Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADIATIONS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Differential Mobility Spectrometry-Mass Spectrometry (DMS-MS) in Radiation Biodosimetry: Rapid and High-Throughput Quantitation of Multiple Radiation Biomarkers in Nonhuman Primate Urine

High-throughput methods to assess radiation exposure are a priority due to concerns that include nuclear power accidents, the spread of nuclear weapon capability, and the risk of terrorist attacks. Metabolomics, the assessment of small molecules in an easily accessible sample, is the most recent method to be applied for the identification of biomarkers of the biological radiation response with a useful dose-response profile. Profiling for biomarker identification is frequently done using an LC-MS platform which has limited throughput due to the time-consuming nature of chromatography. We present here a chromatography-free simplified method for quantitative analysis of seven metabolites in urine with radiation dose-response using urine samples provided from the Pannkuk et al. (2015) study of long-term (7-day) radiation response in nonhuman primates (NHP). The stable isotope dilution (SID) analytical method consists of sample preparation by strong cation exchange-solid phase extraction (SCX-SPE) to remove interferences and concentrate the metabolites of interest, followed by differential mobility spectrometry (DMS) ion filtration to select the ion of interest and reduce chemical background, followed by mass spectrometry (overall SID-SPE-DMS-MS). Since no chromatography is used, calibration curves were prepared rapidly, in under 2 h (including SPE) for six simultaneously analyzed radiation biomarkers. The seventh, creatinine, was measured separately after 2500× dilution. Creatinine plays a dual role, measuring kidney glomerular filtration rate (GFR), and indicating kidney damage at high doses. The current quantitative method using SID-SPE-DMS-MS provides throughput which is 7.5 to 30 times higher than that of LC-MS and provides a path to pre-clinical radiation dose estimation. .

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Radiation Therapy for Primary Cutaneous Anaplastic Large Cell Lymphoma: An International Lymphoma Radiation Oncology Group Multi-institutional Experience

Purpose: To collect response rates of primary cutaneous anaplastic large cell lymphoma, a rare cutaneous T-cell lymphoma, to radiation therapy (RT), and to determine potential prognostic factors predictive of outcome. Methods and Materials: The study was a retrospective analysis of patients with primary cutaneous anaplastic large cell lymphoma who received RT as primary therapy or after surgical excision. Data collected include initial stage of disease, RT modality (electron/photon), total dose, fractionation, response to treatment, and local recurrence. Radiation therapy was delivered at 8 participating International Lymphoma Radiation Oncology Group institutions worldwide. Results: Fifty-six patients met the eligibility criteria, and 63 tumors were treated: head and neck (27%), trunk (14%), upper extremities (27%), and lower extremities (32%). Median tumor size was 2.25 cm (range, 0.6-12 cm). T classification included T1, 40 patients (71%); T2, 12 patients (21%); and T3, 4 patients (7%). The median radiation dose was 35 Gy (range, 6-45 Gy). Complete clinical response (CCR) was achieved in 60 of 63 tumors (95%) and partial response in 3 tumors (5%). After CCR, 1 tumor recurred locally (1.7%) after 36 Gy and 7 months after RT. This was the only patient to die of disease. Conclusions: Primary cutaneous anaplastic large cell lymphoma is a rare, indolent cutaneous lymphoma with a low death rate. This analysis, which was restricted to patients selected for treatment with radiation, indicates that achieving CCR was independent of radiation dose. Because there were too few failures (<2%) for statistical analysis on dose response, 30 Gy seems to be adequate for local control, and even lower doses may suffice.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The Importance of Radiation Dose to the Atherosclerotic Plaque in the Left Anterior Descending Coronary Artery for Radiation-Induced Cardiac Toxicity of Breast Cancer Patients?

Radiation-induced acute coronary events (ACEs) may occur as a treatment-related late adverse effect of breast cancer (BC) radiation. However, the underlying mechanisms behind this radiation-induced cardiac disease remain to be determined. The objective of this study was to test the hypothesis that radiation dose to calcified atherosclerotic plaques in the left anterior descending coronary artery (LAD) is a better predictor for ACEs than radiation dose to the whole heart or left ventricle in patients with BC treated with radiation therapy.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Surface shortwave aerosol radiative forcing during the Atmospheric Radiation Measurement Mobile Facility deployment in Niamey, Niger

This study presents ground-based remote sensing measurements of aerosol optical properties and corresponding shortwave surface radiative effect calculations for the deployment of the Atmospheric Radiation Measurement (ARM) Program’s Mobile Facility (AMF) to Niamey, Niger during 2006. Aerosol optical properties including aerosol optical depth (AOD), single scattering albedo (SSA), and asymmetry parameter (AP) were derived from multi-filter rotating shadowband radiometer (MFRSR) measurements during the two dry seasons (Jan-Apr and Oct-Dec) at Niamey. The vertical distribution of aerosol extinction was derived from the collocated micropulse lidar (MPL). The aerosol optical properties and vertical distribution of extinction varied significantly throughout the year, with higher AOD, lower SSA, and deeper aerosol layers during the Jan-Apr time period, when biomass burning aerosol layers were more frequent. Using the retrieved aerosol properties and vertical extinction profiles, broadband shortwave surface fluxes and atmospheric heating rate profiles were calculated. Corresponding calculations with no aerosol were used to estimate the aerosol direct radiative effect at the surface. Comparison of the calculated surface fluxes to observed fluxes for non-cloudy periods indicated that the remote sensing retrievals provided a reasonable estimation of the optical properties, with mean differences between calculated and observed fluxes of less than 5 W/m2 and RMS differences less than 25 W/m2. Sensitivity tests for a particular case study showed that the observed fluxes could be matched with variations of < 10% in the inputs to the radiative transfer model. We estimated the daily-averaged aerosol radiative effect at the surface by subtracting the clear calculations from the aerosol calculations. The average daily SW aerosol radiative effect over the study period was -27 W/m2, which is comparable to values estimated from satellite data and from climate models with sophisticated dust parameterizations.

09 BIOMASS FUELS↗

Investigation of Arctic Cloud Properties and Surface Radiation Based on MOSAiC Shipborne Observations

The Arctic is rapidly changing due to changes of the Earth system. This study investigates cloud fraction, phase partition, cloud type, and their relationships with surface radiation based on yearlong shipborne observations in the Arctic regions. The Multidisciplinary drifting Observatory for the Study of Arctic Climate (MOSAiC) campaign provided lidar and radar observations of cloud microphysical properties and surface shortwave (SW) and longwave (LW) radiation. Cloud and radiative properties were examined at daily and monthly resolutions in four seasons. Low clouds were found to be most prevalent throughout the year, followed by deep clouds. The ice phase is the dominant phase except for summer (June–August). Liquid and mixed phases show more significant monthly and annual mean radiative effects in SW and LW than the ice phase. The clouds show net warming effects due to LW heating in most months, while the SW cooling effects of clouds become more dominant for July and August. The cloud and radiation observations from MOSAiC were used to evaluate simulations of the atmospheric component of the Energy Exascale Earth System Model version 2. The simulations show large overestimations of the liquid and mixed phases in the Arctic regions from February to September. The simulations also underestimate the percentages of low clouds and overestimate the percentages of deep clouds throughout the year. Altogether, this work provides a unique analysis of cloud and radiation properties based on high-resolution shipborne observations, which can be used to assist future model evaluation and development.

58 GEOSCIENCES↗

MO-F-16A-06: Implementation of a Radiation Exposure Monitoring System for Surveillance of Multi-Modality Radiation Dose Data

Purpose: We have implemented a commercially available Radiation Exposure Monitoring System (REMS) to enhance the processes of radiation dose data collection, analysis and alerting developed over the past decade at our sites of practice. REMS allows for consolidation of multiple radiation dose information sources and quicker alerting than previously developed processes. Methods: Thirty-nine x-ray producing imaging modalities were interfaced with the REMS: thirteen computed tomography scanners, sixteen angiography/interventional systems, nine digital radiography systems and one mammography system. A number of methodologies were used to provide dose data to the REMS: Modality Performed Procedure Step (MPPS) messages, DICOM Radiation Dose Structured Reports (RDSR), and DICOM header information. Once interfaced, the dosimetry information from each device underwent validation (first 15–20 exams) before release for viewing by end-users: physicians, medical physicists, technologists and administrators. Results: Before REMS, our diagnostic physics group pulled dosimetry data from seven disparate databases throughout the radiology, radiation oncology, cardiology, electrophysiology, anesthesiology/pain management and vascular surgery departments at two major medical centers and four associated outpatient clinics. With the REMS implementation, we now have one authoritative source of dose information for alerting, longitudinal analysis, dashboard/graphics generation and benchmarking. REMS provides immediate automatic dose alerts utilizing thresholds calculated through daily statistical analysis. This has streamlined our Closing the Loop process for estimated skin exposures in excess of our institutional specific substantial radiation dose level which relied on technologist notification of the diagnostic physics group and daily report from the radiology information system (RIS). REMS also automatically calculates the CT size-specific dose estimate (SSDE) as well as provides two-dimensional angulation dose maps for angiography/interventional procedures. Conclusion: REMS implementation has streamlined and consolidated the dosimetry data collection and analysis process at our institutions while eliminating manual entry error and providing immediate alerting and access to dosimetry data to both physicists and physicians. Brent Stewart has funded research through GE Healthcare.

60 APPLIED LIFE SCIENCES↗

Measurement of the radiative decay rate and energy of the metastable (2s{sup 2}2p{sub 1/2}{sup 5}3s{sub 1/2}){sub (J=0)} level in Fe xvii

Measurements at the Livermore electron beam ion trap have been performed in order to infer the energy and the radiative lifetime of the (1s{sup 2}2s{sup 2}2p{sub 1/2}{sup 5}3s{sub 1/2}){sub J=0} level in the Fe xvii spectrum. This is the longest-lived level in the neonlike iron ion, and its radiative decay produces the Fe xvii line at 1153 Å, feeding the population of the (1s{sup 2}2s{sup 2}2p{sub 3/2}{sup 5}3s{sub 1/2}){sub J=1} upper level of one of the most prominent lines in the Fe xvii L-shell X-ray spectrum, commonly dubbed 3G. In the presence of a strong (⩾ few kG) magnetic field, the (1s{sup 2}2s{sup 2}2p{sub 1/2}{sup 5}3s{sub 1/2}){sub J=0} level has a finite probability to decay directly to the (1s{sup 2}2s{sup 2}2p{sup 6}){sub J=0} neonlike ground level via the emission of an L-shell X-ray. Our measurements allow us to observe this X-ray line in the Fe xvii L-shell spectrum and from it to infer the radiative rate for the magnetic dipole decay of the (1s{sup 2}2s{sup 2}2p{sub 1/2}{sup 5}3s{sub 1/2}){sub J=0} level to the (1s{sup 2}2s{sup 2}2p{sub 3/2}{sup 5}3s{sub 1/2}){sub J=1}. Our result of (1.45±0.15)×10{sup 4} s{sup −1} is in agreement with predictions. We have also measured the wavelength of the associated X-ray line to be 16.804 ± 0.002 Å, which means that the line is displaced 1.20 ± 0.05 eV from the neighboring (2s{sup 2}2p{sub 1/2}{sup 5}3s{sub 1/2}){sub J=1}→(2s{sup 2}2p{sup 6}){sub J=0} transition, commonly labeled 3F. From our measurement, we infer 5950570 ± 710 cm{sup −1} for the energy of the (1s{sup 2}2s{sup 2}2p{sub 1/2}{sup 5}3s{sub 1/2}){sub J=0} level.

79 ASTRONOMY AND ASTROPHYSICS↗

Dose, LET, time and strain dependence of radiation-induced 53BP1 foci in 15 mouse strains ex vivo and associations to in vivo radiation susceptibility

We present a comparative analysis on the repair of radiation-induced DNA damage ex vivo in 15 strains of mice, including 5 inbred reference strains and 10 collaborative-cross strains, of both sexes. Non-immortalized primary skin fibroblasts derived from 76 mice were subjected to both low- and high-LET radiation (0.1, 1 and 4 Gy of X rays; 1.1 and 3 particles/100μm2 of 350 MeV/n 40Ar and 600 MeV/n 56Fe). Automated image quantification of 53BP1 radiation-induced foci (RIF) during the first 4-48 h post-irradiation was performed as a function of dose and LET. Similarly to what we had previously reported for immortalized human cell lines [1], we observed a saturation of RIF number with dose at 4h post-irradiation, with more RIF/Gy for lower LET (X rays and 40Ar) compared to 56Fe. However at later time points (24h and above), the trend was inverted with more RIF/Gy for higher LET. Our data suggest that multiple DSBs cluster into RIF: as the linear density of DSBs increases with LET, so does the probability of having more DSBs per RIF, which makes it more difficult for cells to fully resolve high-LET-induced RIF, explaining the hypersensitivity to high-LET radiation despite a low number of RIF. Taking into account the amount of clustering at a given dose and LET, but also the kinetics of DNA damage repair, we introduced a novel mathematical formalism to evaluate the number of remaining RIF over time. We showed that the newly introduced kinetic metrics can be used as surrogate biomarkers for in vivo radiation toxicity, with potential applications in radiotherapy and human space exploration. In particular, we observed an association between the repairable fraction of RIF measured in vitro and survival levels of immune cells collected from irradiated mice. Moreover, the speed of DNA damage repair correlated with spontaneous cancer incidence data collected from the Mouse Tumor Biology database, suggesting a relationship between the efficiency of DSB repair after irradiation and cancer risk. In addition to the efficacy of repair and persistent RIF levels, even the amount of spontaneous foci without irradiation was shown to be strain dependent, indicating that these phenotypes are at least partially driven by genetics, and supporting their potential as indicators of individual radiation sensitivity. [1] Neumaier, T., et al., PNAS, 2012 (8) 109:443

Radiation, DNA damage, repair kinetics↗

INCREASING THE TRANSPARENCY AND REPRODUCIBILITY OF SPACE RADIATION SCIENCE: THE RADIATION BIOLOGY ONTOLOGY

Among the primary objectives of the Open/Open-Source Science paradigm are making scientific investigation data transparent and results reproducible [1], objectives shared by the FAIR principles [2]. To accomplish this, the conceptual framework that includes all the investigation objects needs to be accurately captured and communicated to all data consumers. A large part of this requires using metadata standards to annotate data collected. These standards should be readily accessible, informed by scientific community consensus and sufficiently specific to encompass all of the important aspects of the investigation. Starting in 2020 we have been co-leading an open consortium to develop a new metadata standard, the Radiation Biology Ontology (RBO), through the Open Biological and Biomedical Ontologies (OBO) Foundry [3]. We began by transforming many of the terms from the National Council on Radiation Protection and Measurement into concepts that can be formally related to existing OBO Foundry classes or attributes. We then identified and imported into the RBO existing OBO Foundry classes that have obvious relevance for radiation biomedicine (for example, concepts from the Environment Ontology that describe radiative processes, and concepts from the Gene Ontology dealing with molecular and cellular responses to radiation). Finally, we scrutinized datasets from investigations of radiation effects held in NASA GeneLab and LSDA repositories and added additional classes, instances, and attributes into the RBO that should be used to annotate these data. We developed the RBO using the open-source tools of GitHub and publish the RBO periodically through the NIH/NCBI BioPortal website, so systems worldwide can leverage the knowledge it contains [4]. This initial phase of concept modeling has yielded an RBO that at present has more than 300 declared concepts, with more than 3500 additional concepts imported from other OBO Foundry ontologies. While this first phase has focused on concepts for annotating samples, environments, exposures, and measurements, the next phase will center on supporting annotation of results and findings, such as concept models of molecular, cellular and tissue effects. The value of the RBO will be determined in part by our ability to engage the community in its development, and we have established a Radiobiology Informatics Consortium with unrestricted membership as the owner of the RBO in order to encourage investigators, system owners and other to join in this effort. Anyone can report issues or request new concept modeling or other features directly on GitHub. By using the BioPortal application programming interface, systems can pose dynamic queries to the latest version of the RBO for information on individual classes or entire hierarchies; this design eliminates the need for systems to be updated in order to use newer versions of the RBO. We hope to contribute to the advancement of open radiobiological science through the continued, open development of the RBO, that will provide more precise, machine-interpretable descriptions of investigations, as well as support data meta-analysis through machine learning or other artificial intelligence methods.

knowledge↗

Efficient smoothed particle radiation hydrodynamics I: Thermal radiative transfer

This work presents efficient solution techniques for radiative transfer in the smoothed particle hydrodynamics discretization. Two choices that impact efficiency are how the material and radiation energy are coupled, which determines the number of iterations needed to converge the emission source, and how the radiation diffusion equation is solved, which must be done in each iteration. The coupled material and radiation energy equations are solved using an inexact Newton iteration scheme based on nonlinear elimination, which reduces the number of Newton iterations needed to converge within each time step. During each Newton iteration, the radiation diffusion equation is solved using Krylov iterative methods with a multigrid preconditioner, which abstracts and optimizes much of the communication when running in parallel. The code is verified for an infinite medium problem, a one-dimensional Marshak wave, and a two and three-dimensional manufactured problem, and exhibits first-order convergence in time and second-order convergence in space. For these problems, the number of iterations needed to converge the inexact Newton scheme and the diffusion equation is independent of the number of spatial points and the number of processors.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Radiation burnthrough measurements to infer opacity at conditions close to the solar radiative zone–convective zone boundary

Recent measurements at the Sandia National Laboratory of the x-ray transmission of iron plasma have inferred opacities much higher than predicted by theory, which casts doubt on modeling of iron x-ray radiative opacity at conditions close to the solar convective zone-radiative zone boundary. An increased radiative opacity of the solar mixture, in particular iron, is a possible explanation for the disagreement in the position of the solar convection zone-radiative zone boundary as measured by helioseismology and predicted by modeling using the most recent photosphere analysis of the elemental composition. In this report we present data from radiation burnthrough experiments, which do not support a large increase in the opacity of iron at conditions close to the base of the solar convection zone and provide a constraint on the possible values of both the mean opacity and the opacity in the x-ray range of the Sandia experiments. The data agree with opacity values from current state-of-the-art opacity modeling using the CASSANDRA opacity code.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Spectra, temporal structure, and angular directivity of laser radiation of a Yb:YAG crystal and ytterbium glass pumped by low-coherence radiation from a F{sub 2}{sup +}:LiF colour centre laser

By focusing radiation from a F{sub 2}{sup +}:LiF colour centre laser (emitting in the range from 0.89 to 0.95 {mu}m) on plates of a Yb:YAG crystal with the 20% concentration of Yb and of ytterbium glass with the 10% concentration of Yb, we observed nanosecond radiation pulses of Yb{sup 3+} ions in the spectral region from 1.00 to 1.06 {mu}m with the spectral width up to 20 nm in Yb:YAG and up to 50 nm in the ytterbium glass. Lasing appeared in the active medium in the region of excitation of the SBS of pump radiation with a diameter less than 200 {mu}m. The angular divergence of the broadband laser radiation (10{sup -3}-10{sup -4} rad) was one-two orders of magnitude smaller than the diffraction limit. The mechanism of generation of short broadband high-directional laser pulses in the spatial structure of thin layers with inversion produced in the region of propagation of an intense acoustic wave in the medium is discussed. The interpretation of experimental data on the angular divergence of radiation is based on a new concept of the spatial distribution of the electromagnetic field of a photon not in the form of a travelling wave but with the field structures located in fixed positions along the propagation direction. The features of the temporal picture and narrowband lasing spectra of Yb:YAG and ytterbium glass in a resonator upon relaxation of the SBS excitation region in the active medium are considered. The possibility of diagnostics of medium parameters using the shift of spectra of the lasing at the resonator modes in different sites of the SBS excitation region is discussed. (active media. lasers)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Determining the parameters of the laser radiation intensity limiter based on a time-dependent equation of radiative transfer in a nonlinear medium

The effect of the radiation intensity limitation is described using the time-dependent radiative transfer equation taking into account the nonlinearity of the working material of the limiter, which makes it possible to abstract from specific microscopic mechanisms of interaction of radiation with matter. An expression is presented which describes both the deformation of the shape of the laser pulse propagating through a nonlinear medium and the output characteristic (dependence of the output energy on the energy of incident radiation) of the limiter at a known dependence of the absorption coefficient on the laser pulsed radiation intensity with a given pulse shape. A functional equation is derived to determine the dependence of the absorption coefficient on the intensity from the experimental output characteristic, which allows one to predict the limiter properties for different thicknesses of the working medium, as well as to effectively compare limiters of different types. (nonlinear optical phenomena)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Review of Hybrid (Deterministic/Monte Carlo) Radiation Transport Methods, Codes, and Applications at Oak Ridge National Laboratory

This paper provides a review of the hybrid (Monte Carlo/deterministic) radiation transport methods and codes used at the Oak Ridge National Laboratory and examples of their application for increasing the efficiency of real-world, fixed-source Monte Carlo analyses. The two principal hybrid methods are (1) Consistent Adjoint Driven Importance Sampling (CADIS) for optimization of a localized detector (tally) region (e.g., flux, dose, or reaction rate at a particular location) and (2) Forward Weighted CADIS (FW-CADIS) for optimizing distributions (e.g., mesh tallies over all or part of the problem space) or multiple localized detector regions (e.g., simultaneous optimization of two or more localized tally regions). The two methods have been implemented and automated in both the MAVRIC sequence of SCALE 6 and ADVANTG, a code that works with the MCNP code. As implemented, the methods utilize the results of approximate, fast-running 3-D discrete ordinates transport calculations (with the Denovo code) to generate consistent space- and energy-dependent source and transport (weight windows) biasing parameters. These methods and codes have been applied to many relevant and challenging problems, including calculations of PWR ex-core thermal detector response, dose rates throughout an entire PWR facility, site boundary dose from arrays of commercial spent fuel storage casks, radiation fields for criticality accident alarm system placement, and detector response for special nuclear material detection scenarios and nuclear well-logging tools. Substantial computational speed-ups, generally O(102-4), have been realized for all applications to date. This paper provides a brief review of the methods, their implementation, results of their application, and current development activities, as well as a considerable list of references for readers seeking more information about the methods and/or their applications.

97 MATHEMATICS AND COMPUTING↗

PRD3000: A novel Personnel Radiation Detector with Radiation Exposure Monitoring

PRD3000{sup TM} is a novel Personal Radiation Detector (PRD) with personnel radiation dose exposure monitoring. It is intended for First Responders, Law Enforcement, Customs Inspectors protecting critical infrastructures for detecting unexpected radioactive sources, who also need real time Hp(10) dose equivalent information. Traditional PRD devices use scintillator materials instrumented through either a photomultiplier tube or a photodiode photodetector. While the former is bulky and sensitive to magnetic fields, the latter has to compromise radiation sensitivity and energy threshold given its current noise per unit of photo-detection surface. Recently, solid state photodetectors (SiPM), based on arrays of Geiger operated diodes, have emerged as a scalable digital photodetector for photon counting. Their strong breakdown voltage temperature dependence (on the order of tens of milli-volts per K) has however limited their use for portable instruments where strong temperature gradients can be experienced, and limited power is available to temperature stabilize. The PRD3000 is based on the industry standard DMC3000 active dosimeter that complies with IEC 61526 Ed. 3 and ANSI 42.20 for direct reading personal dose equivalent meters and active personnel radiation monitors. An extension module is based on a CsI(Tl) scintillator readout by a temperature compensated SiPM. Preliminary nuclear tests combined with a measured continuous operation in excess of 240 hours from a single AAA battery cell indicate that the PRD3000 complies with the IEC 62401 Ed.2 and ANSI 42.32 without sacrificing battery life time. We present a summary of the device test results, starting with performance stability over a temperature range of - 20 deg. C to 50 deg. C, false alarm rates and dynamic response time. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗