Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Planning for resiliency”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Hydroclimate-coupled framework for assessing power system resilience under summer drought and climate change

Extreme drought, exacerbated by climate change, increasingly threatens power system resilience, and a systematic assessment of such impacts is challenging due to the unpredictability of drought and their associated modeling complexity. Here, to address the challenge, this research develops a hydroclimate-coupled power system resilience assessment framework that enables systematic modeling of drought and climate change impacts on generation, transmission, and demand sectors. Applying the framework to the 2025 Eastern U.S. power grid — comprising 6,055 at-risk generators — under climate-induced summer drought scenarios (including SSP126, SSP245, SSP370, and SSP585) from 2023 to 2100, the study finds that climate-induced droughts could jeopardize the power system’s reliability to a greater extent than historical events, potentially leading to widespread load shedding. More specifically, the study reveals that under the twenty-one representative drought scenarios, the loss of load expectation (LOLE) of the grid could range from 34.77 to 91.48 days per summer. The simulations indicate that implementing resilience enhancement strategies is crucial to ensure reliable system operation, which encompasses initiatives such as demand response, upgrading open cooling systems, and transmission expansion. In all, these findings underscore the urgent need for proactive planning and investment in resilient U.S. power systems to mitigate the impacts of extreme drought events.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Lessons Learned from the Clean Energy to Communities (C2C) Peer-Learning Cohort Evaluating and Prioritizing Municipal Buildings for Energy Efficiency and Decarbonization Investment

The National Renewable Energy Laboratory (NREL), with support from World Resources Institute (WRI), designed and led a six-month peer-learning cohort from January through July 2024 on "Enhancing Resilience at Critical Facilities through Solar, Storage, and Microgrids" as part of the U.S Department of Energy's Clean Energy to Communities (nrel.gov/c2c) (C2C) program. Representatives from 15 municipalities, municipal utilities, colleges, and Tribes from across the United States participated in monthly workshops covering best practices for planning and deploying local resilience projects. This document shares key takeaways, lessons learned, and resources from the cohort.

buildings↗

Exploring acute weather resilience: Meeting resilience and renewable goals

We report the United States is affected by an average of almost seven severe weather events a year, often resulting in billions of dollars in physical and economic damages, a subset of which are related to grid outages. There is a need for power and energy system stakeholders to better understand and implement the strategies that help reduce net-economic and societal consequences associated with grid outages by improving the resilience of their systems. In addition, there are incentives to reduce emissions and meet climate goals, several pathways of which include resilient technologies. Including resilience constraints and metrics in energy system planning models may help inform the design of more resilient systems that are also more renewable and sustainable. This paper reviews qualitative definitions of resilience, quantitative approaches to resilience, recent examples of the inclusion of resilience in energy system models with respect to acute climatological threats, and the gaps in fully articulating resilience in current modeling tools. We then outline steps to effectively improve resilience considerations against such threats into energy sector modeling tools. Based on the findings, the authors propose a novel framework for energy system resilience assessment and future areas of research to bridge the current modeling gaps.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Integrated Metrics for County-Level Resilience Ranking Using Entropy and TOPSIS

In the face of atypical weather events, power infrastructure failures, and limited resources for resilience investment, energy decision-makers need data-driven metrics to allocate resilience investments and maximize the reduction of power outage impacts. For state-level planning, for instance, ranking the resilience of each county is key to ensuring effective distribution of resources. In such cases, resilience for each spatial unit is multifaceted and is captured by a set of indicators (i.e., metrics) that can be combined into an overall score that reduces the complexity of power outage dynamics to a single decision metric. However, weighting of these indicators is often addressed by simplifying assumptions (i.e., equal weights) or semi-subjective methods that rely on user-defined weights that can introduce biases (e.g., weighted average score). Within the disaster risk reduction and resilience engineering community, a recurring challenge in multicriteria decision-making is the objective weighting of indicators for composite indices. To address this issue, we have leveraged a Technique for Order of Preference by Similarity to Ideal Solution (TOPSIS) combined with an entropy-based weighting approach to calculated the integrated scores. This method objectively determines the importance of each metric, better discerns between spatial units (i.e., counties), and offers a more reliable ranking of counties according to their relative resilience attributes. By improving methods for integrating resilience indicators, our approach helps planners and decision-makers prioritize resources more effectively for more efficient resilience investments.

Bhusal, Narayan [Oak Ridge National Laboratory (OR↗

Planning decentralized urban renewable energy systems using algal cultivation for closed-loop and resilient communities

To tackle climate challenges, communities need to harvest renewable energy and resources on site locally to close the loops for enhancing the resilience of communities facing unpredictable and uncertain future changes. A decentralization planning of urban renewable energy systems is proposed by treating urban waste streams and producing biomass through applying algal biotechnology. When applying algal technology as a renewable and decentralized energy source in urban systems, the overall performance can vary by levels of urban nutrients, solar and CO 2 resources, and the transportation cost when considering its application to different urban densities, urban form, and the spatial scale of urban settings. This research explores three potential impacts on the algal system’s energy performance: (1) urban density, (2) urban form in different contexts, and (3) spatial scale. The research examines the impacts by testing urban settings given in actual contexts in Atlanta, Georgia, USA. Four neighborhoods representing the high-density urban, mid-density urban, mixed suburban, and typical suburban areas are investigated. The density-scale–performance relationships are explored through testing different urban forms of neighborhoods in both hypothetical and actual neighborhood settings. A GIS-based model is developed to estimate the overall energy performance of the decentralized renewable energy system in urban environments. Results show that the energy performance is positive mainly for high-density urban neighborhoods with small-to-medium scales, up to 0.36 MJ per ton of municipal solid wastes for actual settings and 0.37 MJ for hypothetical cases. Neighborhoods with higher density have higher energy performance while up scaling has negative effects on the energy performance with a low degree of significance. Optimal scales are found as a 1-km radius in real test beds and 1.3 km in hypothetical settings, in which the results show trade-offs between scaling effects in the system efficiency gain and the transportation cost increase.

Quan, Steven Jige↗

Minneapolis American Indian Center Solar + Battery Resilience Hub

To meet south Minneapolis, Minnesota's clean energy goals, the community exploring opportunities to transition Minneapolis American Indian Center (MAIC) into a resilience hub to provide critical community services during power outages, including shelter and warmth or cooling, continued food distribution services, and more. The National Renewable Energy Laboratory, through the U.S. Department of Energy's Communities LEAP (Local Energy Action Program) pilot, worked with MAIC to quantify the costs and benefits of installing stand-alone solar photovoltaics (PV) and PV paired with battery systems to reduce energy costs, avoid emissions, and improve resilience.

BESS↗

Risks to the DOW Mission From Global Advanced Energy Adoption

Advanced energy technologies have the potential to enhance energy security and resilience; however, they can introduce new vulnerabilities even as they mitigate existing ones. This dichotomy highlights that both action and inaction carry strategic risks in a contested and logistically complex operating environment. Regardless of U.S. civilian or military adoption of such technologies, key allies and adversaries are on adoption paths that will impact the U.S. military at the tactical, operational, and strategic level. The global adoption of advanced energy technologies presents the potential for both positive and negative consequences for U.S. Department of Defense (DOD) missions in the next 10-20 years. Three categories of risk drivers are presented in this analysis: infrastructure-related, adoption-related, and response-related. Each risk type can generate consequences for DOD, including power disruptions, suboptimal DOD mission performance and operational effectiveness, higher costs and shortages for both legacy and advanced energy technologies, and loss of U.S. influence and strategic deterrent value. Specific impacts could include tactical impacts, operational impacts, and strategic impacts. Mitigation strategies could include energy resource and technology planning, cybersecurity, supply chain resilience, workforce development, exercises and simulations, investments in commercialized technology, operational testing and pilot programs, research into emerging technologies, partnerships and working groups, common standards, budget planning, and repurposing infrastructure.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Enhancing Power Grid Resilience with Causal Loops Diagram and Bayesian Networks

Enhancing power grid resilience through improved analysis and planning of Distributed Energy Resources is a key for power system planner. This paper explores the integration of Causal Loop Diagrams (CLDs) and Bayesian Networks (BNs) for enhancing resilience in power systems, focusing on Distributed Energy Resources (DER) planning. By automating CLD analysis in Python's matplotlib, we present a tool for rapid model validation and structural accuracy, crucial for power system planners. This hybrid approach utilizes BNs for inferential depth and CLDs for dynamic system modeling, offering a comprehensive framework for policy formulation and collaborative strategy development against disruptions. Here, we highlight the tool's capability to identify and analyze interconnected feedback loops, facilitating a deeper understanding of DER integration's impact on network resilience. This work aims to bridge quantitative analysis and qualitative insights, addressing the limitations of each method while providing a robust model for power system resilience assessment.

14 SOLAR ENERGY↗

Commentary: Our “heatshed” moment is now

We are living through a “heatshed” moment, a critical turning point in which heat must be rapidly addressed to protect health and livelihoods worldwide. The year 2024 was the hottest on record since global records began in 1850, and the past 10 years were the hottest decade in recorded history. Although extreme heat is the top weather-related killer in the United States, affecting livelihoods and economies, cities and nations dedicate more attention and resources to other climate hazards, such as hurricanes, floods, droughts, and wildfires. In this commentary, we argue that heat resilience must be rapidly advanced through heat mitigation, heat management, and heat governance efforts to ensure thriving communities in the face of an overheating world.

Extreme heat↗

Permanent Magnet Resiliency in Jefferson Lab’s Radiation Environment: LDRD Grant Status and Plans

As the FFA@CEBAF energy upgrade study progresses, it is important to investigate the impact of radiation exposure on the permanent magnet materials to be used in the upgraded fixed field alternating gradient (FFA) arcs. To address this, Jefferson Lab has awarded a Laboratory Directed Research and Development (LDRD) grant to study the resiliency of several permanent magnet materials placed in a radiation environment similar to that in which they are expected to operate. Samples of NeFeB and SmCo are to be placed alongside appropriate dosimetry in a variety of radiation environments in the beam enclosure and experimental halls at CEBAF. The magnet degradation will be measured, and extrapolated to the higher energies expected during operations after the energy upgrade. This document will describe the current status of the LDRD study, as well as describe the upcoming plans. It will also direct the readers to other proceedings which further detail the work thus far.

Bodenstein, R.↗

Community Resilience Options: A Menu for Enhancing Local Energy Resilience

This document highlights areas of potential community resilience improvements, especially those that relate to clean energy deployment for communities and municipalities. The National Renewable Energy Laboratory (NREL) defines resilience as "a system's ability to anticipate, prepare for, and adapt to changing conditions and withstand, respond to, and recover rapidly from disruptions through sustainable, adaptable, and holistic planning and technical solutions." This document introduces 10 categories of resilience-enhancing projects at a high level, intended for community members and decision-makers new to the topic to build their understanding of which solutions fit their community best. These categories focus primarily on community-scale measures and different options may be available at larger scales. Full implementation of the measures described here requires in-depth, site-specific considerations that go beyond the scope of this document.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

U.S. Industrial and Commercial Motor System Market Assessment Report Volume 1: Characteristics of the Installed Base

Motor systems are an integral part of our industrial and commercial facilities. They provide the motive force behind the fans, pumps, compressors, chillers, and conveyors in these facilities. Given their centrality to any facility’s operations, they are a critical energy end use to understand, particularly when developing technologies and policies to meet sustainability goals, improve productivity, and enhance resilience. In the late 1990s, the U.S. Department of Energy (DOE) conducted two seminal studies to better understand the installed stock and energy savings opportunities of industrial and commercial motor systems. In the industrial sector, The United States Industrial Electric Motor Systems Market Opportunities Assessment used primary data collected through onsite assessments and led to a greater understanding of the installed base of motor systems, their characteristics, and the opportunities for energy savings (U.S. Department of Energy, 2002). Notable findings included the following: Industrial motor systems consumed 679 billion kilowatt-hours (kWh) in 1994, representing 23 percent of U.S. electricity consumption. Cost-effective energy efficiency measures could result in 62-104 billion kWh of energy savings annually. Sixty-two percent of the energy savings potential was from fan, pump, and compressor end use equipment. Nearly half of motor system electricity consumption was attributable to approximately 3,500 facilities, or 1.5 percent of U.S. manufacturing facilities. Opportunities for Energy Savings in the Residential and Commercial Sectors with High Efficiency Electric Motors provided an evaluation of the installed stock of motor driven equipment in U.S. commercial and residential buildings and opportunities for utilization of high efficiency motors and variable speed technologies (Arthur D. Little, 1999). Notable findings included the following: Commercial motor systems consumed 343 billion kWh in 1995, with refrigeration and space conditioning constituting 93 percent of the total. Cost-effective energy efficiency measures could result in 51 billion kWh of energy savings annually. Due in no small part to these seminal studies, motor system technologies and usage characteristics have changed drastically since the late 1990s. Greater awareness of cost-effective strategies for reducing motor system electricity consumption have been developed and deployed. This includes several software tools, literature, and utility and government programs promoting energy efficiency improvements in motor driven systems. Additionally, several rounds of energy efficiency standards have been enacted, resulting in improved installed motor efficiency. The cost of variable speed drives has dropped substantially, and combined with utility rebate programs, has led to their greater adoption. Further, since these results were published, the U.S. manufacturing sector has undergone a massive transformation. Due to global competition, some sectors have relocated operations overseas. Others have brought operations onshore to avail low cost and abundant natural gas. Additionally, automation and robotics have pervaded the entire sector. Consequently, these two reports likely do not represent the current state of motor driven systems in U.S. industrial and commercial facilities. As cited in recent studies, the lack of current information on motor system electricity consumption and use characteristics limits the ability to conduct analysis on energy savings potential, develop technologies to address energy and productivity gaps, and develop programs to promote energy efficiency practices and technologies for motor systems (International Energy Agency, 2007; UNIDO, 2010; McKane and Hasanbeigi, 2011; Waide and Brunner, 2011). Specifically, the lack of information affects a range of stakeholders: Governments must rely on outdated information when setting research agendas, developing policies, and designing energy efficiency programs and offerings. Utilities and energy efficiency programs cannot identify the current market needs or potential impact when designing rebate and energy efficiency programs. Electric grid planners cannot identify motor system usage characteristics when developing plans to support the resilience of the electric grid. Manufacturers of motors, motor driven equipment, and drives are hampered when developing technologies to meet the needs of their market. Motor system end users are limited in their ability to identify energy saving opportunities within their own facilities because they do not have reliable benchmark information. In response to the lack of current information and analysis on industrial and commercial motor systems, the DOE initiated an update to these two studies. Launched in 2016 and led by Lawrence Berkeley National Laboratory (LBNL), the Motor System Market Assessment (MSMA) provides an updated, more comprehensive assessment of the installed stock of motor systems in both the industrial and commercial sectors, a review of the supply chains supporting motor and drives in the U.S., and the performance improvement opportunity available from using best available technologies and maintenance and operation practices. The outcomes of the MSMA are documented in three U.S. Industrial and Commercial Motor System Market Assessment reports, with this report being the first listed: 1. Volume 1: Characteristics of the Installed Base (this report) documents the findings on the installed base of motor systems in the U.S. industrial and commercial sectors. Quantification of energy savings potential is not documented in this report but in Volume 3. 2. Volume 2: Motors and Drives Supply Chain Review reviews the state of supply chains for motors and drives installed in U.S. industrial and commercial facilities, focusing on advanced motor and drive technologies and their constituent materials. 3. Volume 3: Energy Savings Opportunity analyzes the energy performance improvement opportunity for the installed base of U.S. industrial and commercial motor systems. This report has been prepared as a reference for motor system stakeholders. It provides factual information as could be best determined by the assessment results and avoids speculating on any findings.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Improving energy efficiency while reducing anthropogenic heat from buildings: how retrofits influence the building stock and urban microclimate in Los Angeles

Anthropogenic heat (AH) from buildings contributes to urban overheating, especially during heat waves, yet building retrofit studies usually evaluate energy savings without assessing impacts on AH. This study quantifies how common building retrofit measures affect both building energy use and AH emissions across the City of Los Angeles. Using a bottom-up urban building energy modeling framework coupled with high-resolution local weather from the Weather Research and Forecasting model with Building Effect Parameterization (WRF-BEP), we evaluate eleven retrofit measures and two multi-measure retrofit packages. HVAC and LED lighting retrofits provide the largest city-wide annual site energy savings, while roof coating is most effective for reducing AH. A package optimized for energy savings reduces summer site energy use by about 32% (2.3 TWh), while a package incorporating AH-focused measures reduces the total AH by over 50% (137 PJ) with minimal difference in energy savings. The AH-aware package produces substantially greater urban cooling, reducing mean near-surface air temperature by up to 0.62 ℃ and peak temperature by up to 3.79 ℃. These results show that retrofit strategies selected only for energy savings may overlook major opportunities for urban heat mitigation. The study provides a framework for integrating AH into building retrofit planning and urban heat resilience policy.

Anthropogenic heat↗

Proactive Operations and Investment Planning via Stochastic Optimization to Enhance Power Systems’ Extreme Weather Resilience

We present scalable stochastic optimization approaches for improving power systems’ resilience to extreme weather events. We consider both proactive redispatch and transmission line hardening as alternatives for mitigating expected load shed due to extreme weather, resulting in large-scale stochastic linear programs (LPs) and mixed-integer linear programs (MILPs). We solve these stochastic optimization problems with progressive hedging (PH), a parallel, scenario-based decomposition algorithm. Our computational experiments indicate that our proposed method for enhancing power system resilience can provide high-quality solutions efficiently. With up to 128 scenarios on a 2,000-bus network, the operations (redispatch) and investment (hardening) resilience problems can be solved in approximately 6 min and 2 h of wall-clock time, respectively. Additionally, we solve the investment problems with up to 512 scenarios, demonstrating that the approach scales very well with the number of scenarios. Moreover, the method produces high quality solutions that result in statistically significant reductions in expected load shed. Our proposed approach can be augmented to incorporate a variety of other operational and investment resilience strategies, or a combination of such strategies.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Planning for cooler communities: Vacant lots as components of heat resilience in Mesa, Arizona

Vacant lots are often perceived as contributing to negative socioeconomic and environmental impacts on surrounding communities. However, they also offer opportunities for strategic interventions that promote heat resilience. This study uses a decision-scale congruence analytic approach to examine the correlation between extreme heat and community resilience in the context of vacant lots in the city of Mesa, Arizona. By identifying and analyzing over 1,200 vacant lots, we assessed spatial patterns of Community Resilience Estimates (CRE) for Heat and Body Heat Storage (BHS) to understand their correlation at the unit of analysis of vacant lots, where key decisions are made concerning land use. The results reveal a nonrandom spatial distribution of CRE for Heat and BHS across Mesa’s vacant lots. Vacant lots are disproportionately concentrated in neighborhoods with lower resilience, exacerbating heat exposure. Communities with limited access to cooling infrastructure, tree canopy, and other resources experience lowered heat resilience. A positive correlation between CRE for Heat and BHS shows that areas with higher heat exposure tend to have lower community resilience, reinforcing the need for cooling interventions. This study highlights the potential for converting vacant lots into heat-resilient, community-serving spaces. Using our findings, decision makers can identify priority areas and leverage vacant lots to mitigate heat impacts and foster community resilience.

community resilience↗

Watershed response of the Feather River Basin, California, United States of America to future climate changes

Increasing mean annual temperatures under climate change are expected to reduce seasonal snowpack, increase evapotranspiration (ET), and alter summer baseflow in headwater watersheds worldwide. Strong regional variability in hydrologic responses highlights the need for catchment-scale, physically based models to assess future flood risk and water availability. This study examines climate-driven changes in the hydrologic response of the Upper Feather River watershed in the Sierra Nevada Mountains, California. Four priority climate models and two representative concentration pathways (RCP4.5 and RCP8.5) are used to evaluate future hydrologic responses of the watershed. Hydrologic processes are simulated using an objectively calibrated Soil and Water Assessment Tool Plus model for a historical baseline (1986–2005) and a future period 2070–2099), driven by observed and projected precipitation and temperature. Results indicate a declining contribution of snowfall to annual precipitation, with peak snowfall and water yield shifting 1–3 months earlier. Long-term annual maximum flows are projected to increase considerably, whereas low-flow responses are mixed, with both increases and decreases projected by the end of the century. These findings highlight the need for adaptive watershed management to enhance flood protection, water storage, and drought resilience. Future water resource planning should also account for one-to-three-month shifts in peak water yield and surface runoff due to changes in snowmelt timing and a lower snowfall-to-rainfall ratio under climate change. The modeling framework and insights are transferable to other snow-dominated headwater watersheds experiencing climate-driven change.

Tigabu, T [UC Davis]↗