Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Residential Building”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Analysis of the Chinese Market for Building Energy Efficiency

China will account for about half of the new construction globally in the coming decade. Its floorspace doubled from 1996 to 2011, and Chinese rural buildings alone have as much floorspace as all of U.S. residential buildings. Building energy consumption has also grown, increasing by over 40% since 1990. To curb building energy demand, the Chinese government has launched a series of policies and programs. Combined, this growth in buildings and renovations, along with the policies to promote green buildings, are creating a large market for energy efficiency products and services. This report assesses the impact of China’s policies on building energy efficiency and on the market for energy efficiency in the future. The first chapter of this report introduces the trends in China, drawing on both historical analysis, and detailed modeling of the drivers behind changes in floorspace and building energy demand such as economic and population growth, urbanization, policy. The analysis describes the trends by region, building type and energy service. The second chapter discusses China’s policies to promote green buildings. China began developing building energy codes in the 1980s. Over time, the central government has increased the stringency of the code requirements and the extent of enforcement. The codes are mandatory in all new buildings and major renovations in China’s cities, and they have been a driving force behind the expansion of China’s markets for insulation, efficient windows, and other green building materials. China also has several other important policies to encourage efficient buildings, including the Three-Star Rating System (somewhat akin to LEED), financial incentives tied to efficiency, appliance standards, a phasing out of incandescent bulbs and promotion of efficient lighting, and several policies to encourage retrofits in existing buildings. In the third chapter, we take “deep dives” into the trends affecting key building components. This chapter examines insulation in walls and roofs; efficient windows and doors; heating, air conditioning and controls; and lighting. These markets have seen significant growth because of the strength of the construction sector but also the specific policies that require and promote efficient building components. At the same time, as requirements have become more stringent, there has been fierce competition, and quality has at time suffered, which in turn has created additional challenges. Next we examine existing buildings in chapter four. China has many Soviet-style, inefficient buildings built before stringent requirements for efficiency were more widely enforced. As a result, there are several specific market opportunities related to retrofits. These fall into two or three categories. First, China now has a code for retrofitting residential buildings in the north. Local governments have targets of the number of buildings they must retrofit each year, and they help finance the changes. The requirements focus on insulation, windows, and heat distribution. Second, the Chinese government recently decided to increase the scale of its retrofits of government and state-owned buildings. It hopes to achieve large scale changes through energy service contracts, which creates an opportunity for energy service companies. Third, there is also a small but growing trend to apply energy service contracts to large commercial and residential buildings. This report assesses the impacts of China’s policies on building energy efficiency. By examining the existing literature and interviewing stakeholders from the public, academic, and private sectors, the report seeks to offer an in-depth insights of the opportunities and barriers for major market segments related to building energy efficiency. The report also discusses trends in building energy use, policies promoting building energy efficiency, and energy performance contracting for public building retrofits.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Strategy Guideline. Proper Water Heater Selection

This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Trends in Residential and Commercial Buildings - August 2010

This report overviews trends in the construction industry, including profiles of buildings and the resulting impacts on energy consumption. It begins with an executive summary of the key findings found in the body of the report, so some of the data and charts are replicated in this section. Its intent is to provide in a concise place key data points and conclusions. The remainder of the report provides a specific profile of the construction industry and patterns of energy use followed by sections providing product and market insights and information on policy efforts, such as taxes and regulations, which are intended to influence building energy use. Information on voluntary programs is also offered.

commercial buildings↗

U.S. Department of Energy Commercial Reference Building Models of the National Building Stock

The U.S. Department of Energy (DOE) Building Technologies Program has set the aggressive goal of producing marketable net-zero energy buildings by 2025. This goal will require collaboration between the DOE laboratories and the building industry. We developed standard or reference energy models for the most common commercial buildings to serve as starting points for energy efficiency research. These models represent fairly realistic buildings and typical construction practices. Fifteen commercial building types and one multifamily residential building were determined by consensus between DOE, the National Renewable Energy Laboratory, Pacific Northwest National Laboratory, and Lawrence Berkeley National Laboratory, and represent approximately two-thirds of the commercial building stock.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Development of the Advanced Energy Design Guide for K-12 Schools – 50% Energy Savings

This Technical Support Document (TSD) describes the process and methodology for the development of the Advanced Energy Design Guide for K-12 School Buildings: Achieving 50% Energy Savings Toward a Net Zero Energy Building (AEDG-K12) (ASHRAE et al. 2011a). The AEDG-K12 provides recommendations for achieving 50% whole-building energy savings in K-12 schools over levels achieved by followingANSI/ASHRAE/IESNA Standard 90.1-2004, Energy Standard for Buildings Except Low-Rise Residential Buildings (Standard 90.1-2004) (ASHRAE 2004b). The AEDG-K12 was developed in collaboration with the American Society of Heating, Refrigerating and Air-Conditioning Engineers (ASHRAE), the American Institute of Architects (AIA), the Illuminating Engineering Society of North America (IES), the U.S.Green Building Council (USGBC), and the U.S. Department of Energy (DOE).

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

LA100 Equity Strategies. Chapter 7: Housing Weatherization and Resilience

The LA100 Equity Strategies project integrates community guidance with robust research, modeling, and analysis to identify strategy options that can increase equitable outcomes in Los Angeles' clean energy transition. This chapter focuses on housing weatherization and access to cooling as means to achieve more equitable resilience to heat waves during unplanned power outages. Specifically, NREL used weather, housing, and socioeconomic data to characterize LA's residential building stock. We?developed a residential building stock model to simulate the energy use of 50,000 dwellings representing the diversity of housing types, appliances, climate zones, and household incomes across Los Angeles. We then simulated and evaluated the impacts of 10 building envelope and cooling upgrades on indoor temperature - a main cause of heat-induced health risks-over a 4-day power outage during a heat wave. We examined occupant exposure to extreme heat and how heat exposure changes with each upgrade across income, tenure (renter/owner status), building type, and disadvantaged community (DAC) status. We also examined upgrade costs and utility bills. Based on the results of our analysis and community guidance, we identified building envelope upgrades and cooling strategies that could save lives and maintain safe home temperatures for LA's low-income households in the event of a planned or unplanned power outage during a summer heat wave. Research was guided by input from the community engagement process, and associated equity strategies are presented in alignment with that guidance.

building envelope↗

ResStock™ v3.2.0 [SWR-19-15 and SWR-20-07]

The ResStock™ analysis tool was built on NREL's OpenStudio® platform, and is a project geared at modeling existing residential building stocks at national, regional, or local scales with a high-degree of granularity (e.g., one physics-based simulation model for every 200 dwelling units), using the EnergyPlus® simulation engine. Information about ComStock™, a sister tool for modeling the commercial building stock, can be found here: https://www.nrel.gov/buildings/comstock.html This repository contains: Housing characteristics of the U.S. residential building stock, in the form of conditional probability distributions stored as tab-separated value (.tsv) files. Comments at the bottom of each file document data sources and assumptions for each. A library of housing characteristic "options" that translate high-level characteristic parameters into arguments for OpenStudio measures, and which are referenced by the housing characteristic .tsv files and building energy upgrades defined in project definition files Project definition files: v2.3.0 and later: buildstockbatch YML files openable in any text editor v2.2.5 and prior: Project folder openable in PAT Unit-level OpenStudio Measures for automatically constructing OpenStudio Models of each representative dwelling unit model: v3.0.0 and later: OpenStudio-HPXML Measures v2.5.0 and prior: OpenStudio Measures Higher-level OpenStudio Measures for controlling simulation inputs and outputs This repository does not contain software for running ResStock simulations, which can be found as follows: Versions 2.3.0 and later only support the use of buildstockbatch for deploying simulations on high-performance or cloud computing. Version 2.3.0 also removed separate projects for single-family detached and multifamily buildings, in lieu of a combined project_national representing the U.S. residential building stock. See the changelog for more details. Versions 2.2.5 and prior support the use of the publicly available OpenStudio-PAT software as an interface for deploying simulations on cloud computing. Read the documentation for v2.2.5.

Horowitz, Scott↗

Is Every kWh the Same? How Do Energy Efficiency Measures Stack Up Across Regions?

The U.S. residential building sector is responsible for thirty-eight percent of electricity use, as well as for 49%, 8%, 19% and 2% of U.S. SO2, NOx, CO2 and PM2.5 emissions, respectively. The residential building sector is also a key target of customer funded energy efficiency programs, which have typically been designed to reduce energy consumption (kWh). Today, energy efficiency is also being used to meet air emissions goals. However, not every kWh saved has the same mitigation potential. The goal of this work is to evaluate energy efficiency potential in the U.S. residential building sector and determine how energy conservation measures (ECMs) that reduce electricity consumption correlate to air emissions reductions. To assess energy efficiency potential, this analysis uses Scout, a software program developed by the U.S. Department of Energy that estimates the energy and CO2 impact potential of various ECMs on the U.S. residential and commercial building sectors. Here, Scout is first used to assess the total long term national energy (electricity, gas, and oil), CO2, and cost savings of deploying residential ECM portfolios. Then, electricity savings results from Scout in 2021 are used to assess the regional differences in emissions reductions with the Avoided Emissions and geneRation Tool (AVERT) model from different end uses. Better understanding the relationship between ECMs and cost-effective emission reductions will enable states, municipalities and other interested parties to meet multiple policy objectives through energy efficiency.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Analysis of Installed Measures and Energy Savings for Single-Family Residential Better Buildings Projects

This report presents an analysis of data for residential single-family projects reported by 37 organizations that were awarded federal financial assistance (cooperative agreements or grants) by the U.S. Department of Energy’s Better Buildings Neighborhood Program.1 The report characterizes the energy-efficiency measures installed for single-family residential projects and analyzes energy savings and savings prediction accuracy for measures installed in a subset of those projects.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

2015 IECC Determination of Energy Savings: Preliminary Technical Analysis

This report documents the technical analysis used to evaluate whether residential buildings constructed to meet the requirements of the 2015 IECC would result in energy-efficiency improvements over residential buildings constructed to meet the requirements of the previous edition, the 2012 IECC. PNNL considered all code change proposals approved for inclusion in the 2015 IECC during the ICC code development cycle, and evaluated their combined impact on a suite of prototypical residential building energy models across all U.S. climate zones.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Technology Solutions Case Study: Selecting Ventilation Systems for Existing Homes

In multifamily buildings, particularly in the Northeast, exhaust ventilation strategies are the norm as a means of meeting both local exhaust and whole-unit mechanical ventilation rates. The issue of where the "fresh" air is coming from is gaining significance as air-tightness standards for enclosures become more stringent, and the normal leakage paths through the building envelope disappear. Researchers from the Consortium for Advanced Residential Buildings (CARB) found that the majority of high performance, new construction, multifamily housing in the Northeast use one of four general strategies for ventilation: continuous exhaust only with no designated supply or make-up air source, continuous exhaust with ducted make-up air to apartments, continuous exhaust with supply through a make-up air device integral to the unit HVAC, and continuous exhaust with supply through a passive inlet device, such as a trickle vent. Insufficient information is available to designers on how these various systems are best applied. In this project, the CARB team evaluated the four different strategies for providing make-up air to multifamily residential buildings and developed guidelines to help contractors and building owners choose the best ventilation systems.

apartments↗

New Whole-House Solutions Case Study: Challenges of Achieving 2012 IECC Air Sealing Requirements in Multifamily Dwellings, Upstate New York

While previous versions of the International Energy Conservation Code (IECC) have included provisions to improve the air tightness of dwellings, for the first time, the 2012 IECC mandates compliance verification through blower door testing. Simply completing the Air Barrier and Insulation Installation checklist through visual inspection is no longer sufficient; the 2012 IECC mandates a significantly stricter air sealing requirement. In Climate Zones 3 through 8, air leakage may not exceed 3 ACH50, which is a significant reduction from the 2009 IECC requirement of 7 ACH50. This requirement is for all residential buildings, which includes low-rise multifamily dwellings. While this air leakage rate requirement is an important component to achieving an efficient building thermal envelope, currently, the code language doesn't explicitly address differences between single family and multifamily applications. In addition, the 2012 IECC does not provide an option to sample dwellings for larger multifamily buildings, so compliance would have to be verified on every unit. With compliance with the 2012 IECC air leakage requirements on the horizon, several of Building America team Consortium for Advanced Residential Building's (CARB) multifamily builder partners are evaluating how best to comply with this requirement. Builders are not sure whether it is more practical or beneficial to simply pay for guarded testing or to revise their air sealing strategies to improve compartmentalization to comply with code requirements based on unguarded blower door testing. This report summarizes CARB's research that was conducted to assess the feasibility of meeting the 2012 IECC air leakage requirements in three multifamily buildings.

air leakage↗

The Advancement of Cool Roof Standards in China from 2010 to 2015

Since the initiation of the U.S.-China Clean Energy Research Center-Building Energy Efficiency (CERC-BEE) cool roof research collaboration between the Lawrence Berkeley National Laboratory Heat Island Group and Chinese institutions in 2010, new cool surface credits (insulation trade- offs) have been adopted in Chinese building energy efficiency standards, industry standards, and green building standards. JGJ 75-2012: Design Standard for Energy Efficiency of Residential Buildings in Hot Summer and Warm Winter Zone became the first national level standard to provide cool surface credits. GB/T 50378-2014: Assessment Standard for Green Building is the first national level green building standard that offers points for heat island mitigation. JGJ/T 359-2015: Technical Specification for Application of Architectural Reflective Thermal Insulation Coating is the first industry standard that offers cool coating credits for both public and residential buildings in all hot-summer climates (Hot Summer/Cold Winter, Hot Summer/Warm Winter). As of December 2015, eight provinces or municipalities in hot-summer regions have credited cool surfaces credits in their residential and/or public building design standards; five other provinces or municipalities in hot-summer regions recommend, but do not credit, the use of cool surfaces in their building design standards. Cool surfaces could be further advanced in China by including cool roof credits for residential and public building energy efficiency standards in all hot-summer regions; developing a standardized process for natural exposure and aged-property rating of cool roofing products; and adapting the U.S.-developed laboratory aging process for roofing materials to replicate solar reflectance changes induced by natural exposure in China.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Procedures for Calculating Residential Dehumidification Loads

Residential building codes and voluntary labeling programs are continually increasing the energy efficiency requirements of residential buildings. Improving a building's thermal enclosure and installing energy-efficient appliances and lighting can result in significant reductions in sensible cooling loads leading to smaller air conditioners and shorter cooling seasons. However due to fresh air ventilation requirements and internal gains, latent cooling loads are not reduced by the same proportion. Thus, it's becoming more challenging for conventional cooling equipment to control indoor humidity at part-load cooling conditions and using conventional cooling equipment in a non-conventional building poses the potential risk of high indoor humidity. The objective of this project was to investigate the impact the chosen design condition has on the calculated part-load cooling moisture load, and compare calculated moisture loads and the required dehumidification capacity to whole-building simulations. Procedures for sizing whole-house supplemental dehumidification equipment have yet to be formalized; however minor modifications to current Air-Conditioner Contractors of America (ACCA) Manual J load calculation procedures are appropriate for calculating residential part-load cooling moisture loads. Though ASHRAE 1% DP design conditions are commonly used to determine the dehumidification requirements for commercial buildings, an appropriate DP design condition for residential buildings has not been investigated. Two methods for sizing supplemental dehumidification equipment were developed and tested. The first method closely followed Manual J cooling load calculations; whereas the second method made more conservative assumptions impacting both sensible and latent loads.

47 OTHER INSTRUMENTATION↗

Strategy Guideline: Proper Water Heater Selection

This Strategy Guideline on proper water heater selection was developed by the Building America team Alliance for Residential Building Innovation to provide step-by-step procedures for evaluating preferred cost-effective options for energy efficient water heater alternatives based on local utility rates, climate, and anticipated loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Evaluation of Two CEDA Weatherization Pilot Implementations of an Exterior Insulation and Over-Clad Retrofit Strategy for Residential Masonry Buildings in Chicago

This project examines the implementation of an exterior insulation and over-clad strategy for brick masonry buildings in Chicago. The strategy was implemented at a free-standing two story two-family dwelling and a larger free-standing multifamily building. The test homes selected for this research represent predominant housing types for the Chicago area. High heating energy use typical in these buildings threaten housing affordability. Uninsulated mass masonry wall assemblies also have a strongly detrimental impact on comfort. Significant changes to the performance of masonry wall assemblies is generally beyond the reach of typical weatherization (Wx) program resources. The Community and Economic Development Association of Cook County, Inc. (CEDA) has secured a Sustainable Energy Resources for Consumers (SERC) innovation grant sponsored by the United States Department of Energy (DOE). This grant provides CEDA the opportunity to pursue a pilot implementation of innovative approaches to retrofit in masonry wall enclosures. The exterior insulation and over-clad strategy implemented through this project was designed to allow implementation by contractors active in CEDA weatherization programs and using materials and methods familiar to these contractors. The retrofit measures are evaluated in terms of feasibility, cost and performance. Through observations of the strategies implemented, the research described in this report identifies measures critical to performance as well as conditions for wider adoption. The research also identifies common factors that must be considered in determining whether the exterior insulation and over-clad strategy is appropriate for the building.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗