Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “QUARTZ”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Vacuum tight quartz ampoule for Bridgman growth of crystals with interface demarcation

A growth ampoule for protecting the furnace lining and to prevent a change in the composition of the melt during growth of Pb-T-Te or Ge semiconductors doped with Ga is described. Mo foil is inserted into a quartz tube and sealed at the ends. A vacuum pumping system collapses the tube onto the foil. Spotwelded Mo wires lead in two directions from the collapsed section through quartz capillaries, one of which is also collapsed, on the wire, which provides a contact point for seeded growth of the semiconductor. The ampoule has been used for Bridgeman growth of crystals using a hot zone of 1150 C, with a temperature gradient of 240 C/m, and with current pulses up to 40 A/sq cm.

Crouch, R. K.↗

Optical contacting of quartz

The strength of the bond between optically contacted quartz surfaces was investigated. The Gravity Probe-B (GP-B) experiment to test the theories of general relativity requires extremely precise measurements. The quartz components of the instruments to make these measurements must be held together in a very stable unit. Optical contacting is suggested as a possible method of joining these components. The fundamental forces involved in optical contacting are reviewed and relates calculations of these forces to the results obtained in experiments.

Payne, L. L.↗

Temperature-controlled quartz crystal microbalance measurements on Space Transport System (STS-2)

The purpose of the Temperature-Controlled Quartz Crystal Microbalance (TQCM) system on STS-2 was to measure condensible molecular flux in the payload bay of the Space Shuttle as a function of temperature, direction, and time. Five quartz crystal microbalance sensors were located in the IECM to measure molecular adsorption in each of the Orbiter axes, +X (fore), -X (aft), +Y (starboard), -Y (port), and -Z (up, perpendicular to payload bay). The temperature of each sensor was controlled by a thermoelectric device so contamination could be measured as a function of four preset temperatures: +30, 0, -30, and -60 C. When orbital altitude was reached, the TQCM sensors began their orbital measuring cycle routine. The sensors were commanded to 80 C for 30 min, which was used as an initial clean-up. They were then stepped through a program of 2-nr collection periods at each temperature with a 30-min, 80 C period between each collection period. The collection periods progressed in descending order from +30 to -60 C and, then the cycle was repeated. Since the STS-2 orbital phase lasted approximately 53 hrs, the TQCM system completed four cycles and was in the fifth when the mission was terminated.

Fountain, J. A.↗

On-orbit frequency stability analysis of the GPS NAVSTAR-1 quartz clock and the NAVSTARs-6 and -8 rubidium clocks

An on-orbit frequency stability performance analysis of the GPS NAVSTAR-1 quartz clock and the NAVSTARs-6 and -8 rubidium clocks is presented. The clock offsets were obtained from measurements taken at the GPS monitor stations which use high performance cesium standards as a reference. Clock performance is characterized through the use of the Allan variance, which is evaluated for sample times of 15 minutes to two hours, and from one day to 10 days. The quartz and rubidium clocks' offsets were corrected for aging rate before computing the frequency stability. The effect of small errors in aging rate is presented for the NAVSTAR-8 rubidium clock's stability analysis. The analysis includes presentation of time and frequency residuals with respect to linear and quadratic models, which aid in obtaining aging rate values and identifying systematic and random effects. The frequency stability values were further processed with a time domain noise process analysis, which is used to classify random noise process and modulation type.

Mccaskill, T. B.↗

Production of Be-10 and Al-26 by cosmic rays in terrestrial quartz in situ and implications for erosion rates

Results of determinations of Be-10 and Al-26 produced by cosmic rays in situ in several terrestrial rock samples exposed at altitudes of 1-4 km are presented. The theoretical saturation values for these isotopes produced in quartz at the earth's surface are shown and discussed, and the expected isotope concentrations are considered in terms of a simple exosure history model which occurs without change in the altitude of the sample. The advantages of using Be-10 and Al-26 in this application, as opposed to C1-36, are discussed. The results demonstrate the feasibility of quantitatively measuring Be-10 and Al-26 produced in situ by cosmic rays in quartz and the possible applications of these isotopes as a pair for studying continental weathering/erosion processes.

Nishiizumi, K.↗

Advances in the development of piezoelectric quartz-crystal oscillators, hydrogen masers, and superconducting frequency standards

This paper describes recent research advances made in the development of radiation-hardened piezoelectric quartz oscillators, hydrogen masers, and superconducting oscillators, with emphasis placed on the principles involved in the operation of these oscillators and the factors affecting the operation. Particular attention is given to the radiation-susceptibility studies of quartz-crystal resonators, the hydrogen-maser relaxation process and noise sources, and low-phase-noise superconducting oscillators. Diagrams of these devices and performance graphs are included.

Suter, Joseph J.↗

Shock metamorphism of deformed quartz

The effect produced by shock loading (to peak pressures of 12 and 24) on deformed synthetic quartz containing a dislocation and abundant bubbles and small inclusions was investigated, and the relationships between preexisting dislocation density shock lamellae in the target material were examined. The resultant material was found to be inhomogeneously deformed and extremely fractured. Results of TEM examinations indicate that no change in dislocation density was caused by shock loading except in regions containing shock lamellae, where the dislocation density was lowered. The shock-induced defects tend to nucleate on and be controlled by preexisting stress concentrators; shock lamellae, glassy veins, and most curviplanar defects form in tension, presumably during release. An extremely mobile silica fluid is formed and injected into fractures during release, which forcibly removes crystalline fragments from vein walls. It is concluded that shock deformation in quartz is dominated by fracture and melting.

Gratz, Andrew J.↗

Measured and computed performance of a microstrip filter composed of semi-insulating GaAs on a fused quartz substrate

The performance of a microstrip hammerhead filter that has been fabricated on an electrically thin layer of semiinsulating GaAs backed by a fused quartz substrate was measured and compared to results of a three-dimensional finite-difference time-domain (FD-TD) program used to calculate the response of the filter both with and without the GaAs layer. The program, presented by Sheen et al. (1990), discretizes the entire structure and then simulates the propagation of a Gaussian pulse through the filter. The microstrip filter is intended for applications involving ultrathin lifted-off or etched-back GaAs containing both active devices and passive microstrip circuitry backed by a much thicker mechanically rigid low-loss, low-dielectric-constant substrate. The low-pass characteristics of the hammerhead filter with the intermediate GaAs layer are compared with those of the same filter on quartz alone. Both the measured and computed data show a significant shift in cutoff frequency (about 10 percent at the 3 dB points) for a GaAs layer that is 0.007 wavelengths thick at 4 GHz.

Siegel, Peter H.↗

Fragments of quartz monzodiorite and felsite in Apollo 14 soil particles

Samples of 'evolved' lithologies, felsite, quartz monzodiorite (QMD), and whitlockite-rich quartz monzodiorite, were identified compositionally and petrographically among 2-4-mm soil particles from Apollo 14. Fragments of QMD were found to be extremely rare in the Apollo 14 samples. Felsite is similar to previously reported samples. QMD 14161,7069 is similar to 15405 QMD and has ITE concentrations in KREEP-like concentration ratios of about twice the ITE concentrations of average high-K KREEP. QMD cumulate has the highest measured REE concentrations of any lunar sample to date with the exception of individual whitlockite grains. Felsite and whitlockite-rich lithologies appear to be petrogenetically related and have complementary compositions representing separated fractions of the QMD or KREEP-like parental melt. Felsite is a silica-rich fraction of the residual liquid or it is a derivative of the silica-rich fraction. Felsite or lunar granite of this type results from residual liquid separation following crystal-liquid separation of a QMD-like parent melt with concentration ratios of ITEs similar to those of KREEP.

Jolliff, B. L.↗

Influence of the preshock temperature on shock effects in quartz

Shock metamorphic features are the prime indicators for recognizing impact phenomena on Earth and other planetary bodies. Although the pressure dependence of shock features is well known, information about the influence of the preshock temperature is almost lacking. Especially in the case of large-scale impacts like Sudbury, it is expected that deep-seated crustal rocks were subjected to shock at elevated temperatures. Therefore, we continued to perform shock experiments at elevated temperatures on less than 0.5-mm thin disks of single crystal quartz cut parallel to the (1010) face. All recovered quartz samples were investigated by universal stage, spindle stage, and a newly developed density gradient technique. Errors of refractive index and density measurements are +/- 0.0005 and +/- 0.002 g/cu cm respectively. Our investigations indicate that shock metamorphic features are strongly dependent on the preshock temperature. This statement has far-reaching implications with respect to shock wave barometry that is based on data from recovery experiments at room temperature. These datasets might be applicable only to low-temperature target rocks. Moreover, this study demonstrates that shock recovery experiments are definitely required for understanding the complete pressure-temperature regime of shock metamorphism on planetary bodies.

Langenhorst, F.↗

Radiation sensitivity of quartz crystal oscillators experiment for the Long Duration Exposure Facility (LDEF), part 2

The stability of high precision quartz crystal oscillators exposed to the radiation environment of NASA's Long Duration Exposure Facility (LDEF) was studied. Comparisons between pre-flight and post-flight frequency drift rates indicate that oscillators made from swept premium Q quartz exhibited a significantly greater post-flight drift rate than before exposure, but that the effect annealed after five months aging at 75 C (the operating temperature). The result that six years worth of radiation damage annealed out in less than six months suggests that if the oscillators had been powered during the LDEF mission, no net change in drift rate beyond their normal baseline value would have occurred.

Ahearn, J. S.↗

One GHz leaky SAW velocity of metal layers and bilayers evaporated onto fused quartz

An acoustic microscope operating at 1 GHz was used to determine the surface acoustic wave velocities v of thin film metal layers and metal bilayers deposited onto fused quartz. V(0)'s influence was reduced by gating. This produced a calibrated accuracy of 3 percent. A program was constructed from the explicitly solved 6 x 6 theoretical determinant. Single film thicknesses were decided upon by using this theory to produce a v equal to a standard. Since the single film v's were linear with respect to their thickness, half the single film thicknesses were used for the bilayered films. The velocities for these bilayered films agreed with theory. This experimentally confirms the theoretical technique used here to examine bilayered systems, or a prototype composite interphase. No discrepancy was seen for gold films as others have reported. V(z) seemed insensitive to the formation of intermetallics or CuO. Some annealed and unannealed platinum films did not change the v from that of fused quartz. Two platinum films whose v's were in agreement with theory peeled off with the tape test.

Walikainen, Dale↗

Explosive volcanism and associated pressures - Implications for models of endogenically shocked quartz

The nature of explosive volcanic phenomena and associated pressures, both from field and theoretical perspectives, is discussed. An endogenic origin for shocked quartz at the K/T boundary requires impulsive pressures greater than 60 kbars to be generated during explosive volcanism. Explosive volcanic eruptions which are events of sustained decompression may be initiated by impulsive explosions while the magnitudes of the overpressures are small. These maximum overpressures can be controlled mainly by the tensile strength of the rock surrounding the magma chamber-conduit system. Thus maximum overpressures in the volcanic environment are limited to less than 500 bars which are orders of magnitude less than those required for shock quartz (greater than 60 kbars). This observation is found to be consistent with the complete lack of field or petrographic evidence in support of shock metamorphism associated with volcanic eruptions and their products.

De Silva, S. L.↗

Si-29 NMR spectroscopy of naturally-shocked quartz from Meteor Crater, Arizona: Correlation to Kieffer's classification scheme

We have applied solid state Si-29 nuclear magnetic resonance (NMR) spectroscopy to five naturally-shocked Coconino Sandstone samples from Meteor Crater, Arizona, with the goal of examining possible correlations between NMR spectral characteristics and shock level. This work follows our observation of a strong correlation between the width of a Si-29 resonance and peak shock pressure for experimentally shocked quartz powders. The peak width increase is due to the shock-induced formation of amorphous silica, which increases as a function of shock pressure over the range that we studied (7.5 to 22 GPa). The Coconino Sandstone spectra are in excellent agreement with the classification scheme of Kieffer in terms of presence and approximate abundances of quartz, coesite, stishovite, and glass. We also observe a new resonance in two moderately shocked samples that we have tentatively identified with silicon in tetrahedra with one hydroxyl group in a densified form of amorphous silica.

Boslough, M. B.↗

NMR spectroscopy of experimentally shocked single crystal quartz: A reexamination of the NMR shock barometer

Cygan and others report a broadening of the Si-29 nuclear magnetic resonance (NMR) peak for synthetic quartz powders with increasing shock pressure which they propose as a shock wave barometer for natural systems. These results are expanded by studying single crystal quartz shocked to 12 and 33 GPa using the 6.5 m two-stage light-gas gun at Lawrence Livermore National Laboratories. Our NMR results differ substantially from those of Cygan and others and suggest that the proposed shock wave barometer may require refinement. The difference in results between this study and that of Cygan and others is most likely caused by different starting materials (single crystal vs. powder) and different shock loading histories. NMR results from single crystal studies may be more applicable to natural systems.

Fiske, P. S.↗

High-pressure infrared sepctra of alpha-quartz, coesite, stishovite and silica glass

High-pressure infrared absorption spectra of alpha-quatz, coesite, stishovite, and SiO2 glass are consistent with the primary compression mechanism of the initially tetrahedrally bonded phases being the bending of the Si-O-Si angle at pressures less than 10-20 GPa. At higher pressures, up to 40 GPa, we observe a decline in the intensity of the infrared SiO4 asymmetric-stretching vibrations of all three phases, with an increase in the relative amplitude between 700 and 900/cm. This change in intensities is attributed to an increase in the average coordination number of silicon through extreme distortion of tetrahedra. At pressures above approximately 20 GPa, the low-pressure crystalline polymorphs gradually become amorphous, and the infrared spectra provide evidence for an increase in silicon coordination in these high-density amorphous phases. The pressure-amorphized samples prepared from quartz and coesite differ structurally both from each other and from silica glass that has been compressed, and the high pressure spectra indicate that these materials are considerably more disordered than stishovite under comparable pressure conditions. Average mode Grueneisen parameters calculated for quartz, stishovite and fused silica from both infrared and Raman spectra are compatible with the corresponding thermodynamic value of the Grueneisen parameter, however, that of coesite is significantly discrepant.

Williams, Q.↗

Use of the quartz crystal microbalance to determine the monomeric friction coefficient of polyimides

When a thin film of polymer is coated on to a quartz crystal microbalance (QCM), the QCM can be used to detect the rate of increase in weight of the polymer film as the volatile penetrant diffuses into the polymer. From this rate information the diffusion coefficient of the penetrant into the polymer can be computed. Calculations requiring this diffusion coefficient lead to values which approximate the monomeric friction coefficient of the polymer. This project has been concerned with the trial of crystal oscillating circuits suitable for driving polymer coated crystals in an atmosphere of penetrant. For these studies done at room temperature, natural rubber was used as an easily applied polymer that is readily penetrated by toluene vapors, qualities anticipated with polyimides when they are tested at T(g) in the presence of toluene. Three quartz crystal oscillator circuits were tested. The simplest circuit used +/- 5 volt dc and had a transistor to transistor logic (TTL) inverter chip that provides a 180 deg phase shift via a feed back loop. This oscillator circuit was stable but would not drive the crystal when the crystal was coated with polymer and subjected to toluene vapors. Removal of a variable resistor from this circuit increased stability but did not otherwise increase performance. Another driver circuit tested contained a two stage differential input, differential output, wide band video amplifier and also contain a feed back loop. The circuit voltage could not be varied and operated at +/- 5 volts dc; this circuit was also stable but failed to oscillate the polymer coated crystal in an atmosphere saturated with toluene vapors. The third oscillator circuit was of similar construction and relied on the same video amplifier but allowed operation with variable voltage. This circuit would drive the crystal when the crystal was submerged in liquid toluene and when the crystal was coated with polymer and immersed in toluene vapors. The frequency readings obtained when using this oscillating circuit are highly variable. This circuit requires further modification to stabilize frequency readings before its use in studies to determine the diffusion coefficient of penetrant molecules into a polymer film coated on a QCM.

Bechtold, Mary M.↗

Insitu Calibration of Quartz Crystal Microbalances

Computer models that predict the rate at which molecular contamination will deposit on optical surfaces typically use outgassing source terms, measured with quartz crystal microbalances, as a basis for the prediction. The American Society of Testing and Materials, Standard Test Method for Contamination Outgassing Characteristics of Spacecraft Materials (Method E-1559), is probably the best know technique used by the aerospace community to measure the outgassing rates or source terms of materials. A simple method for the insitu calibration of quartz crystal microbalances, based on the heat of enthalphy of Adipic Acid, has been developed and demonstrated by the Marshall Space Flight Center, Environmental Effects Group. The calibration has been demonstrated over a sample temperature range of 25 to 66 degrees Celsius and deposition rates of 7 x 10 (exp -11) grams/cm(sup 2)-s and greater, for several measurement system configurations. This calibration technique is fully compatible with the American Society for Testing and Materials, Method E-1559, as well as other methodology. The calibration requires no modification of outgassing facilities employing an effusion cell and does not degrade the performance or function of typical vacuum systems.

Albyn, Keith↗