Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Radiation detectors”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

System and method for passive assay of holdup deposits in nuclear piping

Disclosed herein are a method, apparatus, and software for passive, non-destructive assay of holdup deposits in nuclear piping by in-pipe apparatus. A detector deployed within a pipe is collimated to observe radiation impinging radially inward from decay of deposits that lie on the pipe wall. A radiation detector is centered in the pipe and collimated by a pair of coaxial shielding discs disposed equidistant from the detector. This arrangement causes radiation from a truncated cylinder of pipe deposit within a field of regard to impinge on the detector, while precluding radiation emanating from pipe walls beyond the field of regard from reaching the detector. Hence, observations are unique to a known cylindrical length of pipe. The detector assembly is translated through pipes by an autonomous mobile robotic apparatus. Computer software controls the robotic apparatus, logs data, and post-processes to assay deposits.

Whittaker, William Lawrence↗

Trapped radiation experiment

Trapped radiation detector on Mariner IV space probe measurement of outer Van Allen belt - feasibility of detecting trapped radiation at Mars

MARINER IV SPACE PROBE↗

Space radiation studies

Instrument design and data analysis expertise was provided in support of several space radiation monitoring programs. The Verification of Flight Instrumentation (VFI) program at NASA included both the Active Radiation Detector (ARD) and the Nuclear Radiation Monitor (NRM). Design, partial fabrication, calibration and partial data analysis capability to the ARD program was provided, as well as detector head design and fabrication, software development and partial data analysis capability to the NRM program. The ARD flew on Spacelab-1 in 1983, performed flawlessly and was returned to MSFC after flight with unchanged calibration factors. The NRM, flown on Spacelab-2 in 1985, also performed without fault, not only recording the ambient gamma ray background on the Spacelab, but also recording radiation events of astrophysical significance.

Gregory, J. C.↗

A Satellite Borne Cadmium Sulfide Total Corpuscular Energy Detector

The properties of single crystals of cadmium sulfide as radiation detectors are described. It has been found possible to select crystals such that: (a) The ratio of increase of conductivity under irradiation to the rate of absorption of energy in the crystal is substantially independent of particle energy (over the examined ranges of 500 ev to 80 kev for electrons and 5 kev to 180 kev for protons) and of the magnitude of energy flux (over the range from.005 to 10 ergs/cm(sup 2 -sec); and (b) The above ration is substantially the same for protons, electrons, alpha particles, x-rays, and gamma-rays. For a driving voltage of 100 volts, typical crystal yield currents of 10(sup -7) to 10(sup- 6) amperes for each erg/cm(sup 2-sec) of energy absorbed by the crystal. The threshold of such crystal detectors (resulting from dark currents of the order of 10(sup 10 amp) is typically 10(sup -3) ergs/cm(sup 2- sec). For the selected crystals a response-temperature coefficient of -0.25% per degree centigrade is found for the temperature range -50 deg C to + 50 deg C. A description is given of a complete CdS total corpuscular energy detector for the study of geomagnetically trapped radiation by means of a satellite. The detector described has a dynamic range great than 10(sup 4), a solid angle of 10(exp -3) steradian, and a detection threshold of approximately 1 erg/cm(sup 2-sec-sterad). A similar detector employing a small magnet for the selective exclusion of electrons is also described. Noteworthy practical features of these detectors for satellite and space probe experiments are: (a) Use of bare crystals, without covering foils, in order to detect charged particles having energies as low as hundreds of electron volts. (b) Simplicity of electronic auxiliaries. (c) Compactness, lightweight and nechanical ruggedness. (d) Low electrical power requirements; and (e) Conversion of conduction current to the rate of a twostate relaxation oscillator in order to facilitate telemetric transmission of data. A pair of such detectors was flown as part of the s-46 satellite payload on March 23, 1960, but due to vehicular failure an orbit was not achieved and the operation of the CdS detectors was observed for only, six minutes of flight.

Freeman, John W.↗

Detector absorptivity measuring method and apparatus

A method and apparatus for measuring the absorptivity of a radiation detector by making the detector an integral part of a cavity radiometer are described. By substituting the detector for the surface of the cavity upon which the radiation first impinges a comparison is made between the quantity of radiation incident upon the detector and the quantity reflected from the detector. The difference between the two is a measurement of the amount of radiation absorbed by the detector.

Sheets, R. E.↗

A sensitive and robust thin-film x-ray detector using 2D layered perovskite diodes

Solid-state radiation detectors, using crystalline semiconductors to convert radiation photons to electrical charges, outperform other technologies with high detectivity and sensitivity. Here, we demonstrate a thin-film x-ray detector comprised with highly crystalline two-dimensional Ruddlesden-Popper phase layered perovskites fabricated in a fully depleted p-i-n architecture. It shows high diode resistivity of 10 12 ohm·cm in reverse-bias regime leading to a high x-ray detecting sensitivity up to 0.276 C Gy air –1 cm –3 . Such high signal is collected by the built-in potential underpinning operation of primary photocurrent device with robust operation. The detectors generate substantial x-ray photon–induced open-circuit voltages that offer an alternative detecting mechanism. Furthermore, our findings suggest a new generation of x-ray detectors based on low-cost layered perovskite thin films for future x-ray imaging technologies.

47 OTHER INSTRUMENTATION↗

Effects of natural zeolites on field-scale geologic noble gas transport

Improving predictive models for noble gas transport through natural materials at the field-scale is an essential component of improving US nuclear monitoring capabilities. Several field-scale experiments with a gas transport component have been conducted at the Nevada National Security Site (Non-Proliferation Experiment, Underground Nuclear Explosion Signatures Experiment). However, the models associated with these experiments have not treated zeolite minerals as gas adsorbing phases. This is significant as zeolites are a common alteration mineral with a high abundance at these field sites and are shown here to significantly fractionate noble gases during field-scale transport. This fractionation and associated retardation can complicate gas transport predictions by reducing the signal-to-noise ratio to the detector (e.g. mass spectrometers or radiation detectors) enough to mask the signal or make the data difficult to interpret. Omitting adsorption-related retardation data of noble gases in predictive gas transport models therefore results in systematic errors in model predictions where zeolites are present.Herein is presented noble gas adsorption data collected on zeolitized and non-zeolitized tuff. Experimental results were obtained using a unique piezometric adsorption system designed and built for this study. Data collected were then related to pure-phase mineral analyses conducted on clinoptilolite, mordenite, and quartz. These results quantify the adsorption capacity of materials present in field-scale systems, enabling the modeling of low-permeability rocks as significant sorption reservoirs vital to bulk transport predictions.

58 GEOSCIENCES↗

Tl+-based and mixed halide A3B2X9-type scintillators

Inorganic halides (e.g., inorganic halide scintillators) of the general formula A3B2X9, including inorganic halides comprising thallium monovalent cations and/or combinations of different halides, are described. Radiation detectors including the inorganic halide scintillators and methods of using the detectors to detect high energy radiation are also described. In some cases, the scintillators can include a gadolinium cation, a boron cation, a lithium cation, a chloride ion, or combinations thereof and the scintillator can be used to detect neutrons.

Rutstrom, Daniel↗

Radiation monitoring devices and associated methods

Radiation monitoring devices and associated methods are described. According to one aspect, a radiation monitoring device includes a housing configured to pass radiation emitted from a radiological source located in proximity to the radiation monitoring device, a radiation detector configured to receive the radiation emitted from the radiological source and to generate information regarding the radiation, and communications circuitry configured to communicate the information regarding the radiation in a plurality of communications at a plurality of different moments in time externally of the radiation monitoring device.

Burghard, Brion J.↗

Cadmium Magnesium Telluride for Next-Generation X-Ray Free Electron Laser, Synchrotron, and Many Other Applications

We developed a picosecond photodetector based on our Bridgman-grown and specially engineered cadmium magnesium telluride (Cd 1–x MgxTe) single crystal that is sensitive to both optical and X-ray pulses for coarse timing in free-electron laser applications. Cd 1–x MgxTe is a widebandgap semiconductor with potential applications, not only in optoelectronics, but also in particle physics as an intense pulse radiation detector for bremsstrahlung, X-ray/gamma-ray radiation, thermal neutrons, and medical imaging. For femtosecond optical and X-ray crosscorrelation, the material must have a very short lifetime, a condition that is opposite to that required for nuclear spectroscopy applications. At the same time, the material also needs to have a very low bulk leakage current, in the 10–90 nA range for voltages to even 1000 V. Hence, the ability to tailor or engineer the material is very crucial. Picosecond response and the crystal growth of this specially engineered Cd 1–x MgxTe material are presented. Furthermore, other characterization and transient measurements are discussed along with room-temperature semiconductor detector performance for other nuclear radiation detection applications.

36 MATERIALS SCIENCE↗

SiC Charged Particle Telescope GRC Independent Research and Development (IRAD) Program End of Project Final Report

In an advancement over the state-of-the art, NASA Glenn Research Center (GRC) has developed a large area silicon carbide (SiC)-based charged particle telescope through an Independent Research and Development (IRAD) project. The telescope has been demonstrated to have improved noise characteristics and resolution than previous SiC detectors. This improvement will meet the challenges of compact multidirectional robust radiation detector systems to study a wide range of elementary particle mass and energies. In order to provide a complete understanding of how energetic processes internal and external to the solar system shape magnetospheres, atmospheres, and surfaces, in situ particle observations should include measurements of Solar Energetic Particles (SEP) and Galactic Cosmic Rays (GCR), along with solar wind and plasma. The potential temperature stability, tolerance to high radiation environments, and low noise characteristics expected in SiC-based detectors can have advantages over the state-of-the-art silicon detectors. These advantages will allow the detectors to be deployed in small compact systems on a variety of platforms, enabling compact structures for small satellite platforms with improved data quality.

Field and particle detectors↗

Characterization of CdZnTeSe Nuclear Detector Chemically Etched in Bromine Methanol

Semiconductor nuclear radiation detectors made from tertiary and quaternary compounds of cadmium telluride (CdTe) can operate at room temperature without cryogenic cooling. One of such materials that have become of great interest is cadmium zinc telluride selenide (CdZnTeSe). Compared to other CdTe-based materials, such as cadmium zinc telluride (CdZnTe), CdZnTeSe can be grown with much less Te inclusions and sub-grain boundary networks. Chemical etching is often used to smoothen wafer surfaces during detector fabrication. This paper presents the characterization of CdZnTeSe that is chemically etched using bromine methanol solution. Infrared imaging shows that the wafer has no sub-grain boundary networks that often limit detector performance. The current-voltage (I-V) characterization experiment gave a resistivity of 4.6 × 10 10 Ω-cm for the sample. The I-V curve was linear in the ±10 to ±50 volts range. An energy resolution of 7.2% was recorded at 100 V for the 59.6-keV gamma line of 241 Am.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗