Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIOLOGY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Radiologic Percutaneous Gastrostomy in Nondistended Stomach: A Modified Approach

IntroductionGastrostomy tube placement for patients requiring long-term nutritional support may be performed using different techniques including endoscopic, surgical, and percutaneous radiologically guided methods. Radiologically inserted gastrostomy (RIG), typically performed when percutaneous endoscopic gastrostomy is not possible, requires proper gastric distension that is achieved by insufflating air through a nasogastric tube. We describe a simple technique to prevent air escape from the stomach during gastrostomy tube placement. To the best of our knowledge, this technique has not yet been described in the literature.Materials and MethodsFour patients with unsuccessful percutaneous endoscopic gastrostomy were referred for fluoroscopic-guided gastrostomy. One patient had a pyriform sinus tumor and three had an ischemic stroke causing dysphagia. Gastric distention was not achieved in the patients due to air escaping into the bowel during the standard RIG procedure. A modified approach using a balloon catheter inflated in the pylorus to avoid air passing into the duodenum permitted successful RIG.ResultsThe modified RIG procedure was successfully carried out in all cases without complications.DiscussionInadequate air distension of the stomach is an unusual event that causes a failure of gastrostomy tube placement and an increased risk of both major and minor complications. The use of a balloon catheter inflated in the first part of the duodenum prevents the air passage into the bowel allowing the correct positioning of the gastrostomy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Outcomes After Chemo-Embolization in Patients with Advanced-Stage Hepatocellular Carcinoma: An Evaluation of Different Radiologic Response Criteria

PurposeThe purpse of this study was to evaluate the ability of various radiologic response criteria to predict patient outcomes after trans-arterial chemo-embolization with drug-eluting beads (DEB-TACE) in patients with advanced-stage (BCLC C) hepatocellular carcinoma (HCC).Materials and methodsHospital records from 2005 to 2011 were retrospectively reviewed. Non-infiltrative lesions were measured at baseline and on follow-up scans after DEB-TACE according to various common radiologic response criteria, including guidelines of the World Health Organization (WHO), Response Evaluation Criteria in Solid Tumors (RECIST), the European Association for the Study of the Liver (EASL), and modified RECIST (mRECIST). Statistical analysis was performed to see which, if any, of the response criteria could be used as a predictor of overall survival (OS) or time-to-progression (TTP).Results75 patients met inclusion criteria. Median OS and TTP were 22.6 months (95 % CI 11.6–24.8) and 9.8 months (95 % CI 7.1–21.6), respectively. Univariate and multivariate Cox analyses revealed that none of the evaluated criteria had the ability to be used as a predictor for OS or TTP. Analysis of the C index in both univariate and multivariate models showed that the evaluated criteria were not accurate predictors of either OS (C-statistic range: 0.51–0.58 in the univariate model; range: 0.54–0.58 in the multivariate model) or TTP (C-statistic range: 0.55–0.59 in the univariate model; range: 0.57–0.61 in the multivariate model).ConclusionCurrent response criteria are not accurate predictors of OS or TTP in patients with advanced-stage HCC after DEB-TACE.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiologic Placement of Uncovered Stents for the Treatment of Malignant Colonic Obstruction Proximal to the Descending Colon

PurposeTo evaluate the safety, feasibility, and patency rates of radiologic placement of uncovered stents for the treatment of malignant colonic obstruction proximal to the descending colon.Materials and MethodsThis was a retrospective, single-center study. From May 2003 to March 2015, 53 image-guided placements of uncovered stents (44 initial placements, 9 secondary placements) were attempted in 44 patients (male:female = 23:21; mean age, 71.8 years). The technical and clinical success, complication rates, and patency rates of the stents were also evaluated. Technical success was defined as the successful deployment of the stent under fluoroscopic guidance alone and clinical success was defined as the relief of obstructive symptoms or signs within 48 h of stent deployment.ResultsIn total, 12 (27.3 %) patients underwent preoperative decompression, while 32 (72.7 %) underwent decompression with palliative intent. The technical success rate was 93.2 % (41/44) for initial placement and 88.9 % (8/9) for secondary placement. Secondary stent placement in the palliative group was required in nine patients after successful initial stent placement due to stent obstruction from tumor ingrowth (n = 7) and stent migration (n = 2). The symptoms of obstruction were relieved in all successful cases (100 %). In the palliative group, the patency rates were 94.4 % at 1 month, 84.0 % at 3 months, 64.8 % at 6 months, and 48.6 % at 12 months.ConclusionsThe radiologic placement of uncovered stents for the treatment of malignant obstruction proximal to the descending colon is feasible and safe, and provides acceptable clinical results.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Anesthesia Practices for Interventional Radiology in Europe

PurposeThe Cardiovascular and Interventional Radiological Society of Europe (CIRSE) prompted an initiative to frame the current European status of anesthetic practices for interventional radiology, in consideration of the current variability of IR suite settings, staffing and anesthetic practices reported in the literature and of the growing debate on sedation administered by non-anesthesiologists, in Europe.MethodsAnonymous online survey available to all European CIRSE members to assess IR setting, demographics, peri-procedural care, anesthetic management, resources and staffing, pain management, data collection, safety, management of emergencies and personal opinions on the role CIRSE should have in promoting anesthetic care for interventional radiology.ResultsPredictable differences between countries and national regulations were confirmed, showing how significantly many “local” factors (type and size of centers, the availability of dedicated inpatient bed, availability of anesthesia staff) can affect the routine practice and the expansion of IR as a subspecialty. In addition, the perception of the need for IR to acquire more sedation-related skills is definitely stronger for those who practice with the lowest availability of anesthesia care.ConclusionSignificant country variations and regulations along with a controversial position of the anesthesia community on the issue of sedation administered by non-anesthesiologists substantially represent the biggest drawbacks for the expansion of peri-procedural anesthetic care for IR and for potential initiatives at an European level.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Understanding the Awareness, Knowledge and Perceptions of Interventional Radiology Amongst Undergraduates in the UK

Introduction: The role of interventional radiology (IR) in health care is rapidly expanding in the United Kingdom (UK). However, the presence of IR in the current undergraduate curriculum is lacking. Purpose: This study investigates the awareness, knowledge and perceptions of IR in undergraduates through the clinical years of medical school to suggest future interventions. Methods: A total of 360 questionnaires, designed to test undergraduates’ knowledge of, and exposure to, IR were distributed over a 14-day period in a UK medical institution. Results: Of the 312 respondents (86.7%), the majority had never formally shadowed a radiologist (65.4%) or encountered teaching from an interventional radiologist (54.5%). Most students (88.5%) felt their knowledge of IR was lower than other specialties. Students’ knowledge of IR procedures did not statistically increase through the clinical years. Students were most cognisant of vascular procedures and least aware of IR’s role in oncology. Only 10.9% would consider a career in IR, with 39.7% citing the lack of knowledge and 18.6% citing patient contact as the top reasons for this. Conclusion: Current students have poor exposure to IR through the undergraduate curriculum. Consequently, there is no increase in knowledge of IR clinical practice through the clinical years. Multi-level interventions, incorporating universities and radiological societies are required to increase undergraduate awareness and promote IR as a career. Level of Evidence: Level 3, Local non-random sample.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Radiology and Enterprise Medical Imaging Extensions (REMIX)

Radiology and Enterprise Medical Imaging Extensions (REMIX) is a platform originally designed to both support the medical imaging-driven clinical and clinical research operational needs of Department of Radiology of The Ohio State University Wexner Medical Center. REMIX accommodates the storage and handling of “big imaging data,” as needed for large multi-disciplinary cancer-focused programs. The evolving REMIX platform contains an array of integrated tools/software packages for the following: (1) server and storage management; (2) image reconstruction; (3) digital pathology; (4) de-identification; (5) business intelligence; (6) texture analysis; and (7) artificial intelligence. These capabilities, along with documentation and guidance, explaining how to interact with a commercial system (e.g., PACS, EHR, commercial database) that currently exists in clinical environments, are to be made freely available.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Public Health Response and Medical Management of Internal Contamination in Past Radiological or Nuclear Incidents: A Review

Following a radiological or nuclear emergency, workers, responders and the public may be internally contaminated with radionuclides. Screening, monitoring and assessing any internal contamination and providing necessary medical treatment, especially when a large number of individuals are involved, is challenging. Experience gained and lessons learned from the management of previous incidents would help to identify gaps in knowledge and capabilities on preparedness for and response to radiation emergencies. In this paper, eight largescale and five workplace radiological and nuclear incidents are reviewed cross 14 technical areas, under the broader topics of emergency preparedness, emergency response and recovery processes. The review findings suggest that 1) new strategies, algorithms and technologies are explored for rapid screening of large populations; 2) exposure assessment and dose estimation in emergency response and dose reconstruction in recovery process are supported by complementary sources of information, including ‘citizen science’; 3) surge capacity for monitoring and dose assessment is coordinated through national and international laboratory networks; 4) evidence-based guidelines for medical management and follow-up of internal contamination are urgently needed; 5) mechanisms for international and regional access to medical countermeasures are investigated and implemented; 6) long-term health and medical follow up programs are designed and justified; and 7) capabilities and capacity developed for emergency response are sustained through adequate resource allocation, routine nonemergency use of technical skills in regular exercises, training, and continuous improvement.

61 RADIATION PROTECTION AND DOSIMETRY↗

Acute and Late Toxicity After Dose Escalation to 82 GyE Using Conformal Proton Radiation for Localized Prostate Cancer: Initial Report of American College of Radiology Phase II Study 03-12

Purpose: Several randomized trials have shown a benefit of dose escalation to 78 to 79 Gy for men treated with external radiation for localized prostate cancer. Single-institution data suggest a benefit with even higher doses. American College of Radiology 03-12 is a Phase II trial testing the safety and efficacy of 82 GyE (Gray equivalent) delivered with conformal proton radiation. Methods and Materials: From 2003-2006, 85 men with localized prostate cancer were accrued to American College of Radiology 03-12. Eighty-four were eligible for analysis. They were treated with conformal proton radiation alone to a total dose of 82 GyE. The study was designed to test whether the rate of 18-month Grade 3+ late toxicity was greater than 10%. Results: The median follow-up was 31.6 months. Regarding treatment-related acute toxicity, there were 39 Grade 1 cases (46%), 19 Grade 2 cases (23%) and 2 Grade 3 cases (2%). Regarding genitourinary/gastrointestinal toxicity, there were 42 Grade 1 cases (50%), 12 Grade 2 cases (14%) and 1 Grade 3 case (1%). Regarding late toxicity, there were 28 Grade 1 cases (33%), 22 Grade 2 cases (26%), 6 Grade 3 cases (7%), and 1 Grade 4 case (1%). The late genitourinary/gastrointestinal rates were the same. The estimated rate of Grade 3+ late toxicity at 18 months was 6.08%. Conclusions: Although not free of late toxicity, 82 GyE at 2 GyE per fraction delivered with conformal proton radiation did not exceed the late morbidity target tested in this trial. There was sufficient morbidity, however, that this may be the maximal dose that can be delivered safely with this technique and fractionation.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

International Outdoor Experiments and Models for Outdoor Radiological Dispersal Devices

With the advent of nuclear reactors and the technology to produce radioactive materials in large quantities, concern arose about the use of radioactivity as a poison in warfare, and hence, consideration was given to defensive measures (Smyth 1945). Approximately forty years later, the interest in the environmental- and health effects caused by a deliberate dispersal was renewed, but this time, from the perspective of a malevolent act of radiological terrorism in an urban area. For many years there has been international collaboration in scientific research to understand the range of effects that might result from a device that could be constructed by a sub-national group. In this paper, scientists from government laboratories in Australia, Canada, the United Kingdom, and the United States collectively have conducted a myriad of experiments to understand and detail the phenomenology of an explosive radiological dispersal device.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

The Systems of Radiological Protection for Ionizing and Non-Ionizing Radiation

This paper summarizes the presentations and panel discussion held at Plenary Session 1 of the 16th IRPA International Congress/69th Health Physics Society Annual Meeting, in Orlando, FL, in July 2024. Plenary Session 1 discussed the basics of the systems of radiological protection (RP) for ionizing radiation (IR) and non-ionizing radiation (NIR) and included five presentations and a panel discussion. Rodney Croft, Chair of the International Commission on Non-Ionizing Radiation Protection (ICNIRP), delivered the first presentation. Croft introduced the System of RP for NIR and provided an overview of ICNIRP’s coverage and current areas of work. Werner Rühm, Chair of the International Commission on Radiological Protection (ICRP), delivered the second presentation. He gave an overview of the System of RP for IR and covered the key principles of justification, optimization, and dose limitation, including the current plans of ICRP toward the envisaged revision of the System of RP. The third speaker, Sigurður Magnús Magnússon, from the International Radiation Protection Association (IRPA), provided the perspective of the RP professionals on the development of the Systems of RP for IR and NIR. Emilie van Deventer, from the World Health Organization (WHO), presented WHO’s views of both Systems of RP and discussed the relevant current activities of WHO with regard to IR and NIR. Kathryn Higley, President of the National Council on Radiation Protection and Measurements (NCRP), delivered the final presentation. Higley outlined the history of NCRP, the differences between ICRP and NCRP, and discussed the role of the NCRP in the System of RP, including NCRP’s role to analyze mechanisms of interaction of NIR with biological systems, including humans. The session concluded with a fruitful panel discussion, where the audience had the opportunity to ask the five invited speakers questions.

61 RADIATION PROTECTION AND DOSIMETRY↗

Combining Radiography and Passive Measurements for Radiological Threat Detection in Cargo

Abstract Radiography is widely understood to provide information complimentary to passive detection: while not directly sensitive to radiological materials, radiography can reveal highly shielded regions which may mask a passive radiological signal. We present a method for combining radiographic and passive data which uses the radiograph to provide an estimate of scatter and attenuation for possible sources. This approach allows quantitative use of radiographic images without relying on image interpretation, and results in a probabilistic description of likely source locations and strengths. We present first results for this method for a simple modeled test case of a cargo container driving through a PVT portal. With this inversion approach, we address criteria for an integrated passive and radiographic screening system and how detection of SNM threats might be improved in such a system.

Combining Radiography and Passive Measurements for↗

Predicting error in detecting mammographic masses among radiology trainees using statistical models based on BI-RADS features

Purpose: The purpose of this study is to explore Breast Imaging-Reporting and Data System (BI-RADS) features as predictors of individual errors made by trainees when detecting masses in mammograms. Methods: Ten radiology trainees and three expert breast imagers reviewed 100 mammograms comprised of bilateral medial lateral oblique and craniocaudal views on a research workstation. The cases consisted of normal and biopsy proven benign and malignant masses. For cases with actionable abnormalities, the experts recorded breast (density and axillary lymph nodes) and mass (shape, margin, and density) features according to the BI-RADS lexicon, as well as the abnormality location (depth and clock face). For each trainee, a user-specific multivariate model was constructed to predict the trainee's likelihood of error based on BI-RADS features. The performance of the models was assessed using area under the receive operating characteristic curves (AUC). Results: Despite the variability in errors between different trainees, the individual models were able to predict the likelihood of error for the trainees with a mean AUC of 0.611 (range: 0.502–0.739, 95% Confidence Interval: 0.543–0.680,p < 0.002). Conclusions: Patterns in detection errors for mammographic masses made by radiology trainees can be modeled using BI-RADS features. These findings may have potential implications for the development of future educational materials that are personalized to individual trainees.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Application of the diagnostic radiological index of protection to protective garments

Purpose: Previously, the diagnostic radiological index of protection (DRIP) was proposed as a metric for quantifying the protective value of radioprotective garments. The DRIP is a weighted sum of the percent transmissions of different radiation beams through a garment. Ideally, the beams would represent the anticipated stray radiation encountered during clinical use. However, it is impractical to expect a medical physicist to possess the equipment necessary to accurately measure transmission of scattered radiation. Therefore, as a proof of concept, the authors tested a method that applied the DRIP to clinical practice. Methods: Primary beam qualities used in interventional cardiology and radiology were observed and catalogued. Based on the observed range of beam qualities, five representative clinical primary beam qualities, specified by kV and added filtration, were selected for this evaluation. Monte Carlo simulations were performed using these primary beams as source definitions to generate scattered spectra from the clinical primary beams. Using numerical optimization, ideal scatter mimicking primary beams, specified by kV and added aluminum filtration, were matched to the scattered spectra according to half- and quarter-value layers and spectral shape. To within reasonable approximation, these theoretical scatter-mimicking primary beams were reproduced experimentally in laboratory x ray beams and used to measure transmission through pure lead and protective garments. For this proof of concept, the DRIP for pure lead and the garments was calculated by assigning equal weighting to percent transmission measurements for each of the five beams. Finally, the areal density of lead and garments was measured for consideration alongside the DRIP to assess the protective value of each material for a given weight. Results: The authors identified ideal scatter mimicking primary beams that matched scattered spectra to within 0.01 mm for half- and quarter-value layers in copper and within 5% for the shape function. The corresponding experimental scatter-mimicking primary beams matched the Monte Carlo generated scattered spectra with maximum deviations of 6.8% and 6.6% for half- and quarter-value layers. The measured DRIP for 0.50 mm lead sheet was 2.0, indicating that it transmitted, on average, 2% of incident radiation. The measured DRIP for a lead garment and one lead-alternative garment closely matched that for pure lead of 0.50 mm thickness. The DRIP for other garments was substantially higher than 0.50 mm lead (3.9–5.4), indicating they transmitted about twice as much radiation. When the DRIP was plotted versus areal density, it was clear that, of the garments tested, none were better than lead on a weight-by-weight basis. Conclusions: A method for measuring the DRIP for protective garments using scatter-mimicking primary beams was developed. There was little discernable advantage in protective value per unit weight for lead-alternative versus lead-only garments. Careful consideration must be given to the balance of protection and weight when choosing a lead-alternative protective garment with a lower specified “lead equivalence,” e.g., 0.35 mm. The DRIP has the potential to resolve this dilemma. Reporting the DRIP relative to areal density is an ideal metric for objective comparisons of protective garment performance, considering both protective value in terms of transmission of radiation and garment weight.

60 APPLIED LIFE SCIENCES↗

MO-DE-BRA-06: MrRSCAL: A Radiological Simulation Tool for Resident Education

Purpose: The goal of this project was to create a readily accessible, comprehensive-yet-flexible interactive MRI simulation tool for use in training and education of radiology residents in particular. This tool was developed to take the place of an MR scanner in laboratory activities, as magnet time has become scarce while hospitals are optimizing clinical scheduling for improved throughput. Methods: MrRSCAL (Magnetic resonance Resident Simulation Console for Active Learning) was programmed and coded using Matlab on a Mac workstation utilizing OS X platform. MR-based brain images were obtained from one of the co-authors and processed to generate parametric maps. Scanner sounds are also generated via mp3 convolution of a single MR gradient slew with a time-profile of gradient waveforms. Results: MrRSCAL facilitates the simulation of multiple MR sequences with the ability to alter MR parameters via an intuitive GUI control panel. The application allows the user to gain real-time understanding of image transformation when varying these said parameters by examining the resulting images. Lab procedures can be loaded and displayed for more directed study. The panel is also configurable, providing a simple interface for elementary labs or a full array of controls for the expert user. Conclusion: Our introduction of MrRSCAL, which is readily available to users with a current laptop or workstation, allows for individual or group study of MR image acquisition with immediate educational feedback as the MR parameters are manipulated. MrRSCAL can be used at any time and any place once installed, offering a new tool for reviewing relaxometric and artifact principles when studying for boards or investigating properties of a pulse sequence. This tool promises to be extremely useful in conveying traditionally difficult and abstract concepts involved with MR to the radiology resident and other medical professionals at large.

60 APPLIED LIFE SCIENCES↗

SU-F-E-16: A Specific Training Package for Medical Physicists in Support to Nuclear and Radiological Emergency Situations

Purpose: To provide the professional medical physicists with adequate competencies and skills in order to help them get prepared to support Nuclear or Radiological Emergency (NRE) situations. Methods: Although clinical medical physicists working have in-depth knowledge in radiation dosimetry, including dose reconstruction and dose measurements, they are usually not involved in NRE situations. However, in a few instances where medical physicists were involved in NREs, it appeared that many lacked specific knowledge and skills that are required in such situations. This lack of specific knowledge and skills is probably due to the fact that most current medical physics curricula do not include a specific module on this topic. As a response to this finding, the IAEA decided to initiate a project to develop a specific training package to help prepare medical physicists to support NRE situations. The training package was developed with the kind support of the Government of Japan and in collaboration with Fukushima Medical University (FMU) and the National Institute of Radiological Sciences (NIRS). Results: The first International Workshop to test the training package was held in Fukushima, Japan in June 2015. It consisted of lectures, demonstrations, simulation, role play, and practical sessions followed by discussions. The training was delivered through 14 modules which were prepared with the support of 12 lecturers. A knowledge assessment test was done before the workshop, followed by the same test done at the end of the Workshop, to assess the knowledge acquired during the training. Conclusion: The Workshop was successfully implemented. The overall rating of the workshop by the participants was excellent and all participants reported that they acquired a good understanding of the main issues that are relevant to medical physics support in case of NRE situations. They are expected to disseminate the knowledge to other medical physicists in their countries.

07 ISOTOPE AND RADIATION SOURCES↗

MO-DE-BRA-01: Flipped Physics Courses Within a Radiologic Technologist Program: Video Production and Long Term Outcomes

Purpose: To determine if the flipped class format has an effect on examination results for a radiologic technologist (RT) program and discuss benefits from creating video resources. Methods: From 2001–2015, students had taken both a radiological physics and quality control (QC) class as a part of their didactic training. In 2005/2006, the creation of videos of didactic lectures and QC test demonstrations allowed for a flip where content was studied at home while exercises and reviews were done in-class. Final examinations were retrospectively reviewed from this timeframe. 12 multiple choice physics questions (MCP) and 5 short answer QC questions (SAQC) were common to pre and post flip exams. The RT program’s ARRT exam scores were also obtained and compared to national averages. Results: In total, 36 lecture videos and 65 quality control videos were created for the flipped content. Data was ∼2.4GB and distributed to students via USB or CD media. For MCP questions, scores improved by 7.9% with the flipped format and significance (Student’s t-test, p<0.05) was found for 3 of the 12 questions. SAQC questions showed improvement by 14.6% and significance was found for 2 of the 5 questions. Student enrollment increased from ∼14 (2001–2004) to ∼23 students (2005–15). Content was continuously added post-flip due to the efficiency of delivery. The QC class in 2003 covered 45 test setups in-class while 65 were covered with video segments in 2014. Flipped materials are currently being repurposed. In 2015, this video content was restructured into an ARRT exam review guide and in 2016, the content was reorganized for fluoroscopy training for physicians. Conclusion: We believe that flipped classes can improve efficiency of content delivery and improve student performance even with an increase in class size. This format allows for flexibility in learning as well as re-use in multiple applications.

07 ISOTOPE AND RADIATION SOURCES↗

MO-DE-BRA-05: EUTEMPE-RX: Combining E-Learning and Face-To-Face Training to Build Expert Knowledge, Skills and Competences for Medical Physicists in Diagnostic and Interventional Radiology

Purpose: In 2013, the EURATOM authorities of the European Commission decided to support the Horizon2020 project submission ‘EUTEMPE-RX’ that aimed for a new set of course modules to train medical physicists in diagnostic and interventional radiology to expert level with small group deep learning. Each module would consist of 2 phases: an e-learning and a face-to-face phase, each phase requiring typically 40h of participant time. Methods: The European Federation (EFOMP) and 13 European partners, all of them selected for their excellent scientific and/or educational skills, led the 12 course modules. A quality manual ensured the quality of course content and organization. Educational workshops familiarized the teachers with e-learning techniques and methods for assessment. Content was set in accordance with the EC document RP174 that lists learning outcomes in terms of knowledge, skills and competences (KSCs) for different specialties and levels of medical physics. Surveys for stake holder satisfaction were prepared. Results: Today the course modules are being realized. The modules cover most of the KSCs in RP174 document. Teachers have challenged the participants with unique tasks: case studies in medical physics leadership, Monte Carlo simulation of a complete x-ray imaging chain, development of a task specific QA protocol, compilation of optimization plans, simulation tasks with anthropomorphic breast models, etc. Participants undertook practical sessions in modern hospitals and visited a synchrotron facility, a calibration lab, screening organizations, etc. Feedback form quality surveys was very positive and constructive. A sustainability plan has been worked out. Conclusion: The modules have enabled the participants to develop their KSCs and cope with challenges in medical physics. The sustainability plan will be implemented to continue the unique combined e-learning and face to face training at high level training in diagnostic and interventional radiology also beyond Europe. The EUTEMPE-RX project is funded by the Horizon2020 - EURATOM program of the European Commission.

60 APPLIED LIFE SCIENCES↗

Radiological Staging for Distant Metastases in Breast Cancer Patients with Confirmed Local and/or Locoregional Recurrence: How Useful are Current Guideline Recommendations?

Background: Breast cancer patients with local and/or locoregional recurrence (LR) are at higher risk of developing distant metastases (DM) at a later time. Once LR has been confirmed, some international interdisciplinary guidelines recommend performing radiological examinations for DM to determine the course of further therapy (curative or palliative approach). This study analyzed the metastatic patterns of patients with LR with particular regard to the frequency of concurrent diagnosis of LR and DM; in other words: are radiological staging procedures actually justified for DM at the time of diagnosis of LR? Methods: This study included all patients (n = 1368) who were diagnosed and treated for nonmetastatic breast cancer (Stage I–III) at the University Women’s Hospital Basel, Switzerland between 1990 and 2009. Results: In 137 patients, LR was diagnosed without a history of DM: in-breast/thoracic wall only, n = 90 (65.7%); involvement of axillary/supra-/infraclavicular lymph nodes, n = 47 (34.3%). DM was found at the time of diagnosis of LR in 44 patients (32.1%). Concurrent diagnosis of LR and DM occurred significantly more often in patients with lymph node recurrence compared with those with in-breast/chest wall recurrence (48.9% vs. 23.3%; p = 0.004). Conclusions: Approximately one-third of patients with a LR had synchronous DM at the time of their local/locoregional event. For this reason, routine systemic staging imaging at the time of LR should be an absolute requirement for planning further therapy. Confirmation of DM may spare the patients radical surgical interventions with questionable impact on survival in the face of an incurable disease.

62 RADIOLOGY AND NUCLEAR MEDICINE↗