Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Positioning System”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Multipurpose epithermal neutron beam on new research station at MARIA research reactor in Swierk-Poland

MARIA reactor is an open-pool research reactor what gives the chance to install uranium fission converter on the periphery of the core. It could be installed far enough not to induce reactivity of the core but close enough to produce high flux of fast neutrons. Special design of the converter is now under construction. It is planned to set the research stand based on such uranium converter in the near future: in 2015 MARIA reactor infrastructure should be ready (preparation started in 2013), in 2016 the neutron beam starts and in 2017 opening the stand for material and biological research or for medical training concerning BNCT. Unused for many years, horizontal channel number H2 at MARIA research rector in Poland, is going to be prepared as a part of unique stand. The characteristics of the neutron beam will be significant advantage of the facility. High flux of neutrons at the level of 2x10{sup 9} cm{sup -2}s{sup -1} will be obtainable by uranium neutron converter located 90 cm far from the reactor core fuel elements (still inside reactor core basket between so called core reflectors). Due to reaction of core neutrons with converter U{sub 3}Si{sub 2} material it will produce high flux of fast neutrons. After conversion neutrons will be collimated and moderated in the channel by special set of filters and moderators. At the end of H2 channel i.e. at the entrance to the research room neutron energy will be in the epithermal energy range with neutron intensity at least at the level required for BNCT (2x10{sup 9} cm{sup -2}s{sup -1}). For other purposes density of the neutron flux could be smaller. The possibility to change type and amount of installed filters/moderators which enables getting different properties of the beam (neutron energy spectrum, neutron-gamma ratio and beam profile and shape) is taken into account. H2 channel is located in separate room which is adjacent to two other empty rooms under the preparation for research laboratories (200 m2). It is planned to create fully equipped complex facility possible to perform various experiments on the intensive neutron beam. Epithermal neutron beam enables development across the full spectrum of materials research for example shielding concrete tests or electronic devices construction improvement. Due to recent reports on the construction of the accelerator for the Boron Neutron Capture Therapy (BNCT) it has the opportunity to become useful and successful method in the fight against brain and other types of cancers not treated with well known medical methods. In Europe there is no such epithermal neutron source which could be used throughout the year for training and research for scientist working on BNCT what makes the stand unique in Europe. Also our research group which specializes in mixed radiation dosimetry around nuclear and medical facilities would be able to carry out research on new detectors and methods of measurements for radiological protection and in-beam (therapeutic) dosimetry. Another group of scientists from National Centre for Nuclear Research, where MARIA research reactor is located, is involved in research of gamma detector systems. There is an idea to develop Prompt-gamma Single Photon Emission Computed Tomography (Pg- SPECT). This method could be used as imaging system for compounds emitting gamma rays after nuclear reaction with thermal neutrons e.g. for boron concentration in BNCT. Inside the room, where H2 channel is located, there is another horizontal channel - H1 which is also unused. Simultaneously with the construction of the H2 stand it will be possible to create special pneumatic horizontal mail inside the H1 channel for irradiation material samples in the vicinity of the core i.e. in the distal part of the H1 channel. It might expand the scope of research at the planned neutron station. Secondly it is planned to equip both stands with moveable positioning system, video system and facilities to perform animal experiments (anaesthesia, vital signs control, imaging devices, positioning). These all above make constructed station unique in the world (uranium fission converter-based beam) and the only one of such intense neutron beam in the Europe. Moreover implementation of the station would allow the development of research on a number of issues for researchers from all over the Europe. One of very important advantages of the station is undisturbed exploitation of the reactor and other vertical and horizontal channels. MARIA reactor operates 6000 hours per year and that amount of time will be achievable for research on the neutron station. It have to be underlined that new neutron station will work parallel to all another ventures. (authors)

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Toward Rapid Unattended X-ray Tomography of Large Planar Samples at 50-nm Resolution

X-ray tomography at sub-50 nm resolution of small areas ({approx}15 {mu}mx15 {mu}m) are routinely performed with both laboratory and synchrotron sources. Optics and detectors for laboratory systems have been optimized to approach the theoretical efficiency limit. Limited by the availability of relatively low-brightness laboratory X-ray sources, exposure times for 3-D data sets at 50 nm resolution are still many hours up to a full day. However, for bright synchrotron sources, the use of these optimized imaging systems results in extremely short exposure times, approaching live-camera speeds at the Advanced Photon Source at Argonne National Laboratory near Chicago in the US These speeds make it possible to acquire a full tomographic dataset at 50 nm resolution in less than a minute of true X-ray exposure time. However, limits in the control and positioning system lead to large overhead that results in typical exposure times of {approx}15 min currently.We present our work on the reduction and elimination of system overhead and toward complete automation of the data acquisition process. The enhancements underway are primarily to boost the scanning rate, sample positioning speed, and illumination homogeneity to performance levels necessary for unattended tomography of large areas (many mm{sup 2} in size). We present first results on this ongoing project.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A review of the remote sensing of lower tropospheric thermodynamic profiles and its indispensable role for the understanding and the simulation of water and energy cycles: REMOTE SENSING OF THERMODYNAMIC PROFILES

A review of remote sensing technology for lower tropospheric thermodynamic (TD) profiling is presented with focus on high accuracy and high temporal-vertical resolution. The contributions of these instruments to the understanding of the Earth system are assessed with respect to radiative transfer, land surface-atmosphere feedback, convection initiation, and data assimilation. We demonstrate that for progress in weather and climate research, TD profilers are essential. These observational systems must resolve gradients of humidity and temperature in the stable or unstable atmospheric surface layer close to the ground, in the mixed layer, in the interfacial layer—usually characterized by an inversion—and the lower troposphere. A thorough analysis of the current observing systems is performed revealing significant gaps that must be addressed to fulfill existing needs. We analyze whether current and future passive and active remote sensing systems can close these gaps. A methodological analysis and demonstration of measurement capabilities with respect to bias and precision is executed both for passive and active remote sensing including passive infrared and microwave spectroscopy, the global navigation satellite system, as well as water vapor and temperature Raman lidar and water vapor differential absorption lidar. Whereas passive remote sensing systems are already mature with respect to operational applications, active remote sensing systems require further engineering to become operational in networks. However, active remote sensing systems provide a smaller bias as well as higher temporal and vertical resolutions. For a suitable mesoscale network design, TD profiler system developments should be intensified and dedicated observing system simulation experiments should be performed.

58 GEOSCIENCES↗

A large dataset of detection and submeter-accurate 3-D trajectories of juvenile Chinook salmon

Abstract Acoustic telemetry has been used extensively to study the behavior of aquatic animals. The Juvenile Salmon Acoustic Telemetry System (JSATS) is one such system; it was developed for studying juvenile salmonids but has been used to study numerous species. A recent innovation of the JSATS system is an acoustic transmitter that is small enough to be implanted through injection or small incision that doesn’t require sutures. Use of the JSATS system involves deploying cabled acoustic receivers at hydroelectric dams, or other structures, and autonomous acoustic receivers in free-flowing sections of a river. The raw detections from acoustic-tagged fish are processed to remove potential false positives. The clean detections (5,147,996 total) are used to generate detection events and to compute 3-D trajectories (403,900 total), which are used to assign fish to a passage route through a dam. Controlled field testing involving a high-accuracy Global Positioning System receiver is done to validate the submeter accuracy of the trajectories. The JSATS dataset could be reused for expanding the understanding of near-dam fish behavior.

59 BASIC BIOLOGICAL SCIENCES↗

Phased plan for the implementation of the time-resolving magnetic recoil spectrometer on the National Ignition Facility (NIF)

The time-resolving magnetic recoil spectrometer (MRSt) is a transformative diagnostic that will be used to measure the time-resolved neutron spectrum from an inertial confinement fusion implosion at the National Ignition Facility (NIF). It uses a CD foil on the outside of the hohlraum to convert fusion neutrons to recoil deuterons. An ion-optical system positioned outside the NIF target chamber energy-disperses and focuses forward-scattered deuterons. A pulse-dilation drift tube (PDDT) subsequently dilates, un-skews, and detects the signal. While the foil and ion-optical system have been designed, the PDDT requires more development before it can be implemented. Therefore, a phased plan is presented that first uses the foil and ion-optical systems with detectors that can be implemented immediately—namely CR-39 and hDISC streak cameras. These detectors will allow the MRSt to be commissioned in an intermediate stage and begin collecting data on a reduced timescale, while the PDDT is developed in parallel. A CR-39 detector will be used in phase 1 for the measurement of the time-integrated neutron spectra with excellent energy-resolution, necessary for the energy calibration of the system. Streak cameras will be used in phase 2 for measurement of the time-resolved spectrum with limited spectral coverage, which is sufficient to diagnose the time-resolved ion temperature. Simulations are presented that predict the performance of the streak camera detector, indicating that it will achieve excellent burn history measurements at current yields, and good time-resolved ion-temperature measurements at yields above 3 × 10 17 . The PDDT will be used for optimal efficiency and resolution in phase 3.

47 OTHER INSTRUMENTATION↗

Multiple RGB ortho-mosaics and digital surface models in 2017 and 2018 across the Lower Montane site in the East River Watershed, Colorado

Aerial imagery was collected at the Lower Montane site (Pumphouse) in the East River Watershed, Colorado during the spring, summer, and fall seasons of 2017 and 2018 to improve the understanding of seasonal vegetation dynamics and their drivers. The datasets include Red-Green-Blue (RGB) ortho-mosaics and digital surface models (DSMs) inferred from the Unoccupied Aerial System (UAS) acquired aerial RGB imagery for June 3, June 19, July 7, and August 14, 2017, and for March 14, April 26, June 1, June 18, July 6, and August 7, 2018. Real-Time Kinematic Global Positioning System (RTK-GPS) surveyed Ground control points (GCPs) were used to increase the reconstruction accuracy. The reconstructed RGB mosaics and DSMs have been trimmed to cover a similar spatial domain. The accuracy of the RGB mosaics is considered high (~10 cm). DSM accuracy is highest (~10 cm) where sufficient GCPS are available, and more difficult to assess elsewhere (see reconstruction reports for uncertainty estimates). The dataset includes a total of 20 GeoTIFF (.tif) files, 10 PDF (.pdf) files, 3 data CSV (.csv) files, and 2 metadata CSV (.csv) files. Feel free to contact the authors with any questions or collaboration interests.This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231.

54 ENVIRONMENTAL SCIENCES↗

Seasonal Evolution of the Subglacial Hydrologic System Modified by Supraglacial Lake Drainage in Western Greenland

The impact of summer surface melt on Greenland Ice Sheet dynamics is modulated by the state of the subglacial hydrologic system. Studies of ice motion indicate that efficiency of the subglacial system increases over the melt season, decreasing the sensitivity of ice motion to surface melt inputs. However, the behavior of the subglacial hydrologic system is complex and some characteristics are still poorly constrained. Here we investigate the coevolution of subglacial hydrology and ice motion in the Pâkitsoq region of western Greenland during the 2011 melt season. We analyze measurements from 11 Global Positioning System stations, from which we derive ice velocity, longitudinal strain rates, and basal uplift, alongside observations of surface ablation and supraglacial lake drainages. We observe ice acceleration after the onset of local surface melting, followed by gradual ice deceleration, consistent with increasing subglacial efficiency. In the study area, supraglacial lake drainages cooccur with a change in regional strain rate patterns and ice deceleration, suggesting that lake drainages contribute to rapid subglacial reorganization. At lower ice surface elevations (below ~900 m above sea level), ice motion is correlated with both total basal uplift and its rate of change, while at higher elevations (~900–1,100 m above sea level), ice motion correlated only with the basal uplift rate. This pattern suggests that continued cavity growth or subglacial sediment dynamics may be important in the apparent increase in subglacial drainage efficiency at higher elevations in the ablation zone. Furthermore, our results further suggest that transient subglacial behavior is important in the seasonal evolution of ice motion.

58 GEOSCIENCES↗

Green Routing Fuel Saving Opportunity Assessment: A Case Study on California Large-Scale Real-World Travel Data

New technologies, such as connected and automated vehicles, have attracted more and more researchers for improving the energy efficiency and environmental impact of current transportation systems. The green routing strategy instructs a vehicle to select the most fuel-efficient route before the vehicle departs. It benefits the current transportation system with fuel saving opportunity through identifying the greenest route. This paper introduces an evaluation framework for estimating benefits of green routing based on large-scale, real-world travel data. The framework has the capability to quantify fuel savings by estimating the fuel consumption of actual routes and comparing to routes procured by navigation systems. A route-based fuel consumption estimation model, considering road traffic conditions, functional class, and road grade is proposed and used in the framework. An experiment using a large-scale data set from the California Household Travel Survey global positioning system trajectory data base indicates that 31% of actual routes have fuel savings potential with a cumulative estimated fuel savings of 12%.

33 ADVANCED PROPULSION SYSTEMS↗

An Aerial Radiological Survey of the Las Vegas Strip and Adjacent Areas

As proficiency training for the Radiological Mapping mission of the Aerial Measuring System (AMS), a survey team from the Remote Sensing Laboratory–Nellis (RSL-Nellis) conducted an aerial radiological survey of the Las Vegas Strip and adjacent areas on December 29, 2008. This survey was one of the bi-annual surveys carried in support of the city of Las Vegas Police Department (LVPD) before significant events on the Las Vegas Strip: e.g., the annual New Year’s Eve and July Fourth celebrations. The AMS operation and appropriate law enforcement agencies selected this area as an appropriate urban location to exercise AMS capability for mapping environmental radiation and searching for man-made radioactive sources. The surveys covered approximately 11 square miles. Each survey required a 2.5-hour-long flight, performed at an altitude of 300 ft above ground level (AGL) at a line spacing of 600 ft. Water line and test line flights are conducted over the Lake Mead and Government Wash areas to determine the non-terrestrial background contributed by aircraft, radon, and cosmic activity, and to determine the altitude-dependent air mass correction. The data were collected by the AMS data acquisition system (REDAR V) using an array of twelve 2" x 4" x 16" sodium iodide (NaI) detectors flown on-board a twin-engine Bell 412 helicopter. Gamma energy spectral data were collected second-by-second over the survey area. This spectral data allows the system to distinguish between natural terrestrial background contributions and man-made radioisotope contributions. Spectral data can also be used to identify specific man-made radioactive isotopes. Data geo-locations were determined with a Real-Time Differential Global Positioning System (RDGPS).

aerial radiological survey, Las Vegas Strip↗

Green Routing Fuel Saving Opportunity Assessment: A Case Study on California Large-Scale Real-World Travel Data: Preprint

New technologies, such as connected and automated vehicles, have attracted more and more researchers for improving the energy efficiency and environmental impact of current transportation systems. The green routing strategy instructs a vehicle to select the most fuel-efficient route before the vehicle departs. It benefits the current transportation system with fuel saving opportunity through identifying the greenest route. This paper introduces an evaluation framework for estimating benefits of green routing based on large-scale, real-world travel data. The framework has the capability to quantify fuel savings by estimating the fuel consumption of actual routes and comparing to routes procured by navigation systems. A route-based fuel consumption estimation model, considering road traffic conditions, functional class, and road grade is proposed and used in the framework. An experiment using a large-scale data set from the California Household Travel Survey global positioning system trajectory data base indicates that 31% of actual routes have fuel savings potential with a cumulative estimated fuel savings of 12%.

33 ADVANCED PROPULSION SYSTEMS↗

Developing and improving a scanning system for dosimetric applications

Radiotherapy is nowadays one of the most used techniques for the treatment of different pathologies, particularly cancer diseases. The accuracy regarding the application of these treatments, which are planned according to patient information, depends mainly on the dosimetric measurements of absorbed dose within irradiated tissues. The present work is devoted to the study, design and construction of an original device capable of performing visible light transmission measurements in order to analyze Fricke gel dosimeters. Furthermore, a suitable bi-dimensional positioning system along with a dedicated control system and image processing software has been adapted to the dosimetric device in order to perform 2D dose mapping. The obtained results confirm the feasibility of the proposed method, therefore suggesting its potentiality for clinical applications.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Region Three Aerial Measurement System Flight Planning Tool - 12006

The Region 3 Aerial Measurement System Flight Planning Tool is used by the National Nuclear Security Agency (NNSA), United States Department of Energy, Radiological Assistance Program, Region 3, to respond to emergency radiological situations. The tool automates the flight planning package process while decreasing Aerial Measuring System response times and decreases the potential for human error. Deployment of the Region Three Aerial Measurement System Flight Planning Tool has resulted in an immediate improvement to the flight planning process in that time required for mission planning has been reduced from 1.5 hours to 15 minutes. Anecdotally, the RAP team reports that the rate of usable data acquired during surveys has improved from 40-60 percent to over 90 percent since they began using the tool. Though the primary product of the flight planning tool is a pdf format document for use by the aircraft flight crew, the RAP team has begun carrying their laptop computer on the aircraft during missions. By connecting a Global Positioning System (GPS) device to the laptop and using ESRI ArcMap's GPS tool bar to overlay the aircraft position directly on the flight plan in real time, the RAP team can evaluate and correct the aircraft position as the mission is executed. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Tracking and Monitoring with Dosimeter-Enabled ARG-US RFID System - 12009

Automated monitoring and tracking of materials with radio frequency identification (RFID) technology can significantly improve both the operating efficiency of radiological facilities and the application of the ALARA (as low as reasonably achievable) principle in them. One such system, called ARG-US, has been developed by Argonne National Laboratory for the U.S. Department of Energy (DOE) Packaging and Certification Program to use in managing sensitive nuclear and radioactive materials. Several ARG-US systems are in various stages of deployment and advanced testing across DOE sites. ARG-US utilizes sensors in the tags to continuously monitor the state of health of the packaging and promptly disseminates alarms to authorized users. In conjunction with global positioning system (GPS) tracking provided by TRANSCOM, the system can also monitor and track packages during transport. A compact dosimeter has been incorporated in the ARG-US tags via an onboard universal asynchronous receiver/transmitter interface. The detector has a wide measurement range for gamma radiation - from 0.1 mSv/h to 8 Sv/h. The detector is able to generate alarms for both high and low radiation and for a high cumulative dose. In a large installation, strategically located dosimeter-enabled tags can yield an accurate, real-time, 2D or 3D dose field map that can be used to enhance facility safety, security, and safeguards. This implementation can also lead to a reduced need for manned surveillance and reduced exposure of personnel to radiation, consistent with the ALARA principle at workplaces. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

SU-E-J-184: Stereo Time-Of-Flight System for Patient Positioning in Radiotherapy

Purpose: The objective of this work is to test the advantage of using the surface acquired by two stereo Time-of-Flight (ToF) cameras in comparison of the use of one camera only for patient positioning in radiotherapy. Methods: A first step consisted on validating the use of a stereo ToFcamera system for positioning management of a phantom mounted on a linear actuator producing very accurate and repeatable displacements. The displacements between two positions were computed from the surface point cloud acquired by either one or two cameras thanks to an iterative closest point algorithm. A second step consisted on determining the displacements on patient datasets, with two cameras fixed on the ceiling of the radiotherapy room. Measurements were done first on voluntary subject with fixed translations, then on patients during the normal clinical radiotherapy routine. Results: The phantom tests showed a major improvement in lateral and depth axis for motions above 10 mm when using the stereo-system instead of a unique camera (Fig1). Patient measurements validate these results with a mean real and measured displacement differences in the depth direction of 1.5 mm when using one camera and 0.9 mm when using two cameras (Fig2). In the lateral direction, a mean difference of 1 mm was obtained by the stereo-system instead of 3.2 mm. Along the longitudinal axis mean differences of 5.4 and 3.4 mm with one and two cameras respectively were noticed but these measurements were still inaccurate and globally underestimated in this direction as in the literature. Similar results were also found for patient subjects with a mean difference reduction of 35%, 7%, and 25% for the lateral, depth, and longitudinal displacement with the stereo-system. Conclusion: The addition of a second ToF-camera to determine patient displacement strongly improved patient repositioning results and therefore insures better radiation delivery.

60 APPLIED LIFE SCIENCES↗

Position and Velocity Tracking in Cellular Networks Using the Kalman Filter

Access to the right information anytime, anywhere is becoming the new driving force for the information technology revolution. The 'right' information's relevance is based on the user's profile and his/her current geographical position and/or time. Location Based Service (LBS) is an innovative technology that provides information or makes information available based on the geographical location of the mobile user. Analysts predict that LBSs will lead to new applications, generating billions of US dollars worldwide (Leite, 2001; Searle, 2001). The need for an efficient and accurate mobile station (MS) positioning system is growing day by day. The ability to pinpoint the location of an individual has an obvious and vital value in the context of emergency services (Chan, 2003; Olama et al., 2008). Pinpointing the location of people and other valuable assets also opens the door to a new world of previously unimagined information services and m-commerce probabilities. For example, availability of services like 'Where is the nearest ATM?', 'Check traffic conditions on the highway on my route', 'Find a parking lot nearby', as well as answers to 'Where is my advisor?', and 'Where is my car?' will be an everyday rule in our lives (Charalambous & Panayiotou, 2004). A technology independent LBS architecture can be considered as comprised by three main parts (Girodon, 2002): A user requesting information, a mobile network operator and its partners, and several content providers (e.g. data, maps). The subscriber requests a personalized service dependant on his geographic location. The system will ask the Location Services Manager (which is in charge of handling requests, i.e., send/receive to the Location Calculator and the Content Providers) to pinpoint the location of the mobile. The Location Services Manager (LSM), using the Location Calculator, will ask the Content Provider (CP) to supply qualified information according to the mobile's geographical position. The LSM will eventually receive the answer from the CP and send it to the mobile, performing the essential data translations. Fig. 1 outlines the precedent concept. For effective provision of LBS, one has to provide an accurate location, as well as suitable information for users required by the corresponding service, with minimal expenditure. Thus, there are three main technology issues that have to be resolved for LBS: positioning technology, application technology, and location services (Dru & Saada, 2001). A very important technology is of course the positioning technology, the way to find out the location of a mobile device accurately. Due to the unique characteristics of the cellular environment, it is a great challenge to locate the user precisely. However, in many cases, application technology and location services are important consideration of LBS. Application technology manages the geographic information and delivers the customer requests to the appropriate service provider, thus it constitutes the communication system involved. LBS uses the geographic information to provide geographically sensitive information and services. Location-based applications and services are not sensitive to the type of location technology that is used - they merely rely on reasonably accurate geographic coordinates (Chan, 2003). This chapter is structured as follows: In Section 2, we describe the use and applications of LBSs. The current location determination technologies and standards are presented in Section 3. In Section 4 we describe the mathematical models used for the location and velocity estimation algorithms. An initial attempt for MS location estimation via received signal level using the maximum likelihood estimation (MLE) approach and triangulation is presented in Sections 5. Since the former approach lacks acceptable accuracy for demanding services as numerical results reveal, the extended Kalman filter (EKF) approach, which is the main topic in this chapter, is introduced in Sections 6. In Section 7 we present numerical results. Section 8 provides concluding remarks.

99 GENERAL AND MISCELLANEOUS↗

Gas temperature and electron density profiles in an argon dc microdischarge measured by optical emission spectroscopy

Optical emisssion spectroscopy was employed to study a high pressure (100 s of Torr), slot-type (600 {mu}m interelectrode gap), argon dc microdischarge, with added traces of nitrogen. Spatially resolved gas temperature profiles were obtained by analyzing rovibrational bands of the N{sub 2} first positive system. The gas temperature peaked near the cathode and increased with current. The contribution of Stark broadening to the hydrogen H{sub {beta}} emission lineshape was used to extract the electron density. The axial distribution of electron density as well as visual observation revealed that the microdischarge positive column was highly constricted. The electron density near the sheath edge increased with both pressure and current.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Radiation of nitrogen molecules in a dielectric barrier discharge with small additives of chlorine and bromine

Spectral and energy characteristics of nitrogen molecule radiation in dielectric barrier discharges in Ar-N{sub 2}, Ar-N{sub 2}-Cl{sub 2}, and Ar-N{sub 2}-Br{sub 2} mixtures were investigated experimentally. Small additives of molecular chlorine or bromine to an Ar-N{sub 2} mixture are found to increase the radiation intensity of the second positive system of nitrogen. The conditions at which the radiation spectrum predominantly consists of vibronic bands of this system are determined. Using a numerical model of plasmachemical processes, it is shown that, at electron temperatures typical of gas discharges (2-4 eV), a minor additive of molecular chlorine to an Ar-N{sub 2} mixture leads to an increase in the concentrations of electrons, positive ions, and metastable argon atoms. In turn, collisional energy transfer from metastable argon atoms to nitrogen molecules results in the excitation of the N{sub 2}(C{sup 3{Pi}}{sub u}) state.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Localization of Southern Resident Killer Whales Using Two Star Arrays to Support Marine Renewable Energy

Tidal power has been identified as one of the most potential commercial-scale renewable energy sources. Puget Sound, Washington, is a potential site to deploy tidal power generating devices. The risk of injury for killer whales needs to be managed before the deployment of these types of devices can be approved by regulating authorities. A passive acoustic system consisting of two star arrays, each with four hydrophones, was designed and implemented for the detection and localization of Southern Resident killer whales. Deployment of the passive acoustic system was conducted at Sequim Bay, Washington. A total of nine test locations were chosen, within a radius of 250 m around the star arrays, to test our localization approach. For the localization algorithm, a least square solver was applied to obtain a bearing location from each star array. The final source location was determined by the intersection of the bearings given by each of the two star arrays. Bearing and distance errors were obtained to conduct comparison between the calculated and true (from Global Positioning System) locations. The results indicated that bearing errors were within 1.04º for eight of the test locations; one location had bearing errors slightly larger than expected due to the strong background noise at that position. For the distance errors, six of the test locations were within the range of 1.91 to 32.36 m. The other two test locations were near the intersection line between the centers of the two star arrays, which were expected to have large errors from the theoretical sensitivity analysis performed.

Passive acoustic system, localization, star array,↗