Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A Facile Approach to High Precision Detection of Cell-to-Cell Variation for Li-ion Batteries

Abstract Over the past decade, it has been repeatedly demonstrated that homogeneity in electrochemical performance of lithium-ion cells plays a major role in determining the life and safety of lithium-ion battery modules or packs. Generally, the homogeneity of a battery pack is evaluated by characterizing the cells individually in terms of capacity, mass, impedance. Particularly, high quality electrochemical data heavily relies on the availability of high precision current source to minimize the discrepancy induced by the channel-to-channel variation. Here, a facile and precise measurement method is reported for screening cell-to-cell variations, in which voltage is the only indicator parameter independent of high precision current source. In detail, by connecting the cells in series (CiS), the measurement error of electrochemical data caused by stability and discrepancy of current sources among different charge/discharge equipment can be effectively avoided. The findings of this work showed that the cell-to-cell variations can be simply and sensitively detected with CiS configuration. For example, the relative standard deviation, which is the evaluation criterion of battery homogeneity, was 2.14% based on CiS while it was 0.43% based on individual measurements. The simple and precise CiS measurement is promising for evaluation of cell quality or module integration quality. In addition, this work can also provide a solid foundation for the development of detection algorithms for battery management systems to rapidly monitor battery homogeneity.

25 ENERGY STORAGE↗

Non-linearities in the Lyman-α forest and in its cross-correlation with dark matter halos

Here three-dimensional correlations of the Lyman-α (Lyα) forest and cross correlations between the Lyα forest and quasars have been measured on large scales, allowing a precise measurement of the baryon acoustic oscillation (BAO) feature at redshifts z > 2. These 3D correlations are often modelled using linear perturbation theory, but full-shape analyses to extract cosmological information beyond BAO will require more realistic models capable of describing non-linearities present at smaller scales. We present a measurement of the Lyα forest flux power spectrum from large hydrodynamic simulations — the Sherwood simulations — and compare it to different models describing the small-scale deviations from linear theory. We confirm that the model presented in Arinyo-i-Prats et al. (2015) fits the measured 3D power up to k = 10 h Mpc -1 with an accuracy better than 5%, and show that the same model can also describe the 1D correlations with similar precision. We also present, for the first time, an equivalent study for the cross-power spectrum of halos with the Lyα forest, and we discuss different challenges we face when modelling the cross-power spectrum beyond linear scales. We make all our measured power spectra public in https://github.com/andreufont/sherwoo_p3d. This study is a step towards joint analyses of 1D and 3D flux correlations, and towards using the quasar-Lyα cross-correlation beyond BAO analyses.

79 ASTRONOMY AND ASTROPHYSICS↗

In-Situ Laser Diagnostics to Understand Plasma-Surface Interactions in Titanium Thin Film Deposition

During the current project period the following tasks were completed: (1) We demonstrated the feasibility of a new way of measuring CH3 radicals in a plasma environment using a single, femtosecond (fs) pulsed laser for the first time, in a CH4 + Ar flow. A single fs pulsed Ti:Sa laser was split into two beams and with beam conversion using crystals we generatedtwo beams of 275 nm and 205 nm. The 275 nm was used to predissociate the CH3 radicals to CH2+H, followed by 205 nm Two Photon Laser Induced Fluorescence (TALIF) detection of H atoms, with a 11 ns delay from 275 nm predissociation pulse. (2) We demonstrated preliminary CH3 concentration measurements with spatial (< 100 µm) and time resolution (< 10 ns) by image processing of H and Kr TALIF signal images. (3) The methodology to quantify CH3 concentrations was developed. (4) Preliminary measurements of laser dissociation cross sections for CH4 and CH3 to (CH3+H), and (CH2+H), respectively, were conducted. (5) 275 nm laser dissociation of CH4 is a multiphoton process, and the CH4 dissociation cross section is a more sensitive function of the laser pulse energy than CH4 concentration. In the coming months, we will make more precise measurements of the dissociation cross sections, 𝑘275, 𝐶𝐻4 and 𝑘275, 𝐶𝐻3, by varying the laser energy while keeping the flow composition and conditions constant. This will enable more precise quantification of CH3 radical concentrations. More detailed measurements of CH3 radicals will be conducted in the following months of 2025 (Sept-Dec) in a Titanium Isopropoxide (TIP) + H2 + Ar flow meant for pure phase Ti thin film deposition by Chemical Vapor Deposition (CVD). More precise measurements of 275 nm laser dissociation cross sections for CH4 (to CH3 + H) and CH3 (to CH2 + H) will be conducted in the future. Detailed 275 nm laser predissociation cross sections for CH4 and CH3 dissociation to (CH3+H), and (CH2+H), respectively, as a function of gas heating, plasma power, and laser pulse energy will be evaluated. This will enable quantification of CH3 concentrations in the precursor flow over a substrate with time and spatial resolution. Comparison of the concentrations with 2D numerical simulations can lead to understanding of plasma surface interactions during pure metallic Ti thin film deposition using environmentally safer non-halogen TIP precursor. Flow conditions for pure Ti thin film deposition using non-halogen precursor (TIP) will be identified in the following months.

Uddi, Mruthunjaya [Advanced Cooling Technologies, ↗

Precision of Property Measurements with Reference Molten Salts

Thermochemical and thermophysical properties of reference molten salt systems are being measured to establish the precisions achievable with current state-of-the-art methods including repeatability within a laboratory and reproducibility between laboratories using the same and different methods. Several laboratories across the United States are analyzing salt samples from single source batches of two salts to provide independent measurements of property values and the precisions of different measurement techniques in an interlaboratory study referred to as the Interlaboratory Salt Study (ISS). The compositions of the two salts produced for the study were reported to be eutectic LiF-NaF-KF (46.5-11.5-42 mol %) and NaCl-KCl (50-50 mol %). These salts are referred to herein as ISS FLiNaK and ISS NaCl-KCl. Thermochemical properties being measured at Argonne include thermal transitions and heat capacity by differential scanning calorimetry. Thermophysical properties being measured at Argonne include liquid density and surface tension by using a buoyancy densitometer and thermal diffusivity by using a laser flash analyzer. Thermal conductivity is calculated from measured thermal diffusivity, density and heat capacity values. The results of property measurements made at Argonne using these inter-laboratory salt study salts are presented here.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Prospects of Neutrino Cross Section Measurements Using the NuMI off axis at ICARUS [Poster]

ICARUS, a Liquid Argon Time Projection Chamber, will serve as the Far Detector of the short-baseline neutrino program using the Booster beamline at Fermilab. It is 103 mrad off-axis of the NuMI beamline. Prospects for cross-section measurements and the status of the trigger system using the PMT system to collect electron and muon neutrinos from NuMI will be shown. Accurate neutrino cross-section measurements on argon are required for precise measurements of neutrino oscillation physics such as CP- violation and the ordering of the neutrino masses.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of Rayleigh Scattering in Liquid Argon at Vacuum Ultraviolet Wavelengths

Liquid argon based detectors are limited in scintillation light analysis capabilities due to inconsistent measurements of fundamental constants essential for the reconstruction of scintillation events. This experiment measures the Rayleigh scattering length of vacuum ultraviolet light propagating in liquid argon in support of liquid argon experiments. Preliminary results are presented for the Rayleigh scattering length in a range of vacuum ultraviolet wavelengths. Current data collection and analysis methods in this measurement require further advancements to understand and eliminate anomalous phenomena in the data. Future measurements in this experiment aim to precisely measure the liquid argon ultraviolet light scattering length. Results will contribute to the development of new photon system analysis methods for liquid argon experiments.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Measurement of the Λ hyperon lifetime

A new, more precise measurement of the Λ hyperon lifetime is performed using a large data sample of Pb-Pb collisions at $\sqrt{s_{NN}}$=5.02 TeV with ALICE. The Λ and $\bar{Λ}$ hyperons are reconstructed at midrapidity using their two-body weak decay channel Λ→p+π - and $\bar{Λ}$→$\bar{p}$+π + . The measured value of the Λ lifetime is τ Λ =[261.07±0.37(stat.)±0.72(syst.)] ps. The relative difference between the lifetime of Λ and $\bar{Λ}$, which represents an important test of CPT invariance in the strangeness sector, is also measured. The obtained value (τ Λ -τ $\bar{Λ}$ )/τ Λ =0.0013±0.0028(stat.)±0.0021(syst.) is consistent with zero within the uncertainties. Both measurements of the Λ hyperon lifetime and of the relative difference between τ Λ and τ $\bar{Λ}$ are in agreement with the corresponding world averages of the Particle Data Group and about a factor of three more precise.

43 PARTICLE ACCELERATORS↗

BACCHUS Analysis of Weak Lines in APOGEE Spectra (BAWLAS)

Elements with weak and blended spectral features in stellar spectra are challenging to measure and require specialized analysis methods to precisely measure their chemical abundances. In this work, we have created a catalog of approximately 120,000 giants with high signal-to-noise Apache Point Observatory Galactic Evolution Experiment (APOGEE) Data Release 17 (DR17) spectra, for which we explore weak and blended species to measure Na, P, S, V, Cu, Ce, and Nd abundances and 12 C/ 13 C isotopic ratios. We employ an updated version of the Brussels Automatic Code for Characterizing High-accuracy Spectra (BACCHUS) code to derive these abundances using the stellar parameters measured by APOGEE's DR17 Stellar Parameters and Chemical Abundances Pipeline, quality flagging to identify suspect spectral lines, and a prescription for upper limits. Combined, these allow us to provide our BACCHUS Analysis of Weak Lines in APOGEE Spectra catalog of precise chemical abundances for these weak and blended species, which agrees well with the literature and improves upon APOGEE abundances for these elements, some of which are unable to be measured with APOGEE's current, grid-based approach without computationally expensive expansions. This new catalog can be used alongside APOGEE and provides measurements for many scientific applications ranging from nuclear physics to Galactic chemical evolution and Milky Way population studies. To illustrate this we show some examples of uses for this catalog, such as showing that we observe stars with enhanced s-process abundances or that we can use the 12 C/ 13 C ratios to explore extra mixing along the red giant branch.

79 ASTRONOMY AND ASTROPHYSICS↗

A dark siren measurement of the Hubble constant using gravitational wave events from the first three LIGO/Virgo observing runs and DELVE

The current and next observation seasons will detect hundreds of gravitational waves (GWs) from compact binary systems coalescence at cosmological distances. When combined with independent electromagnetic measurements, the source redshift will be known, and we will be able to obtain precise measurements of the Hubble constant H_0 via the distance–redshift relation. However, most observed mergers are not expected to have electromagnetic counterparts, which prevents a direct redshift measurement. In this scenario, one possibility is to use the dark sirens method that statistically marginalizes over all the potential host galaxies within the GW location volume to provide a probabilistic source redshift. Here we presented H_0 measurements using two new dark sirens compared to previous analyses using DECam data: GW190924|$\_$|021846 and GW200202|$\_$|154313. The photometric redshifts of the possible host galaxies of these two events are acquired from the DECam Local Volume Exploration Survey (DELVE) carried out on the Blanco telescope at Cerro Tololo. The combination of the H_0 posterior from GW190924|$\_$|021846 and GW200202|$\_$|154313 together with the bright siren GW170817 leads to |$H_{0} = 68.84^{+15.51}_{-7.74}\, \rm {km\, s^{-1}\, Mpc^{-1}}$|⁠. Including these two dark sirens improves the 68 per cent confidence interval (CI) by 7 per cent over GW170817 alone. This demonstrates that the addition of well-localized dark sirens in such analysis improves the precision of cosmological measurements. Using a sample containing 10 well-localized dark sirens observed during the third LIGO/Virgo observation run, without the inclusion of GW170817, we determine a measurement of |$H_{0} = 76.00^{+17.64}_{-13.45}\, \rm {km\, s^{-1}\, Mpc^{-1}}$|⁠.

79 ASTRONOMY AND ASTROPHYSICS↗

Luminosity determination using Z boson production at the CMS experiment

The measurement of Z boson production is presented as a method to determine the integrated luminosity of CMS data sets. The analysis uses proton–proton collision data, recorded by the CMS experiment at the CERN LHC in 2017 at a center-of-mass energy of 13 TeV. Events with Z bosons decaying into a pair of muons are selected. The total number of Z bosons produced in a fiducial volume is determined, together with the identification efficiencies and correlations from the same data set, in small intervals of 20 pb –1 of integrated luminosity, thus facilitating the efficiency and rate measurement as a function of time and instantaneous luminosity. Using the ratio of the efficiency-corrected numbers of Z bosons, the precisely measured integrated luminosity of one data set is used to determine the luminosity of another. For the first time, a full quantitative uncertainty analysis of the use of Z bosons for the integrated luminosity measurement is performed. The uncertainty in the extrapolation between two data sets, recorded in 2017 at low and high instantaneous luminosity, is less than 0.5%. We show that the Z boson rate measurement constitutes a precise method, complementary to traditional methods, with the potential to improve the measurement of the integrated luminosity.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Intrinsic energy and time resolution of the Jefferson Lab Hall C Neutral Particle Spectrometer

The Neutral Particle Spectrometer (NPS) is an advanced calorimeter designed to measure neutral electro- magnetic particles with high precision in energy, time, and position, under conditions of high luminosity and significant background. Integrated into the experimental setup of Hall C at Thomas Jefferson National Accelerator Facility, the NPS plays a critical role in studies of nucleon structure through exclusive and semi- inclusive reaction channels. Here, this paper presents an assessment of the detector’s performance characteristics, specifically its energy and timing resolution, derived from elastic electron–proton scattering data. We report an energy resolution between 1.2% and 1.3% in the 4.5–7.3 GeV range, and an intrinsic timing resolution better than 200 ps for energies above 500 MeV. These results serve as a reference for current and future precision measurements in hadronic physics.

Detector performance↗

A method to determine the electric field of liquid argon time projection chambers using a UV laser system and its application in MicroBooNE

Liquid argon time projection chambers (LArTPCs) are now a standard detector technology for making accelerator neutrino measurements, due to their high material density, precise tracking, and calorimetric capabilities. An electric field (E-field) is required in such detectors to 2020 JINST 15 P07010 drift ionization electrons to the anode where they are collected. The E-field of a TPC is often approximated to be uniform between the anode and the cathode planes. However, significant distortions can appear from effects such as mechanical deformations, electrode failures, or the accumulation of space charge generated by cosmic rays. The latter effect is particularly relevant for detectors placed near the Earth’s surface and with large drift distances and long drift time. To determine the E-field in situ, an ultraviolet (UV) laser system is installed in the MicroBooNE experiment at Fermi National Accelerator Laboratory. The purpose of this system is to provide precise measurements of the E-field, and to make it possible to correct for 3D spatial distortions due to E-field non-uniformities. Here we describe the methodology developed for deriving spatial distortions, the drift velocity and the E-field from UV-laser measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Examination of Legacy Metallic Fuel Pins (U-10Zr) Tested in FFTF

The MFF series of metallic fuel (U-10wt%Zr) tests performed in the Fast Fuel Test Facility (FFTF) were the beginning tests to qualify the fuel as a driver fuel for FFTF. They all performed very well, to relatively high burnup and with no pin breaches. Tests MFF-3 and MFF-5 were chosen to be destructively examined because they were run at high peak cladding temperatures, 643 and 649°C respectively, and to modest to high burnup (138 and 101 MWd/kgM respectively). They were the only sodium fast reactor (SFR) metallic tests, with long (91.4 cm) fuel columns and clad in HT9, to be operated at these high temperatures. Extensive operating condition reconstruction was performed to accompany the examination, providing detailed operating conditions axially along the pins. In addition, detailed ORIGEN calculations provided fuel burnup along the pin length. These calculations and detailed cross-section metallography allowed a PhD dissertation to be performed where the fuel/cladding chemical interaction (FCCI) was modeled using Fickian and Soret Effect driven diffusion of rare earth fission products to the cladding surface and interact with the cladding. The examination of the MFF-3 and MFF-5 pins included neutron radiography, axial profilometry including pin bow and length measurements, precision gamma scanning, plenum gas puncturing to measure fission gas release, detailed chemical/isotopic analyses of fuel samples to confirm burnup calculations, and metallography of pin cross-sections, including micro-hardness measurements of fuel and cladding.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

A Gaseous Argon-Based Near Detector to Enhance the Physics Capabilities of DUNE

This document presents the concept and physics case for a magnetized gaseous argon-based detector system (ND-GAr) for the Deep Underground Neutrino Experiment (DUNE) Near Detector. This detector system is required in order for DUNE to reach its full physics potential in the measurement of CP violation and in delivering precision measurements of oscillation parameters. In addition to its critical role in the long-baseline oscillation program, ND-GAr will extend the overall physics program of DUNE. The LBNF high-intensity proton beam will provide a large flux of neutrinos that is sampled by ND-GAr, enabling DUNE to discover new particles and search for new interactions and symmetries beyond those predicted in the Standard Model.

47 OTHER INSTRUMENTATION↗

Lepton-Nucleus Scattering Measurements for Neutrino Interactions and Oscillations

Currently running and forthcoming precision neutrino oscillation experiments aim to unambiguously determine the neutrino mass ordering, the charge-parity violating phase in the lepton sector and the possible existence of physics Beyond the Standard Model. To have an understanding of all the effects necessary for the success of these experiments, lepton-nucleus interactions must be modeled in unprecedented detail. With this thesis, expertise in both neutrino and electron cross-section modeling and analysis was leveraged in order to make fundamental and critical improvements to our understanding of these interactions. The outlined work takes a significant step towards this high-precision measurement era with three complementary approaches. Cross sections are reported using neutrino data sets from the MicroBooNE liquid argon time projection chamber detector at Fermi National Laboratory, as well as electron scattering data from the CLAS detector at Thomas Jefferson National Laboratory. Furthermore, the modeling development of the commonly used GENIE event generator is presented.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Lepton-Nucleus Scattering Measurements for Neutrino Interactions and Oscillations

Currently running and forthcoming precision neutrino oscillation experiments aim to unambiguously determine the neutrino mass ordering, the charge-parity violating phase in the lepton sector and the possible existence of physics Beyond the Standard Model. To have an understanding of all the effects necessary for the success of these experiments, lepton-nucleus interactions must be modeled in unprecedented detail. With this thesis, expertise in both neutrino and electron cross-section modeling and analysis was leveraged in order to make fundamental and critical improvements to our understanding of these interactions. The outlined work takes a significant step towards this high-precision measurement era with three complementary approaches. Cross sections are reported using neutrino data sets from the MicroBooNE liquid argon time projection chamber detector at Fermi National Laboratory, as well as electron scattering data from the CLAS detector at Thomas Jefferson National Laboratory. Furthermore, the modeling development of the commonly used GENIE event generator is presented.

Papadopoulou, Afroditi↗

Dark Energy Survey Year 3 results: Cosmology from cosmic shear and robustness to data calibration

This work, together with its companion paper, Secco, Samuroff et al., presents the Dark Energy Survey Year 3 cosmic shear measurements and cosmological constraints based on an analysis of over 100 million source galaxies. With the data spanning 4143 deg 2 on the sky, divided into four redshift bins, we produce the highest significance measurement of cosmic shear to date, with a signal-to-noise of 40. We conduct a blind analysis in the context of the ΛCDM model and find a 3% constraint of the clustering amplitude, S 8 ≡ σ 8 (Ω m /0.3) 0.5 = 0.759$^{+0.025}_{-0.023}$. A ΛCDM-Optimized analysis, which safely includes smaller scale information, yields a 2% precision measurement of S 8 = 0.772$^{+0.018}_{-0.017}$ that is consistent with the fiducial case. The two low-redshift measurements are statistically consistent with the Planck Cosmic Microwave Background result, however, both recovered S 8 values are lower than the high-redshift prediction by 2.3σ and 2.1σ (ρ-values of 0.02 and 0.05), respectively. The measurements are shown to be internally consistent across redshift bins, angular scales and correlation functions. The analysis is demonstrated to be robust to calibration systematics, with the S 8 posterior consistent when varying the choice of redshift calibration sample, the modeling of redshift uncertainty and methodology. Similarly, we find that the corrections included to account for the blending of galaxies shifts our best-fit S 8 by 0.5σ without incurring a substantial increase in uncertainty. We examine the limiting factors for the precision of the cosmological constraints and find observational systematics to be subdominant to the modeling of astrophysics. Specifically, we identify the uncertainties in modeling baryonic effects and intrinsic alignments as the limiting systematics.

79 ASTRONOMY AND ASTROPHYSICS↗

DUNE-PRISM – A New Method to Measure Neutrino Oscillations

The Deep Underground Neutrino Experiment (DUNE) is a next-generation long baseline neutrino oscillation experiment designed to make precision measurements in a 1.2 2.4 MW neutrino beam, which is directed 1285 km from the Fermi National Accelerator Laboratory (Fermilab) to the Sandford Underground Research Facility (SURF) in South Dakota. Neutrinos are measured at two detector facilities: a near detector located at Fermilab close where the beam is produced and a far detector at SURF. The neutrino beam can be configured to be composed primarily of either muon or anti-muon neutrinos. DUNE measures the disappearance of muon and anti-muon neutrinos and appearance electron and anti-electron neutrinos in the neutrino beam. Measuring these neutrino flavour transitions provides DUNE with sensitivity to the neutrino mass ordering, $\delta_{CP}$, $\theta_{13}$, $\theta_{23}$ and the magnitude of $\Delta m^2_{23}$. The DUNE Precision Reaction Independent Spectrum Measurement (DUNE-PRISM) concept presents a novel way to perform a neutrino oscillation analysis, which has the potential to significantly reduce the impact of large systematic uncertainties in the neutrino interaction model. The PRISM method linearly combines measurements of off-axis neutrino interactions at the DUNE near detector to produce data-driven predictions of the oscillated neutrino event rate spectrum at the far detector. By building an oscillated far detector prediction directly from data, any unknown or poorly modelled neutrino interaction effects will be naturally incorporated into the measurement of the parameters of the neutrino oscillation model. This thesis presents the first complete neutrino oscillation analysis for DUNE using the PRISM method. Details of the methodology are fully explained and the prospects for further improvements to the techniques described are highlighted. The expected impact and relative importance of the neutrino flux, cross section and detector systematic uncertainties are described in detail. Finally, this thesis demonstrates that the PRISM method is capable of performing a measurement of the oscillation parameters that is robust against neutrino interaction modelling errors.

Hasnip, Ciaran↗