Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Precision measurements”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

High-precision mass measurement of Si 24 and a refined determination of the r p process at the A = 22 waiting point

We report a high-precision mass measurement of 24 Si, performed with the Low Energy Beam and Ion Trap (LEBIT) facility at the National Superconducting Cyclotron Laboratory. The atomic mass excess, 10 753.8 (37) keV, is a factor of 5 more precise than previous results. This substantially reduces the uncertainty of the 23 Al(p ,γ) 24 Si reaction rate, which is a key part of the rapid proton capture (rp) process powering type I x-ray bursts. Furthermore, the updated rate constrains the onset temperature of the (α,p) process at the 22 Mg waiting point to a precision of 9%.

20 ≤ A ≤ 38↗

Precision Mass Measurements of Neutron-Rich Scandium Isotopes Refine the Evolution of N = 32 and N = 34 Shell Closures

In this work, we report high-precision mass measurements of 50–55 Sc isotopes performed at the LEBIT facility at NSCL and at the TITAN facility at TRIUMF. Our results provide a substantial reduction of their uncertainties and indicate significant deviations, up to 0.7 MeV, from the previously recommended mass values for 53–55 Sc. The results of this work provide an important update to the description of emerging closed-shell phenomena at neutron numbers N = 32 and N = 34 above proton-magic Z = 20. In particular, they finally enable a complete and precise characterization of the trends in ground state binding energies along the N = 32 isotone, confirming that the empirical neutron shell gap energies peak at the doubly magic 52 Ca. Moreover, our data, combined with other recent measurements, do not support the existence of a closed neutron shell in 55 Sc at N = 34. The results were compared to predictions from both ab initio and phenomenological nuclear theories, which all had success describing N = 32 neutron shell gap energies but were highly disparate in the description of the N = 34 isotone.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision insolation measurement under field conditions

The paper describes a precision insolation instrument - the Mark 3 Kendall Radiometer - developed for field survey work and for use as a calibration transfer standard. The instrument, which can be used to make accurate measurements of solar irradiance, has a windowless black cavity receptor mounted in a massive heat sink and has equal sensitivity to ultraviolet, infrared, and visible radiation. Attention is given to a calibration stability analysis over two years of operation.

Reid, M. S.↗

Value of Sample Return and High Precision Analyses: Need for A Resource of Compelling Stories, Metaphors and Examples for Public Speakers

There is widespread agreement among planetary scientists that much of what we know about the workings of the solar system comes from accurate, high precision measurements on returned samples. Precision is a function of the number of atoms the instrumentation is able to count. Accuracy depends on the calibration or standardization technique. For Genesis, the solar wind sample return mission, acquiring enough atoms to ensure precise SW measurements and then accurately quantifying those measurements were steps known to be non‐trivial pre‐flight. The difficulty of precise and accurate measurements on returned samples, and why they cannot be made remotely, is not communicated well to the public. In part, this is be-cause "high precision" is abstract and error bars are not very exciting topics. This paper explores ideas for collecting and compiling compelling metaphors and colorful examples as a resource for planetary science public speakers.

Allton, J. H.↗

Thermal-Expansion Measurement

Precise stable laser system determines coefficients of thermal expansion. Dual-beam interferometer arrangement monitors changes in sample length as function of temperature by following changes inoptical path lengths.

Davis, J. H.↗

Improved rocket ozonesonde (ROCOZ-A). I - Demonstration of precision

Measurements of the daytime ozone distribution in the stratosphere have been made with an improved rocket ozonesonde (ROCOZ-A). Vertical cumulative ozone as a function of geometric altitude is the basic information content of these measurements. The instrument-to-instrument repeatability of the ozonesonde was determined by two series of four soundings each. At one standard deviation the instrument repeatability averages from 2.0 to 2.5 percent over the entire altitude range of the instrument. The worst measured repeatability is 3.7 percent at 55 km for one of the flight series.

Holland, A. C.↗

An evaluation of water vapor radiometer data for calibration of the wet path delay in very long baseline interferometry experiments

The internal consistency of the baseline-length measurements derived from analysis of several independent VLBI experiments is an estimate of the measurement precision. The paper investigates whether the inclusion of water vapor radiometer (WVR) data as an absolute calibration of the propagation delay due to water vapor improves the precision of VLBI baseline-length measurements. The paper analyzes 28 International Radio Interferometric Surveying runs between June 1988 and January 1989; WVR measurements were made during each session. The addition of WVR data decreased the scatter of the length measurements of the baselines by 5-10 percent. The observed reduction in the scatter of the baseline lengths is less than what is expected from the behavior of the formal errors, which suggest that the baseline-length measurement precision should improve 10-20 percent if WVR data are included in the analysis. The discrepancy between the formal errors and the baseline-length results can be explained as the consequence of systematic errors in the dry-mapping function parameters, instrumental biases in the WVR and the barometer, or both.

Kuehn, C. E.↗

Precision Mass Measurements Reveal Low Neutron Pairing in Tin beyond 𝑁=82 and Its Impact on Stellar Nucleosynthesis

We present a study on neutron-rich tin (𝑍 =50) isotopes beyond the doubly closed shell of 𝑁 = 82 through high-precision mass measurements, including the first-ever measurements of the masses of 136 Sn, 137 Sn, and 138 Sn isotopes. These measurements enhance our understanding of the nuclear structure and astrophysical nucleosynthesis in this previously unexplored region. The new mass data are used for evaluation of the final abundances of mass numbers 𝐴 =135 and 137 in 𝑟-process network calculations. Our findings reveal a notable change in the empirical pairing gap for tin isotopes beyond the 𝑁 = 82 closed shell and a shift in the two-neutron-separation energy slope compared to heavier elements above the shell closure. A new set of ab initio calculations effectively describes these observed trends.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Assessment of GOES-16/ABI middle wave infrared band using references of Himawari-8/AHI and Aqua/MODIS

GOES-16 is the first of the GOES-R series of Geostationary Operational Environmental Satellites (GOES) and was launched on November 19, 2016. The spacecraft was initially in a test position of 89.5° West and reached its operational position (75.2° West) on December 11, 2017. The Himawari-8 spacecraft was launched on October 7, 2014 and is located at 140.7º East. The similar design and similar calibration algorithm between the Advanced Baseline Imager (ABI) on-board GOES-16 and the Advanced Himawari Imager (AHI) on board Himawari-8 makes the importance of inter-comparison. Due to their locations, double difference is an appropriate method for their comparison and Aqua MODIS is one of good references. However, ABI (AHI) midwave-infrared (MWIR) band 7 does not have good matching with Aqua MODIS. In this work, the ABI-AHI comparison and ABI assessment for MWIR band 7 is performed using Aqua bands 20, 22, and 23. The ocean sites under ABI (AHI) at nadir are used for inter-comparison with Aqua MODIS. To enhance the comparison accuracy, a few procedures and corrections have been applied. For MWIR band 7, the ABI-AHI difference is about -0.39K over ocean scene, with the ABI measurement precision being slightly better than that of AHI. This double difference method is also being used for the assessment of ABI consistency before and after re-location on November 30, 2017. Two ocean scenes are selected for the ABI re-location assessments, with measurement precision at nadir providing better measurements than non-zero view angles. The ABI MWIR measurement over the ocean scene at the same view angle before and after re-location shows that the precisions are comparable. The MWIR band brightness temperature (BT) measurement over ocean scene shows a 0.04K difference, while the measurement precision before and after re-location is consistent.

Inter-comparison↗

High-precision mass measurements of the isomeric and ground states of 44 V: Improving constraints on the isobaric multiplet mass equation parameters of the A=44, 0 + quintet

Background: The quadratic isobaric multiplet mass equation (IMME) has been very successful at predicting the masses of isobaric analog states in the same multiplet, while its coefficients are known to follow specific trends as functions of mass number. The Atomic Mass Evaluation 2016 [Chin. Phys. C 41, 030003 (2017)] 44 V mass value results in an anomalous negative c coefficient for the IMME quadratic term; a consequence of large uncertainty and an unresolved isomeric state. The b and c coefficients can provide useful constraints for construction of the isospin-nonconserving Hamiltonians for the pf shell. In addition, the excitation energy of the 0 + , T = 2 level in 44 V is currently unknown. This state can be used to constrain the mass of the more exotic 44 Cr. Purpose: The aim of the experimental campaign was to perform high-precision mass measurements to resolve the difference between 44 V isomeric and ground states, to test the IMME using the new ground state mass value and to provide necessary ingredients for the future identification of the 0 + , T = 2 state in 44 V. Method: High-precision Penning trap mass spectrometry was performed at LEBIT, located at the National Superconducting Cyclotron Laboratory, to measure the cyclotron frequency ratios of [ 44g,m VO] + versus [ 32 SCO] + , a well-known reference mass, to extract both the isomeric and ground state masses of 44 V. Results: The mass excess of the ground and isomeric states in 44 V were measured to be -23 804.9(80) keV/c 2 and -23 537.0(55) keV/c 2 , respectively. This yielded a new proton separation energy of S p = 1 773(10) keV. Conclusion: The new values of the ground state and isomeric state masses of 44 V have been used to deduce the IMME b and c coefficients of the lowest 2 + and 6 + triplets in A = 44. The 2 + c coefficient is now verified with the IMME trend for lowest multiplets and is in good agreement with the shell-model predictions using charge-dependent Hamiltonians. The mirror energy differences were determined between 44 V and 44 Sc, in line with isospin-symmetry for this multiplet. Finally, the new value of the proton separation energy determined, to an uncertainty of 10 keV, will be important for the determination of the 0 + , T = 2 state in 44 V and, consequently, for prediction of the mass excess of 44 Cr.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Modeling of Impact Ionization and Charge Trapping in SuperCDMS HVeV Detectors

A model for charge trapping and impact ionization, and an experiment to measure these parameters is presented for the SuperCDMS HVeV detector. A procedure to isolate and quantify the main sources of noise (bulk and surface charge leakage) in the measurements is also describe. This sets the stage to precisely measure the charge trapping and impact ionization probabilities in order to incorporate this model into future dark matter searches.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Molecular and Higher Precision Isotopic Measurements of the Mars Atmosphere and Subsurface Volatiles

In response to the question 'what to do next' at Mars we explore the value of a high precision in situ measurement of isotopic and trace gas constituents in the atmosphere combined with a similar analysis of gas extracted from near surface rocks and soils. The scientific goals are to advance our understanding of the evolution of the Martian atmosphere and to search for fossils of past geochemical conditions. One element of this program that ties directly to the goals of the Astrobiology Program will be a sensitive search for simple or complex organic molecules contained in the atmosphere and in the solid phase. The broad chemical and isotopic analysis planned insures that a highly successful program will be carried out even if no organics are detected. We will demonstrate that the technology to carry out this Program is presently in hand.

Mahaffy, P. R.↗

Measurements and computational analysis of the natural decay of 176 Lu

Background: Mainly because of its long half-life and despite its scientific relevance, spectroscopic measurements of 176 Lu forbidden β decays are very limited and lack formulation of shape factors. A direct precise measurement of its Q value is also presently unreported. In addition, the description of forbidden decays provides interesting challenges for nuclear theory. The comparison of precise experimental results with theoretical calculations for these decays can help to test underlying models and can aid the interpretation of data from other experiments. Purpose: Perform the first precision measurements of 176 Lu β-decay spectra and attempt the observation of its electron capture decays, as well as perform the first precision direct measurement of the 176 Lu β-decay Q value. Compare the shape of the precisely determined experimental β spectra to theoretical calculations, and compare the end point energy to that obtained from an independent Q value measurement. Method: Here, the 176 Lu β-decay spectra measurements and the search for electron capture decays were performed with an experimental setup that employed lutetium-containing scintillator crystals and a NaI(Tl) spectrometer for coincidence counting. The β decay Q value was determined via high-precision Penning trap mass spectrometry (PTMS) with the LEBIT facility at the National Superconducting Cyclotron Laboratory. The β-spectrum calculations were performed within the Fermi theory formalism with nuclear structure effects calculated using a shell model approach. Results: Both β transitions of 176 Lu were experimentally observed and corresponding shape factors formulated in their entire energy ranges. The search for electron capture decay branches led to an experimental upper limit of 6.3×10 –6 relative to its β decays. The 176 Lu β-decay and electron capture Q values were measured using PTMS to be 1193.0(6) and 108.9(8) keV, respectively. This enabled precise β end point energies of 596.2(6) and 195.3(6) keV to be determined for the primary and secondary β decays, respectively. The conserved vector current hypothesis was applied to calculate the relativistic vector matrix elements. The β-spectrum shape was shown to significantly depend on the Coulomb displacement energy and on the value of the axial vector coupling constant gA, which was extracted according to different assumptions. Conclusion: The implemented self-scintillation method has provided unmatched observations of 176 Lu, independently validated by the first direct measurements of its β-decay Q value by Penning trap mass spectrometry. Theoretical study of the main β transition led to the extraction of very different effective gA and log10f values, showing that a high-precision description of this transition would require a realistic nuclear structure with nucleus deformation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Precision Mass Measurement of the Proton Dripline Halo Candidate 22 Al

Here, we report the first mass measurement of the proton-halo candidate 22 Al performed with the low energy beam ion trap facility’s 9.4 T Penning trap mass spectrometer at facility for rare isotope beams. This measurement completes the mass information for the lightest remaining proton-dripline nucleus achievable with Penning traps. 22 Al has been the subject of recent interest regarding a possible halo structure from the observation of an exceptionally large isospin asymmetry [J. Lee et al ., Large isospin asymmetry in Si22/O22 Mirror Gamow-Teller transitions reveals the halo structure of 22 Al , Phys. Rev. Lett. 125, 192503 (2020).]. The measured mass excess value of ME=18 092.5⁢(3) keV, corresponding to an exceptionally small proton separation energy of 𝑆𝑝=100.4⁢(8) keV, is compatible with the suggested halo structure. Our result agrees well with predictions from 𝑠⁢𝑑-shell USD Hamiltonians. While USD Hamiltonians predict deformation in the 22 Al ground state with minimal 1⁢𝑠 1/2 occupation in the proton shell, a particle-plus-rotor model in the continuum suggests that a proton halo could form at large quadrupole deformation. These results emphasize the need for a charge radius measurement to conclusively determine the halo nature.

binding energy↗

Precision luminosity measurement in proton–proton collisions at $\sqrt{s}$ = 13 TeV in 2015 and 2016 at CMS

The measurement of the luminosity recorded by the CMS detector installed at LHC interaction point 5, using proton–proton collisions at √s = 13 TeV in 2015 and 2016, is reported. The absolute luminosity scale is measured for individual bunch crossings using beam-separation scans (the van der Meer method), with a relative precision of 1.3 and 1.0% in 2015 and 2016, respectively. The dominant sources of uncertainty are related to residual differences between the measured beam positions and the ones provided by the operational settings of the LHC magnets, the factorizability of the proton bunch spatial density functions in the coordinates transverse to the beam direction, and the modeling of the effect of electromagnetic interactions among protons in the colliding bunches. When applying the van der Meer calibration to the entire run periods, the integrated luminosities when CMS was fully operational are 2.27 and 36.3 fb -1 in 2015 and 2016, with a relative precision of 1.6 and 1.2%, respectively. These are among the most precise luminosity measurements at bunched-beam hadron colliders.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Automatic Telescope Search for Extrasolar Planets

We are using automatic photoelectric telescopes at the Tennessee State University Center for Automated Space Science to search for planets around nearby stars in our galaxy. Over the past several years, wc have developed the capability to make extremely precise measurements of brightness changes in Sun-like stars with automatic telescopes. Extensive quality control and calibration measurements result in a precision of 0.l% for a single nightly observation and 0.0270 for yearly means, far better than previously thought possible with ground-based observations. We are able, for the first time, to trace brightness changes in Sun-like stars that are of similar amplitude to brightness changes in the Sun, whose changes can be observed only with space-based radiometers. Recently exciting discoveries of the first extrasolar planets have been announced, based on the detection of very small radial-velocity variations that imply the existence of planets in orbit around several Sun-like stars. Our precise brightness measurements have been crucial for the confirmation of these discoveries by helping to eliminate alternative explanations for the radial-velocity variations. With our automatic telescopes, we are also searching for transits of these planets across the disks of their stars in order to conclusively verify their existence. The detection of transits would provide the first direct measurements of the sizes, masses, and densities of these planets and, hence, information on their compositions and origins.

Henry, Gregory W.↗

Precise laboratory measurements of methanol rotational transition frequencies in the 5 to 13 GHz region

Rotational transitions for CH3OH were measured in the 5-13 GHz range with a precision and accuracy of a few kilohertz or less using a Flygare-Balle type pulsed-beam Fourier transform microwave spectrometer. The accurate center frequencies measured should be useful in determining accurate Doppler shifts and making positive molecule identification in radio astronomy.

Breckenridge, S. M.↗