Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “RADAR SYSTEM”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

STS-99 Countdown Status Briefing

The primary objective of the STS-99 mission was to complete high resolution mapping of large sections of the Earth's surface using the Shuttle Radar Topography Mission (SRTM), a specially modified radar system. This radar system produced unrivaled 3-D images of the Earth's Surface. The mission was launched at 12:31 on February 11, 2000 onboard the space shuttle Endeavour. This tape presents a pre-launch briefing for the press held on Jan. 28, 2000. Statements were given by Doug Lyons, Shuttle Test Director; Scott Higginbotham, STS-99 Payload Director and Ed Priselac, Shuttle Weather Officer. Doug Lyons reported on the checkout of the equipment. Scott Higgenbotham reviewed the steps required to assemble and test the SRTM instrumentation and equipment. Ed Priselac gave the weather forecast for the expected launch day. The questions concerned a possible problem with a part onboard the shuttle and the likely impact this might have on the launch.

Source record↗

STS-99 Countdown Status Briefing

The primary objective of the STS-99 mission was to complete high resolution mapping of large sections of the Earth's surface using the Shuttle Radar Topography Mission (SRTM), a specially modified radar system. This radar system produced unrivaled 3-D images of the Earth's Surface. The mission was launched at 12:31 on February 11, 2000 onboard the space shuttle Endeavour. This tape shows a pre-launch briefing. The panel members are George Diller, NASA Public Affairs; Scott Higginbotham, SRTM Payload Manager; Steve Altemus, NASA Test Director; and Ed Priselac, Meteorologist. The briefing opens with an announcement by Mr Diller that there were no further developments with the engine problems, and requests that questions about that issue be held for another press briefing. Steve Altemus summarized the situation and the steps to be taken. Scott Higginbotham reported that there were no problems with the mission hardware. Ed Priselac reported favorable weather for tanking and launch, and at emergency landing sites.

Source record↗

STS-99 / Endeavour SRTM Science Briefing and Applications from JSC

The primary objective of the STS-99 mission was to complete high resolution mapping of large sections of the Earth's surface using the Shuttle Radar Topography Mission (SRTM), a specially modified radar system. This radar system produced unrivaled 3-D images of the Earth's Surface. This videotape shows a science press briefing. The panel members are Michael Kobrick, the SRTM Project Scientist at JPL; Thomas Henning, SRTM Program Manager at the National Imagery and Mapping Agency; Diane Evans, the Director of the Earth Sciences Program at NASA; and Marian Werner, XSAR Project Manager for the DLR, Deutschen Zentrum fur Luft- und Raumfahrt, Germany's National Aerospace Research Center. Michael Kobrick explained the mechanics of interferometric measurements of the Earth. He explained and demonstrated with a scale model the deployable mast's use. He also explained the importance of the attitude and orbit determination avionics. A brief animated video showing how four beams would give a 225 km wide swath of the Earth topography was viewed. Thomas Henning discussed some of the usage of the digital terrain elevation data for flood relief planning, cell phone station placement, military planning for command and control centers, and flight simulation. He explained that public access to the most precise data would be limited. Diane Evans described data usage in flood prediction, earthquake fault identification and archeology. Marian Werner described the German and Italian input to the project. The questions from the press concerned the time to process this data, and the reasons for the limited access to the more precise data.

Source record↗

The Earth Observing System Synthetic Aperture Radar (EOS SAR) mission

The EOS SAR mission under consideration as one element of the mission to planet earth, which will provide a long duration radar observing system with multipolarization and multifrequency capability, is presented. The payload consists of three synthetic aperture radar systems; a C-band radar with dual polarization, an L-band radar with quadruple polarization, and an X-band radar with dual polarization. Each radar system will be of the phased-array type, will have variable resolutions and swath widths and will be capable of steering the beam electronically in elevation.

Wellman, John B.↗

Real-Time Vehicle-Mounted Multistatic Ground Penetrating Radar Imaging System for Buried Object Detection

A multistatic ground penetrating radar system is described, capable of real-time imaging and object detection. The radar consists of 16 transmitter and receiver pairs mounted across the front of a vehicle. The transmitters operate sequentially with all receivers activated for each transmit pulse. The resulting frame of 256 multistatic time signals is processed into an image using a tomographic reconstruction technique. In this paper we describe the system architecture, signal conditioning, and reconstruction algorithm for producing a sequence of images in real time as the vehicle travels across the ground. We demonstrate a robust image post-processing method that separates the bright spot corresponding to the dominant buried object in an image frame from the background. This is essential before calculating an energy-based statistic for automatic detection of buried objects. This spot ratio detection statistic, based on energy both inside and outside the spot, is shown to be not only more stationary than spot energy (i.e. mostly free of localized trends due to changing ground conditions), but also more powerful as a detection statistic. Finally, we demonstrate that multistatic imaging significantly improves the detection performance over more conventional monostatic array processing.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monitoring internal organ motion with continuous wave radar in CT

Purpose: To avoid motion artifacts in medical imaging or to minimize the exposure of healthy tissues in radiation therapy, medical devices are often synchronized with the patient's respiratory motion. Today's respiratory motion monitors require additional effort to prepare the patients, e.g., mounting a motion belt or placing an optical reflector on the patient's breast. Furthermore, they are not able to measure internal organ motion without implanting markers. An interesting alternative to assess the patient's organ motion is continuous wave radar. The aim of this work is to design, implement, and evaluate such a radar system focusing on application in CT.Methods: The authors designed a radar system operating in the 860 MHz band to monitor the patient motion. In the intended application of the radar system, the antennas are located close to the patient's body inside the table of a CT system. One receive and four transmitting antennas are used to avoid the requirement of exact patient positioning. The radar waves propagate into the patient's body and are reflected at tissue boundaries, for example at the borderline between muscle and adipose tissue, or at the boundaries of organs. At present, the authors focus on the detection of respiratory motion. The radar system consists of the hardware mentioned above as well as of dedicated signal processing software to extract the desired information from the radar signal. The system was evaluated using simulations and measurements. To simulate the radar system, a simulation model based on radar and wave field equations was designed and 4D respiratory-gated CT data sets were used as input. The simulated radar signals and the measured data were processed in the same way. The radar system hardware and the signal processing algorithms were tested with data from ten volunteers. As a reference, the respiratory motion signal was recorded using a breast belt simultaneously with the radar measurements.Results: Concerning the measurements of the test persons, there is a very good correlation (ρ= 0.917) between the respiratory motion phases received by the radar system and the external motion monitor. Our concept of using an array of transmitting antennas turned out to be widely insensitive to the positioning of the test persons. A time shift between the respiratory motion curves recorded with the radar system and the motion curves from the external respiratory monitor was observed which indicates a slight difference between internal organ motion and motion detected by the external respiratory monitor. The simulations were in good accordance with the measurements.Conclusions: A continuous wave radar operating in the near field of the antennas can be used to determine the respiratory motion of humans accurately. In contrast to trigger systems used today, the radar system is able to measure motion inside the body. If such a monitor was routinely available in clinical CT, it would be possible optimizing the scan start with respect to the respiratory state of the patient. Breathing commands would potentially widely be avoided, and as far as uncooperative patients or children are concerned, less sedation might be necessary. Further applications of the radar system could be in radiation therapy or interventional imaging for instance.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

New pulsing technique may improve radar ranging systems

Mode of operation for radar ranging system based on ringing frequencies is described. Methods for measuring range and range rate are discussed. Mathematical model is included to describe ringing frequency. Application to acoustic sounding devices is proposed.

Gowdey, M. V.↗

Instantaneous ultra-wideband sensing using frequency-domain channelization

A radar system wherein a radar return is channelized by frequency into a plurality of channels, and each of the channels is sampled by a respective analog-to-digital converter that has a sampling rate less than the Nyquist rate of the radar return. The digitally sampled channel signals are Fourier transformed into the frequency domain, where each of the frequency-domain channel signals is matched-filtered according to a respective partial matched filter. The channel signals are then transformed back to the time domain, whereupon they are added together to generate the impulse response of the radar system responsive to the radar return.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Digital Beamforming Interferometry

Airborne or spaceborne Syntheic Aperture Radar (SAR) can be used in a variety of ways, and is often used to generate two dimensional images of a surface. SAR involves the use of radio waves to determine presence, properties, and features of extended areas. Specifically, radio waves are 10 transmitted in the presence of a ground surface. A portion of the radio wave's energy is reflected back to the radar system, which allows the radar system to detect and image the surface. Such radar systems may be used in science applications, military contexts, and other commercial applications.

Rincon, Rafael F.↗

Feature discrimination and detection probability in synthetic aperture radar imaging system

Images obtained using synthetic aperture radar (SAR) systems can only represent the intensities of resolution cells in the scene of interest probabilistically since radar receiver noise and Rayleigh scattering of the transmitted radiation are always present. Consequently, when features to be identified differ only by their contribution to the mean power of the radar return, discrimination can be treated by detection theory. In this paper, we develop a 'sufficient statistic' for discriminating between competing features and compare it with some suboptimal methods frequently used. Discrimination is measured by probability of detection error and depends on number of samples or 'looks', signal-to-noise ratio (SNR), and ratio of mean power returns from the competing features. Our results show discrimination and image quality rapidly saturate with SNR (very small improvement for SNR not less than 10 dB) but continue to improve with increasing number of looks.

Lipes, R. G.↗

Component and Circuit Performance Measurements for Coherent Radar - A Systems Perspective

A useful performance metric for Intelligence, Surveillance, and Reconnaissance (ISR) radar systems is the Impulse Response (IPR). This is true for a fidelity metric for the signal channel, as well as a stability measure across multiple pulses. The IPR represents performance with respect to both amplitude and phase modulations of the transfer function for components, circuits, subassemblies, and even the looped radar hardware. The proper IPR performance specification limits will depend on radar operating mode. Generally, it will be the intersection of the strictest requirements.

42 ENGINEERING↗

T/R Multi-Chip MMIC Modules for 150 GHz

Modules containing multiple monolithic microwave integrated-circuit (MMIC) chips have been built as prototypes of transmitting/receiving (T/R) modules for millimeter-wavelength radar systems, including phased-array radar systems to be used for diverse purposes that could include guidance and avoidance of hazards for landing spacecraft, imaging systems for detecting hidden weapons, and hazard-avoidance systems for automobiles. Whereas prior landing radar systems have operated at frequencies around 35 GHz, the integrated circuits in this module operate in a frequency band centered at about 150 GHz. The higher frequency (and, hence, shorter wavelength), is expected to make it possible to obtain finer spatial resolution while also using smaller antennas and thereby reducing the sizes and masses of the affected systems.

Samoska, Lorene A.↗

The SEASAT-A synthetic aperture radar design and implementation

The SEASAT-A synthetic aperture imaging radar system is the first imaging radar system intended to be used as a scientific instrument designed for orbital use. The requirement of the radar system is to generate continuous radar imagery with a 100 kilometer swath with 25 meter resolution from an orbital altitude of 800 kilometers. These requirements impose unique system design problems and a description of the implementation is given. The end-to-end system is described, including interactions of the spacecraft, antenna, sensor, telemetry link, recording subsystem, and data processor. Some of the factors leading to the selection of critical system parameters are listed. The expected error sources leading to degradation of image quality are reported as well as estimate given of the expected performance from data obtained during a ground testing of the completed subsystems.

Jordan, R. L.↗

The Seasat-A synthetic aperture radar design and implementation

The Seasat-A Synthetic Aperture Imaging Radar System is the first imaging radar system intended to be used as a scientific instrument designed for orbital use. The requirement of the radar system is to generate continuous radar imagery with a 100 kilometer swath with 25 meter resolution from an orbital altitude of 800 kilometers. These requirements impose unique system design problems and a description of the implementation will be given. The end-to-end data system will be described, including interactions of the spacecraft, antenna, sensor, telemetry link, recording subsystem, and data processor. Some of the factors leading to the selection of critical system parameters will be listed. The expected error sources leading to degradation of image quality will be described as well as estimates given of the expected performance from data obtained during ground testing of the completed subsystems.

Jordan, R.↗