Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Planar Laser Induced Fluorescence”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Planar temperature measurement in compressible flows using laser-induced iodine fluorescence

A laser-induced iodine fluorescence technique that is suitable for the planar measurement of temperature in cold nonreacting compressible air flows is investigated analytically and demonstrated in a known flow field. The technique is based on the temperature dependence of the broadband fluorescence from iodine excited by the 514-nm line of an argon-ion laser. Temperatures ranging from 165 to 245 K were measured in the calibration flow field. This technique makes complete, spatially resolved surveys of temperature practical in highly three-dimensional, low-temperature compressible flows.

Hartfield, Roy J., Jr.↗

Temporal evolution of scalar modes in Richtmyer–Meshkov instability of inclined interface using high-speed PIV and PLIF measurements at 60 kHz

Abstract The current work presents simultaneous, high-speed measurements at 60,000 fields per second of velocity and mole fraction using particle image velocimetry (PIV) and planar laser induced acetone-fluorescence in a Richtmyer–Meshkov instability of an inclined interface (Atwood number, At = 0.22). Specifically, around 2 ms of temporal evolution of the vortex structures and their associated scalar modes immediately following the interface-reshock interaction is presented. Two initial interface conditions are discussed—(a) a sharp, inclined ‘single mode’ interface and (b) a ‘multi-mode’ interface where small perturbations are imposed on the single mode case. A 2D wavelet decomposition of the scalar flow field shows a highly intermittent distribution of small-scale variance throughout the interface even at late times. These are correlated strongly with the vortex structures and local turbulence intensity, where each small-scale scalar mode is sandwiched between two co-rotating vortex structures. This indicates that the interstitial regions between the vortices are significant hotspots of entrainment, which is then dispersed by the induced, counter-flow velocity fields. The multimode case demonstrates similar organization at large scales, while the scalar field is much more homogeneous at smaller scales. These observations highlight the importance of capturing the early time vortex evolution to accurately estimate any late time intermittency, especially where deposition of intense vorticity on sharp interfaces is present.

Engineering↗

Experimental and numerical study of swept ramp injection into a supersonic flowfield

Time-averaged measurements of pressure, temperature, velocity, and injectant mole fraction are presented using the planar laser-induced iodine fluorescence (PLIIF) techniques in the complex 3D compressible flowfield around a swept ramp fuel injector. Within the range of thermodynamic conditions present in the test case studied, the technique's accuracy is estimated to be 4 percent for pressure, 4 percent for temperature, 4 percent for velocity, and 3 percent for injectant mole fraction. Comparisons to numerical simulations using the SPARK 3D Navier-Stokes computer code with an algebraic turbulence model are made at the centerplane of the flowfield as well as on three crossflow planes downstream of the injector, and good agreement is found. A weak asymmetry in the incoming flowfield appears to be amplified by boundary layer separation occuring when the the ramp generated shock reflects off the tunnel walls. In the near field of the injector, laminar calculations show better agreement to the measurements than turbulent calculations.

Donohue, James M.↗

Experimental and numerical study of swept ramp injection into a supersonic flowfield

Time-averaged measurements of pressure, temperature, velocity, and injectant mole fraction are presented using the planar laser-induced iodine fluorescence technique in the complex three-dimensional compressible flowfield around a swept ramp fuel injector. Within the range of thermodynamic conditions present in the test case studied, the technique's accuracy is estimated to be 4% for pressure, temperature, and velocity and 3% for injectant mole fraction. Comparisons with numerical simulations using the SPARK three-dimensional Navier-Stokes computer code with an algebraic turbulence model are made at the centerplane of the flowfield as well as on three crossflow planes downstream of the injector. Calculations and measurements are in good agreement throughout the flowfield, with deviations on the order of 5%; however, in specific regions, such as in the base of the ramp, deviations are larger. A weak asymmetry in the incoming flowfield appears to be amplified by boundary-layer separation occurring when the ramp-generated shock reflects off the tunnel walls. Ramp-generated vortices are weaker in the calculated results due to the effects of numerical viscosity in the vortex cores. This leads to less turning and mixing of the jet plume than observed in the experiments. The rate of decay of the maximum injectant mole fraction with streamwise distance is greater for the present ramp injection scheme than for previously measured transverse injection schemes. In this recirculation region at the base of the injector, laminar calculations show better agreement with the measurements than turbulent calculations.

Donohue, James M.↗

Planar measurement of flow field parameters in a nonreacting supersonic combustor using laser-induced iodine fluorescence

A nonintrusive optical technique, laser-induced iodine fluorescence, has been used to obtain planar measurements of flow field parameters in the supersonic mixing flow field of a nonreacting supersonic combustor. The combustor design used in this work was configured with staged transverse sonic injection behind a rearward-facing step into a Mach 2.07 free stream. A set of spatially resolved measurements of temperature and injectant mole fraction has been generated. These measurements provide an extensive and accurate experimental data set required for the validation of computational fluid dynamic codes developed for the calculation of highly three-dimensional combustor flow fields.

Hartfield, Roy J., Jr.↗

KrF laser-induced OH fluorescence imaging in a supersonic combustion tunnel

Planar fluorescence images of OH in a continuous-flow, electrical-resistively heated, high enthalpy, hydrogen-air combustion tunnel, induced by a tunable KrF laser, were recorded. These images were compared to previously recorded fluorescence images induced by a doubled-dye laser under similar conditions. Images induced by the doubled-dye laser system demonstrated a severe distortion caused by absorption and fluorescence trapping. By contrast, images of the fluorescence induced by the tunable KrF laser retained the symmetry properties of the flow. Based on signal-to-noise ratio measurements the yield of the fluorescence induced by the doubled-dye laser is larger than the fluorescence yield induced by the KrF laser. The measurements in the present facility of OH fluorescence induced by the KrF laser were limited by the photon-statistical noise. Based 2 on this result, doubled-dye laser systems are recommended for OH imaging in small and OH lean (less than 10 exp 15/cu cm) facilities. KrF lasers should be selected otherwise.

Quagliaroli, T. M.↗

High-fidelity Experiments of Turbulent Buoyant Jets from Simultaneous Particle Image Velocimetry and Laser Induced Fluorescence

Accurate models of turbulent buoyant flows are essential for the design of nuclear reactors thermal hydraulics and passive safety systems. However, available models fail to fully capture the physics of turbulent mixing when buoyancy becomes predominant with respect to momentum. Therefore, high-fidelity experiments of well-controlled fundamental flows are needed to develop and validate more accurate models. We performed experiments of positive and negative turbulent buoyant jets, both in uniform and stratified environments, with the aim of understanding the thermal hydraulics of turbulent mixing with variable density and providing high-fidelity data for the development and validation of turbulence models. Non-intrusive, simultaneous Particle Image Velocimetry and Laser Induced Fluorescence measurements were carried out to acquire instantaneous velocity and concentration fields on a vertical section parallel to the axis of a jet in the self-similar region. The Refractive Index Matching method was applied to measure high-resolution buoyant jets with up to 8.6% density difference. These data are free of the typical errors that characterize optical measurements of buoyancy driven flows (e.g., natural and mixed convection) where the refractive index of the fluid is inhomogeneous throughout the measurement domain. Turbulent statistics and entrainment of buoyant jets in uniform and stratified environments are presented. These data are compared with non-buoyant jets in uniform environment, as a reference to investigate the effects of buoyancy and stratification on turbulent mixing. The results will be used for the assessment of current turbulence models and as basis for the development of a new one that captures turbulent mixing.

42 ENGINEERING↗

Microsecond Lifetime Nitric Oxide MTV with 1+1 REMPI

Long-lived NO fluorescence with a lifetime of several microseconds is demonstrated for MTV using an efficient 1+1 resonant-enhanced-multiphoton-ionization (REMPI) process. This measurement technology is particularly applicable to high-speed flows under a wide pressure range.

Molecular Tagging Velocimetry↗

Velocity visualization in gaseous flows

Techniques are established for visualizing velocity in gaseous flows. Two approaches are considered, both of which are capable of yielding velocity simultaneously at a large number of flowfield locations, thereby providing images of velocity. The first technique employs a laser to mark specific fluid elements and a camera to track their subsequent motion. Marking is done by laser-induced phosphorescence of biacetyl, added as a tracer species in a flow of N2, or by laser-induced formation of sulfur particulates in SF6-H2-N2 mixtures. The second technique is based on the Doppler effect, and uses an intensified photodiode array camera and a planar form of laser-induced fluorescence to detect 2-d velocities of I2 (in I2-N2 mixtures) via Doppler-shifted absorption of narrow-linewidth laser radiation at 514.5 nm.

Hanson, R. K.↗

Advanced Non-Intrusive Instrumentation for Propulsion Engines

Changes in engine technology such as higher temperatures, higher tip speeds, new metal/composite/ceramic materials together with radical changes in design philosophy will require amongst other prerequisites the ability to measure and to monitor key internal gas and structural characteristics. The symposium papers presented non-intrusive measurement and analysis technologies in the following categories: Laser Point Measurements (11); Absorption and Infrared Techniques (4); Paints - Surface Sensors (6); Laser Induced Fluorescence (6); Mechanical (7); Films (5); Laser Planar Measurement (9); and a Keynote Address.

Propulsion↗

Tomographic optical emission spectroscopy of atmospheric pressure plasma interacting with complex surfaces

Plasma distribution in 3D space is heavily influenced by complex surfaces and the coupling interactions between plasma properties and interfacing material properties. For example, guided streamers that transition to surface ionization waves (SIWs) and propagate over structured dielectrics experience field enhancements that can lead to localized increases in ionization rates and complex 3D configurations that are difficult to analyze. Investigating these configurations requires techniques than can provide a more complete 3D picture. To help address this capability gap, a tomographic optical emission spectroscopy (tomo-OES) diagnostic system has been developed at Sandia National Laboratories that can resolve SIWs. The system includes four intensified cameras that measure the angular projections of the plasma light emission through bandpass filters. A dot calibration target co-registers each angular projection to the same voxel grid and an algebraic reconstruction technique (ART) recovers the light intensity at each voxel. An atmospheric pressure plasma jet (APPJ), provided by Peter Bruggeman, has been investigated and representative results are shown in Figure 1. Here, a bandpass filter was used to isolate emission from the N 2 second positive system (SPS) at 337.1 nm to capture the transition of the streamer to SIW on a planar dielectric surface (relative permittivity 3.3) located 3 mm below the APPJ [3]. The surface wave velocity was 3.5x10 4 (m/s), consistent with measurements made by Steven Shannon. Characterization of this APPJ will support the group effort of standing up a reproducible APPJ across institutions for applications such as liquid treatment, catalysis, and plasma aided combustion. Future work will investigate non-planar surfaces and eventually develop tomographic laser-induced fluorescence (tomo-LIF) approaches.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Optical Diagnosis of Gas Turbine Combustors Being Conducted

Researchers at the NASA Glenn Research Center, in collaboration with industry, are reducing gas turbine engine emissions by studying visually the air-fuel interactions and combustion processes in combustors. This is especially critical for next generation engines that, in order to be more fuel-efficient, operate at higher temperatures and pressures than the current fleet engines. Optically based experiments were conducted in support of the Ultra-Efficient Engine Technology program in Glenn's unique, world-class, advanced subsonic combustion rig (ASCR) facility. The ASCR can supply air and jet fuel at the flow rates, temperatures, and pressures that simulate the conditions expected in the combustors of high-performance, civilian aircraft engines. In addition, this facility is large enough to support true sectors ("pie" slices of a full annular combustor). Sectors enable one to test true shapes rather than rectangular approximations of the actual hardware. Therefore, there is no compromise to actual engine geometry. A schematic drawing of the sector test stand is shown. The test hardware is mounted just upstream of the instrumentation section. The test stand can accommodate hardware up to 0.76-m diameter by 1.2-m long; thus sectors or small full annular combustors can be examined in this facility. Planar (two-dimensional) imaging using laser-induced fluorescence and Mie scattering, chemiluminescence, and video imagery were obtained for a variety of engine cycle conditions. The hardware tested was a double annular sector (two adjacent fuel injectors aligned radially) representing approximately 15 of a full annular combustor. An example of the two-dimensional data obtained for this configuration is also shown. The fluorescence data show the location of fuel and hydroxyl radical (OH) along the centerline of the fuel injectors. The chemiluminescence data show C2 within the total observable volume. The top row of this figure shows images obtained at an engine low-power condition, and the bottom row shows data from a higher power operating point. The data show distinctly the differences in flame structure between low-power and high-power engine conditions, in both location and amount of species produced (OH, C2) or consumed (fuel). The unique capability of the facility coupled with its optical accessibility helps to eliminate the need for high-pressure performance extrapolations. Tests such as described here have been used successfully to assess the performance of fuel-injection concepts and to modify those designs, if needed.

Hicks, Yolanda R.↗

A Detailed Investigation of Staged Normal Injection into a Mach 2 Flow

A study of the staged injection of two jets of air behind a rearward facing step into a Mach 2 flow was performed using the SPARK 3-D Navier-Stokes code. Calculated mole fraction distributions were compared with an extensive set of planar mole fraction measurements made with a laser induced iodine fluorescence technique. A statistical measure, the standard deviation, was used to help assess agreement between calculation and experiment. Overall, good agreement was found between calculated and measured values. Generally, agreement was better in the far field of the injectors. The effect of grid resolution was investigated by calculating solutions on grids of 60,000, 200,000, and 450,000 points. Differences in the solutions on the two finer grids were small. However, the mole fraction distributions were distinguishable. The effect of turbulence modeling was investigated by employing three different algebraic models for the jet turbulence: the Baldwin-Lomax model, the Prandtl mixing length model, and the Eggers mixing length model. Overall, the Eggers mixing length model was found to be superior for this case. Finally, the effect of the jet exit conditions was examined. A recently proposed Mach number distribution at the jet exit was found to slightly improve agreement between measurement and calculation.

Eklund, Dean R.↗

I.1 Heavy-Duty Diesel Combustion (Sandia National Laboratories)

Regulatory drivers and market demands for lower pollutant emissions, lower carbon dioxide emissions, and lower fuel consumption motivate the development of cleaner and more fuel-efficient engine operating strategies. Most current production heavy-duty diesel engines use a combination of both in-cylinder and exhaust emissions-control strategies to achieve these goals. The emissions and efficiency performance of in-cylinder strategies depend strongly on flow and mixing processes that can be influenced by using multiple fuel injections. Past work performed under this project showed that adding a second injection can reduce soot to levels below what would have been produced by an unchanged first injection, thereby increasing load while decreasing soot and potentially reducing brake specific fuel consumption. Information characterizing the important in-cylinder processes with multiple injections has been gleaned from ensemble-averaged planar laser-induced incandescence (PLII) imaging visualizing the soot cloud and planar induced fluorescence (PLIF) of OH characterizing the soot oxidation regions. PLII showed a consistent disruption of the first injection soot cloud by the second injection. In conjunction with OH-PLIF, differences in soot oxidation patterns for multiple injections compared to single injections were observed. This understanding was further enhanced in FY20, when high-speed imaging resolving the above-mentioned effects in a single cycle were combined with direct numerical simulations investigating the multiple-injection ignition process on the microscopic level of turbulence and chemistry interaction. In FY21, these findings in conjunction with findings from other researchers published in the scientific literature were composed into a preliminary multiple-injection conceptual model of fuel-mixing, injection and ignition processes. Remaining key research questions were also highlighted. In addition, wall heat flux was investigated experimentally and with numerical simulations to understand the potential of multiple injections to reduce the engine heat losses and further enhance the efficiency.

33 ADVANCED PROPULSION SYSTEMS↗

Two-dimensional imaging of molecular hydrogen in H2-air diffusion flames using two-photon laser-induced fluorescence

The use of a tunable ArF laser at 193.26 nm to record simultaneous single-laser-shot, planar images of molecular hydrogen and hot oxygen in a turbulent H2-air diffusion flame. Excitation spectra of fuel and oxidant-rich flame zones confirm a partial overlap of the two-photon H2 and single-photon O2 Schumann-Runge absorption bands. UV Rayleigh scattering images of flame structure and estimated detection limits for the H2 two-photon imaging are also presented.

Lempert, W.↗

Quantitative investigation of compressible mixing: Staged transverse injection into Mach 2 flow

Planar measurements of the injectant mole fraction distribution and the velocity field within a supersonic mixing flowfield have been made using laser-induced iodine fluorescence. The flowfield investigated in this work is staged transverse injection of air into a Mach 2 freestream. A complete three-dimensional survey of the injectant mole fraction distribution has been generated, and a single planar velocity measurement has been completed. The measurements reveal the dramatic effect of streamwise vortices on the mixing in the near field of the injectors, as well as the rapid mixing generated by staging two fuel injectors. Analysis of the downstream decay of the maximum injectant mole fraction in this and other supersonic mixing flowfields indicates that the relative rate of injectant mixing well downstream of the injectors is independent of injection geometry, freestream Mach number, and injectant molecular weight. Mixing within this region of the flowfield is dominated by small-scale turbulence within the injectant plume. The transition of the dominant mixing mechanism, from vortex-driven mixing in the near field to small-scale turbulent mixing in the far field, was found to occur in the region about 10 diameters downstream of the injectors.

Hollo, Steven D.↗

Evaluation of OH laser-induced fluorescence techniques for supersonic combustion diagnostics

The limitations on application of dye laser and narrowband tunable KrF excimer laser systems to planar OH fluorescence measurements in supersonic combustion test facilities are examined. Included in the analysis are effects of collisional quenching, beam absorption, fluorescence trapping, and signal strengths on achievable measurement accuracy using several excitation and detection options for either of the two laser systems. Dye-based laser systems are found to be the method of choice for imaging OH concentrations less than 10 exp 15 per cu cm, while the KrF based systems provide significant reduction in measurement ambiguity for concentrations in excess of 10 exp 15 per cu cm.

Quagliaroli, T. M.↗