Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “REACTOR ACCIDENT SIMULATION”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Severe Accident Modeling for Cyber Scenarios

A generic severe accident model of a PWR is developed to support analyses of cyber-fault scenarios that may lead to extensive core damage. For this purpose, a MELCOR 2.1 model of a generic PWR is created that is capable of simulating primary and secondary thermal-hydraulics, core heatup and fuel degradation, RPV failure, containment response, and radionuclide release and transport to the environment. The size and detail of the severe accident model are intended to facilitate scoping analyses of various cyber-based scenarios in an automated, dynamic framework. A dynamic job scheduler such as ADAPT will be used to evaluate many accident scenarios in an automated fashion utilizing parallel computing. Individual test calculations are first conducted of a basic unmitigated scenario (i.e. no significant operator intervention) with a cyber-based accident initiator. This preliminary assessment is used to gauge modelling capabilities for further, expanded cyber accident scenarios in conjunction with ADAPT. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Quantification of the importance of the modeling fidelity in the Best Estimate Plus Uncertainty analysis

In this work, the multi-physics coupling of CTF-PARCS for both steady-state and transient simulations is evaluated focusing on the quantification of the importance of the modeling fidelity when applied to the Best Estimate Plus Uncertainty safety analysis. For the steady-state, a Picard iteration approach is adopted in the coupled code while for the transient an explicit approach has been developed as a first step. The CTF-PARCS coupling is applied to the REA at HFP BOC scenario proposed in the exercise I-2c of LWR-UAM benchmark Phase III. Two different modeling choices are investigated for the nominal calculations. The first consists of including the 3D burnup information in CTF, and the second of modeling the spacers grids in both PARCS and CTF. It is observed that due to the degradation of the fuel thermal conductivity, the 3D burnup inclusion in CTF leads to significant higher centerline temperatures than the base case, with a difference up to 300 K. The spacer grids modeling shows the expected power and temperature decrease in the axial positions of the spacer grids. For the uncertainty quantification study, the multi-physics modeling including the burnup information in CTF is used. The results show that the inserted reactivity has a relative standard deviation of 13.6% mainly attributed to the nuclear data. The maximum linear power has a relative standard deviation of 16.2% due to the nuclear data as well, while the maximum centerline temperature has a relative standard deviation of 3.5% primarily caused by the fuel thermal conductivity. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

System code evaluation of near-term accident tolerant claddings during pressurized water reactor station blackout accidents

Following the Fukushima Daiichi nuclear accident in 2011, researches on Accident-tolerant fuels (ATFs) are currently of high interest in not only the nuclear industry but also governmental and international organizations. In this work, a quantitative evaluation of the performance of monolithic FeCrAl cladding and Cr-coated Zircaloy cladding has been performed for Pressurized Water Reactor (PWR) Station Blackout (SBO) accidents. A generic PWR model has been built in system thermal-hydraulics code TRACE based on the Surry Nuclear Power Station with counter-current natural circulation modelling capability for hotleg and steam generator U-tube components during the accidents. The base model results are then compared to MELCOR and RELAP simulations to verify the system component implementation in TRACE. Two PWR SBO scenarios were investigated, including: short-term SBO and long-term SBO with early reactor coolant pump (RCP) seal failure. These scenarios are defined to be very similar to the accidents studied in the State-of-the-Art Reactor Consequence Analysis (SOARCA) project. TRACE code is modified to reflect the oxidation kinetics of FeCrAl and Cr-coating. Larson-Miller creep rupture model is also implemented in TARCE using its built-in control systems to simulate the creep rupture of hotlegs. Additionally, the comparison between the TRACE models with and without the counter-current flow modeling resulted in significant difference when comparing ATF cladding to Zircaloy for short term SBO, while it marginal impacted the performance during long term SBO with RCP seal failure. For short term SBO, both ATF cladding underwent hot leg creep rupture ~20 min after Zircaloy cladding. While Zircaloy and Cr-coated cladding had generated significant amount of hydrogen gas (>10 kg) before the creep rupture event, FeCrAl cladding had only generated <0.5 kg of hydrogen gas. For long term SBO with RCP seal failure, significant hydrogen generation and fuel melting was predicted before hot leg creep rupture for the ATF cladding while providing only 10–20 min additional coping time compared to Zircaloy.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

The Development of a Demonstration Passive System Reliability Assessment

In this paper, the details of the development of a demonstration problem to assess the reliability of a passive safety system are presented. An advanced small modular reactor (advSMR) design, which is a pool-type sodium fast reactor (SFR) coupled with a passive reactor cavity cooling system (RCCS) is described. The RELAP5-3D models of the advSMR and RCCS that will be used to simulate a long-term station blackout (SBO) accident scenario are presented. Proposed benchmarking techniques for both the reactor and the RCCS are discussed, which includes utilization of experimental results from the Natural convection Shutdown heat removal Test Facility (NSTF) at the Argonne National Laboratory. Details of how mechanistic methods, specifically the Reliability Method for Passive Systems (RMPS) approach, will be utilized to determine passive system reliability are presented. The results of this mechanistic analysis will ultimately be compared to results from dynamic methods in future work. This work is part of an ongoing project at Argonne to demonstrate methodologies for assessing passive system reliability.

Bucknor, Matthew↗

Computational fluid dynamics modeling of two-phase flow in a BWR fuel assembly. Final CRADA Report.

A direct numerical simulation capability for two-phase flows with heat transfer in complex geometries can considerably reduce the hardware development cycle, facilitate the optimization and reduce the costs of testing of various industrial facilities, such as nuclear power plants, steam generators, steam condensers, liquid cooling systems, heat exchangers, distillers, and boilers. Specifically, the phenomena occurring in a two-phase coolant flow in a BWR (Boiling Water Reactor) fuel assembly include coolant phase changes and multiple flow regimes which directly influence the coolant interaction with fuel assembly and, ultimately, the reactor performance. Traditionally, the best analysis tools for this purpose of two-phase flow phenomena inside the BWR fuel assembly have been the sub-channel codes. However, the resolution of these codes is too coarse for analyzing the detailed intra-assembly flow patterns, such as flow around a spacer element. Advanced CFD (Computational Fluid Dynamics) codes provide a potential for detailed 3D simulations of coolant flow inside a fuel assembly, including flow around a spacer element using more fundamental physical models of flow regimes and phase interactions than sub-channel codes. Such models can extend the code applicability to a wider range of situations, which is highly important for increasing the efficiency and to prevent accidents.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Design of a Loss of Coolant Blowdown Capsule for Remote Assembly with High Burnup Fuel

The Transient Water Irradiation System is an enhanced capability capsule type irradiation vehicle designed to support fuel safety research for light water reactor specimens in the Transient Reactor Test Facility and is designed to simulate loss of coolant and reactivity-initiated accidents. The capsule was designed, deployed, and commissioned with fresh fuel specimens to validate instrumentation and prepare for previously irradiated high burnup specimens. The irradiation system features an extensive in-situ instrumentation package to detect phenomena typical to light water reactor fuels. To accommodate the assembly with high burnup specimens inside the Hot Fuel Examination Facility, and to ensure instrumentation integrity is maintained throughout assembly, the design was updated to support remote handling. The updated design features a hinge mechanism which allows for remote pre-irradiated specimen loading and assembly while protecting sensitive instrumentation by relocating during loading. Fixtures and equipment have been developed to handle the experiment capsule and components in cell, and to support remote assembly. The experiment module also includes radiation shielding and contamination control to support operations after removal from the hot cell.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

High-burnup boiling water reactor steady-state operating conditions and fuel performance analysis

The primary operational costs for existing nuclear reactors are plant operation costs, maintenance costs, and fuel costs, all of which are influenced by the materials used and the design of the reactor core. Optimizing core design parameters—including burnup limits and enrichment levels—can lengthen cycles, reduce outages, reduce reload batch fractions and spent fuel storage requirements, and lower maintenance and operating expenses, thereby enhancing economic viability. Furthermore, developing higher-fidelity tools to simulate these parameters enables better identification of the available margin, improves overall plant safety, and improves the understanding a given plant’s responses to accident scenarios. Here, in the US, much of the research and development focus has traditionally been on pressurized water reactors (PWRs), but boiling water reactors (BWRs) comprise approximately one-third of the US reactor fleet. Modeling and simulation advances for BWRs and PWRs—particularly those achieved through the Nuclear Energy Advanced Modeling and Simulation (NEAMS) program—are crucial to the long-term viability of the light–water reactor industry. A key research area of the high burnup and increased enriched fuel initiative is focused on addressing issues related to postulated loss-of-coolant accident (LOCA) scenarios. NEAMS has dedicated significant effort to enhancing tools to better support BWRs. A current focus is showcasing the BWR framework for high-burnup LOCA analysis. This high-fidelity steady-state analysis is a first step toward demonstrating a best-estimate, pin-by-pin high-burnup BWR LOCA analysis to assess full-core cladding rupture behavior for a representative BWR. The objective of this effort is to provide a modeling capability that will help elucidate and provide a best-estimate evaluation for cladding rupture susceptibility in BWRs. This modeling capability could then be used to prevent and/or mitigate cladding ruptures in postulated accident scenarios without penalizing operational parameters. Additionally, the results of this work will help identify strategies for finding additional margins or potentially limiting cladding ruptures through core design optimizations to enable more efficient core designs.

Capps, Nathan [Oak Ridge National Laboratory (ORNL↗

Using CFD tools to model separate effects of HTR air ingress accident phenomena - 18508

The air ingress phenomena under the HTR conditions represent the important area of nuclear safety. Best practice guidelines for the use of CFD in nuclear safety applications are mainly based on water cooled reactors while in HTR the gas is used as a coolant. The ambition of this paper is to define the best recommendations and description of needed settings of CFD models solving the separate effects of air ingress accident phenomena. The JAERI experiments deal with phenomena of air ingress during the early stages of the accident. Experiments investigate the basic features of the flow behavior of the gas mixture and regard the phenomena of the molecular diffusion and the natural convection of the gas mixture with the graphite oxidation reaction. The separate effects simulations of air ingress accident were performed using CFD code ANSYS Fluent. Whole graphite oxidation process including all three main chemical reactions was successfully modeled. The new findings and useful information were gathered to be extrapolated to the integral effects level for the following phase. The role of the computational mesh and all important input parameters were discussed in detail and many in sensitivity studies were performed. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The MELCOR Analysis of Chinshan Nuclear Power Plant Spent Fuel Pool for Fukushima-like Accident

The safety analysis of the nuclear power plant (NPP) is very important work in the NPP safety. Especially after the Fukushima NPP accident occurred, the importance of NPP safety analysis has been raised and there is more concern for the safety of NPPs in Taiwan. Because the earthquake and tsunami occurred, the cooling system of spent fuel pool failed and the safety issue of spent fuel pool generated in Japan's Fukushima NPP. Chinshan NPP is the first NPP in Taiwan which is BWR/4 plant and OLTP (Original Licensed Thermal Power) for each unit is 1775 MWt. Chinshan NPP finished SPU (stretch power uprate) and the operating power is 103.66% of the OLTP, which is 1840 MWt now. After Fukushima NPP accident occurred, in order to concern the safety of Chinshan NPP spent fuel pool, we performed the safety analysis of spent fuel pool by using MELCOR/SNAP which also assumed the cooling system of spent fuel pool failed. The geometry of Chinshan NPP spent fuel pool is 12.17 m x 7.87 m x 11.61 m and the initial condition is 60 deg. (water temperature) / 1.013 x 10{sup 5} Pa. And, the total power of the fuels is roughly 8.9 MWt initially. MELCOR is developed by Sandia National Laboratories. MELCOR is a fully integrated, engineering-level computer code that models the progression of severe accidents in light water reactor NPPs, including containment response and leakage of activity to the environment. A broad spectrum of severe accident phenomena in both BWRs and PWRs is treated in MELCOR in a unified framework. These include thermalhydraulic response in the reactor coolant system, reactor cavity, containment, and confinement buildings; core heatup, degradation, and relocation; core-concrete attack; hydrogen production, transport, and combustion; fission product release and transport behavior. Current uses of MELCOR include estimation of severe accident source terms and their sensitivities and uncertainties in a variety of applications. According to Dr. Carbajo's paper, MELCOR was used to perform the study of spent fuel pool of Fukushima Daiichi Unit 4. Niina E. Koenoenen used MELCOR to establish the spent fuel pool model of a Nordic BWR. The loss-of-pool-cooling accidents was simulated and analyzed by this model. The above studies indicate that MELCOR is capable of handling the simulation of the spent fuel pool. An increasing number of researchers are using MELCOR code to analyze test facilities and nuclear power plants. Jun Wang et al. used MELCOR to perform core degradation simulation and MELCOR results were compared with CORA experimental data. Through this work, they reviewed the performance of MELCOR COR package in detail. Tae Woon Kim et al. developed MELCOR model of APR1400 (an advanced pressurized water reactor). They used this model to perform the LBLOCA transient simulation and sensitivity study. Longze Li et al. established the MELCOR model of CPR1000 (a Chinese pressurized reactor 1000-MW power plant). The station blackout (SBO) with failure of the steam generator (SG) safety relief valve (SRV) transient was simulated and analyzed by this model. SNAP is a graphic user interface program that processes the inputs and outputs of MELCOR. In addition, there is an animation function in SNAP which can present the animation of analysis results. There are two main steps in this research. The first step was the establishment of Chinshan NPP spent fuel pool MELCOR/SNAP model. And the transient analysis of Chinshan NPP spent fuel pool MELCOR/SNAP model under the cooling system failure condition was performed. The next step was the comparison among the MELCOR, TRACE and CFD data. TRACE and CFD data were from INER reports. In addition, the animation model of Chinshan NPP spent fuel pool was presented by using the animation function of SNAP with MELCOR/SNAP analysis results. This study has developed MELCOR/SNAP model of Chinshan NPP spent fuel pool successfully. By using the above model, the safety analysis of the spent fuel pool was performed under the cooling system of spent fuel pool failed condition. The analysis results of MELCOR, TRACE and CFD were similar in this case. It indicated that there was a respectable accuracy in MELCOR/SNAP model. The analysis results depicted that the uncovered of the fuels occurred at 2.6 day and the metal-water reaction of fuels occurred roughly at 3.7 day after the cooling system failed. The above results indicated that the failure of cladding occurred after 3.7 day. This study's results can help to evaluate the safety issue of Chinshan NPP spent fuel pool. In addition, the cooling system and some mitigation measures of spent fuel pool is not simulated in the above model. However, we will do it in the future. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

All-Speed Methods and Long-Duration Time Integration for Incorporation into the 7-Equation Two-Phase Model

The numerical simulation of multiphase flows in Light Water (Nuclear) Reactors, LWRs, for normal, accident, and off-normal operation, and for operational optimization must cover a huge disparity of transient time durations, from milliseconds to years. In addition, our recent work has shown that the application of classical Riemann approaches, which pervade modern computational fluid dynamics (CFD), suffer numerical accuracy degradation, especially for compressible liquid flows. In this setting, all-speed or Mach uniform methods are need which can be accurately and efficiently integrated over a very large range of time scales. Thus we need a multi-time-scale integration approach to compliment our previously documented multi-spatial-scale approach to multiphase flow modeling. This report briefly summarizes our efforts in these areas.

42 ENGINEERING↗

Advanced Control and Protection system Design Methods for Modular HTGRs

The project supported the Nuclear Regulatory Commission (NRC) in identifying and evaluating the regulatory implications concerning the control and protection systems proposed for use in the Department of Energy's (DOE) Next-Generation Nuclear Plant (NGNP). The NGNP, using modular high-temperature gas-cooled reactor (HTGR) technology, is to provide commercial industries with electricity and high-temperature process heat for industrial processes such as hydrogen production. Process heat temperatures range from 700 to 950 C, and for the upper range of these operation temperatures, the modular HTGR is sometimes referred to as the Very High Temperature Reactor or VHTR. Initial NGNP designs are for operation in the lower temperature range. The defining safety characteristic of the modular HTGR is that its primary defense against serious accidents is to be achieved through its inherent properties of the fuel and core. Because of its strong negative temperature coefficient of reactivity and the capability of the fuel to withstand high temperatures, fast-acting active safety systems or prompt operator actions should not be required to prevent significant fuel failure and fission product release. The plant is designed such that its inherent features should provide adequate protection despite operational errors or equipment failure. Figure 1 shows an example modular HTGR layout (prismatic core version), where its inlet coolant enters the reactor vessel at the bottom, traversing up the sides to the top plenum, down-flow through an annular core, and exiting from the lower plenum (hot duct). This research provided NRC staff with (a) insights and knowledge about the control and protection systems for the NGNP and VHTR, (b) information on the technologies/approaches under consideration for use in the reactor and process heat applications, (c) guidelines for the design of highly integrated control rooms, (d) consideration for modeling of control and protection system designs for VHTR, and (e) input for developing the bases for possible new regulatory guidance to assist in the review of an NGNP license application. This NRC project also evaluated reactor and process heat application plant simulation models employed in the protection and control system designs for various plant operational modes and accidents, including providing information about the models themselves, and the appropriateness of the application of the models for control and protection system studies. A companion project for the NRC focused on the potential for new instrumentation that would be unique to modular HTGRs, as compared to light-water reactors (LWRs), due to both the higher temperature ranges and the inherent safety features.

08 HYDROGEN↗

A Study of BWR Mark I Station Blackout Accident with GOTHIC Modeling

The overall objective of this study is to develop a high-fidelity simulation capability for the analysis of accident progression during Station Black-Out (SBO) scenario in Boiling Water Reactor (BWR) Mark I plant. The motivation is on predicting the effectiveness of containment venting within accident mitigation strategy and how to avoid core melt by choosing a proper time to initiate primary system venting. In this work, a GOTHIC model has been developed to support characterization of reactor safety systems performance and evaluation of the venting strategy. The GOTHIC model provides a seamless coupled simulation of the reactor coolant system and the containment system based on the design of the Peach Bottom-2 plant system. Efforts are also taken on the analysis for the primary system venting strategy. The safe time intervals (so-called “safe venting window”) to initiate the primary system depressurization in order to optimize the early cooling strategy by adding fire water and avoid core melt are also studied based on the heat removal capability (HRC) of the reactor vessel coolant. This concept is instructive for the operation of the safety systems during the SBO accident mitigation.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Efficiency Calibration of FGMS Cold Traps

This plan describes tests to determine the efficiency calibrations for the Fission Gas Monitoring System (FGMS) by the measurements of 85Kr and 133Xe gamma rays. FGMS collects fission product gases released from irradiated Advanced Gas Reactor tristructural-isotropic-coated particle fuel specimens during post-irradiation heating in the Fuel Accident Condition Simulator (FACS) furnace. FGMS is composed of two charcoal-filled, liquid-nitrogen cooled traps that are each monitored by a high purity germanium (HPGe) detector. All irradiated Advanced Gas Reactor fuel specimens contain 85Kr (t1/2 = 10.8 year); however, significant short-lived fission products such as 133Xe (t1/2 = 5.2 day) and 131I (t1/2 = 8.0 day) have decayed away by the time they reach the FACS for testing. In order to measure the releases of these short-lived fission products during safety testing in the FACS furnace, a re-irradiation of samples is necessary in the Neutron Radiography Reactor. This requires the FGMS be calibrated for the fission gas 133Xe, in addition to 85Kr. Because any re-irradiated fuel specimen will have both 85Kr and 133Xe present, the collection efficiency from a mixture of krypton and xenon needs to be determined.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Rethinking Sensitivity Analysis of Nuclear Simulations with Topology

In nuclear engineering, understanding the safety margins of the nuclear reactor via simulations is arguably of paramount importance in predicting and preventing nuclear accidents. It is therefore crucial to perform sensitivity analysis to understand how changes in the model inputs affect the outputs. Modern nuclear simulation tools rely on numerical representations of the sensitivity information -- inherently lacking in visual encodings -- offering limited effectiveness in communicating and exploring the generated data. In this paper, we design a framework for sensitivity analysis and visualization of multidimensional nuclear simulation data using partition-based, topology-inspired regression models and report on its efficacy. We rely on the established Morse-Smale regression technique, which allows us to partition the domain into monotonic regions where easily interpretable linear models can be used to assess the influence of inputs on the output variability. The underlying computation is augmented with an intuitive and interactive visual design to effectively communicate sensitivity information to the nuclear scientists. Our framework is being deployed into the multi-purpose probabilistic risk assessment and uncertainty quantification framework RAVEN (Reactor Analysis and Virtual Control Environment). We evaluate our framework using an simulation dataset studying nuclear fuel performance.

computational topology↗

CTF: A modernized, production-level, thermal hydraulic solver for the solution of industry-relevant challenge problems in pressurized water reactors

CTF is a thermal hydraulic (T/H) subchannel tool that has been extensively developed over the past ten years as part of the Consortium for Advanced Simulation of Light Water Reactors (CASL) program. The code was selected early in the CASL program for support of high-impact challenge problems that were found to be relevant to the nuclear industry and its currently operating fleet of pressurized water reactors (PWRs), including issues such as departure from nucleate boiling (DNB), crud-induced power shifts (CIPSs), and reactivity-insertion accidents (RIAs). By incorporating CTF into the multiphysics Virtual Environment for Reactor Application (VERA) core simulator software developed by CASL, CTF has become the primary means of providing fluid and fuel thermal feedback, as well as T/H figure-of-merits (FOMs) in large-scale reactor simulations. With the goal of solving industry challenge problems, CASL placed great emphasis on developing high-quality, high-performance, validated software tools that offer higher fidelity than what is currently possible with current industry methods. In support of this effort, CTF was developed from a research tool into an nuclear quality assurance (NQA-1)–compliant, production-level software tool that is capable of addressing the stated challenge problems and goals of CASL. This work presents a review of the major technological achievements that were realized in developing CTF over the past decade of the CASL program and presents an overview of the code solution approach and closure models.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

VERA Transient Capability to Support ATF/High Burnup Fuel/HALEU Conversion

The Virtual Environment for Reactor Applications (VERA) was developed under the Consortium for Advanced Simulation of Light Water Reactors (CASL). The goal of this new code suite was to provide high-fidelity, whole-core simulation using pin-resolved physics. Extensive steady-state validation of VERA has been performed for reactor cycle depletion simulations and other related simulations. Transient simulations were not a major component of the CASL work; reactivity insertion accidents (RIAs) received most of the focus. However, there are other design basis accidents (DBA) which are of great importance for reactor design and licensing.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Operating displays - new concept: high performance displays - 118

New control rooms in Nuclear Power Plants using digital Distributed Control System (DCS) operated with software displays, are providing thousands of signals to the operating crew. When an event happens, the Flood of information provided to operators could obscure the initiator event increasing the operator response time, work load and complicating the selection of the actions to be performed. There are some initiatives that are trying to minimize the 'avalanche effect' as the alarm engineering filtering and prioritization or diagnostic displays. Likewise, new control rooms are lost the availability to know the plant status just with a quick glance to the panel indicators. Regarding Small Modular Reactors, where in some cases four operators should monitor and control twelve reactors, these problems are even more significant. The challenge is to find a solution, based on current digital systems, that supply information to operators in order to prevent events and take early actions to minimize or avoid any unexpected incident. In order to minimize human errors, Tecnatom has developed a specific set of displays, called 'High Performance Displays' (HPD) based on objectives, work environment limitation, and non-anticipated events. These displays are being design following the HFE standards: applying the NUREG-0711 elements to identify the information that they have to content and the NUREG-0700 to design the interface. The function of these displays is monitoring the plant situation in a way that the operators are able to recognize any potential event at a simple glance but controlling thousands of signals through pattern recognition, symmetries, regular polygons and colors. The objective of the HPD is to provide an integrated function minimizing the tunnel effect and reduce the workload during the diagnosis phase. Moreover, HPD enhance operators to take the right actions to anticipate the response to any event, even avoiding it, if possible This paper analyzes how HPD's have been design as well as presents the results of a preliminary validation of their capabilities. The preliminary validation is a reduce validation in a full scope simulator running two representative scenarios of abnormal and emergency operation. The analysis is focused on the first stage of the event, i.e. the detection phase, HPD's have been installed in a generic full scope simulator of a nuclear power plant, digital controlled. Both scenarios have been performed by two different operator crews. The first operator shift has worked with the conventional human machine interface, that is, displays similar to the ones currently installed in existing nuclear power plant with digital control. The second crew, reproduce the same scenarios but with HPD available. The studio collects preliminary data in order to compare results, draw lesson learned from the experience to improve HPD design, and find solutions in terms of reducing human errors, human workload, and increase the availability of the plant. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

V and V of the HTR Code Package (HCP) as a comprehensive HTR steady state and transient safety analysis framework - 18664

The HTR code package (HCP) allows for the simulation of several safety-related aspects of a High Temperature Reactor core in a highly integrated manner. HCP currently couples the thermo-fluid dynamics and time dependent neutronics code MGT, the spectrum code TRISHA, the burn up code TNT, the fuel management code SHUFLE and the fission product release code STACY. During its development, state-of-the-art programming techniques and standards are applied. The cross sections in HCP are generated by a 0D- or 1D solver featuring an innovative approach to treat the double heterogeneity of pebble fuel. Also major improvements have been made to optimize the nuclear data library based on ENDF/B-VII. Two advanced fuel management models are provided by the code module SHUFLE that go far beyond the capabilities of existing system codes like VSOP. The source term analysis code module STACY is coupled to HCP providing release rate calculations with a high spatial resolution making use of the nuclide densities provided by TNT. An outstanding new feature of HCP is the possibility to simulate long-term operation scenarios based on OTTO or MEDUL fuel shuffling schemes as well as selected transients in one integrated code package. Even alternating steady state/transient/steady state simulations are possible. So with HCP different fuel strategies and their influence on various kinds of accidents can be examined with one consistent reactor model. This paper provides an overview of the development status of the HCP and reports about selected benchmark results. It is demonstrated that the new system code HCP is capable to replace existing stand-alone codes like VSOP, TINTE/MGT, FRESCO or PANAMA while introducing new features, which so far to our knowledge were not available in the field of HTR safety research. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗