Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reducing heat load”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Carbon Mitigation Potential of Heat Pump Integrated with Thermal Storage for Grid-Interactive Residential Buildings

Residential buildings’ heating and cooling loads are associated with significant carbon emissions and peak electricity demand. Phase change material (PCM) based thermal energy storage (TES) can be used for space heating and cooling by embedding into the heat pump equipment. Past work on TES integrated with heat pumps (HP) has demonstrated significant load shifting and economic benefits. However, the potential for TES to reduce carbon emissions has not been widely explored. This study evaluates carbon mitigation potential of an ice-based TES coupled to HP (HP-TES) based on a simple rule-based control strategy accounting for electric grid emissions data. A vapor compression HP model using Engineering Equation Solver (EES). The modeled HP-TES system for single-family residential building demonstrates decreased carbon emissions with reduced peak utility cost.

Sultan, Sara↗

How Can Floor Covering Influence Buildings’ Demand Flexibility?

Although the thermal mass of floors in buildings has been demonstrated to help shift cooling load, there is still a lack of information about how floor covering can influence the floor’s load shifting capability and buildings’ demand flexibility. To fill this gap, we estimated demand flexibility based on the daily peak cooling load reduction for different floor configurations and regions, using EnergyPlus simulations. As a demand response strategy, we used precooling and global temperature adjustment. The result demonstrated an adverse impact of floor covering on the building’s demand flexibility. Specifically, under the same demand response strategy, the daily peak cooling load reductions were up to 20–34% for a concrete floor whereas they were only 17–29% for a carpet-covered concrete floor. This is because floor covering hinders convective coupling between the concrete floor surface and the zone air and reduces radiative heat transfer between the concrete floor surface and the surrounding environment. In hot climates such as Phoenix, floor covering almost negated the concrete floor’s load shifting capability and yielded low demand flexibility as a wood floor, representing low thermal mass. Sensitivity analyses showed that floor covering’s effects can be more profound with a larger carpet-covered area, a greater temperature adjustment depth, or a higher radiant heat gain. With this effect ignored for a given building, its demand flexibility would be overestimated, which could prevent grid operators from obtaining sufficient demand flexibility to maintain a grid. Our findings also imply that for more efficient grid-interactive buildings, a traditional standard for floor design could be modified with increasing renewable penetration.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Additive-Mixing Fuel Injection (AMFI): A device for robust control and improved performance of high-efficiency LTGC engines

Low-temperature gasoline combustion (LTGC) engines can provide high efficiencies with very low NOx and particulate emissions. Despite these major advantages, methods for controlling LTGC combustion timing, achieving robust autoignition, and good low-load performance have challenged the development of practical LTGC engines. A key reason is that the ideal reactivity of the fuel varies with operating conditions, with low-reactivity fuels working well at high loads and higher-reactivity fuels working better at low loads. This article introduces a new technique called Additive Mixing Fuel Injection (AMFI) that adjusts the reactivity of the gasoline to obtain good performance over the operating map. Moreover, AMFI can provide robust combustion-timing control because it precisely meters very small amounts (0.01–0.6 mm 3 ) of an ignition-enhancing additive into the fuel each engine cycle. The additive used was 2-ethylhexyl nitrate (EHN), a common, inexpensive diesel-fuel ignition improver, but other additives could be used. Because additive amounts are so small, a 2-gal reservoir would be sufficient for medium-duty applications with refilling only at service intervals of about 8000 mi. The AMFI system has been installed on a single-cylinder LTGC research engine and demonstrated to provide robust combustion-timing control over wide ranges of combustion phasing, fueling rate, intake boost, engine speed, and intake temperature. AMFI also increases the fuel’s reactivity sufficiently to greatly reduce or eliminate the need for charge heating, simplifying engine design and significantly increasing thermal efficiency and the maximum load at low-boost conditions. The nitrogen in the EHN produced a modest increase in NOx, but it was mitigated by lower intake temperatures, and NOx emissions remained very low. Finally, the additive increases the sensitivity of autoignition reactions to variations in the local fuel/air mixture within the charge. This allows the use of controlled fuel stratification for improved LTGC-engine performance, and its potential to improve low-load operation was demonstrated.

Dec, John E.↗

Dual-season thermal energy storage-integrated heat pump system for load shifting: experiments, modeling and nationwide analysis

Here, this paper proposes and validates a dual-season thermal energy storage-integrated heat pump (TES-HP) system that shifts building electric load in both cooling and heating modes using a single phase-change TES. The design uses the TES as a heat sink for the condenser in summer and a heat source for the evaporator in winter, thereby reducing on-peak electric demand while ensuring compatible with existing air-distribution systems. A 14-kW TES-HP prototype with six operating modes and novel refrigerant charge management strategies was experimentally tested under varied conditions. Subsequently, data-driven polynomial performance curves were developed and validated against experiments, then coupled with a phase change material (PCM) model and a calibrated building model within a rule-based controller. Single-day case studies demonstrated effective on-peak demand reduction while maintaining thermal comfort. During cooling, hourly power was lowered by up to 1.5 kW; in heating, average hourly power decreased from over 3.5 kW to 1.8 kW, compared to an HP-only system, achieving 64.5 % load shifting, and the need for resistance heating was eliminated. Seasonal simulations showed typical on-peak electricity savings of 25–35 % in cooling and 40–65 % in heating, with the largest benefits on the hottest and coldest days. Extended response-surface analysis and nationwide mapping quantified load shifting as functions of ambient and TES temperatures, revealing a seasonal trade-off in TES phase-change temperature. These results demonstrate the TES-HP system as a practical and scalable solution for grid-interactive buildings that reduces on-peak demand and electricity use while maintaining thermal comfort and enhancing grid flexibility and reliability.

Grid-interactive buildings↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Overview of Wendelstein 7-X high-performance operation

The Wendelstein 7-X (W7-X) stellarator has completed two consecutive experimental campaigns OP 2.2 (Sep.-Dec. 2024) and OP 2.3 (Feb.-May 2025) under a new operational strategy enabling more than one year of uninterrupted device availability. This approach, supported by exceptionally high subsystem reliability, allowed sustained high-efficiency plasma operations with up to 80–100 discharges per day across a broad range of magnetic configurations. Several key technical upgrades-most notably the first operation of a 1.5 MW class steady-state gyrotron, a new steady-state pellet injector, and advanced real-time feedback control systems significantly enhanced heating, fueling, and plasma control capabilities. Together, these improvements enabled major advances in long-pulse performance, high-β operation, and confinement optimization. Long-pulse discharges achieved 1.8 GJ of injected energy under fully detached divertor conditions, while reduced-field scenarios facilitated record volume-averaged β values approaching 3%. High-performance plasmas with centrally peaked density profiles, created via neutral beam injection (NBI) or sustained pellet fueling, demonstrated strongly reduced turbulent transport and stellarator-record fusion triple products. Complementary studies of power exhaust and divertor heat loads revealed the role of scrape-off-layer drift physics in shaping strike-line patterns under attached conditions. Together, the results from OP 2.2 and OP 2.3 significantly expand the operational space of W7-X and strengthen its role as a leading platform for steady-state stellarator research and reactor-relevant plasma scenarios.

Wendelstein 7-X↗

Hydrogen Blending into Natural Gas Pipeline Infrastructure: Review of the State of Technology

Hydrogen is an energy carrier that could play an important role in reducing emissions associated with difficult-to-decarbonize sectors including peaking and load-following electricity and industrial heating. Blending hydrogen into the natural gas pipelines has been proposed as an approach for achieving near-term emissions reductions and early-market access for hydrogen technologies such as electrolyzers. Numerous challenges and uncertainties complicate this approach to natural gas decarbonization, however, and this review summarizes current research on the material, economic, and operational factors that must be considered for hydrogen blending. First, this review explores previous research regarding the effects of blending hydrogen on gas mixture fluid and thermodynamic properties, pipeline materials and equipment performance within transmission and distribution networks, and supporting facilities such as underground storage and end-use hydrogen separation. We also investigate and summarize studies that developed mathematical models of natural gas pipeline networks with hydrogen blending, and the operational and techno-economic findings of these network studies. Finally, we discuss notable hydrogen blending demonstrations and their key outcomes. Many blending demonstrations internationally have proven that low hydrogen percentage blending is feasible under very specific scenarios with limited end-usage applications on both high-pressure transmission lines and low-pressure distribution lines. This report summarizes findings from literature into key areas of consensus and disagreement. Research gaps and disagreements between the literature are highlighted to provide directions for future hydrogen blending research.

03 NATURAL GAS↗

High T(sub c) leads for remote sensing applications

Several NASA programs designed to monitor the Earth's atmosphere from space utilize infrared detectors which operate at or below 4.2 K for optimum performance. At present, the detectors are maintained at cryogenic temperatures by a stored volume of liquid helium. These detectors must be electrically linked to amplification electronics data storage instruments maintained at 80 K. The electrical connections over the temperature gradient account for approximately 20% of the total heat load on the Dewar for some systems, accelerating the boil-off of liquid helium cryogen and reducing the operational lifetime of the space-borne instruments. The recent discovery of high temperature superconductors has provided an opportunity to develop electrically conductive, thermally insulating links to bridge this thermal gradient. This paper describes the modelling of the thermal transport properties of thick film, high T(sub c) electrical bridges across a 4.2-80 K temperature gradient and the impact of such devices on a spaceborne remote sensing system.

Selim, R.↗

Variable Emittance Coatings

Variable emittance coatings (VECs) can reduce thermal control system mass and power by passively changing radiator heat rejection according to spacecraft and environment heat loads. VECs make establishing a lunar presence easier since this technology helps overcome challenges with harsh thermal environments on the lunar surface and in transit. This CIF focuses on creating testing capabilities to assess VECs from collaborators in academia and industry. Two main testing capabilities were created. First, a set of temperature dependent Fourier Transform Infrared Spectroscopy (FTIR) measurement accessories were designed, fabricated, and used to measure samples received from collaborators. These accessories are capable of measuring the transmittance and reflectance of semi transparent and opaque samples. Second, a vacuum calorimetry experiment was designed and built to assess the variable heat rejection of larger coupons.

Sydney Taylor↗

Electron Cloud Simulations for the Electron-Ion Collider in Brookhaven National Laboratory

For high-intensity circular accelerators and storage rings, if the secondary electron emission yield (SEY) of the vacuum chamber surfaces is high, an EC (Electron Cloud) could build up with the passage of the circulating beam. The presence of EC can strongly affect the beam quality, such as transverse instabilities, transverse emittance growth, and beam loss. Furthermore, the heat load from EC can exceed the available cryogenic capability. For the RHIC superconducting (SC) arc magnets, to be used for the hadron storage ring of the Electron-Ion Collider (EIC), the dynamic heat load budget is 0.5 W/m to the 4.5 K stainless steel beam pipe. This can limit the maximum beam bunches or intensity of the EIC, hence diminishing the luminosity provided by the EIC. The EC has affected the beam instability and significantly contributed to cryogenic heat load in the Large Hadron Collider (LHC). Positron storage rings for which ECs have been a critical factor in the design and performance include KEKB in Japan and EC buildup remains one of the concerns for future high-intensity accelerators design. EC considerations have driven the SuperKEKB collider design and the positron damping ring for the proposed International Linear Collider (ILC). The LHC luminosity upgrade is contingent on reducing the bunch spacing to 25 ns; at this bunch spacing, severe EC buildup has been observed. The success of the upgrade is likely contingent on limiting EC buildup. To study the EC heat load, we did some EC simulations with PyECLOUD code for the dipole, quadrupole, sextupole magnets, and the warm (drift) section of the EIC hadron storage ring. PyECLOUD is an EC simulation code developed by CERN. The code has been validated and used to study EC in the LHC, SPS, and PS. To eliminate EC buildup, the sources of electrons must be minimized. First, we will reduce the production of electrons due to residual gas ionization by specifying the maximum gas density, which requires a vacuum chamber with low electron-stimulated desorption (ESD) yields and a sufficient (preferably distributed) pumping speed. Second, we should reduce the secondary electrons with a lower secondary electron yield (SEY) material.

43 PARTICLE ACCELERATORS↗

Advanced radiator systems for space power

Space power systems generating powers of 1 MWe and higher will require new approaches in radiator design in order to reject large waste heat loads without the unmanageable weight burden of conventional pumped-loop radiator systems. This paper discusses recent design concepts for radiator systems which have the potential for reducing radiator mass by as much as an order of magnitude below the mass of conventional systems. These advanced concepts, including the heat pipe radiator, particle (dust and droplet) radiators, moving belt radiator, rotating membrane radiator, and several interesting variations of these, achieve low mass by reducing the armor requirement for protection against micrometeoroids. The design and performance of each of these concepts is discussed, along with technical issues which must be addressed to bring these concepts to fruition.

Mattick, A. T.↗

An Approach to High-Performance Affordable Housing Using Point-Source Space Conditioning

This project explored the use of minisplit ductless heat pumps in combination with small through-wall transfer fans to provide space conditioning in small single-story homes, including manufactured homes and homes built by Habitat for Humanity. The objectives were to reduce space-conditioning energy consumption by 50% compared to the 2009 International Energy Conservation Code (ICC 2009) while maintaining home affordability and thermal comfort. The strategy to achieve this goal also included a highly efficient thermal envelope to reduce space-conditioning loads.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Combined Heat and Power Technology Fact Sheet Series: District Energy

This fact sheet provides an overview of district energy systems, which are characterized by one or more central plants producing hot water, steam, and/or chilled water, which then flows through a network of insulated pipes to provide hot water, space heating, and/or air conditioning for nearby buildings. District energy systems serve a variety of end-use markets, including downtowns (central business districts), college and university campuses, hospitals and healthcare facilities, airports, military bases, and industrial complexes. By combining loads for multiple buildings, district energy systems create economies of scale that help reduce energy costs and enable the use of high-efficiency technologies such as combined heat and power (CHP).

Combined Heat and Power, CHP, District Energy, Tec↗

Magnetogasdynamic Power Extraction and Flow Conditioning for a Gas Turbine

An extension of the Russian AJAX concept to a turbojet is being explored. This magnetohydrodynamic (MHD) energy bypass engine cycle incorporating conventional gas turbine technology has MHD flow conditioning at the inlet to electromagnetically extract part of the inlet air kinetic energy. The electrical power generated can be used for various on-board vehicle requirements including plasma flow control around the vehicle or it may be used for augmenting the expanding flow in the high speed nozzle by MHD forces to generate more thrust. In order to achieve this interaction, the air needs to be ionized by an external means even up to fairly high flight speeds, and the leading candidates may be classified as electrical discharge devices. The present kinetic modeling calculations suggest that the use of electron beams with characteristics close to the commercially available e-beam systems (electron energy approx. 60 keV, beam current approx. 0.2 mA/sq cm) to sustain ionization in intermediate pressure, low-temperature (P = 0.1 atm, T = 300 K) supersonic air flows allows considerable reduction of the flow kinetic energy (up to 10 to 20 percent in M = 3 flows). The calculations also suggest that this can be achieved at a reasonable electron beam efficiency (eta approx. 5), even if the e-beam window losses are taken into account. At these conditions, the exit NO and O atom concentrations due to e-beam initiated chemical reactions do not exceed 30 ppm. Increasing the beam current up to approx. 2 mA/sq cm, which corresponds to a maximum electrical conductivity of sigma(sub max) approx. 0.8 mho/m at the loading parameter of K = 0.5, would result in a much greater reduction of the flow kinetic energy (up to 30 to 40 percent). The MHD channel efficiency at these conditions would be greatly reduced (to eta approx. 1) due to increased electron recombination losses in the channel. At these conditions, partial energy conversion from kinetic energy to heat would result in a significant total pressure loss (P(sub 0)/P(sub 0i) approx. 0.3). The total pressure loss can be reduced operating at the loading parameter closer to unity, at the expense of the reduced electrical power output. Raising the beam current would also result in the increase of the exit O atom concentrations (up to 600 ppm) and NO (up to 150 ppm).

Adamovich, Igor V.↗

Status and performance of the GlueX DIRC

In support of the future physics program at Ce+BAF, we propose a prototype positron target. The prototype target consists of a tungsten disk mounted on a water-cooled copper support structure to enhance heat removal. The primary goals of this work are to benchmark CFD simulations, ensure vacuum integrity at the 10^-6 Pa level, achieve stable target rotation up to 10 Hz, and implement efficient water-based cooling for sustained high-power operation. To manage the thermal load, the target is designed to rotate, allowing the deposited heat to spread over a larger region, and thereby reducing localized thermal stress while maintaining the maximum temperature below 1000 K. To experimentally evaluate the thermal performance and structural stability of the target, we plan to conduct high-power laser heating tests at Laser Lab 5, LERF Building, JLab. These tests will serve as a stepping-stone for the positron production target at CEBAF.

Stevens, J.R. [College of William and Mary, Willia↗

Large-Scale Covariability Between Aerosol and Precipitation Over the 7-SEAS Region: Observations and Simulations

One of the seven scientific areas of interests of the 7-SEAS field campaign is to evaluate the impact of aerosol on cloud and precipitation (http://7-seas.gsfc.nasa.gov). However, large-scale covariability between aerosol, cloud and precipitation is complicated not only by ambient environment and a variety of aerosol effects, but also by effects from rain washout and climate factors. This study characterizes large-scale aerosol-cloud-precipitation covariability through synergy of long-term multi ]sensor satellite observations with model simulations over the 7-SEAS region [10S-30N, 95E-130E]. Results show that climate factors such as ENSO significantly modulate aerosol and precipitation over the region simultaneously. After removal of climate factor effects, aerosol and precipitation are significantly anti-correlated over the southern part of the region, where high aerosols loading is associated with overall reduced total precipitation with intensified rain rates and decreased rain frequency, decreased tropospheric latent heating, suppressed cloud top height and increased outgoing longwave radiation, enhanced clear-sky shortwave TOA flux but reduced all-sky shortwave TOA flux in deep convective regimes; but such covariability becomes less notable over the northern counterpart of the region where low ]level stratus are found. Using CO as a proxy of biomass burning aerosols to minimize the washout effect, large-scale covariability between CO and precipitation was also investigated and similar large-scale covariability observed. Model simulations with NCAR CAM5 were found to show similar effects to observations in the spatio-temporal patterns. Results from both observations and simulations are valuable for improving our understanding of this region's meteorological system and the roles of aerosol within it. Key words: aerosol; precipitation; large-scale covariability; aerosol effects; washout; climate factors; 7- SEAS; CO; CAM5

Huang, Jingfeng↗

Thermoacoustic environments to simulate reentry conditions

Aerothermal environments as encountered during the reentry of spaceplanes or during the cruise of hypersonic aircrafts represent complex loading conditions for the external structures of those vehicles. In order to shield against the aerodynamic heating a special Thermal Protection System (TPS) is required which is designed as a light weight structure to reduce the weight penalty. TPS is therefore vulnerable to vibroacoustic fatigue caused by the pressure fluctuations of the environment. Because of the complex interactions between the loading forces and the resulting structural response which make an analytical treatment difficult and in order to provide means for fatigue testing IABG has designed and built a thermoacoustic facility which recently became operational. The facility is capable to produce surface temperatures up to 1.300 C at sound pressure levels up to 160 dB. This paper describes the design of the facility, some operational test work it also deals with problems associated with the facility instrumentation.

Bayerdoerfer, Gerhard↗