Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Protection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Apollo experience report: Thermal protection subsystem

The Apollo command module was the first manned spacecraft to be designed to enter the atmosphere of the earth at lunar-return velocity, and the design of the thermal protection subsystem for the resulting entry environment presented a major technological challenge. Brief descriptions of the Apollo command module thermal design requirements and thermal protection configuration, and some highlights of the ground and flight testing used for design verification of the system are presented. Some of the significant events that occurred and decisions that were made during the program concerning the thermal protection subsystem are discussed.

Pavlosky, J. E.↗

Effects of selected trajectory parameters on weight trends in the shuttle thermal protection system

An empirical heating model, thermal protection system unit weight correlation, and trajectory analysis were used to develop a computation procedure for studying the sensitivity of thermal protection system weights to variations in pertinent trajectory parameters. The analytical techniques used in developing this computer program are described. Application of the analysis to a Space Shuttle Orbiter configuration was performed to demonstrate gross thermal protection system weight trends with selected entry trajectory parameters.

Curry, D. M.↗

The protective effect of a constant magnetic field

The protective effect of a constant magnetic field sharply reduced spontaneous lysis of E. coli cells when subjected to ultraviolet radiation. A protective effect of a CMF was found in a study of tissue cultures of normally growing cells (kidney epithelium) and cancer cells (cells from a cancer of the larynx). The protective effect of a CMF is also seen in a combined exposure of tissue cultures to X-rays and CMF energy (strength of the CMF was 2000 oersteds with a gradient of 500 oersteds/cm). The data obtained are of interest to experimental oncology (development of new methods of treating malignant tumors).

Sosunov, A. V.↗

An effective and practical fire-protection system

A high-performance sandwich-type fire protection system comprising a steel outer sheath and insulation combined in various configurations is described. An inherent advantage of the sheath system over coatings is that it eliminates problems of weatherability, materials strength, adhesion, and chemical attack. An experimental comparison between the protection performance of state-of-the-art coatings and the sheath system is presented, with emphasis on the protection of certain types of steel tanks for fuel storage and transport. Sheath systems are thought to be more expensive than coatings in initial implementation, although they are less expensive per year for sufficiently long applications.

Mansfield, J. A.↗

Leading edge protection for composite blades

A laminated filament composite structure, such as an airfoil for use in an environment in which it is subjected to both foreign object impact and bending is provided with improved leading edge protection. At least one fine wire mesh layer is partially bonded within the composite structure along its neutral bending axis. A portion of the wire mesh layer extends beyond the neutral bending axis and partially around the leading edge where it is bonded to the outer periphery of the primary composite structure. The wire mesh is clad with a metal such as nickel to provide an improved leading edge protective device which is firmly anchored within the composite structure. Also described is a novel method of constructing a composite airfoil so as to further minimize the possibility of losing the leading edge protective device due to delamination caused by impact and bending.

Brantley, J. W.↗

Protection coordination of the Kennedy Space Center electric distribution network

A computer technique is described for visualizing the coordination and protection of any existing system of devices and settings by plotting the tripping characteristics of the involved devices on a common basis. The program determines the optimum settings of a given set of protective devices and configuration in the sense of the best expected coordinated operation of these devices. Subroutines are given for simulating time versus current characteristics of the different relays, circuit breakers, and fuses in the system; coordination index computation; protection checks; plotting; and coordination optimation.

Source record↗

Orbiter Thermal Protection System Development

The development of the Space Shuttle Orbiter Thermal Protection System (TPS) is traced from concept definition, through technical development, to final design and qualification for manned flight. A sufficiently detailed description of the TPS design is presented to support an indepth discussion of the key issues encountered in conceptual design, materials development, and structural integration. Emphasis is placed on the unique combination of requirements which resulted in the use not only of revolutionary design concepts and materials, but also of unique design criteria, newly developed analysis, testing and manufacturing methods, and finally of an unconventional approach to system certification for operational flight. The conclusion is drawn that a significant advance in all areas of thermal protection system development has been achieved which results in a highly efficient, flexible, and cost-effective thermal protection system for the Orbiter of the Space Shuttle System.

Greenshields, D. H.↗

Protection of cooled blades of complex internal structure

The problem of general protection of cooled blades of complex internal structure was solved by a method called SF technique which makes possible the protection of both external and internal surfaces, as well as those of the orifices of cooling air, whatever their diameter. The SF method is most often applied in the case of pack process, at controlled or high activity; it can be of use on previously uncoated parts, but also on pieces already coated by a thermochemical, chemical or PVD method. The respective thickness of external and internal coatings may be precisely predetermined, no parasitic particle being liable to remain inside the parts after application of the protecting treatment. Results obtained to date by application of this method are illustrated by the presentation and examination of a various selection of advanced turbo engines.

Glamiche, P.↗

Multi-cell battery protection system

A multi-cell battery protection system is described wherein each cell has its own individual protective circuit. The protective circuits consist of a solid state comparator unit and a high current switching device such as a relay. The comparator units each continuously monitor the associated cell and when the cell voltage either exceeds a predetermined high level or falls below a predetermined low level, the relay is actuated whereby a bypass circuit is completed across the cell thereby effectively removing the cell from the series of cells.

Thomas, R. D.↗

Space Shuttle Lightning Protection

The technology for lightning protection of even the most advanced spacecraft is available and can be applied through cost-effective hardware designs and design-verification techniques. In this paper, the evolution of the Space Shuttle Lightning Protection Program is discussed, including the general types of protection, testing, and anlayses being performed to assess the lightning-transient-damage susceptibility of solid-state electronics.

Suiter, D. L.↗

Development of a window protection assembly for a shuttle experiment

A window environmental protection assembly developed for the shuttle infrared leeside temperature experiment is described. The assembly consists of a carbon phenolic composite window mount which contains two silicon windows, a fibrous environmental protection plug to protect the windows during launch operations and ascent heating, a release mechanism used to jettison the plug just prior to atmospheric entry, and two pin puller mechanisms which retain the plug. The plug is released from the window mount assemblies using pneumatic pin pullers and separation springs in the release mechanism. The assembly was designed and tested to withstand the severe mechanical and thermal environments which could be experienced at the top of the shuttle orbiter vertical stabilizer during the ascent, on-orbit, and entry periods of the shuttle trajectory.

Bradley, O. H., Jr.↗

Attitude control fault protection - The Voyager experience

The length of the Voyager mission and the communication delay caused by the distances involved made fault protection a necessary part of the Voyager Attitude and Articulation Control Subsystem (AACS) design. An overview of the Voyager attitude control fault protection is given and flight experiences relating to fault protection are provided.

Litty, E. C.↗

Remote sensing of thermal radiation from an aircraft - An analysis and evaluation of crop-freeze protection methods

Thermal images from an aircraft-mounted scanner are used to evaluate the effectiveness of crop-freeze protection devices. Data from flights made while using fuel oil heaters, a wind machine and an undercanopy irrigation system are compared. Results show that the overall protection provided by irrigation (at approximately 2 C) is comparable to the less energy-efficient heater-wind machine combination. Protection provided by the wind machine alone (at approximately 1 C) was found to decrease linearly with distance from the machine by approximately 1 C/100 m. The flights were made over a 1.5 hectare citrus grove at an altitude of 450 m with an 8-14 micron detector. General meteorological conditions during the experiments, conducted during the nighttime, were cold (at approximately -6 C) and calm with clear skies.

Sutherland, R. A.↗

Investigation of Effectiveness of Air-Heating a Hollow Steel Propeller for Protection Against Icing. 2: 50% Impartitioned Blades

The icing protection afforded an internal air-heated propeller blade by radial partitioning at 50-percent chord to confine the heated air to the forward half of the blade was determined in the NACA Cleveland icing research tunnel. A modified production-model hollow steel propeller, was used for the investigation. Temperatures of the blade surfaces for several heating rates were measured under various tunnel Icing' conditions. Photographic observations of ice formations on blade surfaces and blade heat-exchanger effectiveness were obtained. With 50-percent partitioning of the blades, adequate icing protection at 1050 rpm was obtained with a heating rate of 26,000 Btu per hour per blade at the blade shank using an air temperature of 400 F with a flow rate of 280 pounds per hour per blade, which is one-third less heat than was found necessary for similar Ice protection with unpartitioned blades. The chordwise distribution of the applied heat, as determined by surface temperature measurements, was considered unsatisfactory with much of the heat dissipated well back of the leading edge. Heat-exchanger effectiveness of approximately 56 percent also Indicated poor utilization of available heat. This effectiveness was, however, 9 percent greater than that obtained from unpartitioned blades.

Perkins, Porter J.↗

Progress in Protective Coatings for Aircraft Gas Turbines: A Review of NASA Sponsored Research

Problems associated with protective coatings for advanced aircraft gas turbines are reviewed. Metallic coatings for preventing titanium fires in compressors are identified. Coatings for turbine section are also considered, Ductile aluminide coatings for protecting internal turbine-blade cooling passage surface are also identified. Composite modified external overlay MCrAlY coatings deposited by low-pressure plasma spraying are found to be better in surface protection capability than vapor deposited MCrAlY coatings. Thermal barrier coating (TBC), studies are presented. The design of a turbine airfoil is integrated with a TBC, and computer-aided manufacturing technology is applied.

Merutka, J. P.↗

Transient thermal analysis of a titanium multiwall thermal protection system

The application of the SPAR thermal analyzer to the thermal analysis of a thermal protection system concept is discussed. The titanium multiwall thermal protection system concept consists of alternate flat and dimpled sheets which are joined together at the crests of the dimples and formed into 30 cm by 30 cm (12 in. by 12 in.) tiles. The tiles are mechanically attached to the structure. The complex tile geometry complicates thermal analysis. Three modes of heat transfer were considered: conduction through the gas inside the tile, conduction through the metal, and radiation between the various layers. The voids between the dimpled and flat sheets were designed to be small enough so that natural convection is insignificant (e.g., Grashof number 1000). A two step approach was used in the thermal analysis of the multiwall thermal protection system. First, an effective normal (through-the-thickness) thermal conductivity was obtained from a steady state analysis using a detailed SPAR finite element model of a small symmetric section of the multiwall tile. This effective conductivity was then used in simple one dimensional finite element models for preliminary analysis of several transient heat transfer problems.

Blosser, M. L.↗

Lightning protection of wind turbines

Possible damages to wind turbine components due to lightning strikes are discussed and means to prevent the damage are presented. A low resistance path to the ground is noted to be essential for any turbine system, including metal paths on nonmetal blades to conduct the strike. Surge arrestors are necessary to protect against overvoltages both from utility lines in normal operation and against lightning damage to control equipment and contactors in the generator. MOS structures are susceptible to static discharge injury, as are other semiconductor devices, and must be protected by the presence of static protection circuitry. It is recommended that the electronics be analyzed for the circuit transient response to a lightning waveform, to induced and dc current injection, that input/output leads be shielded, everything be grounded, and lightning-resistant components be chosen early in the design phase.

Dodd, C. W.↗