Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Performance Margins”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

The role of edge plasma parameters in H-mode density limit on the JET-ILW

A study of a dataset of JET H-mode plasma with the Be/W ITER-like wall (JET-ILW) shows that reaching the edge MHD ballooning limit leads to confinement degradation. However, unlike JET plasmas with a carbon wall (JET-C), the JET-ILW plasmas stay in a marginal dithering phase for a relatively long period, associated with a higher (≈20%) H-mode density limit (HDL) than JET-C equivalents. This suggests that ITER could be operated in H-mode with higher density than the scaling based on carbon wall devices, but likely with a dithering phase plasma with lower confinement. A new, reliable estimator for JET E r, min has been derived by combining HRTS measurements of pedestal gradient and edge-SOL decay lengths. JET radial E r ETB wells are observed in the range of -15 to -60 kV m -1 in high performance H-modes, consistent with previous CXRS results in ASDEX Upgrade. The results imply that a higher positive E × B shear in the near SOL plays a role in sustaining a marginal phase in JET-ILW which leads to a higher HDL than that in JET-C. The results of the JET-ILW dataset show agreement with the Goldston finite collisionality HD model for SOL broadening at high collisionality. A hypothesis for the dithering H-mode phase is proposed: as n e,SOL increases, ν *,SOL increases, SOL broadens, E r shear decreases, triggers L-mode; n e drops, ν *,SOL decreases, SOL becomes narrower, and E r shear increases, triggering H-mode, resulting in a cycle of H–L–H- oscillations. For burning plasma devices, such as ITER, operating just below the MHD limit for the dithering phase could be a promising regime for maximising core density, and fusion performance while minimising plasma-material interaction. The oscillatory signal during the dithering phase could be used as a precursor of undesirable plasma performance for control purposes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The effects of protease, xylanase, and xylo-oligosaccharides on growth performance, nutrient utilization, short-chain fatty acids, and microbiota in Eimeria -challenged broiler chickens fed low-protein diet

A total of 392 Cobb 500 off-sex male broiler chicks were used in a 21-day experiment to study the effect of protease, xylanase, and xylo-oligosaccharides (XOS) on improving growth performance, nutrient utilization (ileal digestibility and total tract retention), gene expression of nutrient transporters, cecal short-chain fatty acids (SCFAs), and microbiota profile of broilers challenged with Eimeria spp. Chicks at 0-day old were allocated to 8 treatments in a 4 × 2 factorial arrangement: 1) corn-soybean meal diet with no enzyme (Con); 2) Con plus 0.2 g/kg protease alone (PRO); 3) Con plus 0.2 g/kg protease combined with 0.1 g/kg xylanase (PRO + XYL); or 4) Con plus 0.5 g/kg xylo-oligosaccharides (XOS); with or without Eimeria challenge. The 4 diets were formulated to be marginally low in crude protein (183 g/kg). Challenged groups were inoculated with a solution containing E. maxima, E. acervulina, and E. tenella oocysts on d 15. Eimeria depressed (P < 0.01) growth performance and nutrient utilization. Supplemental protease improved (P < 0.05) body weight gain and feed intake in the prechallenge phase (d 0-15) but had no effect during the infection period (d 15-21). There was no interaction between infection and feed supplementation for nutrient utilization. The supplementations of either PRO or XOS alone increased (P < 0.01) total tract retention of Ca and tended (P < 0.1) to improve total tract retention of N, P, AME, and AMEn. Eimeria decreased (P < 0.05) expressions of GLUT2, GLUT5, PepT1, ATP2B1, CaSR, Calbidin D28K, NPT2, and ZnT1 but increased (P < 0.01) expression of GLUT1. XOS supplementation increased (P < 0.05) ATP2B1 expression. Protease decreased (P < 0.05) isobutyrate concentration in unchallenged treatments but not in challenged treatments. Eimeria decreased (P < 0.01) cecal saccharolytic SCFAs acetate and propionate but increased (P < 0.01) branched-chain fatty acid isovalerate. The supplementation of PRO + XYL or XOS increased (P < 0.05) cecal butyrate or decreased cecal isobutyrate concentrations, respectively. PRO + XYL and XOS decreased cecal protein levels in unchallenged birds but not challenged ones. Eimeria challenge significantly (P < 0.05) decreased the microbial richness (Observed features) and diversity (Shannon index and phylogenetic diversity) and changed the microbial composition by reducing the abundance of certain bacteria, such as Ruminococcus torques, and increasing the abundance of others, such as Anaerostipes. In contrast, none of the additives had any significant effect on the cecal microbial composition. In conclusion, PRO or XOS supplementation individually improved nutrient utilization. All the additives decreased the cecal content of branched-chain fatty acids, consistent with decreased cecal N concentration, although the effects were more pronounced in unchallenged birds. In addition, none of the feed additives impacted the Eimeria-induced microbial perturbation.

60 APPLIED LIFE SCIENCES↗

The effects of spatial and temporal resolution of gridded meteorological forcing on watershed hydrological responses

Abstract. Meteorological forcing plays a critical role in accurately simulating the watershed hydrological cycle. With the advancement of high-performance computing and the development of integrated watershed models, simulating the watershed hydrological cycle at high temporal (hourly to daily) and spatial resolution (tens of meters) has become efficient and computationally affordable. These hyperresolution watershed models require high resolution of meteorological forcing as model input to ensure the fidelity and accuracy of simulated responses. In this study, we utilized the Advanced Terrestrial Simulator (ATS), an integrated watershed model, to simulate surface and subsurface flow and land surface processes using unstructured meshes at the Coal Creek Watershed near Crested Butte (Colorado). We compared simulated watershed hydrologic responses including streamflow and distributed variables such as evapotranspiration, snow water equivalent (SWE), and groundwater table driven by three publicly available, gridded meteorological forcings (GMFs) – Daily Surface Weather and Climatological Summaries (Daymet), the Parameter-elevation Regressions on Independent Slopes Model (PRISM), and the North American Land Data Assimilation System (NLDAS). By comparing various spatial resolutions (ranging from 400 m to 4 km) of PRISM, the simulated streamflow only becomes marginally worse when spatial resolution of meteorological forcing is coarsened to 4 km (or 30 % of the watershed area). However, the 4 km-resolution has much worse performance than finer resolution in spatially distributed variables such as SWE. Using the temporally disaggregated PRISM, we compared models forced by different temporal resolutions (hourly to daily), and sub-daily resolution preserves the dynamic watershed responses (e.g., diurnal fluctuation of streamflow) that are absent in results forced by daily resolution. Conversely, the simulated streamflow shows better performance using daily resolution compared to that using sub-daily resolution. Our findings suggest that the choice of GMF and its spatiotemporal resolution depends on the quantity of interest and its spatial and temporal scale, which may have important implications for model calibration and watershed management decisions.

54 ENVIRONMENTAL SCIENCES↗

Time Dilated Bundt Cake Analysis of PV Output [Poster]

We present a novel method for modeling time-dependent statistics in the power signal generated by a photovoltaic (PV) system. Our white-box machine learning method is interpretable and auditable, based on principles of multiperiodic basis functions and convex optimization. Our proposed method of time dilating the daily signal to remove night time values results in a novel representation of PV power signals, evocative of a ‘Bundt cake’. The proposed model describes the marginal distribution of power output as a function of date and time. The resulting probabilistic model of a PV system can be used to perform a variety of tasks, and here, we demonstrate the application of clear sky detection.

14 SOLAR ENERGY↗

On the Feasibility of Market Manipulation and Energy Storage Arbitrage via Load-Altering Attacks

Around the globe, electric power networks are transforming into complex cyber–physical energy systems (CPES) due to the accelerating integration of both information and communication technologies (ICT) and distributed energy resources. While this integration improves power grid operations, the growing number of Internet-of-Things (IoT) controllers and high-wattage appliances being connected to the electric grid is creating new attack vectors, largely inherited from the IoT ecosystem, that could lead to disruptions and potentially energy market manipulation via coordinated load-altering attacks (LAAs). In this article, we explore the feasibility and effects of a realistic LAA targeted at IoT high-wattage loads connected at the distribution system level, designed to manipulate local energy markets and perform energy storage (ES) arbitrage. Realistic integrated transmission and distribution (T&D) systems are used to demonstrate the effects that LAAs have on locational marginal prices at the transmission level and in distribution systems adjacent to the targeted network.

25 ENERGY STORAGE↗

UPDATES FROM THE INVOLUTE WORKING GROUP

The HFIR, RHF, and FRM II reactors represent a particular class of Research and Test Reactors that provide some of the most intense and continuous neutron fluxes for science, industry, and medical applications. These high-performance reactors have achieved compact cores by operating with Highly Enriched Uranium fuel (HEU, 235U/U ≥ 20 wt. %) and utilizing fuel plates curved as an involute. Due to the proliferation risks, the international community aims to reduce or eliminate, when possible, the use of HEU fuel in civilian facilities by converting them to a Low-Enriched Uranium fuel (LEU, 235U/U < 20 wt. %). Conversion of these reactors without significantly compromising their performance or safety is a challenging endeavor that can tremendously benefit from advanced computational tools and thus, eliminate unnecessary conservatism to ensure sufficient thermal margins. Therefore, models are being developed using modern Computational Fluid Dynamics (CFD) and Computational Structural Mechanics (CSM) software to evaluate the steady-state safety margins of various LEU designs instead of being reliant on the more traditional, conservative methods. To gain the confidence and acceptance of high-fidelity modeling by the nuclear regulators, Argonne National Laboratory (ANL) and the involute reactors have formed an informal scientific group, the Involute Working Group (IWG). The IWG facilitates inter-organizational collaboration on experimental benchmarking, code-to-code comparisons, and Verification and Validation (V&V). This paper describes some of the recent IWG efforts in validating software against the existing experimental data, as well as code-to-code comparisons of different software used by the IWG members.

Bergeron, Aurelien↗

Economic viability of using thermal energy storage for flexible carbon capture on natural gas power plants

Fossil fuel-based power plants generate 80% of the electricity in the United States and provide a reliable generation source for both base and peak power demands. These plants are expected to adapt to changes in environmental policies that will require carbon management with carbon capture and storage (CCS) representing a possible solution. Current solvent-based CCS has a detrimental impact on a power plant's performance due to large heat loads required for carbon capture solvent regeneration. This parasitic load restricts the power plant's output and operation flexibility. Therefore, this study evaluates the feasibility of using thermal storage technologies for natural gas combined cycle (NGCC) power plants coupled with CCS to minimize the impact of solvent regeneration and enable the plant to operate at peak power output. Thermal storage can minimize the impact of CCS on the power plant by providing the heat load required for solvent regeneration during times of peak demand which will allow the plant to operate unrestricted and at full power. In total, fifteen unique thermal storage configurations were evaluated from three thermal storage categories: Brayton cycle heat pump, vapor compression heat pump, and heat recovery steam generator steam extraction for storage. The viability of these systems was determined by evaluating each configuration on thousands of real-world Locational Marginal Pricing (LMP) profiles from the New York Independent System Operator and California Independent System Operator electricity markets using a techno-economic analysis. Afterwards, results were compared to the performance of a base power plant (NGCC with CCS and no thermal storage) to determine the impact of thermal storage on power plant economics. Overall, six of the thermal storage configurations performed better than base CCS enabled power plant on between 11.5% and 38.7% of the LMP signals evaluated. The best performing configuration was a vapor compression heat pump that used flue gas as the working fluid and had both hot and cold thermal storage units. This configuration performed better than the base CCS power plant on 38.7% of the LMP profiles. The results of this study show thermal storage can mitigate the economic impact of carbon capture solvent regeneration on NGCC power plants. Discussion focuses on the impact of electricity pricing on the optimal thermal storage system, the advantages and disadvantages of the systems evaluated, and identifies limitations with the study.

25 ENERGY STORAGE↗

Assessment of MQXF Quench Heater Insulation Strength and Test of Modified Design

The HL-LHC interaction region magnet triplets (Q1,Q2, and Q3) will be composed of superconducting Nb 3 Sn quadrupoles. The MQXF quadrupole protection system is based on CLIQ (Coupling-Loss Induced Quench system) and outer layer quench heaters. Furthermore, this paper reports a summary of quench heaters to coil high voltage tests performed on MQXF short and long coils in air after fabrication, and in air and He gas after magnet training. Breakdown voltage values demonstrate good margin with respect to the Electrical design criteria for the HL-LHC inner triplet mag-nets. A modification in the quench heater installation-with an extra layer of fiber glass between the coil and the quench heater trace-has been proposed and tested in a mirror magnet to further increase electrical margins. Results demonstrated improvements of high voltage margin at the expense of a clear increase of hot spot temperature.The baseline heater to coil insulation was assessed to be able to guarantee safe operation for the Nb 3 Sn quadrupole magnets for the interaction regions of HL-LHC.

43 PARTICLE ACCELERATORS↗

Safety Analysis for the Versatile Test Reactor Conceptual Design

Safety analysis simulations have been carried out using the SAS4A/SASSYS-1 safety analysis code system to update the baseline set of results for the Versatile Test Reactor conceptual design. Results from a previous revision of this work provided input for the Conceptual Safety Design Report summarizing the overall safety basis for the VTR. This work will also support future analyses that will be required for Chapter 13, “Accident Analysis,” of a preliminary safety analysis report. A number of transients have been evaluated based on categories of postulated accident sequences suggested for consideration in NUREG-1537. Ultimately, the full spectrum of event initiators and subsequent accident sequences will be defined through a probabilistic risk assessment of the plant design following the implementation of the Licensing Modernization Project guidelines as described in the VTR Safety Design Strategy. Since that process is ongoing, the present analysis addresses several transients that are expected to be bounding accident scenarios that represent the three key ways to perturb a reactor: through changes to the core inlet temperature, mass flow rate, or reactivity. These correspond to a loss of heat sink (LOHS), loss of flow (LOF) or station blackout (SBO), and transient overpower (TOP), respectively. Both Protected and Unprotected versions of these transients have been evaluated, along with additional transients that include transient overpower with one stuck rod, pump coast-down failures, seismic events, and overcooling events. At the current stage of design, transient simulation results for the Versatile Test Reactor indicate that large safety margins exist for many event initiators. However, several “enabling” assumptions have been made, in terms of both design features and design limits, in order to perform the analyses; and these assumptions will need to be revised as the design matures. In addition, a larger spectrum of events needs to be evaluated as part of the on-going probabilistic risk assessment process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

How does drought affect residential water demand and price elasticity?

Urban water scarcity is an important social and economic concern, particularly as the intensity, duration, and frequency of droughts is increasing in many regions. We consider whether drought induces changes to water demand and the price elasticity of demand for water that may last beyond a drought’s official end date. If drought shocks prompt long-term changes in water demand behavior, and these changes occur at broad geographic scale, they could have important implications for modeling adaptive responses to water scarcity. We assemble a novel dataset on residential water demand and pricing in the western United States to test empirically for effects of drought on water demand and price elasticity. We perform our analysis with aggregate quantity, price, and drought data, accounting for endogenous prices under increasing-block water tariffs and using both average and marginal water fees in estimating water demand functions. Results are consistent with the hypothesis that households may become less price-sensitive after exposure to drought. However, we find no systematic evidence of long-run, drought-related reductions in water demand, itself.

demand hardening↗

Hybrid Heat Pump Controls: Conventional Dual Fuel versus Seamlessly Fuel Flexible Heat Pump

This paper compares the performance of a novel seamlessly fuel flexible heat pump (SFFHP) and conventional dual fuel heat pump (DFHP) for space heating. The conventional dual fuel systems either run on the gas furnace or electric heat pump at any given moment, as a comparison, the proposed seamlessly fuel flexible heat pump simultaneously consumes gas and electricity by continuously optimizing the proportion of each. The process air flows across the heat pump condenser first and then flows across the furnace coil, therefore, the heat pump temperature lift is reduced. SFFHP delivers energy savings by allowing each subsystem, i.e., gas furnace and electric heat pump, to operate where it performs best.For DFHP, two operation control strategies, i.e., non-restricted control and restricted control, are available on market. For the non-restricted mode, the thermostat has a switching temperature-programmed according to the balancing point of heating load and capacity curve. Heat pump operates above the switching temperature, while the furnace takes over under the switching temperature. For the restricted control, the compressor of a heat pump is disabled below a predefined lockout outdoor temperature to let the furnace take over. For SFFHP, a model predictive control strategy is developed to continuously adjust the capacities of the electric heat pump and gas furnace based on the foreseen weather data, utility price signals, and marginal grid emission signals with the goal of minimizing the utility cost and CO2 emission while guaranteeing comfort requirements.In this paper, DFHP and SFFHP are simulated using high-fidelity heat pump performance curves generated from DOE/ORNL heat pump design model. Performance comparison of DFHP and SFFHP during 2019-2020 heating season in Los Angeles shows that SFFHP with model predictive control achieves 23% utility cost reduction and 17 % CO2 emission reduction. Case studies demonstrate that SFFHP can deliver significant reductions in peak demand, utility cost, and CO2 emission. As a result, SFFHP can deliver superior benefits for utility cost reduction and CO2 emission reduction over conventional dual fuel heat pump.

Li, Zhenning↗

Developing occupant archetypes within urban low-income housing: A case study in Mumbai, India

Rapid urbanization pressure and poverty have created a push for affordable housing within the global south. The design of affordable housing can have consequences on the thermal (dis)comfort and behaviour of the occupants, hence requiring an occupant-centric approach to ensure sustainability. This paper investigates occupant behaviour within the urban poor households of Mumbai, India and its impact on their thermal comfort and energy use. This study is a first-of-its-kind attempt to explore the socio-demographic characteristics and energy-related behaviour of low-income occupants within Indian context. Three occupant archetypes, Indifferent Consumers; Considerate Savers; and Conscious Conventionals, were identified from the behavioural and psychographic characteristics gathered through a transverse field survey. A two-step clustering approach was adopted for occupant segmentation that highlighted considerable diversity in occupants’ adaptation measures, energy knowledge, energy habits, and their pro-environmental behaviour within similar socio-economic group. Building energy simulation of the representative archetype behaviour estimated up to 37% variations for air-conditioned and up to 8% variation for fan-assisted naturally ventilated housing units during peak summer months. The results from this study establish the significance of occupant factors in shaping energy demand and thermal comfort within low-income housing and pave way for developing occupant-centric building design strategies to serve this marginalized population. The developed low-income occupant archetypes would be useful for architects and energy modelers to generate realistic energy use profiles and improve building performance simulation results.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A scalable superconducting nanowire memory array with row–column addressing

Scalable superconducting memory is required for the development of low-energy superconducting computers and fault-tolerant quantum computers. Conventional superconducting logic-based memory cells possess a large footprint that limits scaling; nanowire-based superconducting memory cells, although more compact, have high error rates, which hinders integration into large arrays. Here we report a 4 × 4 superconducting nanowire memory array that is designed for scalable row–column operations and has a functional density of 2.6 Mbit cm −2 . Each memory cell is based on a nanowire loop consisting of two temperature-dependent superconducting switches and a variable kinetic inductor. The arrays operate at 1.3 K, where we implement and characterize multiflux quanta state storage and destructive read-out. By optimizing the write- and read-pulse sequences, we minimize bit errors and maximize operating margins. We achieve a minimum bit error rate of 10 −5 . Here, we also use circuit-level simulations to understand the memory cell’s dynamics, performance limits and stability under varying pulse amplitudes.

Electrical and electronic engineering↗

Concrete Structure Health Monitoring Using Vibro-acoustic Testing and Machine Learning

Assessment and management of aging concrete structures in nuclear power plants require a more systematic approach than simple reliance on margins of safety in existing codes. Research is required to deploy online monitoring capability to assess the health of concrete structures in nuclear power plants and perform predictive analytics based on heterogeneous measurements, in order to reduce the operation and maintenance costs. The research effort described in this report focuses on the health monitoring of concrete slabs containing reactive aggregates using the vibro-acoustic modulation (VAM) technique and predictive modeling. The research is developing an approach to enable detection, localization, and estimation of the extent of degradation in concrete slabs due to alkali-silica reaction (ASR). The project outcomes are generic and extendable to other degradation modes in concrete. A concrete slab without reinforcements was cast at Vanderbilt University and cured in aggressive conditions to accelerate ASR degradation. In this report, we develop a methodology for the automation of VAM testing, and the construction of machine learning models to facilitate damage localization in concrete structures. We investigate how machine learning models based on physics simulation data can be effectively utilized for damage localization (damage location and depth) and estimation in a concrete slab specimen. Our study indicates that these models could potentially support damage localization and estimation for NPP structures.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

ECAR-5633 AGR-5/6/7 Daily As-Run Thermal Analyses

The purpose of this engineering and calculations report is to document the results of the thermal analyses performed to calculate the Advanced Gas-Cooled Reactor (AGR)-5/6/7 as-run daily temperatures of the fuel compacts. Temperature data provided by this report will be used to evaluate fuel performance. The AGR-5/6 portion of the experiment was for fuel qualification at prototypic temperatures, while the AGR-7 portion of the experiment was a margin test at very high temperatures.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Geothermal Deep Direct Use for Turbine Inlet Cooling in East Texas

The National Renewable Energy Laboratory (NREL), the Southern Methodist University Geothermal Laboratory (SMU), Eastman Chemical (Longview, TX), and TAS (Houston, TX) evaluated the feasibility of using geothermal heat to improve the performance of a natural-gas power plant in East Texas. The area of interest is the Eastman Chemical plant in Longview, Texas, which is on the northwestern margin of a geologic region known as the Sabine Uplift. The feasibility study focused on determining the potential for accessing a subsurface hot-water geothermal resource within a 10-km radius of the site to provide thermal energy for absorption chillers. Wells within a 20-km radius are included for broader geological comparison to determine the heat flow, temperature-at-depth, field porosity and permeability. The lithologies of most interest are the Lower Cretaceous Trinity Group and Upper Jurassic Cotton Valley Group. The deeper Cotton Valley formations are hotter (averaging 117 to 130°C), yet permeability and porosity are low. The shallower Trinity Group contains more variability in permeability and porosity and lower temperatures averaging about 98 to 117°C. The shallower formations are considered despite the lower temperature because of increased ability to produce larger volumes of water and extract enough heat before reinjection. The complete SMU analysis is available in the National Geothermal Data System (NGDS). Tapping such deep geothermal sources for direct heating (as opposed to power generation) is known as geothermal deep direct use (DDU). Geothermal DDU has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for what are typically small-scale, variable-demand projects. This project examines the feasibility of geothermal energy integration in a natural-gas combined cycle power station in East Texas. The DDU resource is tapped to drive absorption chillers (24/7) for production of chilled water at 5-10°C (41-50°F). This chilled water is stored until needed, which allows for continuous operation with a relatively small-capacity geothermal/absorption chiller system. When conditions are favorable, the chilled water is dispatched to cool the air entering the compressor stage of a gas combustion turbine. This process, known as turbine inlet cooling (TIC), boosts power production during periods of high temperature and high-power demand. Such systems can enhance grid reliability and reduce the cost for peak-demand power. A simulation model of the power plant was developed in IPSEpro software and validated against operational data from the plant. This model allowed the team to estimate the additional power that could be produced by applying TIC under different operating and ambient conditions. Absorption chiller performance was estimated from vendor sources to determine the production rate of chilled water from the geothermal resource. Geothermal drilling and development costs were estimated using NREL's GEOPHIRES 2.0. The expected lower drilling costs in this region led to an estimated cost of geothermal heat of about $4/MMBtu (1.4 cents/kWh t ). The estimated cost for the absorption chillers and TIC hardware were obtained from literature sources and project partners. Hourly data were obtained for weather, natural gas and electricity prices, and plant operating state for 2017, which served as a representative year. NREL estimated the capital cost, operating cost, and additional electricity production and revenue for different combinations of geothermal capacity, chiller capacity, and water storage-tank size. The analysis drove toward smaller geothermal and chiller systems to reduce equipment cost. A relatively low-cost water storage tank accumulated the near-continuous chilled water output for later use when TIC was most valued.

15 GEOTHERMAL ENERGY↗

Reactor and fuel cycle performance of light water reactor fuel with 235 U enrichments above 5%

Recent advances in nuclear fuel materials research, particularly on the topic of accident-tolerant fuels, have brought up potential opportunities for expanding the operating envelope of existing light water reactors. As many of the performance improvements offered by these technologies may be most fully realized by increasing fuel enrichment beyond the standard 5% limit, this paper examines the potential reactor performance and fuel cycle performance of low-enriched uranium oxide fueled light water reactors by generically considering pressurized water reactors with 235 U enrichment from 5 to 7%. Advanced cladding, including accident-tolerant cladding, has the potential to increase fuel burnup limits related to hydrogen in the cladding that coincide with those limits associated with end-of-life reactivity. Therefore, higher enrichment will be necessary in order to realize the higher fuel burnups. This work includes evaluation of the fuel cycle length, discharge burnup, reactivity coefficients, and fuel cycle performance, including radioactive waste and environmental impact metrics per unit energy generated. The analysis was performed using the evaluation metrics from the US Department of Energy Office of Nuclear Energy Fuel Cycle Evaluation and Screening Study. The reactor performance and safety analysis show that enrichments between 5 and 7% would have similar fuel temperature and moderator temperature coefficients. However, the soluble boron coefficient would decrease in magnitude, requiring more corrosive boric acid in the coolant or other methods of reactivity control during the fuel cycle. At these higher enrichments the maximum burnup at the rim of the fuel pellet would increase by almost a factor of two, which is expected to impact the formation of high-burnup structure in the fuel and the corresponding thermo-mechanical fuel properties. The fuel cycle performance assessment shows that increasing enrichment reduces the quantity of high-level waste disposed per unit energy generated, but it increases the natural resource requirements normalized to a gigawatt-electricity-per-year basis. Another impact is the slightly higher discharge burnup, resulting in somewhat different activity levels of the spent nuclear fuel and high-level waste radioactivity at 100 and 100,000 years after fuel discharge. The environmental impacts—including land use, water use, carbon emission, and radiological exposure—are of the same magnitude per unit energy generated. Finally, however, the impacts are distributed differently. Less than 5% enrichment has marginally more impact on the back-end of the fuel cycle, and greater than 5% enrichment has marginally more impact on the front-end of the fuel cycle. Ultimately, no neutronic or reactor safety hindrances to employing light water reactor fuel with enrichments greater than 5% are identified; given the achievable reactor performance benefits with advanced fuels, further practical exploration of increased enrichment fuel is recommended.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Turbulent burning velocity of lean premixed hydrogen/air flames at engine conditions: Effects of turbulence intensity and length scale

For turbulent lean premixed hydrogen flames with strong thermodiffusively instabilities, most previous studies have focused on the influence of turbulence intensity, whereas the role of turbulence length scale is less well understood. Here, this study addresses this gap by conducting direct numerical simulations (DNS) of statistically planar turbulent premixed flames for a lean (ϕ=0.35) hydrogen/air mixture under independently varied turbulence intensity (u') and length scale (l T ) at engine-relevant thermodynamics conditions. Results show that as u' increases, the flame front becomes increasingly wrinkled, forming smaller cellular structures. In contrast, l T variations do not significantly alter the size of these structures. For the turbulent burning velocity (S T ), the normalized S T (i.e., S T /S L , where S L is the laminar flame speed) increases linearly with u', driven by both enhanced flame surface wrinkling (i.e., increased A T /A L ) and enhanced local burning rate (i.e., increased I 0 ). However, increasing l T reduces I 0 , despite a continued increase in A T /A L , resulting in only a marginal increase in S T /S L . To reveal the underlying mechanisms, especially the decreasing trend of I 0 with l T , local flame dynamics analyses are performed. It is found that as l T increases, the interaction between thermodiffusive effects and turbulence weakens due to the reduced tangential strain rate, while the flame curvature remains largely unchanged. This suppresses local reactivity enhancement and thus decreases I 0 , In contrast, an increase in u' enhances the interaction by amplifying both curvature fluctuation and tangential strain rate, leading to increased local reactivity (increased I 0 ). Finally, based on the DNS data, several new scaling models are proposed for the three global properties, S T /S L , A T /A L , and I 0 , and showed improvements compared to existing models. These findings provide new insights into the flame-turbulence interactions in thermodiffusively unstable hydrogen flames. The DNS dataset is also useful for the development of turbulent combustion models applicable to practical engine simulations.

Engine-relevant condition↗