The Role of Marangoni Convection for the FZ-Growth of Silicon

Fluctuations of the electrical resistivity due to inhomogeneous dopant distribution are still a serious problem for the industrial processing yield of doped silicon crystals. In the case of silicon floating-zone growth, the main sources of these inhomogeneities are time- dependent flows in the liquid phase during the growth process. Excluding radio frequency (RF) induced convection, buoyancy and thermocapillary (Marangoni) convection are the two natural reasons for fluid flow. Both originate from temperature/concentration gradients in the melt, buoyancy convection through thermal/concentrational volume expansion, and thermocapillary convection through the temperature/concentration dependence of the surface tension. To improve the properties of grown crystals, knowledge of the strength, the characteristic, and the relation of these two flow mechanisms is essential. By the use of microgravity, the effect and the strength of buoyancy (gravity dependent) and thermocapillary (gravity independent) convection can be separated and clarified. Applying magnetic fields, both convective modes can be influenced: fluid flow can either be damped (static magnetic fields) or overlaid by a regular flow regime (rotating magnetic fields). Two complementary approaches have been pursued: Silicon full zones (experiments on the German sounding rockets TEXUS 7, 12, 22, 29, and 36) with the maximum temperature at half of the zone height and silicon half zones (experiments on the Japanese sounding rockets TR-IA4 and 6) with the maximum temperature at the top of the melt. With the full zone arrangement, the intensity and the frequency of the dopant striations could be determined and the critical Marangoni number could be identified. The half zone configuration is suited to classify the flow pattern and to measure the amplitude and the frequency of temperature fluctuations in the melt by inserting thermocouples or temperature sensors into the melt. All experiments have been carried out in monoellipsoid mirror furnaces. Typical zone geometries are approx. 8 to 14 mm in diameter and height. The crystals grown under microgravity are compared to crystals grown in static axial magnetic fields (B<5 tesla) and in transversal rotating magnetic fields (B<7.5 mT / f=50 Hz). Experimental results are completed by 3D numerical simulations: the obtained temperature and concentration distribution in the melt confirm the damping effect of rotating magnetic fields and explain the change in the radial segregation under static magnetic fields.

Dold, P.↗

Aberration corrected RF flipper for high resolution neutron spectroscopy

Project Summary Company: Adelphi Technology, Inc. Title: Aberration-corrected High Frequency RF Flipper for High-Resolution Neutron Spectroscopy PI: Dr. Jay Theodore Cremer Topic: C55-11 Enhancement of Scattering Instrumentation Technology Used at Pulsed and Continuous Sources Subtopic: d. Other Statement of the problem or situation that is being addressed. The quest to understand heterogeneous and hierarchical materials is gathering momentum, as described in a 2015 report by the Basic Energy Sciences Advisory Committee on Challenges at the Frontiers of Matter and Energy. For the past 40 years a technique called neutron spin echo (NSE) has been used to probe molecular motions in such non-crystalline materials over time scales from 10’s of picoseconds to 100’s of nanoseconds. The method has provided unique information about the dynamics of soft heterogeneous materials, including confirmation of the de Gennes model of polymer reptation and quantitative measurement of bending constants of biologically relevant lipid membranes. However, scientists continue to clamor for even higher resolution than NSE can provide. Biomaterials, polymers, glasses, and artificially nanostructured materials all manifest slow molecular motions because of weak or competing interactions between subunits and are amenable to study with neutrons, provided sufficiently long dynamical correlation times can be achieved. All these materials have important applications to advanced technologies so understanding them is key to technological progress. General statement of how this problem is being addressed. We will address the need for high-resolution neutron spectroscopy by using a technique called Neutron Resonance Spin Echo (NRSE). While similar to NSE in many respects, this method has the potential to exceed the NSE capabilities, if 2 technical hurdles can be overcome. The major impediments to successful high-resolution NRSE are the availability of two technologies: a very high frequency, efficient, radiofrequency (rf) flipper for neutrons and a method to correct certain magnetic aberrations. Based on previous STTR support and follow-on research we have developed a suitable rf flipper and we have invented a method to correct the magnetic aberrations. Both technologies need refinement to make them suitable for implementation at a neutron source such as the Oak Ridge National Laboratory nuclear reactor. In this proposal we seek to perfect the two technologies and to combine them into a single, operationally convenient device. Commercial Applications and Other Benefits In view of the increasing demand for the unique scientific information that high resolution neutron spectroscopy can provide, we expect several major instrumentation upgrades at both U.S. and foreign neutron centers will require make use of the NRSE method over the coming decade, creating a market for the devices we will design. These components will enhance scientists’ abilities to probe the time dependence of density fluctuations in a wide range of hierarchical and heterogeneous materials many of which are vital to existing and future technologies. Key Words – Polarized Neutrons, Neutron Spin Echo, Neutron Scattering, advanced materials. Summary for Members of Congress Neutron beams are a powerful materials-science probe that provide unique information about the structure of matter. The proposed devices will accelerate scientific discoveries required to achieve national goals for new technological materials.

36 MATERIALS SCIENCE↗

Fully Printed High-Frequency Phased-Array Antenna on Flexible Substrate

To address the issues of flexible electronics needed for surface-to-surface, surface-to-orbit, and back-to-Earth communications necessary for manned exploration of the Moon, Mars, and beyond, a room-temperature printing process has been developed to create active, phased-array antennas (PAAs) on a flexible Kapton substrate. Field effect transistors (FETs) based on carbon nanotubes (CNTs), with many unique physical properties, were successfully proven feasible for phased-array antenna systems. The carrier mobility of an individual CNT is estimated to be at least 100,000 sq cm/V(dot)s. The CNT network in solution has carrier mobility as high as 46,770 sq cm/V(dot)s, and has a large current-density carrying capacity of approx. 1,000 mA/sq cm , which corresponds to a high carrying power of over 2,000 mW/ sq cm. Such high carrier mobility, and large current carrying capacity, allows the achievement of high-speed (>100 GHz), high-power, flexible electronic circuits that can be monolithically integrated on NASA s active phasedarray antennas for various applications, such as pressurized rovers, pressurized habitats, and spacesuits, as well as for locating beacon towers for lunar surface navigation, which will likely be performed at S-band and attached to a mobile astronaut. A fully printed 2-bit 2-element phasedarray antenna (PAA) working at 5.6 GHz, incorporating the CNT FETs as phase shifters, is demonstrated. The PAA is printed out at room temperature on 100-mm thick Kapton substrate. Four CNT FETs are printed together with microstrip time delay lines to function as a 2-bit phase shifter. The FET switch exhibits a switching speed of 0.2 ns, and works well for a 5.6-GHz RF signal. The operating frequency is measured to be 5.6 GHz, versus the state-of-the-art flexible FET operating frequency of 52 MHz. The source-drain current density is measured to be over 1,000 mA/sq cm, while the conventional organic FETs, and single carbon nanotube-based FETs, are typically in the mA to mA/sq cm range. The switching voltage used is 1.8 V, while the state-of-the-art flexible FET has a gate voltage around 50 V. The gate voltage can effectively control the source-drain current with an ON-OFF ratio of over 1,000 obtained at a low Vds bias of 1.8 V. The azimuth steering angles of PAA are measured at 0deg, -14.5deg, -30deg, and 48.6deg. The measured far-field patterns agree well with simulation results. The efficiency of the 2-bit 2-element PAA is measured to be 39 percent, including the loss of transmission line, FET switch, and coupling loss of RF probes. With further optimization, the efficiency is expected to be around 50-60 percent.

Chen, Yihong↗

Photon Frequency Conversion in High-Q Superconducting Resonators: Axion Electrodynamics, QED, and Nonlinear Meissner Radiation

High-Q superconducting resonators have been proposed and developed as detectors of light-by-light scattering mediated by the hypothesized axion or virtual electron–positron pairs in quantum electrodynamics: the Euler–Heisenberg (EH) interaction. Photon frequency and mode conversion is central to the scheme for detecting such rare events. Superconducting resonators are nonlinear devices. The Meissner screening currents that confine the electromagnetic fields to the vacuum region of a superconducting RF cavity are nonlinear functions of the EM field at the vacuum–superconducting interface, and as a result can generate source currents and frequency conversion of microwave photons in the cavity. In this report we consider photon frequency and mode conversion in superconducting resonators with high quality factors from Meissner currents in single- and dual-cavity setups proposed for axion and QED searches based on light-by-light scattering. In a single cavity with two pump modes, photon frequency conversion by the Meissner screening current dominates photon generation by the EH interaction for cavities with Q≲1012⁠. The Meissner currents also generate background photons that limit the operation of the resonator for axion detection in three-mode, single-cavity setups. We also consider the leakage of photons from pump modes into the signal mode for both axion- and EH-mediated light-by-light scattering. Photon frequency conversion by the EH interaction can compete with Meissner and leakage radiation in ultra-high-Q cavities that are beyond the current state of the art. Meissner radiation and leakage backgrounds can be suppressed in dual-cavity setups with appropriate choices for pump and spectator modes, as well as the single-cavity setup proposed for heterodyne detection of galactic axion dark matter.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Precise Phase Comparator for Nearly Equal Frequencies

New circuit precisely compares phases of two RF signals nearly equal in frequency, such as two hydrogen-maser frequency standards. Measuring circuit minimizes interactions between two sources. Also stabilized against thermal effects and against noise that could produce erroneous readings. Heat sinking, buffer amplifiers, and low-noise zero-crossing detector make picosecond precision possible.

Reinhardt, V. S.↗

Enabling the Next Generation of Smart Sensors in Coal Fired Power Plants using Cellular 5G Technology

An important need for coal fired power plants is the ability to monitor multiple systems with ease and accuracy. Common implementations of these monitoring systems come with drawbacks due to the nature of coal fired power plants. Harsh environments, High Temperatures, and lots of RF (Radio Frequency) noise can create issues for accurately recording and transmitting data across wireless signals. In addition, as renewable energy sources come online, existing fossil fueled plants will need to operate more flexibly with their maintenance schedules outside of standard conditions. Therefore, additional sensing and control mechanisms need placed in existing plants to provide operators with more information such that maintenance decisions can be made well in advance of failures. A solution to this problem is the Next Generation of Smart Sensors, which leverages the power of 5G cellular signals and machine learning to overcome the myriad of problems with current implementations

20 FOSSIL-FUELED POWER PLANTS↗

Active cleaning technique device

The objective of this program was to develop a laboratory demonstration model of an active cleaning technique (ACT) device. The principle of this device is based primarily on the technique for removing contaminants from optical surfaces. This active cleaning technique involves exposing contaminated surfaces to a plasma containing atomic oxygen or combinations of other reactive gases. The ACT device laboratory demonstration model incorporates, in addition to plasma cleaning, the means to operate the device as an ion source for sputtering experiments. The overall ACT device includes a plasma generation tube, an ion accelerator, a gas supply system, a RF power supply and a high voltage dc power supply.

Shannon, R. L.↗

Development and evaluation of a set of group delay standards

A set of cable assemblies serving as group delay standards having nominal delays of 15, 30, and 60 nsec are described. Various types of measurements were performed on the cable standards, including impedance, microwave phase shift, RF pulse burst delay, modulation pulsed delay, and envelope phase shift measurements. The results of these tests are given, and various sources of error are discussed, in particular, dispersion and internal reflections.

Otoshi, T. Y.↗

Hollow cathode startup using a microplasma discharge

Attention is given to a microplasma discharge to initiate a hollow cathode discharge for such applications as plasma flow experiments, the electric propulsion of space vehicles, and as a replacement for filament cathodes in neutral beam injector ion sources. The technique results in a cathode that is easy to start, simple in design, and which does not require external RF exciters, inserts or heating elements. Future applications may include ion beam milling and ion implantation.

Aston, G.↗

Ultrasensitive detection of atmospheric trace gases using frequency modulation spectroscopy

Frequency modulation (FM) spectroscopy is a new technique that promises to significantly extend the state-of-the-art in point detection of atmospheric trace gases. FM spectroscopy is essentially a balanced bridge optical heterodyne approach in which a small optical absorption or dispersion from an atomic or molecular species of interest generates an easily detected radio frequency (RF) signal. This signal can be monitored using standard RF signal processing techniques and is, in principle, limited only by the shot noise generated in the photodetector by the laser source employed. The use of very high modulation frequencies which exceed the spectral width of the probed absorption line distinguishes this technique from the well-known derivative spectroscopy which makes use of low (kHz) modulation frequencies. FM spectroscopy was recently extended to the 10 micron infrared (IR) spectral region where numerous polyatomic molecules exhibit characteristic vibrational-rotational bands. In conjunction with tunable semiconductor diode lasers, the quantum-noise-limited sensitivity of the technique should allow for the detection of absorptions as small as .00000001 in the IR spectral region. This sensitivity would allow for the detection of H2O2 at concentrations as low as 1 pptv with an integration time of 10 seconds.

Cooper, David E.↗

Validation of Spectral Analysis as a Noninvasive Tool to Assess Autonomic Regulation of Cardiovascular Function

A major focus of our program has been to develop a sensitive noninvasive procedure to quantify early weightlessness-induced changes in cardiovascular function or potential dysfunction. Forty studies of healthy young volunteers (10 men and 10 women, each studied twice) were conducted to determine changes in the sympatho-vagal balance of autonomic control of cardiovascular regulation during graded headward and footward blood volume shifts. Changes in sympatho-vagal balance were classified by changes in the mean levels and spectral content of cardiovascular variables and verified by changes in circulating levels of catecholamines and pancreatic polypeptide. Possible shifts in intra/extravascular fluid were assessed from changes in hematocrit and plasma mass density while changes in the stimulus to regulate plasma volume were determined from Plasma Renin Activity (PRA). Autonomic blockade was used to unmask the relative contribution of sympathetic and parasympathetic efferent influences in response to 10 min each of 0, 20 and 40 mmHg Lower Body Negative Pressure (LBNP) and 15 and 30 mmHg Positive Pressure (LBPP). The combination of muscarinic blockade with graded LBNP and LBPP was used to evoke graded increases and decreases in sympathetic activity without parasympathetic contributions. The combination of beta blockade with graded LBNP and LBPP was used to produce graded increases and decreases in parasympathetic activity without beta sympathetic contributions. Finally, a combination of both beta and muscarinic blockades with LBNP and LBPP was used to determine the contribution from other, primarily alpha adrenergic, sources. Mean values, spectral analyses and time frequency analysis of R-R interval (HR), Arterial Pressure (AP), peripheral blood flow (RF), Stroke Volume (SV) and peripheral resistance (TPR) were performed for all phases of the study. Skin blood Flow (SF) was also measured in other studies and similarly analyzed. Spectra were examined for changes in three frequency regions (low 0.006 - 0.005 Hz (LF), mid 0.05 - 0.15 Hz (W), and high 0.15 - 0.45 Hz (EF)). The primary objective of the study was to indicate which changes in the mean values and/or spectra of cardiovascular variables consistently correlated with changes in sympatho-vagal balance in response to headward and footward fluid shifts. A secondaey objective was to quantify the vascular and extravascular fluid shifts evoked by LBNP and LBPP. The principal hypothesis being tested was that headward fluid shifts would evoke an increase in parasympathetic activity and footward fluid shifts would evoke an increase in sympathetic activity both of which would be detected by spectral analysis and verified by circulating hormones. Hematocrit (HCT), plasma mass density and plasma renin activity increased with muscarinic blockade and with LBNP, a response indicative of a plasma shift to extravascular spaces. Beta blockade alone or after muscarinic blockade had no effect on HCT or plasma mass density. With respect to intravascular fluid volume distribution, LBNP and LBPP produced sufficient upper body vascular fluid shifts to evoke appropriate autonomic regulatory responses.

Knapp, Charles F.↗

Preliminary Design of a Lightning Optical Camera and ThundEr (LOCATE) Sensor

The preliminary design of an optical/acoustical instrument is described for making highly accurate real-time determinations of the location of cloud-to-ground (CG) lightning. The instrument, named the Lightning Optical Camera And ThundEr (LOCATE) sensor, will also image the clear and cloud-obscured lightning channel produced from CGs and cloud flashes, and will record the transient optical waveforms produced from these discharges. The LOCATE sensor will consist of a full (360 degrees) field-of-view optical camera for obtaining CG channel image and azimuth, a sensitive thunder microphone for obtaining CG range, and a fast photodiode system for time-resolving the lightning optical waveform. The optical waveform data will be used to discriminate CGs from cloud flashes. Together, the optical azimuth and thunder range is used to locate CGs and it is anticipated that a network of LOCATE sensors would determine CG source location to well within 100 meters. All of this would be accomplished for a relatively inexpensive cost compared to present RF lightning location technologies, but of course the range detection is limited and will be quantified in the future. The LOCATE sensor technology would have practical applications for electric power utility companies, government (e.g. NASA Kennedy Space Center lightning safety and warning), golf resort lightning safety, telecommunications, and other industries.

Phanord, Dieudonne D.↗

Individually Identifiable Surface Acoustic Wave Sensors, Tags and Systems

A surface-launched acoustic wave sensor tag system for remotely sensing and/or providing identification information using sets of surface acoustic wave (SAW) sensor tag devices is characterized by acoustic wave device embodiments that include coding and other diversity techniques to produce groups of sensors that interact minimally, reducing or alleviating code collision problems typical of prior art coded SAW sensors and tags, and specific device embodiments of said coded SAW sensor tags and systems. These sensor/tag devices operate in a system which consists of one or more uniquely identifiable sensor/tag devices and a wireless interrogator. The sensor device incorporates an antenna for receiving incident RF energy and re-radiating the tag identification information and the sensor measured parameter(s). Since there is no power source in or connected to the sensor, it is a passive sensor. The device is wirelessly interrogated by the interrogator.

Hines, Jacqueline H.↗

Distal Ejecta from Lunar Impacts: Extensive Regions of Rocky Deposits

Lunar Reconnaissance Orbiter (LRO) Diviner Radiometer, Mini-RF, and LRO Camera data were used to identify and characterize rocky lunar deposits that appear well separated from any potential source crater. Two regions are described: 1) A approximate 18,000 sq km area with elevated rock abundance and extensive melt ponds and veneers near the antipode of Tycho crater (167.5 deg E, 42.5 deg N). This region has been identified previously, using radar and aging data. 2) A much larger and more diffuse region, covering approximately 730,000 sq km, centered near 310 deg E, 35 deg S, containing elevated rock abundance and numerous granular flow deposits on crater walls. The rock distributions in both regions favor certain slope azimuths over others, indicating a directional component to the formation of these deposits. The spatial distribution of rocks is consistent with the arrival of ejecta from the west and northwest at low angles (approximately 10-30 deg) above the horizon in both regions. The derived age and slope orientations of the deposits indicate that the deposits likely originated as ejecta from the Tycho impact event. Despite their similar origin, the deposits in the two regions show significant differences in the datasets. The Tycho crater antipode deposit covers a smaller area, but the deposits are pervasive and appear to be dominated by impact melts. By contrast, the nearside deposits cover a much larger area and numerous granular flows were triggered. However, the features in this region are less prominent with no evidence for the presence of impact melts. The two regions appear to be surface expressions of a distant impact event that can modify surfaces across wide regions, resulting in a variety of surface morphologies. The Tycho impact event may only be the most recent manifestation of these processes, which likely have played a role in the development of the regolith throughout lunar history

Bandfield, Joshua L.↗

A novel photonic oscillator

We report a novel oscillator for photonic RF systems. This oscillator is capable of generating high-frequency signals up to 70 GHz in both electrical and optical domains and is a special voltage-controlled oscillator with an optical output port. It can be used to make a phase-locked loop (PLL) and perform all functions that a PLL is capable of for photonic systems. It can be synchronized to a reference source by means of optical injection locking, electrical injection locking, and PLL. It can also be self-phase locked and self-injection locked to generate a high-stability photonic RF reference. Its applications include high-frequency reference regeneration and distribution, high-gain frequency multiplication, comb-frequecy and square-wave generation, carrier recovery, and clock recovery. We anticipate that such photonic voltage-controlled oscillators (VCOs) will be as important to photonic RF systems as electrical VCOs are to electrical RF systems.

Yao, X. S.↗

Semiconductor Laser Low Frequency Noise Characterization

This work summarizes the efforts in identifying the fundamental noise limit in semiconductor optical sources (lasers) to determine the source of 1/F noise and it's associated behavior. In addition, the study also addresses the effects of this 1/F noise on RF phased arrays. The study showed that the 1/F noise in semiconductor lasers has an ultimate physical limit based upon similar factors to fundamental noise generated in other semiconductor and solid state devices. The study also showed that both additive and multiplicative noise can be a significant detriment to the performance of RF phased arrays especially in regard to very low sidelobe performance and ultimate beam steering accuracy. The final result is that a noise power related term must be included in a complete analysis of the noise spectrum of any semiconductor device including semiconductor lasers.

SEMICONDUCTOR LASERS↗

A rack-mounted precision waveguide-below-cutoff attenuator with an absolute electronic readout

A coaxial precision waveguide-below-cutoff attenuator is described which uses an absolute (unambiguous) electronic digital readout of displacement in inches in addition to the usual gear driven mechanical counter-dial readout in decibels. The attenuator is rack-mountable and has the input and output RF connectors in a fixed position. The attenuation rate for 55, 50, and 30 MHz operation is given along with a discussion of sources of errors. In addition, information is included to aid the user in making adjustments on the attenuator should it be damaged or disassembled for any reason.

Cook, C. C.↗

X-33 Integrated Test facility, Extended Range Simulation

In support of the X-33 Single Stage To Orbit program, NASA Dryden Flight Research Center was selected to provide continuous communications coverage of the X-33 vehicle from launch, through landing at Malmstrom Air Force Base, Montana and Michaels Army Air Field, Utah. An extensive real-time range simulation capability is being developed to ensure successful communications with the autonomous X-33 vehicle. This paper will provide an overview of the various levels of simulation being developed to support the X-33 extended range subsystems. These subsystems include the Flight Termination System, L-Band command uplink subsystem and the S-Band telemetry downlink subsystem. In addition, the radar model developed provides continuous azimuth, elevation and range information based on the flight trajectory. The Dynamic Ground Station Analysis model developed by NASA Goddard Space Flight Center, calculate the received signal strength at each ground station. This model takes into consideration Radio Frequency (RF) link parameters such as frequency, antenna gain, space loss, plasma effects and the vehicle's position and attitude at any point in time during the flight path. All three RF links are then attenuated based on this calculated level and the RF signals are sent into telemetry receivers to emulate remote sites, or the power incident on the vehicle from uplinked signals. The best source received telemetry data is then passed back to the Launch and Mission Control Monitoring System (LMCMS) resident in the Operations Control Center. The LMCMS also provides the range simulation system the uplink command combined with differential GPS corrections. Later stages will require the progressive integration of actual range hardware with this simulation effort, leading to communication between telemetry, uplink and FTS antennas at NASA Dryden Flight Research Center, with vehicle antennas mounted on the Walter C. Williams Research Aircraft Integration Facility (RAIF). Decommutated Pulse Code Modulated (PCM) data is displayed on one of the four monitors that comprise the Range Safety Officer's (RSO) station. Also displayed are instantaneous impact prediction models, and Federal Aviation Administration (FAA) data for notification of other traffic in the area. Aside from initiating the flight termination command and validating communication links, the RSO station with the range simulation will be used to provide both range control and range safety officers training. The training is necessary to perform their respective functions with greater levels of confidence prior to first flight.