to reduce its anthropogenic carbon footprint.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Towards a Techno-Economic Analysis of PCM Integrated Hybrid HVAC Systems

Thermal end uses dominate building energy consumption and are a major driver of peak demand. As heating is electrified, peak electrical power required will surge, prompting a need for innovative HVAC system designs and controls.These designs must incorporate novel technologies at the component level and new integration techniques at the system level. One such possibility involves the addition of thermal energy storage (TES) in heating and cooling equipment using a phase change material (PCM) heat exchanger. Here, thermal energy storage via phase change can be used to shift the HVAC system loads to times of lower electricity cost, reduced carbon intensity, and greater energy efficiency. Most of the current utilization of PCM in buildings involves passive components. By actively controlling when heat is stored and released from PCM, we can optimize the building HVAC system to cost-effectively meet consumer needs with the flexibility to draw on renewable energy resources when they are abundant and available. While this combination of technologies is promising in theory, simulation-based evaluation of a prototype can be difficult due to the modeling requirements at the component level and the large number of possible configurations and operating modes at the system level. To conduct this evaluation, we use the Modelica language for modeling and simulation because it enables users to represent the important physics of the problem, interchange and rearrange components in an efficient manner, and implement a range of control configurations. In this work, we considered three case studies: a portable building, a large commercial retail store, and a multifamily residential apartment unit. Each of these employs a different system design, ranging from a single package vertical unit incorporating PCM to a central plant with independent heat pump, evaporative cooling, and thermal energy storage components. This paper describes the technologies in question, presents modeling at the component and system levels, and demonstrates building energy and demand charge cost savings with local time-of-use tariffs in a hot-dry climate.

Helmns, Dre↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization and Analysis of the Energy-Reporting Accuracy of Connected Devices

Emerging energy-efficient building systems increasingly exhibit greater functionality, often requiring multiple operating modes (e.g. white-tunability for lighting products and data traffic for devices with networked, integrated sensors). This increased functionality makes energy consumption estimates more complex. Given that these functions consume energy, the energy performance of such building systems is dependent on what operating modes they use and how much time they spend in each mode. Devices and systems that can report their own energy consumption mitigate this energy-performance uncertainty. This study explores the energy-reporting accuracy of market-available connected electrical outlets. The study considers two residential-market products (five units each, one outlet per unit) and three commercial-market products (two units each, 18 to 24 outlets per unit) with the ability to report power drawn and/or energy consumed by devices connected to their receptacles. The products were purchased through typical market channels. Pacific Northwest National Laboratory (PNNL) conducted testing in December 2018 at its Connected Lighting Test Bed (CLTB), using a custom-developed test setup and method adapted from industry standards. The setup collected energy-consumption data reported by the outlet devices under test (DUTs) at one-minute intervals and compared that data with measurements taken by a reference meter over a range of test conditions. The residential products reported power draw but not interval or cumulative energy consumption. The commercial products reported both power draw and cumulative energy consumption. Relative reporting error (RRE) was calculated for all measurements, and analysis of the results revealed variations across devices and test conditions. The total number of measurements (50 for each residential product, 60 for each commercial product) offers an appreciable comparison of performance at the make/model level. The average RRE of the residential products derived from reported power draw was -0.02% and -1.20%. The average RRE for two of the three the commercial products derived from reported power draw was worse than those of the residential products (-2.40%, -2.72%, -0.36%). The internal integration of power over time, used to calculate cumulative energy consumption, typically occurs at current and voltage sampling rates much higher than once per minute. This suggests that the average commercial-product RRE derived from reported energy consumption should be very consistent and better than performance based on reported power draw. However, the RRE derived from reported energy consumption varied significantly across the three makes of commercial-market products and was uniformly less accurate than performance based on reported power draw. Subsequent analysis identified a number of root causes for this decrease in performance, most of which were related to reporting resolution. The goals of this study are to generate awareness of building systems capable of reporting their own energy consumption, further interest in the value of energy data for a variety of uses, draw attention to how the accuracy of reported metrics can be characterized, and quantify the performance variation found in marketavailable products. The results of this study and subsequent related work may be relevant to stakeholders in industry-specification and standards-development organizations. The methods this study employs could inform test and measurement procedures and performance classifications for connected outlets, lighting products, and other building systems capable of reporting their own energy consumption. The study concludes with stakeholder recommendations, including the following: • Energy-reporting device and system manufacturers developing products that report energy consumption should characterize the accuracy of reported metrics using a reference meter calibrated by an independent laboratory that was accredited by an ILAC MRA signatory (and whose scope of accreditation explicitly covers energy measurement), and should include this information on product data sheets. • Standards and specification development organizations should develop application-specific performance classifications that end users can understand and relate to their energy-data use needs (e.g., 2% accuracy class for utility streetlight energy billing needs, or 10% accuracy class for ESCO performance verification needs). • Current or potential owners, operators, and specifiers of energy-reporting building systems should rigorously analyze the dependency of current and planned energy-data use cases on accuracy, noting in particular the dependence (or lack thereof) on relative vs. absolute accuracy, and on trueness vs. precision (i.e., repeatability), and should communicate use-case needs to industry standards and specification organizations.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

OCHRE

OCHRE™ uses a variety of input data sources to run time-series simulations. Building models can be taken from the ResStock™ database or generated using the Building Energy Optimization Tool (BEopt™) or other OpenStudio-HPXML workflows. EV charging profiles can be taken from datasets used in NLR's 2030 National Charging Network project. Weather data can be taken from the National Solar Radiation Database or EnergyPlus® weather files. There are no public datasets with OCHRE outputs at this time. However, a recent project dataset on water heater and EV demand flexibility can be requested. OCHRE is a Python-based energy modeling tool designed to model flexible loads in residential buildings. OCHRE includes detailed models and controls for flexible devices including HVAC equipment, water heaters, EVs, solar PV, and batteries. It is designed to run in co-simulation with custom controllers, aggregators, and grid models.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Methods for Computing Physically Realistic Estimates of Electric Water Heater Demand Response Resource Suitable for Bulk Power System Planning Models

Demand response is commonly called on to reduce load during system peak times or to respond to contingency events. In future power systems with higher shares of wind and solar generation (which we describe together as variable generation [VG]), demand response could have more opportunities to provide energy shifting or operating reserve services. This report evaluates the ability of residential electric water heaters, both electric resistance water heaters (ERWHs) and heat pump water heaters (HPWHs), to provide such services starting from detailed whole-building energy models that realistically represent New England single family home stock. We use a parsimonious surrogate model to represent operational flexibility in a form suitable for linear and mixed integer programming. This enables relatively fast determination of aggregate contingency reserve resource, price-taking energy shifting outcomes, and in some cases the determination of aggregate models at the megawatt (MW) scale that can be directly included in large-scale grid models. After selecting modeling methods and parameters through various computational experiments, we find interquartile ranges of contingency reserve resource in ISO-NE for about 603,400 ERWHs of 45 MW - 69 MW for Claim10 (50 minute responses provided with 10 minutes of advanced notification) and 65 MW - 102 MW for Claim30 (30 minute responses provided with 30 minutes of advanced notification), and for about 619,000 HPWHs of 48 MW - 88 MW for Claim10 and 52 MW - 90 MW for Claim30. The overall reserve resource is up to 32% of total load for ERWHs providing Claim10 service, 47% for ERWHs providing Claim30 service, 93% for HPWHs providing Claim10 service, and 97% for HPWHs providing Claim30 service. More work is required to determine if HPWHs are inherently more suitable than ERWHs for providing contingency reserve or if these results reflect idiosyncrasies of the single family home stock model used in this study. The value of this contingency resource in a Near-term VG model of ISO-NE is $\$ 0.40$ to $\$1.20$ per water heater-year, and significantly larger, $\$ 3.80$ to $\$ 5.30$ per water heater-year in a Mid-term VG model of ISONE. Aggregating surrogate models to the MW-scale for energy shifting service is more challenging than for contingency service and we only present such results for ERWHs, because we were unable to determine satisfactory ways to deal with HPWHs' time-varying and path dependent operational characteristics. Individual surrogate models suitable for evaluating the energy shifting resource from both ERWHs and HPWHs are created, however, and dispatched against day-ahead prices from the Near-Term VG and Mid-Term VG models of ISO-NE. The individual surrogate models are able to access and potentially shift all 640 GWh of HPWH load and 1,547 GWh of ERWH load we modeled in two different single family home stock models. In contrast, the most effective model of aggregate ERWH shifting resource we created only captured 34.7% of the total ERWH load. Energy shifting affected by price-taking dispatch against modeled day-ahead energy prices produces per water heater year profits of $\$19.44$ - $\$22.93$ for individual HPWHs, $\$39.11$ - $\$40.54$ for individual ERWHs, and up to $\$4.00$ - $\$4.24$ for aggregated ERWHs, with the variations mainly due to grid conditions (more or less VG). When the supply-side response to these changes is accounted for, the per water heater year production cost savings for ISO-NE are $\$7.50$ to $\$17.70$ for the most effective set of endogenously dispatched aggregate ERWHs, $\$15.60$ to $\$15.70$ for individual ERWHs dispatched against the DA prices, and $\$10.70$ to $\$11.20$ for individual HPWHs dispatched against DA prices. Those ranges primarily represent the difference between Near-Term VG and Mid-Term VG grid conditions.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Local Resource Assessment: Beetle-Killed Spruce in Alaska

This report synthesizes forest inventory and spatial data from federal and state sources to present a snapshot of beetle-killed spruce across Southcentral and Interior Alaska. This natural resource is under investigation for use in cellulose-based products, particularly building insulation. Research funded by the Department of Energy's ARPA-E program, has successfully developed insulation - Celium - using beetle-killed spruce combined with mycelium, the root network of fungi. The resulting insulation product can be manufactured locally and used across all Alaskan climate zones for residential, commercial, and shipping applications. Removing standing dead wood also contributes to wildfire risk reduction and mitigates associated public health impacts. This Local Resource Assessment, funded by the Denali Commission, contextualizes and reconciles unaligned forestry data sources, establishing a pathway to refined, replicable analysis and, ultimately, presenting estimates of beetle-killed spruce biomass to inform the potential scale and development of a Celium industry.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Exploring the potential of non-residential solar to tackle energy injustice

Despite the observed disparities in US residential solar deployment, there is limited insight into whether these disparities exist for the non-residential sector. Here we use DeepSolar, a comprehensive photovoltaic database constructed with satellite imagery, to assess solar deployment equity based on the US Justice40’s disadvantaged community measure. We find that disadvantaged communities have less non-residential solar (–38%), but this disparity is notably higher for residential solar (–67%). Across-state variations are consistent for residential solar (–81% to –49%) yet highly heterogeneous for non-residential solar (–66% to +34%). Using scenarios to explore the potential for microgrids powered by solar on building rooftops larger than 1,000 square metres, we estimate that 63% of disadvantaged communities could meet at least 20% of annual residential electricity demand. Furthermore, our research argues for a new focus on non-residential solar as a way to strengthen resilience and accelerate local deployment of clean energy resources to promote energy justice.

14 SOLAR ENERGY↗

A Framework for Identifying Building Energy Models of Localized Utility Service Areas Using Smart Meter Data

Bottom-up load modeling of buildings offers a versatile approach to simulating baseline demand and scenarios of future technology evolution and adoption at the individual building level. This capability is essential to understanding how future load shapes may change with the adoption of electric equipment and vehicles, particularly as it relates to grid planning and infrastructure investments. Traditionally, grid planning techniques have used historical load data to predict future load and infrastructure needs. However, with the anticipated rise in adoption of electrification technologies such as heat pumps and electric vehicles, historical data become less reliable predictors of the future. By employing ResStock, a high-fidelity building stock modeling tool, we can fine-tune electrification scenarios and aggregate models to represent varying geographic resolutions of the grid system, while considering the underlying features of homes. This may enable a more accurate and responsive approach to anticipate and plan for the evolving landscape of energy demands. We present a new framework that leverages building stock energy modeling to identify building models that align with the load shapes and housing attributes of buildings with AMI data. This approach applies two model layers: (1) a classification step that identifies the presence of air conditioning, electric heating, and electric water heating, and (2) an optimization routine that identifies building energy models aligning with load profile data from advanced metering infrastructure meters. This report demonstrates one approach to deploying this framework, and presents results for three test cases that use both modeled and AMI data to assess performance. For a test case using AMI data in Fort Collins, Colorado, we observed a median monthly electricity load CV-RMSE of 16.6%, and a top ten daily heating and cooling median absolute percent error of 7.7% and 8.3%, respectively. For each AMI meter, we identify a set of potential energy models so that downstream use-cases can account for uncertainty driven by variability of baseline technologies and occupant behavior, which impact the response to electrification and energy efficiency scenarios. Our results indicate that ResStock has potential as a scalable solution for modeling residential energy demand at local grid resolutions. Its performance depends on location-specific factors, underlying building characteristics, and the level of aggregation, offering a path towards more precise and adaptive distribution grid planning for the evolving energy landscape.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Scheduling and Control of Flexible Building Loads for Grid Services Based on a Virtual Battery Model

This paper presents a framework for modeling, scheduling, and controlling residential thermostatically controlled loads (TCLs) to provide multiple grid services, such as energy shifting, peak load reduction, and ancillary services. A modeling method is proposed to characterize the aggregate flexibility from heterogeneous TCLs using a battery-equivalent model. Based on the flexibility model, a multi-period optimal scheduling formulation is developed to best utilize the flexibility from building loads and maximize total benefits from stacked value streams. An algorithm is proposed to control individual TCLs to follow the desired power consumption in real-time. The proposed methods are illustrated and validated through simulations.

Wu, Di↗

Futures for electrochromic windows on high performance houses in arid, cold climates

This study investigates high performance electrochromic windows used on a passive house and residential dwelling to IECC 2021 (i.e., IECC dwelling). In the lab, the electrochromic film switches transmitted solar heat gain coefficient (SHGC) from 0.09 to 0.7 and visible transmittance from 0.15 to 0.82 with power consumption of 1.23 W/m 2 during switching times less than 3 minutes. We extrapolate these results to a window assembly. Building energy models of the houses were evaluated in Santa Fe, New Mexico. A Monte Carlo analysis for 2020, 2040, 2060, and 2080 was conducted for Shared Socioeconomic Pathways 2-4.5, 3-7.0, and 5-8.5. Cases with and without the electrochromic windows and with and without electricity were used to determine energy use intensity and hours beyond thermal safety thresholds. The passive house showed 1.3-3.1% mean energy savings and the IECC dwelling 4.4-5.1% with electrochromic efficiency benefits growing into the future for both cases. Even so, overall savings decrease into the future for the passive house, due to growth in cooling load being dominant, conversely overall energy savings increase into the future for the IECC dwelling due to heating loads being dominant. For thermal resilience, the passive house exhibited a mean percent decrease of 0.02-0.31% hours in the extreme caution (i.e., > 32.2 °C, ≤ 39.4 °C) range while the IECC dwelling exhibited 0.38-4.38%. The study therefore shows that electrochromic windows will have smaller benefits for the passive house in comparison to the IECC dwelling. The relationship between electrochromic windows is shown to have a complex relationship between house efficiency and climate change by these results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Conditional distribution estimation of building characteristics with diffusion models for urban energy modeling

Understanding current energy consumption behavior in communities is critical for informing future energy use decisions and enabling efficient energy management. Urban energy models, which are used to simulate these energy use patterns, require large datasets with detailed building characteristics for accurate outcomes. However, such detailed characteristics at the individual building level are often unknown and costly to acquire, or unavailable. Through this work, we propose using a generative modeling approach to generate realistic building attributes to fill in the data gaps and finally provide complete characteristics as inputs to energy models. Our model learns complex, building-level patterns from training on a large-scale residential building stock model containing 2.2 million buildings. We employ a tabular diffusion-based framework that is designed to handle heterogeneous (discrete and continuous) features in tabular building data, such as occupancy, floor area, heating, cooling, and other equipment details. We develop a capability for conditional diffusion, enabling the imputation of missing building characteristics conditioned on known attributes. We conduct a comprehensive validation of our conditional diffusion model, firstly by comparing the generated conditional distributions against the underlying data distribution, and secondly, by performing a case study for a Baltimore residential region, showing the practical utility of our approach. Our work is one of the first to demonstrate the potential of generative modeling to accelerate building energy modeling workflows.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Signal Temporal Logic Control for Residential HVAC Systems to Accommodate High Solar PV Penetration

This paper proposes a new signal temporal logic (STL) control for ON/OFF residential buildings' Heating Ventilation and Air Conditioning (HVAC) systems. STL is used to control indoor temperatures while consuming most of the generated solar photovoltaic (PV) power locally to minimize its impact on the grid and reduce the need for large energy storage devices. In contrast to most, if not all, control mechanisms such as the traditional model predictive control (MPC), STL control allows for including temporal constraints in the control formulation to further relax indoor temperatures' constraints and allow them to exceed the comfort band limits for a prespecified (short) period of time. This relaxation allows to consume an additional PV power by the HVAC systems, which prevents such an unwanted intermittent power from affecting the grid. We formulate the MPC-based STL control mechanism to implement the objective. Simulation results show that the PV tracking performance has been improved while employing the proposed STL controller.

Wu, Tumin↗

Model America - Arizona extract from ORNL's AutoBEM v1.1

Oak Ridge National Laboratory (ORNL) has developed the Automatic Building Energy Modeling (AutoBEM) software suite to process multiple types of data, extract building-specific descriptors, generate building energy models, and simulate them on High Performance Computing (HPC) resources. For more information, see AutoBEM-related publications (bit.ly/AutoBEM).Two sets of sample data are provided for 2,555,152 buildings located within the boundary of Arizona in the United States:Data (846.3MB *.csv) - minimalist list of each building (rows) for the following fields (columns) • ID - unique building ID • Centroid - building center location in latitude/longitude (from Footprint2D) • Footprint2D - building polygon of 2D footprint (lat1/lon1_lat2/lon2_...) • State_abbr - state name • Area - estimate of total conditioned floor area (ft2) • Area2D - footprint area (ft2) • Height - building height (ft) • NumFloors - number of floors (above-grade) • WWR_surfaces - percent of each facade (pair of points from Footprint2D) covered by fenestration/windows (average 14.5% for residential, 40% for commercial buildings) • CZ - ASHRAE Climate Zone designation • BuildingType - DOE prototype building designation (IECC=residential) as implemented by OpenStudio-standards • Standard - building vintage • Sample Models (114GB*.zip by county) - OpenStudio and EnergyPlus building energy models named according to IDThis data is made free and openly available in hopes of stimulating any simulation-informed use case. Data is provided as-is with no warranties, express or implied, regarding fitness for a particular purpose. We wish to thank our sponsors which include Oak Ridge National Laboratory (ORNL), U.S. Dept. of Energy’s (DOE) Building Technologies Office (BTO), Office of Electricity (OE), and Biological and Environmental Research (BER).

54 ENVIRONMENTAL SCIENCES↗

Building a Just Transition to a Sustainable Energy Future

Residential and commercial buildings consume roughly 74% of U.S. electricity and are responsible for approximately 35% of carbon emissions. As a result, there is no pathway to a sustainable energy future that does not prioritize a transformation in how we use, store, and generate energy in our nation’s buildings. Consequently, the importance and timeliness of research, development, demonstration, and deployment of clean energy building technologies is more pressing than ever. However, inequities that permeate society are acutely prevalent in the energy economy, particularly in the buildings sector. Therefore, as we transition to a sustainable energy future, we should prioritize a “just transition,” where we ensure the benefits, as well as costs, are more equitably distributed. As a scientific and technical community, we should take the lead in centering equity in clean energy technology innovation by permeating equity throughout the RDD&D spectrum. This talk will discuss pathways to achieving a just transition toward a sustainable energy future. It will highlight current Department of Energy and national laboratory RDD&D efforts that advance clean energy goals. The talk will conclude by challenging the ASME community to look through a lens of equity that prioritizes an equitable distribution of benefits and costs for our sustainable energy future.

30 DIRECT ENERGY CONVERSION↗

ResStock™ v3.2.0 [SWR-19-15 and SWR-20-07]

The ResStock™ analysis tool was built on NREL's OpenStudio® platform, and is a project geared at modeling existing residential building stocks at national, regional, or local scales with a high-degree of granularity (e.g., one physics-based simulation model for every 200 dwelling units), using the EnergyPlus® simulation engine. Information about ComStock™, a sister tool for modeling the commercial building stock, can be found here: https://www.nrel.gov/buildings/comstock.html This repository contains: Housing characteristics of the U.S. residential building stock, in the form of conditional probability distributions stored as tab-separated value (.tsv) files. Comments at the bottom of each file document data sources and assumptions for each. A library of housing characteristic "options" that translate high-level characteristic parameters into arguments for OpenStudio measures, and which are referenced by the housing characteristic .tsv files and building energy upgrades defined in project definition files Project definition files: v2.3.0 and later: buildstockbatch YML files openable in any text editor v2.2.5 and prior: Project folder openable in PAT Unit-level OpenStudio Measures for automatically constructing OpenStudio Models of each representative dwelling unit model: v3.0.0 and later: OpenStudio-HPXML Measures v2.5.0 and prior: OpenStudio Measures Higher-level OpenStudio Measures for controlling simulation inputs and outputs This repository does not contain software for running ResStock simulations, which can be found as follows: Versions 2.3.0 and later only support the use of buildstockbatch for deploying simulations on high-performance or cloud computing. Version 2.3.0 also removed separate projects for single-family detached and multifamily buildings, in lieu of a combined project_national representing the U.S. residential building stock. See the changelog for more details. Versions 2.2.5 and prior support the use of the publicly available OpenStudio-PAT software as an interface for deploying simulations on cloud computing. Read the documentation for v2.2.5.

Horowitz, Scott↗