Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Raman”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Synthesis and characterization of mixed monolayer protected gold nanorods and their Raman activities

Graphical abstract: Gold nanorods surface functionalization. - Highlights: • Mixed monolayer protected gold nanorods. • Surface enhanced Raman spectroscopy. • HS-(CH{sub 2}){sub 11}-NHCO-coumarin as a Raman active compound. - Abstract: The cetyltrimethylammonium bromide (CTAB) gold nanorods (AuNRs) were prepared by seed-mediated route followed by the addition of a Raman active compound (HS-(CH{sub 2}){sub 11}-NHCO-coumarin) on the gold nanorods surfaces. Different stoichiometric mixtures of HS-(CH{sub 2}){sub 11}-NHCO-coumarin and HS-PEG-(CH{sub 2}){sub 11}COOH were evaluated for their Raman activities. The lowest stoichiometric ratio HS-(CH{sub 2}){sub 11}-NHCO-coumarin adsorbed on gold nanorods surface was detected and enhanced by Raman spectroscopy. The produced mixed monolayer protected gold nanorods were characterized by UV-vis spectrometer for optical properties, transmission electron microscope (TEM) for structural properties (shape and aspect ratio) and their zeta potentials (charges) were obtained from ZetaSizer to determine the stability of the produced mixed monolayer protected gold nanorods. The Raman results showed a surface enhanced Raman scattering (SERS) enhancement at the lowest stoichiometric ratio of 1% HS-(CH{sub 2}){sub 11}-NHCO-coumarin compared to high ratio of 50% HS-(CH{sub 2}){sub 11}-NHCO-coumarin on the surface of gold nanorods.

36 MATERIALS SCIENCE↗

Angle-Resolved Polarized Raman Study of Layered Cr 2 Se 3

The polarization-resolved Raman spectra of two-dimensional Cr 2 Se 3 synthesized via chemical vapor deposition (CVD) and chemical vapor transport (CVT) techniques were investigated in detail. The samples were characterized using X-ray diffraction (XRD), transmission electron microscopy (TEM), and energy-dispersive X-ray spectroscopy (EDS). A distinct polarization dependence was observed in the Raman intensity of all the Cr-Cr, Cr-Se, and Se-Se modes in both samples. The observed angle-dependent Raman intensities of each peak could be related to the crystal structure-specific Raman tensor. XRD results of the bulk Cr 2 Se 3 sample synthesized via CVT confirm its trigonal crystal structure, and the Raman peaks can be fitted using the Raman tensors for the A g and E g modes for both the parallel and crossed polarizations. However, for the Cr 2 Se 3 samples directly grown on Si/SiO 2 substrates by CVD, it was necessary to assume the triclinic crystal structure in order to explain the polarized Raman dependence of all the peaks in both parallel and crossed polarization directions. Furthermore, this is the first experimental result suggesting the existence of triclinic Cr 2 Se 3 crystal structure, which has been theoretically predicted in the Materials Project database.

36 MATERIALS SCIENCE↗

Pulsed laser-induced heating of mineral phases: Implications for laser-induced breakdown spectroscopy combined with Raman spectroscopy

Laser-induced breakdown spectroscopy (LIBS) and Raman spectroscopy are complementary techniques providing respectively chemical and structural information on the sample target. These techniques are increasingly used in Earth and Planetary sciences, and often together. LIBS is locally destructive for the target, and the laser-induced effects due to LIBS laser shots on the structure and on the Raman fingerprint of a set of geological samples relevant to Mars exploration are here investigated by Raman spectroscopy and electron microscopy. Experiments show that the structure of samples with low optical absorption coefficients is preserved as well as the structural information carried by Raman spectra. By contrast, minerals with high optical absorption coefficient can be severely affected by LIBS laser shots with local amorphization, melting and/or phase transformation. Thermal modeling shows that the temperature can reach several thousands of degrees at the surface for such samples during a LIBS laser shot, but decreases rapidly with time and in space. In 2020, NASA Mars 2020 mission will send a rover equipped with a combined LIBS/Raman instrument for remote analysis (SuperCam) as well as proximity science instruments at fine scale for X-ray fluorescence called PIXL for Planetary Instrument for X-ray Lithochemistry, and deep UV Raman spectroscopy called SHERLOC for Scanning Habitable Environments with Raman & Luminescence for Organics & Chemicals. Here, we discuss the implications of our results for the operation of these instruments and show that (i) the SuperCam analytical footprint for Raman spectroscopy is many times larger than the LIBS crater, minimizing any effects and (ii) SHERLOC and PIXL analysis may be affected if they analyze within a LIBS crater created by SuperCam LIBS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Real-Time Automated pH Control within Batch Processes Relying on Raman pH Measurement

Nuclear fission is an energy source that can provide consistent power with very low associated carbon emissions. However, management of the used nuclear fuel is an important aspect of the application of nuclear power. Recycling of useful components from used fuel is an attractive option, but this involves chemical processing of the fuel. Possible chemical separation technologies that might be used in this regard are sensitive to solution pH. Raman spectroscopy is a promising technique for monitoring the pH of solutions in real time. Classical pH probes are too fragile to be used in the harsh environments encountered in nuclear fuel processing. Raman probes are robust and can withstand these harsh environments to track pH. Coupled with chemometric analysis, the demonstration of the use of Raman spectroscopy to track and predict the pH in carboxylate-buffered systems is made possible. Utilizing this spectroscopy in conjunction with Programmable Logic Controllers mimics industrial control systems used in many modern industrial settings. This showcases a pragmatic approach toward leveraging Raman spectroscopy and chemometric model outputs as inputs for a real-time control system. The model to predict pH created by chemometrics proved to be successful in tracking pH. The optimal pH for TALSPEAK extraction of lanthanides and actinides from aqueous solution is known to proceed in a narrow pH range of around pH = 2.8 ± 0.1. This study uses Raman optical monitoring and automated control to return and maintain solution pH within this range after acid or base perturbations move the solution pH well outside this region. Root-mean-square errors show that pH changes measured using Raman spectroscopy on the batch process solution are reliably measured and used to automatically correct and maintain solution pH. Measurement of solution pH tracks favorably with electrochemical pH probe comparison measurements. As a result, the ability to showcase Raman spectroscopy paired with chemometrics analysis acts as a durable, better alternative data source compared to traditional pH probes to optimize the separation efficiency in the used nuclear fuel processing.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evaluating Limits of Machine Learning-Assisted Raman Spectroscopy in Classification of Biological Samples

Machine learning (ML)-assisted Raman spectroscopy has become a powerful analytical tool for the classification and identification of analytes; however, technical challenges impacting its detection accuracy have not been thoroughly investigated. This study explores experimental factors affecting classification performance. Among the evaluated ML models, ML algorithms show minimal impact on classification accuracy. Instead, experimental factors, including spectral similarity between tested samples and data quality, dominate detection performance. Increases in spectral noise and spectral similarity significantly reduce classification accuracy. In well-controlled samples with low experimental noise, ML-assisted Raman spectroscopy can discriminate lipid mixtures with a composition difference of 1.85 mol %. To assess the effect of biological heterogeneity, we analyzed single-cell Raman spectra from Saccharomyces cerevisiae strains carrying single, double, or triple gene mutations. Intrinsic cell-to-cell variability introduced substantial spectral differences, severely reducing the accuracy of multiclass classification of these genetically similar strains at the single-cell level. Averaging Raman spectra across multiple cells improved classification accuracy by reducing this spectral variability. We also assess the effectiveness of transfer learning across different Raman spectrometers, specifically by applying an ML model trained on one instrument to another Raman spectrometer. Transfer learning can be improved with proper instrument calibration, highlighting the importance of instrument standardization. Overall, our results demonstrate that data quality and spectral similarity are the primary bottlenecks in ML-assisted Raman spectroscopy. Careful attention to sample preparation, data acquisition, measurement conditions, and instrument calibration is critical to achieving robust and reliable classification performance.

Fungi↗

Critical Role of Tricyclic Bridges Including Neighboring Rings for Understanding Raman Spectra of Zeolites

Raman spectroscopy of network solids such as zeolites is critical for shedding light on collective vibrations of medium-range structures such as rings that exist in crystals and that form during crystallization processes. Despite this importance, assignments of Raman spectra are not completely understood, though it is often assumed that Raman bands can be assigned to individual rings. We report a systematic zeolite synthesis, spectroscopy, and periodic DFT study of several all-silica zeolites to test this assumption and to determine the fundamental structural motifs that explain Raman spectral features. We have discovered from normal-mode analysis that Raman bands can be assigned to tricyclic bridges: three zeolite rings that share a common Si-O- Si bridge. Additionally, we have found that the vibrational frequency of a given Raman band can be correlated to the smallest ring of its tricyclic bridge and not to the ring that is actually vibrating. Finally, we have discovered a precise anticorrelation between Raman frequency and Si-O-Si angle. These discoveries reflect new ways to investigate structures of network materials made of corner-sharing tetrahedra and to study crystallization from amorphous gels where structural information is limited.

36 MATERIALS SCIENCE↗

From Femtosecond Dynamics to Breast Cancer Diagnosis by Raman Spectroscopy

This paper presents new results based on Raman spectroscopy and demonstrates its utilisation as a diagnostic and development tool with the key advantage in breast cancer research. Applications of Raman spectroscopy in cancer research are in the early stages of development. However, research presented here as well as performed in a few other laboratories demonstrate the ability of Raman spectroscopy to accurately characterize cancer tissue and distinguish between normal, malignant and benign types. The main goals of bio-Raman spectroscopy at this stage are threefold. Firstly, the aim is to develop the diagnostic ability of Raman spectroscopy so it can be implemented in a clinical environment, producing accurate and rapid diagnoses. Secondly, the aim is to optimize the technique as a diagnostic tool for the non-invasive real time medical applications. Thirdly, the aim is to formulate some hypothesis based on Raman spectroscopy on the molecular mechanism which drives the transformation of normal human cells into highly malignant derivatives. To the best of our knowledge, this is the most statistically reliable report on Raman spectroscopy-based diagnosis of breast cancers among the world women population.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Raman cell based on hollow core photonic crystal fiber for human breath analysis

Purpose: Breath analysis has a potential prospect to benefit the medical field based on its perceived advantages to become a point-of-care, easy to use, and cost-effective technology. Early studies done by mass spectrometry show that volatile organic compounds from human breath can represent certain disease states of our bodies, such as lung cancer, and revealed the potential of breath analysis. But mass spectrometry is costly and has slow-turnaround time. The authors’ goal is to develop a more portable and cost effective device based on Raman spectroscopy and hollow core-photonic crystal fiber (HC-PCF) for breath analysis. Methods: Raman scattering is a photon-molecular interaction based on the kinetic modes of an analyte which offers unique fingerprint type signals that allow molecular identification. HC-PCF is a novel light guide which allows light to be confined in a hollow core and it can be filled with a gaseous sample. Raman signals generated by the gaseous sample (i.e., human breath) can be guided and collected effectively for spectral analysis. Results: A Raman-cell based on HC-PCF in the near infrared wavelength range was developed and tested in a single pass forward-scattering mode for different gaseous samples. Raman spectra were obtained successfully from reference gases (hydrogen, oxygen, carbon dioxide gases), ambient air, and a human breath sample. The calculated minimum detectable concentration of this system was ∼15 parts per million by volume, determined by measuring the carbon dioxide concentration in ambient air via the characteristic Raman peaks at 1286 and 1388 cm{sup −1}. Conclusions: The results of this study were compared to a previous study using HC-PCF to trap industrial gases and backward-scatter 514.5 nm light from them. The authors found that the method presented in this paper has an advantage to enhance the signal-to-noise ratio (SNR). This SNR advantage, coupled with the better transmission of HC-PCF in the near-IR than in the visible wavelengths led to an estimated seven times improvement in the detection sensitivity. The authors’ prototype device also demonstrated a 100-fold improvement over a recently reported detection limit of a reflective capillary fiber-based Raman cell for breath analysis. Continued development is underway to increase the detection sensitivity further to reach practical clinical applications.

60 APPLIED LIFE SCIENCES↗

Isotopic Signatures of Lithium Carbonate and Lithium Hydroxide Monohydrate Measured Using Raman Spectroscopy

Lithium isotopic ratios have wide ranging applications as chemical signatures, including improved understanding of geochemical processes and battery development. Measurement of isotope ratios using optical spectroscopies would provide an alternative to traditional mass spectrometric methods, which are expensive and often limited to a chemical laboratory. In this work, Raman spectra of 7 Li 2 CO 3 , 6 Li 2 CO 3 , 7 LiOH*H 2 O and 6 LiOH*H 2 O have been measured to determine the effect of lithium isotope substitution on the Raman molecular vibrations. Thirteen peaks were observed in the spectrum of lithium carbonate, with discernable isotopic shifts occurring in eleven of the thirteen vibrations, two of which have not been previously reported in the literature. The spectrum of lithium hydroxide monohydrate contained nine peaks, with discernable isotopic shifts occurring in eight of the nine vibrations, four of which have not been previously reported in the literature. The Raman spectral data reported here for lithium carbonate and lithium hydroxide monohydrate are in agreement with the previously reported works in the literature, in which the Raman active modes of these molecules were first identified and assigned. However, due to the stability and resolution of the detection system used in this work, isotopic shifts with a magnitude less than one wavenumber have been identified. Principal Component Regression was used to evaluate the sensitivity to isotopic content of small Raman peak shifts in Li 2 CO 3 and indicates differences greater than 2 atom-% could be reliably determined. These measurements add to the body of work on lithium isotope Raman spectroscopy for these two compounds and increases the number of Raman bands which could be used for lithium isotope content analysis.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Characterization of NU-LHT-4M Lunar Regolith Simulant Using Different Raman Configurations

As much as possible, structures to help sustain a long-term human presence on the moon will be constructed via in-situ resource utilization (ISRU) from lunar regolith. Various processes have been proposed to make lunar regolith-based construction materials, but one complication is that the lunar regolith is relatively complex in terms of composition and can vary quite significantly from one site to another. Some of these methods to make lunar regolith-based construction materials are quite sensitive to the composition and so in-situ methods for evaluating the composition of the lunar regolith could be critical. Various analytical instrumentation has been proposed for in-situ characterization of the composition of regolith on planetary bodies. Raman spectroscopy has been suggested and has some advantages over other in-situ techniques, such as potential for relatively high spatial resolution, direct determination of the mineralogy (while other methods may only infer the mineralogy), nondestructive analysis, relatively simple instrument configurations, and minimal sample preparation/handling. For example, Raman instrumentation has already been deployed in rover-based missions to Mars. Previously, we developed the Standoff Ultracompact Micro-Raman Sensor (SUCR), which is a portable Raman spectroscopy instrument capable to be integrated into a rover or onto a lander. Here, we present work on Raman spectroscopy measurements of NU-LHT-4M lunar simulant using three different Raman instruments with different configurations for collecting Raman data with the goal to explore the effect of these different configurations on the results, especially for use in a lunar environment.

Raman Spectroscopy↗

High pressure Raman scattering study on the phase stability of LuVO{sub 4}

High pressure Raman spectroscopic investigations have been carried out on rare earth orthovanadate LuVO{sub 4} upto 26 GPa. Changes in the Raman spectrum around 8 GPa across the reported zircon to scheelite transition are investigated in detail and compared with those observed in other vanadates. Co-existence of the zircon and scheelite phases is observed over a pressure range of about 8-13 GPa. The zircon to scheelite transition is irreversible upon pressure release. Subtle changes are observed in the Raman spectrum above 16 GPa which could be related to scheelite reversible fergusonite transition. Pressure dependencies of the Raman active modes in the zircon and the scheelite phases are reported. - Graphical abstract: Study of scheelite-fergusonite transition in RVO{sub 4} by Raman spectroscopy is rare. Here we report Raman spectroscopic investigations of LuVO{sub 4} at high pressure to obtain insight into nature of post-scheelite phases.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Structure and vibrational modes of AgI-doped AsSe glasses: Raman scattering and ab initio calculations

We report an investigation of the structure and vibrational modes of (AgI){sub x} (AsSe){sub 100-x}, bulk glasses using Raman spectroscopy and first principles calculations. The short- and medium-range structural order of the glasses was elucidated by analyzing the reduced Raman spectra, recorded at off-resonance conditions. Three distinct local environments were revealed for the AsSe glass including stoichiometric-like and As-rich network sub-structures, and cage-like molecules (As{sub 4}Se{sub n}, n=3, 4) decoupled from the network. To facilitate the interpretation of the Raman spectra ab initio calculations are employed to study the geometric and vibrational properties of As{sub 4}Se{sub n} molecular units that are parts of the glass structure. The incorporation of AgI causes appreciable structural changes into the glass structure. AgI is responsible for the population reduction of molecular units and for the degradation of the As-rich network-like sub-structure via the introduction of As-I terminal bonds. Ab initio calculations of mixed chalcohalide pyramids AsSe{sub m}I{sub 3-m} provided useful information augmenting the interpretation of the Raman spectra. -- Graphical abstract: Raman scattering and ab initio calculations are employed to study the structure of AgI-AsSe superionic glasses. The role of mixed chalcohalide pyramidal units as illustrated in the figure is elucidated. Display Omitted Research highlights: {yields} Doping binary As-Se glasses with AgI cause dramatic changes in glass structure. {yields} Raman scattering and ab initio calculations determine changes in short- and medium-range order. {yields} Three local environments exist in AsSe glass including a network sub-structure and cage-like molecules. {yields} Mixed chalcohalide pyramids AsSe{sub m}I{sub 3-m} dominate the AgI-doped glass structure.

36 MATERIALS SCIENCE↗

Synchrotron X-ray diffraction and Raman spectroscopy of Ln{sub 3}NbO{sub 7} (Ln=La, Pr, Nd, Sm-Lu) ceramics obtained by molten-salt synthesis

Ln{sub 3}NbO{sub 7} (Ln=La, Pr, Nd, Sm, Eu, Gd, Tb, Dy, Ho, Er, Tm, Yb, and Lu) ceramics were obtained by molten-salt synthesis and their structures were systematically investigated by synchrotron X-ray diffraction (SXRD), second harmonic generation (SHG) and Raman spectroscopy. It was observed that ceramics with the largest ionic radii (La, Pr, Nd) crystallized into the Pmcn space group, while the ceramics with intermediate ionic radii (Sm-Gd) exhibited a different crystal structure belonging to the Ccmm space group. For this last group of ceramics, this result was corroborated by SHG and Raman scattering and ruled out any possibility for the non-centrosymmetric C 222{sub 1} space group, solving a recent controversy in the literature. Finally, according to SXRD, Tb-Lu containing samples exhibited an average defect fluorite structure (Fm3{sup ¯}m space group). Nonetheless, broad scattering at forbidden Bragg reflections indicates the presence of short-range domains with lower symmetry. Vibrational spectroscopy showed the presence of six Raman-active modes, inconsistent with the average cubic fluorite structure, and in line with the existence of lower-symmetry nano-domains immersed in the average fluorite structure of these ceramics. - Graphical abstract: Raman spectrum for Sm{sub 3}NbO{sub 7} ceramics showing their 27 phonon modes adjusted through Lorentzian lines. According to synchrotron X-ray diffraction and Raman scattering, this material belongs to the space group Cmcm. Display Omitted - Highlights: • Ln{sub 3}NbO{sub 7} ceramics were obtained by molten-salt synthesis. • SXRD, SHG and Raman scattering confirmed orthorhombic and cubic structures. • Ccmm instead of C222{sub 1} is the correct structure for Sm–Gd ceramics. • Pmcn space group was confirmed for La-, Pr- and Nd-based ceramics. • For Tb–Lu ceramics, ordered domains of a pyrochlore structure were observed.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Synthesis and in situ high pressure Raman spectroscopy study of AlN dendritic crystal

Graphical abstract: - Highlights: • The sample is the typical dendritic crystal structure. • The phase transition of AlN dendritic crystal is researched. • The Raman signal of rock salt AlN is observed under high pressure. • Grüneisen parameters and phase transition criterion are discussed. - Abstract: AlN dendritic crystal was synthesized by the direct current arc discharge apparatus. X-ray diffraction (XRD) patterns indicated that the sample is hexagonal AlN and preferentially grown along the a-axis direction. Scanning electron microscopy (SEM) and Transmission electron microscopy (TEM) images reveal that the product mainly consists of micron AlN dendritic crystal. In situ high pressure Raman spectra of AlN dendritic crystal has been measured in the pressure ranged from ambient pressure to 32.97 GPa at room temperature by using diamond anvil cell. According to the Raman scattering results, the phase transition from the wurtzite to rock salt was found at about 20.73 GPa by the appearance of a new Raman signal. Above 20.73 GPa, a new Raman signal due to disorder-activated Raman scattering in the rock salt phase was observed. In addition, the pressure coefficients, phase transition criterion, and mode Grüneisen parameters of AlN dendritic crystal, which could be different from that of other AlN, are carefully discussed.

36 MATERIALS SCIENCE↗

Nanocavity-Enhanced Giant Stimulated Raman Scattering in Si Nanowires in the Visible Light Region

Silicon photonics has been a very active area of research especially in the past two decades in order to meet the ever-increasing demand for more computational power and faster device speeds and their natural compatibility with complementary metal-oxide semiconductor. In order to develop Si as a useful photonics material, essential photonic components such as light sources, waveguides, wavelength convertors, modulators, and detectors need to be developed and integrated. However, due to the indirect electronic bandgap of Si, conventional light emission devices such as light-emitting diodes and lasers cannot be built. Therefore, there has been considerable interest in developing Si-based Raman lasers, which are nonlinear devices and require large stimulated Raman scattering (SRS) in an optical cavity. However, due to the low quantum yield of SRS in Si, Raman lasers have very large device footprints and high lasing threshold, making them unsuitable for faster, smaller, and energy-efficient devices. Here in this paper, we report strong SRS and extremely high Raman gain in Si nanowire optical cavities in the visible region with measured SRS threshold as low as 30 kW/cm 2 . At cavity mode resonance, light is confined into a low mode volume and high intensity electromagnetic mode inside the Si nanowire due to its high refractive index, which leads to strong SRS at low pump intensities. Electromagnetic calculations reveal greater than 6 orders of magnitude increase in Raman gain coefficient at 532 nm pump wavelength, compared to the gain value at 1.55 μm wavelength reported in literature, despite the 10 8 higher losses at 532 nm. Because of the high gain in such small structures, we believe that this is a significant first step in realizing a monolithically integrable nanoscale low-powered Si Raman laser.

36 MATERIALS SCIENCE↗

Time-domain self-broadened and air-broadened nitrogen S-branch Raman linewidths at 80–200 K recorded in an underexpanded jet

We report pure-rotational N 2 –N 2 , N 2 –air, and O 2 –air S-branch linewidths for temperatures of 80–200 K by measuring the time-dependent decay of rotational Raman coherences in an isentropic free-jet expansion from a sonic nozzle. We recorded pure-rotational hybrid femtosecond/picosecond coherent anti-Stokes Raman scattering (fs/ps CARS) spectra along the axial centerline of the underexpanded jet, within the barrel shock region upstream of the Mach disk. The dephasing of the pure-rotational Raman coherence was monitored using probe-time-delay scans at different axial positions in the jet, corresponding to varying local temperatures and pressures. The local temperature was obtained by fitting CARS spectra acquired at zero probe time delay, where the impact of collisions was minimal. The measured decay of each available Raman transition was fit to a dephasing constant and corrected for the local pressure, which was obtained from the CARS-measured static temperature and thermodynamic relationships for isentropic expansion from the known stagnation state. Nitrogen self-broadened transitions decayed more rapidly than those broadened in air for all temperatures, corresponding to higher Raman linewidths. In general, the measured S-branch linewidths deviated significantly in absolute and relative magnitudes from those predicted by extrapolating the modified exponential gap model to low temperatures. The temperature dependence of the Raman linewidth for each measured rotational state of nitrogen (J ≤ 10) and oxygen (N ≤ 11) was fit to a temperature-dependent power law over the measurable temperature domain (80–200 K) and extrapolated to both higher rotational states and room temperature. Furthermore, the measured and modeled low-temperature linewidth data provided here will aid low temperature gas-phase pressure measurements with fs/ps CARS.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Extracting interface locations in multilayer polymer waveguide films using scanning angle Raman spectroscopy

There is an increasing demand for nondestructive in situ techniques that measure chemical content, total thickness, and interface locations for multilayer polymer films, and SA Raman spectroscopy in combination with appropriate data models can provide this information. A scanning angle (SA) Raman spectroscopy method was developed to measure the chemical composition of multilayer polymer waveguide films and to extract the location of buried interfaces between polymer layers with 7–80-nm axial spatial resolution. The SA Raman method measures Raman spectra as the incident angle of light upon a prism-coupled thin film is scanned. Six multilayer films consisting of poly(methyl methacrylate)/polystyrene or poly(methyl methacrylate)/polystyrene/poly(methyl methacrylate) were prepared with total thicknesses ranging from 330-1260 nm. The interface locations were varied by altering the individual layer thicknesses between 140-680 nm. The Raman amplitude ratio of the 1605 cm -1 peak for PS and 812 cm -1 peak for PMMA was used in calculations of the electric field intensity within the polymer layers to model the SA Raman data and extract the total thickness and interface locations. There is an average 8% and 7% difference in the measured thickness between the SA Raman and profilometry measurements for bilayer and trilayer films, respectively.

36 MATERIALS SCIENCE↗

Raman chemical imaging of the rhizosphere bacterium Pantoea sp. YR343 and its co-culture with Arabidopsis thaliana

Chemical imaging of plant-bacteria co-cultures renders it possible to characterize bacterial populations and behaviors and their interactions with proximal organisms, under conditions closest to the environment in the rhizosphere. Here Raman micro-spectroscopy and confocal Raman imaging are used as minimally invasive probes to study the rhizosphere bacterial isolate, Pantoea sp. YR343, and its co-culture with model plant Arabidopsis thaliana by combining enhanced Raman spectroscopies with electron microscopy and principal component analysis (PCA). In this work, the presence of carotenoid pigments in the wild type Pantoea sp. YR343 was characterized using resonance Raman scattering, which was also used to confirm successful disruption of the crtB gene in an engineered carotenoid mutant strain. Other components of the Pantoea sp. YR343 cells were imaged in the presence of resonantly enhanced pigments using a combination of surface enhanced Raman imaging and PCA. Pantoea sp. YR343 cells decorated with Ag colloid synthesized ex situ gave spectra dominated by carotenoid scattering, whereas colloids synthesized in situ produced spectral signatures characteristic of flavins in the cell membrane. Scanning electron microscopy (SEM) of whole cells and transmission electron microscopy (TEM) images of thinly sliced cross-sections were used to assess structural integrity of the coated cells and to establish the origin of spectral signatures based on the position of Ag nanoparticles in the cells. Finally, raman imaging was also used to characterize senescent green Arabidopsis thaliana plant roots inoculated with Pantoea sp. YR343, and PCA was used to distinguish spectral contributions from plant and bacterial cells, thereby establishing the potential of Raman imaging to visualize the distribution of rhizobacteria on plant roots.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗