Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Relative Biological Effectiveness”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Evaluating Intensity Modulated Proton Therapy Relative to Passive Scattering Proton Therapy for Increased Vertebral Column Sparing in Craniospinal Irradiation in Growing Pediatric Patients

Purpose: At present, proton craniospinal irradiation (CSI) for growing children is delivered to the whole vertebral body (WVB) to avoid asymmetric growth. We aimed to demonstrate the feasibility and potential clinical benefit of delivering vertebral body sparing (VBS) versus WVB CSI with passively scattered (PS) and intensity modulated proton therapy (IMPT) in growing children treated for medulloblastoma. Methods and Materials: Five plans were generated for medulloblastoma patients, who had been previously treated with CSI PS proton radiation therapy: (1) single posteroanterior (PA) PS field covering the WVB (PS-PA-WVB); (2) single PA PS field that included only the thecal sac in the target volume (PS-PA-VBS); (3) single PA IMPT field covering the WVB (IMPT-PA-WVB); (4) single PA IMPT field, target volume including thecal sac only (IMPT-PA-VBS); and (5) 2 posterior-oblique (−35°, +35°) IMPT fields, with the target volume including the thecal sac only (IMPT2F-VBS). For all cases, 23.4 Gy (relative biologic effectiveness [RBE]) was prescribed to 95% of the spinal canal. The dose, linear energy transfer, and variable-RBE-weighted dose distributions were calculated for all plans using the tool for particle simulation, version 2, Monte Carlo system. Results: IMPT VBS techniques efficiently spared the anterior vertebral bodies (AVBs), even when accounting for potential higher variable RBE predicted by linear energy transfer distributions. Assuming an RBE of 1.1, the V10 Gy(RBE) decreased from 100% for the WVB techniques to 59.5% to 76.8% for the cervical, 29.9% to 34.6% for the thoracic, and 20.6% to 25.1% for the lumbar AVBs, and the V20 Gy(RBE) decreased from 99.0% to 17.8% to 20.0% for the cervical, 7.2% to 7.6% for the thoracic, and 4.0% to 4.6% for the lumbar AVBs when IMPT VBS techniques were applied. The corresponding percentages for the PS VBS technique were higher. Conclusions: Advanced proton techniques can sufficiently reduce the dose to the vertebral body and allow for vertebral column growth for children with central nervous system tumors requiring CSI. This was true even when considering variable RBE values. A clinical trial is planned for VBS to the thoracic and lumbosacral spine in growing children.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Empowering Intensity Modulated Proton Therapy Through Physics and Technology: An Overview

Considering the clinical potential of protons attributable to their physical characteristics, interest in proton therapy has increased greatly in this century, as has the number of proton therapy installations. Until recently, passively scattered proton therapy was used almost entirely. Notably, the overall clinical results to date have not shown a convincing benefit of protons over photons. A rapid transition is now occurring with the implementation of the most advanced form of proton therapy, intensity modulated proton therapy (IMPT). IMPT is superior to passively scattered proton therapy and intensity modulated radiation therapy (IMRT) dosimetrically. However, numerous limitations exist in the present IMPT methods. In particular, compared with IMRT, IMPT is highly vulnerable to various uncertainties. In this overview we identify three major areas of current limitations of IMPT: treatment planning, treatment delivery, and motion management, and discuss current and future efforts for improvement. For treatment planning, we need to reduce uncertainties in proton range and in computed dose distributions, improve robust planning and optimization, enhance adaptive treatment planning and delivery, and consider how to exploit the variability in the relative biological effectiveness of protons for clinical benefit. The quality of proton therapy also depends on the characteristics of the IMPT delivery systems and image guidance. Efforts are needed to optimize the beamlet spot size for both improved dose conformality and faster delivery. For the latter, faster energy switching time and increased dose rate are also needed. Real-time in-room volumetric imaging for guiding IMPT is in its early stages with cone beam computed tomography (CT) and CT-on-rails, and continued improvements are anticipated. In addition, imaging of the proton beams themselves, using, for instance, prompt γ emissions, is being developed to determine the proton range and to reduce range uncertainty. With the realization of the advances described above, we posit that IMPT, thus empowered, will lead to substantially improved clinical results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Asymptomatic Late-phase Radiographic Changes Among Chest-Wall Patients Are Associated With a Proton RBE Exceeding 1.1

Clinical practice assumes a fixed proton relative biological effectiveness (RBE) of 1.1, but in vitro experiments demonstrate higher RBEs at the distal edge of the proton spread-out Bragg peak, that is, in a region that falls within the lung for chest-wall patients. We performed retrospective qualitative and quantitative analyses of lung-density changes—indicative of asymptomatic fibrosis—for chest-wall patients treated with protons or photons. Our null hypothesis was that, assuming a fixed RBE of 1.1, these changes would be the same for the 2 cohorts, supporting current RBE practice. Our alternative hypothesis was that radiographic abnormalities would be greater for the proton cohort, suggesting an RBE > 1.1.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Single shot cell irradiations with laser-driven protons

Ion beams are relevant for radiobiological studies in basic research and for application in tumor therapy. Here we present a method to generate nanosecond proton bunches with single shot doses of up to 7 Gray by a tabletop high-power laser. Although in their infancy, laser-ion accelerators allow studying fast radiobiological processes at small-scale laboratories as exemplarily demonstrated by measurements of the relative biological effectiveness of protons in human tumor cells.

43 PARTICLE ACCELERATORS↗

An Empirical Method for deriving RBE values associated with Electrons, Photons and Radionuclides

There is substantial evidence to justify using relative biological effectiveness (RBE) values greater than one for low-energy electrons and photons. But, in the field of radiation protection, radiation associated with low linear energy transfer (LET) has been assigned a radiation weighting factor w R of one. This value may be suitable for radiation protection but, for risk considerations, it is important to evaluate the potential elevated biological effectiveness of radiation to improve the quality of risk estimates. RBE values between 2 and 3 for tritium are implied by several experimental measurements. Additionally, elevated RBE values have been found for other similar low-energy radiation sources. In this work, RBE values are derived for electrons based upon the fractional deposition of absorbed dose of energies less than a few keV. Using this empirical method, RBE values were also derived for monoenergetic photons and 1070 radionuclides from ICRP Publication 107 for which photons and electrons are the primary emissions.

59 BASIC BIOLOGICAL SCIENCES↗

Impact of variable RBE on proton fractionation

Purpose: To explore the impact of variable proton relative biological effectiveness (RBE) on dose fractionation for clinically relevant situations. A generic RBE = 1.1 is generally used for isoeffect calculations, while experimental studies showed that proton RBE varies with tissue type, dose, and linear energy transfer (LET). Methods: An analytical expression for the LET and {alpha}/{beta} dependence of the linear-quadratic (LQ) model has been used for proton simulations in parallel with the assumption of a generic RBE = 1.1. Calculations have been performed for ranges of LET values and fractionation sensitivities to describe clinically relevant cases, such as the treatment of head and neck and prostate tumors. Isoeffect calculations were compared with predictions from a generic RBE value and reported clinical results. Results: The generic RBE = 1.1 appears to be a reasonable estimate for the proton RBE of rapidly growing tissues irradiated with low LET radiation. However, the use of a variable RBE predicts larger differences for tissues with low {alpha}/{beta} (both tumor and normal) and at low doses per fraction. In some situations these differences may appear in contrast to the findings from photon studies highlighting the importance of accurate accounting for the radiobiological effectiveness of protons. Furthermore, the use of variable RBE leads to closer predictions to clinical results. Conclusions: The LET dependence of the RBE has a strong impact on the predicted effectiveness of fractionated proton radiotherapy. The magnitude of the effect is modulated by the fractionation sensitivity and the fractional dose indicating the need for accurate analyses both in the target and around it. Care should therefore be employed for changing clinical fractionation patterns or when analyzing results from clinical studies for this type of radiation.

60 APPLIED LIFE SCIENCES↗

Influence of nuclear interactions in polyethylene range compensators for carbon-ion radiotherapy

Purpose: A recent study revealed that polyethylene (PE) would cause extra carbon-ion attenuation per range shift by 0.45%/cm due to compositional differences in nuclear interactions. The present study aims to assess the influence of PE range compensators on tumor dose in carbon-ion radiotherapy. Methods: Carbon-ion radiation was modeled to be composed of primary carbon ions and secondary particles, for each of which the dose and the relative biological effectiveness (RBE) were estimated at a tumor depth in the middle of spread-out Bragg peak. Assuming exponential behavior for attenuation and yield of these components with depth, the PE effect on dose was calculated for clinical carbon-ion beams and was partly tested by experiment. The two-component model was integrated into a treatment-planning system and the PE effect was estimated in two clinical cases. Results: The attenuation per range shift by PE was 0.1%–0.3%/cm in dose and 0.2%–0.4%/cm in RBE-weighted dose, depending on energy and range-modulation width. This translates into reduction of RBE-weighted dose by up to 3% in extreme cases. In the treatment-planning study, however, the effect on RBE-weighted dose to tumor was typically within 1% reduction. Conclusions: The extra attenuation of primary carbon ions in PE was partly compensated by increased secondary particles for tumor dose. In practical situations, the PE range compensators would normally cause only marginal errors as compared to intrinsic uncertainties in treatment planning, patient setup, beam delivery, and clinical response.

60 APPLIED LIFE SCIENCES↗

Poster — Thur Eve — 45: Comparison of different Monte Carlo methods of scoring linear energy transfer in modulated proton therapy beams

In this work, we demonstrate inconsistencies in commonly used Monte Carlo methods of scoring linear energy transfer (LET) in proton therapy beams. In particle therapy beams, the LET is an important parameter because the relative biological effectiveness (RBE) depends on it. LET is often determined using Monte Carlo techniques. We used a realistic Monte Carlo model of a proton therapy nozzle to score proton LET in spread-out Bragg peak (SOBP) depth-dose distributions. We used three different scoring and calculation techniques to determine average LET at varying depths within a 140 MeV beam with a 4 cm SOBP and a 250 MeV beam with a 10 cm SOBP. These techniques included fluence-weighted (Φ-LET) and dose-weighted average (D-LET) LET calculations from: 1) scored energy spectra converted to LET spectra through a lookup table, 2) directly scored LET spectra and 3) accumulated LET scored ‘on-the-fly’ during simulations. All protons (primary and secondary) were included in the scoring. Φ-LET was found to be less sensitive to changes in scoring technique than D-LET. In addition, the spectral scoring methods were sensitive to low-energy (high-LET) cutoff values in the averaging. Using cutoff parameters chosen carefully for consistency between techniques, we found variations in Φ-LET values of up to 1.6% and variations in D-LET values of up to 11.2% for the same irradiation conditions, depending on the method used to score LET. Variations were largest near the end of the SOBP, where the LET and energy spectra are broader.

07 ISOTOPE AND RADIATION SOURCES↗

Assessment of potential advantages of relevant ions for particle therapy: A model based study

Purpose: Different ion types offer different physical and biological advantages for therapeutic applications. The purpose of this work is to assess the advantages of the most commonly used ions in particle therapy, i.e., carbon ({sup 12}C), helium ({sup 4}He), and protons ({sup 1}H) for different treatment scenarios. Methods: A treatment planning analysis based on idealized target geometries was performed using the treatment planning software TRiP98. For the prediction of the relative biological effectiveness (RBE) that is required for biological optimization in treatment planning the local effect model (LEM IV) was used. To compare the three ion types, the peak-to-entrance ratio (PER) was determined for the physical dose (PER{sub PHY} {sub S}), the RBE (PER{sub RBE}), and the RBE-weighted dose (PER{sub BIO}) resulting for different dose-levels, field configurations, and tissue types. Further, the dose contribution to artificial organs at risk (OAR) was assessed and a comparison of the dose distribution for the different ion types was performed for a patient with chordoma of the skull base. Results: The study showed that the advantages of the ions depend on the physical and biological properties and the interplay of both. In the case of protons, the consideration of a variable RBE instead of the clinically applied generic RBE of 1.1 indicates an advantage in terms of an increased PER{sub RBE} for the analyzed configurations. Due to the fact that protons show a somewhat better PER{sub PHY} {sub S} compared to helium and carbon ions whereas helium shows a higher PER{sub RBE} compared to protons, both protons and helium ions show a similar RBE-weighted dose distribution. Carbon ions show the largest variation of the PER{sub RBE} with tissue type and a benefit for radioresistant tumor types due to their higher LET. Furthermore, in the case of a two-field irradiation, an additional gain in terms of PER{sub BIO} is observed when using an orthogonal field configuration for carbon ions as compared to opposing fields. In contrast, for protons, the PER{sub BIO} is almost independent on the field configuration. Concerning the artificial lateral OAR, the volume receiving 20% of the prescribed RBE-weighted dose (V20) was reduced by over 35% using helium ions and by over 40% using carbon ions compared to protons. The analysis of the patient plan showed that protons, helium, and carbon ions are similar in terms of target coverage whereas the dose to the surrounding tissue is increasing from carbon ions toward protons. The mean dose to the brain stem can be reduced by more than 55% when using helium ions and by further 25% when using carbon ions instead of protons. Conclusions: The comparison of the PER{sub RBE} and PER{sub PHY} {sub S} of the three ion types suggests a strong dependence of the advantages of the three ions on the dose-level, tissue type, and field configuration. In terms of conformity, i.e., dose to the normal tissue, a clear gain is expected using carbon or helium ions compared to protons.

60 APPLIED LIFE SCIENCES↗

SU-E-T-581: On the Value of LET as a Radiation Quality Descriptor for RBE

Purpose: To investigate the relationship between linear energy transfer (LET) and relative biological effectiveness (RBE) for protons and light ions, and the corresponding role of LET as a descriptor of radiation quality of hadron therapy. Methods: Monte Carlo (MC) proton and light ion (He, Li, C) tracks with LET < 30 eV nm{sup -1} were generated in an event-by-event mode. They were overlaid on a cell nucleus model containing 6×10{sup 9} nucleotide base pairs using an isotropic irradiation procedure that provides electronic equilibrium. Strand breaks (sbs) were scored in the DNA sugar-phosphate groups and further sub-classified into single or double sbs (ssbs or dsbs). Distributions of ssbs and dsbs for 2 Gy fractions were calculated to estimate RBE for the induction of initial dsbs with reference to {sup 60}Co. Additionally, sbs were classified based on their complexity (i.e. the number of sbs in each cluster). Results: An increase in LET for light ions of the same atomic number or a decrease in atomic number for ions of the same LET resulted in a lower kinetic energy of emitted secondary electrons. The clustering of DNA damage was more pronounced as reflected by the increase in proton RBE from ∼ 1.75 to 4 for LET values of 7 to 28 eV nm{sup -1}. A significant RBE decrease between protons, He, Li and C ions of the same LET was also noticed as function of the atomic number. Significant differences in ssbs and dsbs complexities were also seen for particles with the same LET, potentially supporting a clustering-based radiation quality descriptor. Conclusion: The LET-RBE relationships were simulated for proton and light ions and exhibited expected trends, including different RBEs for particles with the same LET but different atomic numbers. A complexity based radiation quality descriptor may allow better differentiation of RBE between radiation fields of similar LET. We would like to acknowledge support from the Fonds de recherche du Quebec Sante (FRQS), from the CREATE Medical Physics Research Training Network grant (number 432290) of NSERC, support from NSERC under grants RGPIN 397711-11 and RGPIN-2014-06475 and support from CIHR under grants MOP-114910, MOP-136774 and MOP-102550.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-764: Track Repeating Algorithm for Proton Therapy Applied to Intensity Modulated Proton Therapy for Head-And-Neck Patients

Purpose: To determine the suitability of fast Monte Carlo techniques for dose calculation in particle therapy based on track-repeating algorithm for Intensity Modulated Proton Therapy, IMPT. The application of this technique will make possible detailed retrospective studies of large cohort of patients, which may lead to a better determination of Relative Biological Effects from the analysis of patient data. Methods: A cohort of six head-and-neck patients treated at the University of Texas MD Anderson Cancer Center with IMPT were utilized. The dose distributions were calculated with the standard Treatment Plan System, TPS, MCNPX, GEANT4 and FDC, a fast track-repeating algorithm for proton therapy for the verification and the patient plans. FDC is based on a GEANT4 database of trajectories of protons in a water. The obtained dose distributions were compared to each other utilizing the g-index criteria for 3mm-3% and 2mm-2%, for the maximum spatial and dose differences. The γ-index was calculated for voxels with a dose at least 10% of the maximum delivered dose. Dose Volume Histograms are also calculated for the various dose distributions. Results: Good agreement between GEANT4 and FDC is found with less than 1% of the voxels with a γ-index larger than 1 for 2 mm-2%. The agreement between MCNPX with FDC is within the requirements of clinical standards, even though it is slightly worse than the comparison with GEANT4.The comparison with TPS yielded larger differences, what is also to be expected because pencil beam algorithm do not always performed well in highly inhomogeneous areas like head-and-neck. Conclusion: The good agreement between a track-repeating algorithm and a full Monte Carlo for a large cohort of patients and a challenging, site like head-and-neck, opens the path to systematic and detailed studies of large cohorts, which may yield better understanding of biological effects.

60 APPLIED LIFE SCIENCES↗

SU-E-T-782: Using Light Output From Doped Plastic Scintillators to Resolve the Linear Energy Transfer Spectrum of Clinical Electron Beams

Purpose: This research seeks to develop a portable, clinically-suitable linear energy transfer (LET) detector. In radiotherapy, absorbed dose is commonly used to measure the amount of delivered radiation, though, it is not a good indicator of actual biological damage. LET is the energy absorbed per unit length by a medium along charged particle’s pathway; studies have shown that LET correlates well with relative biological effectiveness (RBE). Methods: According to Birks’ law, light output of plastic scintillators is stopping-power dependent. This dependency can be varied through doping by various high-Z elements. By measuring light output signals of differently doped plastic scintillators (represented by column vector S, where each row corresponds to different scintillator material), the fluence of charged particles of a given LET (represented by column vector Φ, where each row corresponds to different LET bins) can be unfolded by S=R*Φ where R is system response matrix (each row represents a different scintillator, each column corresponds to different electron LET). Monte Carlo (MC) GEANT4.10.1 was used to evaluate ideal detector response of BC408 scintillating material doped with various concentrations of several high Z dopants. Measurements were performed to validate MC. Results: Signal for 1%-lead doped BC408 and the non-doped scintillator was measured experimentally by guiding light emitted by the scintillator (via in-house made taper, fiber system) to a PMT and then an electrometer. Simulations of 1%Pb-doped scintillator to non-doped scintillator revealed 9.3% reduction in light output for 6 MeV electrons which compared well (within uncertainty) with measurements showing 10% reduction (6MeV electrons). Conclusion: Measurements were used to validate MC simulation of light output from doped scintillators. The doping of scintillators is a viable technique to induce LET dependence. Our goal is to use this effect to resolve the LET spectrum of an incident beam.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-08: LET-Based Inverse Planning for IMPT

Purpose: Cell survival experiments suggest that the relative biological effectiveness (RBE) of proton beams depends on linear energy transfer (LET), leading to higher RBE near the end of range. With intensity-modulated proton therapy (IMPT), multiple treatment plans that differ in the dose contribution per field may yield a similar physical dose distribution, but the RBE-weighted dose distribution may be disparate. RBE models currently do not have the required predictive power to be included in an optimization model due to the variations in experimental data. We propose an LET-based planning method that guides IMPT optimization models towards plans with reduced RBE-weighted dose in surrounding organs at risk (OARs) compared to inverse planning based on physical dose alone. Methods: Optimization models for physical dose are extended with a term for dose times LET (doseLET). Monte Carlo code is used to generate the physical dose and doseLET distribution of each individual pencil beam. The method is demonstrated for an atypical meningioma patient where the target volume abuts the brainstem and partially overlaps with the optic nerve. Results: A reference plan optimized based on physical dose alone yields high doseLET values in parts of the brainstem and optic nerve. Minimizing doseLET in these critical structures as an additional planning goal reduces the risk of high RBE-weighted dose. The resulting treatment plan avoids the distal fall-off of the Bragg peaks for shaping the dose distribution in front of critical stuctures. The maximum dose in the OARs evaluated with RBE models from literature is reduced by 8–14\% with our method compared to conventional planning. Conclusion: LET-based inverse planning for IMPT offers the ability to reduce the RBE-weighted dose in OARs without sacrificing target dose. This project was in part supported by NCI - U19 CA 21239.

60 APPLIED LIFE SCIENCES↗

TU-EF-304-12: Proton Radiation Therapy for Left-Sided Breast Cancer: LET and RBE Considerations for Cardiac Toxicity

Purpose: Increased risk of coronary artery disease has been documented for patients treated with radiation for left-sided breast cancer. Proton therapy (PRT) has been shown to significantly decrease cardiac irradiation, however variations in relative biological effectiveness (RBE) have been ignored so far. In this study we evaluate the impact of accounting for RBE variations on sensitive structures located within high linear energy transfer (LET) areas (distal end) of the proton treatment fields, for this treatment site. Methods: Three patients treated in our institution with PRT for left-sided breast cancer were selected. All patients underwent reconstructive surgery after mastectomy and treated to a total dose of 50.4Gy with beam(s) vertical to the chest wall. Dose and LET distributions were calculated using Monte Carlo (MC-TOPAS - TOol for PArticle Simulation). The LET-based, variable-RBE-weighted dose was compared to the analytical calculation algorithm (ACA) and MC dose distributions for a constant RBE of 1.1, based on volume histograms and mean values for the target, heart and left anterior descending coronary artery (LAD). Results: Assuming a constant RBE and compared to the ACA dose, MC predicted lower mean target and heart doses by 0.5% to 2.7% of the prescription dose. For variable RBE, plan evaluation showed increased mean target dose by up to 5%. Mean variable-RBE-weighted doses for the LAD ranged from 2.7 to 5.9Gy(RBE) among patients increased by 41%–64.2% compared to constant RBE ACA calculation (absolute dose: 1.7–3.9Gy(RBE)). Smaller increase in mean heart doses was noticed. Conclusion: ACA overestimates the target mean dose by up to 2.7%. However, disregarding variations in RBE may lead to significant underestimation of the dose to sensitive structures at the distal end of the proton treatment field and could thus impact outcome modeling for cardiac toxicities after proton therapy. These results are subject to RBE model and parameter uncertainties.

60 APPLIED LIFE SCIENCES↗

Implementation of spot scanning dose optimization and dose calculation for helium ions in Hyperion

Purpose: Helium ions ({sup 4}He) may supplement current particle beam therapy strategies as they possess advantages in physical dose distribution over protons. To assess potential clinical advantages, a dose calculation module accounting for relative biological effectiveness (RBE) was developed and integrated into the treatment planning system Hyperion. Methods: Current knowledge on RBE of {sup 4}He together with linear energy transfer considerations motivated an empirical depth-dependent “zonal” RBE model. In the plateau region, a RBE of 1.0 was assumed, followed by an increasing RBE up to 2.8 at the Bragg-peak region, which was then kept constant over the fragmentation tail. To account for a variable proton RBE, the same model concept was also applied to protons with a maximum RBE of 1.6. Both RBE models were added to a previously developed pencil beam algorithm for physical dose calculation and included into the treatment planning system Hyperion. The implementation was validated against Monte Carlo simulations within a water phantom using γ-index evaluation. The potential benefits of {sup 4}He based treatment plans were explored in a preliminary treatment planning comparison (against protons) for four treatment sites, i.e., a prostate, a base-of-skull, a pediatric, and a head-and-neck tumor case. Separate treatment plans taking into account physical dose calculation only or using biological modeling were created for protons and {sup 4}He. Results: Comparison of Monte Carlo and Hyperion calculated doses resulted in a γ{sub mean} of 0.3, with 3.4% of the values above 1 and γ{sub 1%} of 1.5 and better. Treatment plan evaluation showed comparable planning target volume coverage for both particles, with slightly increased coverage for {sup 4}He. Organ at risk (OAR) doses were generally reduced using {sup 4}He, some by more than to 30%. Improvements of {sup 4}He over protons were more pronounced for treatment plans taking biological effects into account. All OAR doses were within tolerances specified in the QUANTEC report. Conclusions: The biological {sup 4}He model proposed above is a first approach matching biological data published so far. The advantage of {sup 4}He seems to lie in the reduction of dose to surrounding tissue and to OARs. Nevertheless, additional biological experiments and treatment planning studies with larger patient numbers and more tumor indications are necessary to study the possible benefits of helium ion beam therapy in detail.

60 APPLIED LIFE SCIENCES↗

EUD-based biological optimization for carbon ion therapy

Purpose: Treatment planning for carbon ion therapy requires an accurate modeling of the biological response of each tissue to estimate the clinical outcome of a treatment. The relative biological effectiveness (RBE) accounts for this biological response on a cellular level but does not refer to the actual impact on the organ as a whole. For photon therapy, the concept of equivalent uniform dose (EUD) represents a simple model to take the organ response into account, yet so far no formulation of EUD has been reported that is suitable to carbon ion therapy. The authors introduce the concept of an equivalent uniform effect (EUE) that is directly applicable to both ion and photon therapies and exemplarily implemented it as a basis for biological treatment plan optimization for carbon ion therapy. Methods: In addition to a classical EUD concept, which calculates a generalized mean over the RBE-weighted dose distribution, the authors propose the EUE to simplify the optimization process of carbon ion therapy plans. The EUE is defined as the biologically equivalent uniform effect that yields the same probability of injury as the inhomogeneous effect distribution in an organ. Its mathematical formulation is based on the generalized mean effect using an effect-volume parameter to account for different organ architectures and is thus independent of a reference radiation. For both EUD concepts, quadratic and logistic objective functions are implemented into a research treatment planning system. A flexible implementation allows choosing for each structure between biological effect constraints per voxel and EUD constraints per structure. Exemplary treatment plans are calculated for a head-and-neck patient for multiple combinations of objective functions and optimization parameters. Results: Treatment plans optimized using an EUE-based objective function were comparable to those optimized with an RBE-weighted EUD-based approach. In agreement with previous results from photon therapy, the optimization by biological objective functions resulted in slightly superior treatment plans in terms of final EUD for the organs at risk (OARs) compared to voxel-based optimization approaches. This observation was made independent of the underlying objective function metric. An absolute gain in OAR sparing was observed for quadratic objective functions, whereas intersecting DVHs were found for logistic approaches. Even for considerable under- or overestimations of the used effect- or dose–volume parameters during the optimization, treatment plans were obtained that were of similar quality as the results of a voxel-based optimization. Conclusions: EUD-based optimization with either of the presented concepts can successfully be applied to treatment plan optimization. This makes EUE-based optimization for carbon ion therapy a useful tool to optimize more specifically in the sense of biological outcome while voxel-to-voxel variations of the biological effectiveness are still properly accounted for. This may be advantageous in terms of computational cost during treatment plan optimization but also enables a straight forward comparison of different fractionation schemes or treatment modalities.

60 APPLIED LIFE SCIENCES↗

SU-F-T-124: Radiation Biological Equivalent Presentations OfLEM-1 and MKM Approaches in the Carbon-Ion Radiotherapy

Purpose: To study the correlations of the radiation biological equivalent doses (BED) along depth and lateral distance between LEM-1 and MKM approaches. Methods: In NIRS-MKM (Microdosimetric Kinetic Model) approach, the prescribed BED, referred as C-Eq, doses aims to present the relative biological effectiveness (RBE) for different energies of carbon-ions on a fixed 10% survival value of HCG cell with respect to convention X-ray. Instead of a fixed 10% survival, the BED doses of LEM-1 (Local Effect Model) approach, referred as X-Eq, aims to present the RBE over the whole survival curve of chordoma-like cell with alpha/beta ratio of 2.0. The relationship of physical doses as a function of C-Eq and X-Eq doses were investigated along depth and lateral distance for various sizes of cubic targets in water irradiated by carbon-ions. Results: At the center of each cubic target, the trends between physical and C-Eq or X-Eq doses can be described by a linear and 2nd order polynomial functions, respectively. Using fit functions can then calculate a scaling factor between C-Eq and X-Eq doses to have similar physical doses. With equalized C-Eq and X-Eq doses at the depth of target center, over- and under-estimated X-Eq to C-Eq are seen for depths before and after the target center, respectively. Near the distal edge along depth, sharp rising of RBE value is observed for X-Eq, but sharp dropping of RBE value is observed for C-Eq. For lateral locations near and just outside 50% dose level, sharp raising of RBE value is also seen for X-Eq, while only minor increasing with fast dropping for C-Eq. Conclusion: An analytical function to model the differences between the CEq and X-Eq doses along depth and lateral distance need to further investigated to explain varied clinic outcome of specific cancers using two different approaches to calculated BED doses.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

SU-F-T-132: Variable RBE Models Predict Possible Underestimation of Vaginal Dose for Anal Cancer Patients Treated Using Single-Field Proton Treatments

Purpose: Anal cancer patients treated using a posterior proton beam may be at risk of vaginal wall injury due to the increased linear energy transfer (LET) and relative biological effectiveness (RBE) at the beam distal edge. We investigate the vaginal dose received. Methods: Five patients treated for anal cancer with proton pencil beam scanning were considered, all treated to a prescription dose of 54 Gy(RBE) over 28–30 fractions. Dose and LET distributions were calculated using the Monte Carlo simulation toolkit TOPAS. In addition to the standard assumption of a fixed RBE of 1.1, variable RBE was considered via the application of published models. Dose volume histograms (DVHs) were extracted for the planning treatment volume (PTV) and vagina, the latter being used to calculate the vaginal normal tissue complication probability (NTCP). Results: Compared to the assumption of a fixed RBE of 1.1, the variable RBE model predicts a dose increase of approximately 3.3 ± 1.7 Gy at the end of beam range. NTCP parameters for the vagina are incomplete in the current literature, however, inferring value ranges from the existing data we use D{sub 50} = 50 Gy and LKB model parameters a=1–2 and m=0.2–0.4. We estimate the NTCP for the vagina to be 37–48% and 42–47% for the fixed and variable RBE cases, respectively. Additionally, a difference in the dose distribution was observed between the analytical calculation and Monte Carlo methods. We find that the target dose is overestimated on average by approximately 1–2%. Conclusion: For patients treated with posterior beams, the vaginal wall may coincide with the distal end of the proton beam and may receive a substantial increase in dose if variable RBE models are applied compared to using the current clinical standard of RBE equal to 1.1. This could potentially lead to underestimating toxicities when treating with protons.

60 APPLIED LIFE SCIENCES↗