Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Reconstruction algorithms”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

SU-D-210-03: Limited-View Multi-Source Quantitative Photoacoustic Tomography

Purpose: This work is to investigate a novel limited-view multi-source acquisition scheme for the direct and simultaneous reconstruction of optical coefficients in quantitative photoacoustic tomography (QPAT), which has potentially improved signal-to-noise ratio and reduced data acquisition time. Methods: Conventional QPAT is often considered in two steps: first to reconstruct the initial acoustic pressure from the full-view ultrasonic data after each optical illumination, and then to quantitatively reconstruct optical coefficients (e.g., absorption and scattering coefficients) from the initial acoustic pressure, using multi-source or multi-wavelength scheme.Based on a novel limited-view multi-source scheme here, We have to consider the direct reconstruction of optical coefficients from the ultrasonic data, since the initial acoustic pressure can no longer be reconstructed as an intermediate variable due to the incomplete acoustic data in the proposed limited-view scheme. In this work, based on a coupled photo-acoustic forward model combining diffusion approximation and wave equation, we develop a limited-memory Quasi-Newton method (LBFGS) for image reconstruction that utilizes the adjoint forward problem for fast computation of gradients. Furthermore, the tensor framelet sparsity is utilized to improve the image reconstruction which is solved by Alternative Direction Method of Multipliers (ADMM). Results: The simulation was performed on a modified Shepp-Logan phantom to validate the feasibility of the proposed limited-view scheme and its corresponding image reconstruction algorithms. Conclusion: A limited-view multi-source QPAT scheme is proposed, i.e., the partial-view acoustic data acquisition accompanying each optical illumination, and then the simultaneous rotations of both optical sources and ultrasonic detectors for next optical illumination. Moreover, LBFGS and ADMM algorithms are developed for the direct reconstruction of optical coefficients from the acoustic data. Jing Feng and Hao Gao were partially supported by the NSFC (#11405105), the 973 Program (#2015CB856000) and the Shanghai Pujiang Talent Program (#14PJ1404500)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Model-based iterative reconstruction with adaptive regularization for artifact reduction in electron tomography

Obtaining high-quality 3D reconstructions from electron tomography of crystalline particles embedded in lighter support elements is crucial for various material systems such as catalysts for fuel cell applications. However, significant challenges arise due to the limited tilt range, sparse and low signal-to-noise ratio of the measurements. In addition, small metal particles can cause strong streaking and shading artifacts in the 3D reconstructions when using conventional reconstruction algorithms due to the presence of Bragg diffraction and the large scattering cross-section difference between the materials of the particles and the background support regions. These artifacts lead to errors in the downstream characterization affecting extraction of critical features such as the size of the metal particles, their distribution and the volume of the lighter support regions. In this paper, we present a two-stage algorithm based on metal artifact reduction, utilizing model-based iterative reconstruction methods with adaptive adjustment of regularization parameters. Our approach yields high-quality 3D reconstructions compared to traditional algorithms, accurately capturing both the metal particles as well as the background support. We demonstrate the effectiveness of our algorithm through simulated and experimental bright-field electron tomography data, showing significant improvements in reconstruction quality compared to traditional methods.

97 MATHEMATICS AND COMPUTING↗

Iterative reconstruction techniques for industrial CT: application and performance

BWXT Y-12, Oak Ridge National Laboratory, and the University of Tennessee have been working toward improved high-resolution X-ray computed tomography for non-destructive testing of manufactured objects. The emphasis of this work has been on iterative reconstruction, calibration, and performance testing. Algebraic reconstruction algorithms for CT have been developed that are more robust in handling incomplete and noisy data and permit high-resolution volumetric imaging on metallic part assemblies. A key source of artifacts in reconstructed CT images for industrial components is poor image statistics due to areas of high attenuation. This loss of information in the captured projections not only affects reconstruction of those areas, but also the surrounding regions. To overcome numerical instabilities arising from the ill-posed nature of inverse problems, standard regularization techniques can be applied as can Bayesian reconstruction techniques using prior data such as CAD information to improve image quality. To accelerate the reconstruction of certain regions of interest and reduce memory requirements, subvolume reconstruction has been implemented and tested. A computational framework has been implemented that facilitates the use of sophisticated iterative algorithms for reconstruction of three-dimensional images from high-resolution X-ray cone-beam projection data. The code supports parallel computing at two levels: message passing is used to farm the computation out across a network of computers while threads allow all processors available on any one computer to be used.

99 GENERAL AND MISCELLANEOUS↗

MO-DE-210-06: Development of a Supercompounded 3D Volumetric Ultrasound Image Guidance System for Prone Accelerated Partial Breast Irradiation (APBI)

Purpose: For early-stage breast cancer, accelerated partial breast irradiation (APBI) is a cost-effective breast-conserving treatment. Irradiation in a prone position can mitigate respiratory induced breast movement and achieve maximal sparing of heart and lung tissues. However, accurate dose delivery is challenging due to breast deformation and lumpectomy cavity shrinkage. We propose a 3D volumetric ultrasound (US) image guidance system for accurate prone APBI Methods: The designed system, set beneath the prone breast board, consists of a water container, an US scanner, and a two-layer breast immobilization cup. The outer layer of the breast cup forms the inner wall of water container while the inner layer is attached to patient breast directly to immobilization. The US transducer scans is attached to the outer-layer of breast cup at the dent of water container. Rotational US scans in a transverse plane are achieved by simultaneously rotating water container and transducer, and multiple transverse scanning forms a 3D scan. A supercompounding-technique-based volumetric US reconstruction algorithm is developed for 3D image reconstruction. The performance of the designed system is evaluated with two custom-made gelatin phantoms containing several cylindrical inserts filled in with water (11% reflection coefficient between materials). One phantom is designed for positioning evaluation while the other is for scaling assessment. Results: In the positioning evaluation phantom, the central distances between the inserts are 15, 20, 30 and 40 mm. The distances on reconstructed images differ by −0.19, −0.65, −0.11 and −1.67 mm, respectively. In the scaling evaluation phantom, inserts are 12.7, 19.05, 25.40 and 31.75 mm in diameter. Measured inserts’ sizes on images differed by 0.23, 0.19, −0.1 and 0.22 mm, respectively. Conclusion: The phantom evaluation results show that the developed 3D volumetric US system can accurately localize target position and determine target volume, and is a promising image-guidance tool for prone APBI.

60 APPLIED LIFE SCIENCES↗

Effective regularized algebraic reconstruction technique for computed tomography

A new fast version of the reconstruction algorithm for computed tomography based on the simultaneous algebraic reconstruction technique (SART) is proposed. The algorithm iteration is asymptotically accelerated using the fast Hough transform from O(n{sup 3}) to O(n{sup 2}logn). Similarly to the algebraic reconstruction technique (RegART), which was proposed by us previously, the regularization operator is applied after each iteration. A bilateral filter plays the role of this operator. The algorithm behavior is investigated using the model experiment.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

TDCOSMO. IX. Systematic comparison between lens modelling software programs: time delay prediction for WGD 2038-4008

The importance of alternative methods for measuring the Hubble constant, such as time-delay cosmography, is highlighted by the recent Hubble tension. It is paramount to thoroughly investigate and rule out systematic biases in all measurement methods before we can accept new physics as the source of this tension. In this study, we perform a check for systematic biases in the lens modelling procedure of time-delay cosmography by comparing independent and blind time-delay predictions of the system WGD 2038-4008 from two teams using two different software programs: GLEE and LENSTRONOMY. The predicted time delays from the two teams incorporate the stellar kinematics of the deflector and the external convergence from line-of-sight structures. The un-blinded time-delay predictions from the two teams agree within 1.2σ, implying that once the time delay is measured the inferred Hubble constant will also be mutually consistent. However, there is a ~4σ discrepancy between the power-law model slope and external shear, which is a significant discrepancy at the level of lens models before the stellar kinematics and the external convergence are incorporated. We identify the difference in the reconstructed point spread function (PSF) to be the source of this discrepancy. When the same reconstructed PSF was used by both teams, we achieved excellent agreement, within ~0.6σ<, indicating that potential systematics stemming from source reconstruction algorithms and investigator choices are well under control. We recommend that future studies supersample the PSF as needed and marginalize over multiple algorithms or realizations for the PSF reconstruction to mitigate the systematics associated with the PSF. A future study will measure the time delays of the system WGD 2038-4008 and infer the Hubble constant based on our mass models.

79 ASTRONOMY AND ASTROPHYSICS↗

Motion-map constrained image reconstruction (MCIR): Application to four-dimensional cone-beam computed tomography

Purpose: Utilization of respiratory correlated four-dimensional cone-beam computed tomography (4DCBCT) has enabled verification of internal target motion and volume immediately prior to treatment. However, with current standard CBCT scan, 4DCBCT poses challenge for reconstruction due to the fact that multiple phase binning leads to insufficient number of projection data to reconstruct and thus cause streaking artifacts. The purpose of this study is to develop a novel 4DCBCT reconstruction algorithm framework called motion-map constrained image reconstruction (MCIR), that allows reconstruction of high quality and high phase resolution 4DCBCT images with no more than the imaging dose as well as projections used in a standard free breathing 3DCBCT (FB-3DCBCT) scan.Methods: The unknown 4DCBCT volume at each phase was mathematically modeled as a combination of FB-3DCBCT and phase-specific update vector which has an associated motion-map matrix. The motion-map matrix, which is the key innovation of the MCIR algorithm, was defined as the matrix that distinguishes voxels that are moving from stationary ones. This 4DCBCT model was then reconstructed with compressed sensing (CS) reconstruction framework such that the voxels with high motion would be aggressively updated by the phase-wise sorted projections and the voxels with less motion would be minimally updated to preserve the FB-3DCBCT. To evaluate the performance of our proposed MCIR algorithm, we evaluated both numerical phantoms and a lung cancer patient. The results were then compared with the (1) clinical FB-3DCBCT reconstructed using the FDK, (2) 4DCBCT reconstructed using the FDK, and (3) 4DCBCT reconstructed using the well-known prior image constrained compressed sensing (PICCS).Results: Examination of the MCIR algorithm showed that high phase-resolved 4DCBCT with sets of up to 20 phases using a typical FB-3DCBCT scan could be reconstructed without compromising the image quality. Moreover, in comparison with other published algorithms, the image quality of the MCIR algorithm is shown to be excellent.Conclusions: This work demonstrates the potential for providing high-quality 4DCBCT during on-line image-guided radiation therapy (IGRT), without increasing the imaging dose. The results showed that (at least) 20 phase images could be reconstructed using the same projections data, used to reconstruct a single FB-3DCBCT, without streak artifacts that are caused by insufficient projections.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

SU-D-206-02: Evaluation of Partial Storage of the System Matrix for Cone Beam Computed Tomography Using a GPU Platform

Purpose: Iterative reconstruction algorithms in computed tomography (CT) require a fast method for computing the intersections between the photons’ trajectories and the object, also called ray-tracing or system matrix computation. This work evaluates different ways to store the system matrix, aiming to reconstruct dense image grids in reasonable time. Methods: We propose an optimized implementation of the Siddon’s algorithm using graphics processing units (GPUs) with a novel data storage scheme. The algorithm computes a part of the system matrix on demand, typically, for one projection angle. The proposed method was enhanced with accelerating options: storage of larger subsets of the system matrix, systematic reuse of data via geometric symmetries, an arithmetic-rich parallel code and code configuration via machine learning. It was tested on geometries mimicking a cone beam CT acquisition of a human head. To realistically assess the execution time, the ray-tracing routines were integrated into a regularized Poisson-based reconstruction algorithm. The proposed scheme was also compared to a different approach, where the system matrix is fully pre-computed and loaded at reconstruction time. Results: Fast ray-tracing of realistic acquisition geometries, which often lack spatial symmetry properties, was enabled via the proposed method. Ray-tracing interleaved with projection and backprojection operations required significant additional time. In most cases, ray-tracing was shown to use about 66 % of the total reconstruction time. In absolute terms, tracing times varied from 3.6 s to 7.5 min, depending on the problem size. The presence of geometrical symmetries allowed for non-negligible ray-tracing and reconstruction time reduction. Arithmetic-rich parallel code and machine learning permitted a modest reconstruction time reduction, in the order of 1 %. Conclusion: Partial system matrix storage permitted the reconstruction of higher 3D image grid sizes and larger projection datasets at the cost of additional time, when compared to the fully pre-computed approach. This work was supported in part by the Fonds de recherche du Quebec - Nature et technologies (FRQ-NT). The authors acknowledge partial support by the CREATE Medical Physics Research Training Network grant of the Natural Sciences and Engineering Research Council of Canada (Grant No. 432290).

60 APPLIED LIFE SCIENCES↗

Cryo-STEM Tomography with Inpainting

Traditionally, microscopists have worked with the Nyquist-Shannon theory of sampling, which states that to be able to reconstruct the image fully it needs to be sampled at a rate of at least twice the highest spatial frequency in the image. This sampling rate assumes that the image is sampled at regular intervals and that every pixel contains information that is crucial for the image (it even assumes that noise is important). Images in general, and especially low dose S/TEM images, contain significantly less information than can be encoded by a grid of pixels (which is why image compression works). Mathematically speaking, the image data has a low dimensional or sparse representation. Through the application of compressive sensing methods [1,2,3] this representation can be found using pre-designed measurements that are usually random for implementation simplicity. These measurements and the compressive sensing reconstruction algorithms have the added benefit of reducing noise. This reconstruction approach can be extended into higher dimensions, whereby the random sampling in each 2-D image can be extended into: a sequence of tomographic projections (i.e. tilt images); a sequence of video frames (i.e. incorporating temporal resolution and dynamics); spectral resolution (i.e. energy filtering an image to see the distribution of elements); and ptychography (i.e. sampling a full diffraction image at each location in a 2-D grid across the sample). This approach has been employed experimentally for materials science samples requiring low-dose imaging [2], and can be readily applied to biological samples. Figure 1 shows the resolution possible in a complex biological system, mouse pancreatic islet beta cells [4], when tomogram slices are reconstructed using subsampling. Reducing the number of pixels (1/6 pix and 1/3*1/3) shows minimal degradation compared to the reconstructions using all pixels (all data and 1/3 tilt). Although subsampling 1/6 of the tilts (1/6 of overall dose) degrades the reconstruction to the point that the cellular structures cannot be identified. Using 1/3 of both the pixels and the tilts provides a high quality image at 1/9 the overall dose even for this most basic and rapid demonstration of the CS methods. Figure 2 demonstrates the theoretical tomogram reconstruction quality (vertical axis) as undersampling (horizontal axis) is increased; we examined subsampling pixels and tilt-angles individually and a combined approach in which both pixels and tilts are sub-sampled. Note that subsampling pixels maintains high quality reconstructions (solid lines). Using the inpainting algorithm to obtain tomograms can automatically reduce the dose applied to the system by an order of magnitude. Perhaps the best way to understand the impact is to consider that by using inpainting (and with minimal hardware changes), a sample that can normally withstand a dose of ~10 e/Å2 can potentially be imaged with an “equivalent quality” to a dose level of 103 e/Å2. To put this in perspective, this is approaching the dose level used for the most advanced images, in terms of spatial resolution, for inorganic systems. While there are issues for biological specimens beyond dose (structural complexity being the most important one), this sampling approach allows the methods that are traditionally used for materials science to be applied to biological systems [5]. References: [1] A Stevens, H Yang, L Carin et al. Microscopy 63(1), (2014), pp. 41. [2] L Kovarik, A Stevens, A Liyu et al. Appl. Phys. Lett. 109, 164102 (2016) [3] A Stevens, L Kovarik, P Abellan et al. Adv. Structural and Chemical Imaging 1(10), (2015), pp. 1. [4] MD Guay, W Czaja, MA Aronova et al. Scientific Reports 6, 27614 (2016) [5] Supported by the Chemical Imaging, Signature Discovery, and Analytics in Motion Initiatives at PNNL. PNNL is operated by Battelle Memorial Inst. for the US DOE; contract DE-AC05-76RL01830.

Stevens, Andrew↗

Patient-bounded extrapolation using low-dose priors for volume-of-interest imaging in C-arm CT

Purpose: Three-dimensional (3D) volume-of-interest (VOI) imaging with C-arm systems provides anatomical information in a predefined 3D target region at a considerably low x-ray dose. However, VOI imaging involves laterally truncated projections from which conventional reconstruction algorithms generally yield images with severe truncation artifacts. Heuristic based extrapolation methods, e.g., water cylinder extrapolation, typically rely on techniques that complete the truncated data by means of a continuity assumption and thus appear to be ad-hoc. It is our goal to improve the image quality of VOI imaging by exploiting existing patient-specific prior information in the workflow. Methods: A necessary initial step prior to a 3D acquisition is to isocenter the patient with respect to the target to be scanned. To this end, low-dose fluoroscopic x-ray acquisitions are usually applied from anterior–posterior (AP) and medio-lateral (ML) views. Based on this, the patient is isocentered by repositioning the table. In this work, we present a patient-bounded extrapolation method that makes use of these noncollimated fluoroscopic images to improve image quality in 3D VOI reconstruction. The algorithm first extracts the 2D patient contours from the noncollimated AP and ML fluoroscopic images. These 2D contours are then combined to estimate a volumetric model of the patient. Forward-projecting the shape of the model at the eventually acquired C-arm rotation views gives the patient boundary information in the projection domain. In this manner, we are in the position to substantially improve image quality by enforcing the extrapolated line profiles to end at the known patient boundaries, derived from the 3D shape model estimate. Results: The proposed method was evaluated on eight clinical datasets with different degrees of truncation. The proposed algorithm achieved a relative root mean square error (rRMSE) of about 1.0% with respect to the reference reconstruction on nontruncated data, even in the presence of severe truncation, compared to a rRMSE of 8.0% when applying a state-of-the-art heuristic extrapolation technique. Conclusions: The method we proposed in this paper leads to a major improvement in image quality for 3D C-arm based VOI imaging. It involves no additional radiation when using fluoroscopic images that are acquired during the patient isocentering process. The model estimation can be readily integrated into the existing interventional workflow without additional hardware.

60 APPLIED LIFE SCIENCES↗

Dragonfly : an implementation of the expand–maximize–compress algorithm for single-particle imaging

Single-particle imaging (SPI) with X-ray free-electron lasers has the potential to change fundamentally how biomacromolecules are imaged. The structure would be derived from millions of diffraction patterns, each from a different copy of the macromolecule before it is torn apart by radiation damage. The challenges posed by the resultant data stream are staggering: millions of incomplete, noisy and un-oriented patterns have to be computationally assembled into a three-dimensional intensity map and then phase reconstructed. In this paper, the Dragonfly software package is described, based on a parallel implementation of the expand–maximize–compress reconstruction algorithm that is well suited for this task. Auxiliary modules to simulate SPI data streams are also included to assess the feasibility of proposed SPI experiments at the Linac Coherent Light Source, Stanford, California, USA.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

tomoCAM : fast model-based iterative reconstruction via GPU acceleration and non-uniform fast Fourier transforms

X-ray-based computed tomography is a well established technique for determining the three-dimensional structure of an object from its two-dimensional projections. In the past few decades, there have been significant advancements in the brightness and detector technology of tomography instruments at synchrotron sources. These advancements have led to the emergence of new observations and discoveries, with improved capabilities such as faster frame rates, larger fields of view, higher resolution and higher dimensionality. These advancements have enabled the material science community to expand the scope of tomographic measurements towards increasingly in situ and in operando measurements. In these new experiments, samples can be rapidly evolving, have complex geometries and restrictions on the field of view, limiting the number of projections that can be collected. In such cases, standard filtered back-projection often results in poor quality reconstructions. Iterative reconstruction algorithms, such as model-based iterative reconstructions (MBIR), have demonstrated considerable success in producing high-quality reconstructions under such restrictions, but typically require high-performance computing resources with hundreds of compute nodes to solve the problem in a reasonable time. Here, tomoCAM , is introduced, a new GPU-accelerated implementation of model-based iterative reconstruction that leverages non-uniform fast Fourier transforms to efficiently compute Radon and back-projection operators and asynchronous memory transfers to maximize the throughput to the GPU memory. The resulting code is significantly faster than traditional MBIR codes and delivers the reconstructive improvement offered by MBIR with affordable computing time and resources. tomoCAM has a Python front-end, allowing access from Jupyter -based frameworks, providing straightforward integration into existing workflows at synchrotron facilities.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

Study of $\pi^0$ Events in MicroBooNE and Applications to the Deep Learning LEE Search

We present a selection of events containing $\pi^0$ particles in the MicroBooNE detector. These events are used to understand the important pi0 background in the deep learning (DL) based electron low energy excess (e-LEE) analysis. The selection uses a new shower reconstruction algorithm based on tools in the DL reconstruction chain. We present the efficiency and energy resolution of the selection. We also present the planned use of these events in energy calibration using the reconstructed $\pi^0$ mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Algorithm For Enlargement Of Digitized Images

Digital Image Enlarging Balanced Reconstruction Algorithm (DIEBRA) enlarges digitized image composed of square pixels to make image look more like real scene. Synthesizes enlarged image at greater number of pixels, smoothing out blockiness while providing resolution finer than original pixels and closer to scene. Based on more-realistic treatment of pixels, not as points but as areas representing spatial-resolution elements or fields of view of imaging instrument.

Rhea, William J.↗

Application of Monte Carlo Algorithms to Cardiac Imaging Reconstruction

Monte Carlo algorithms have a growing impact on nuclear medicine reconstruction processes. One ofthe main limitations of myocardial perfusion imaging (MPI) is the effective mitigation of the scattering component,which is particularly challenging in Single Photon Emission Computed Tomography (SPECT). In SPECT,no timing information can be retrieved to locate the primary source photons. Monte Carlo methods allow anevent-by-event simulation of the scattering kinematics, which can be incorporated into a model of the imagingsystem response. This approach was adopted in the late Nineties by several authors, and recently took advantageof the increased computational power made available by high-performance CPUs and GPUs. These recent developmentsenable a fast image reconstruction with improved image quality, compared to deterministic approaches.Deterministic approaches are based on energy-windowing of the detector response, and on the cumulative estimateand subtraction of the scattering component. In this paper, we review the main strategies and algorithms tocorrect the scattering effect in SPECT and focus on Monte Carlo developments, which nowadays allow the threedimensionalreconstruction of SPECT cardiac images in a few seconds.

Pharmacology & Pharmacy↗

Algorithm-Driven Advances for Scientific CT Instruments: From model-based to deep learning-based approaches

Multiscale 3D characterization is widely used by materials scientists to further their understanding of the relationships between microscopic structure and macroscopic function. Scientific computed tomography (SCT) instruments are one of the most popular choices for 3D nondestructive characterization of materials at length scales ranging from the angstrom scale to the micron scale. These instruments typically have a source of radiation (such as electrons, X-rays, or neutrons) that interacts with the sample to be studied and a detector assembly to capture the result of this interaction (see Figure 1 ). A collection of such high-resolution measurements is made by reorienting the sample, which is mounted on a specially designed stage/holder after which reconstruction algorithms are used to produce the final 3D volume of interest. The specific choice of which instrument to use depends on the desired resolution and properties of the materials being imaged. Additionally, the end goal of SCT scans includes determining the morphology, chemical composition, or dynamic behavior of materials when subjected to external stimuli. In summary, SCT instruments are powerful tools that enable 3D characterization across multiple length scales and play a critical role in furthering the understanding of the structure–function relationships of different materials.

42 ENGINEERING↗

Evaluation of the Reconstruction Accuracy of the Ultrasound Model–Based Image Reconstruction (U-MBIR) Method for Concrete to Optimize Damage Detection

Reinforced concrete is a critical structural material used to construct nuclear power plants (NPPs). As such, its safety and performance must be thoroughly examined throughout the life cycle of the NPP infrastructure system. Ultrasonic measurements have been an industry standard for both surface and subsurface inspections. To support the development of these techniques, Oak Ridge National Laboratory (ORNL) has researched and developed advanced image reconstruction algorithms to capture internal damage. The results and discussion presented herein summarize the current state of the ultrasonic model–based iterative reconstruction (U-MBIR) algorithm developed at ORNL. In the work documented in this report, the U-MBIR methodology was applied to four sets of ultrasonic data collected from concrete specimens. The results demonstrate that the U-MBIR algorithm can successfully detect defects within the four concrete samples. The reconstruction images help identify the specimen thickness, regions of delamination, and location of rebar embedded within the concrete. The reconstruction images allow engineers and technicians to characterize the internal defects within concrete specimens and structural members. Ultimately, this knowledge can guide engineers in making informed decisions regarding the performance, safety, and reliability of structural materials (i.e., reinforced concrete) throughout the life cycle of NPPs.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗