Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Parallel processing (Electronic computers)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

222 records · Page 13

Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Evaluation of normalized metal artifact reduction (NMAR) in kVCT using MVCT prior images for radiotherapy treatment planning

Purpose: To evaluate the metal artifacts in kilovoltage computed tomography (kVCT) images that are corrected using a normalized metal artifact reduction (NMAR) method with megavoltage CT (MVCT) prior images.Methods: Tissue characterization phantoms containing bilateral steel inserts are used in all experiments. Two MVCT images, one without any metal artifact corrections and the other corrected using a modified iterative maximum likelihood polychromatic algorithm for CT (IMPACT) are translated to pseudo-kVCT images. These are then used as prior images without tissue classification in an NMAR technique for correcting the experimental kVCT image. The IMPACT method in MVCT included an additional model for the pair/triplet production process and the energy dependent response of the MVCT detectors. An experimental kVCT image, without the metal inserts and reconstructed using the filtered back projection (FBP) method, is artificially patched with the known steel inserts to get a reference image. The regular NMAR image containing the steel inserts that uses tissue classified kVCT prior and the NMAR images reconstructed using MVCT priors are compared with the reference image for metal artifact reduction. The Eclipse treatment planning system is used to calculate radiotherapy dose distributions on the corrected images and on the reference image using the Anisotropic Analytical Algorithm with 6 MV parallel opposed 5 × 10 cm{sup 2} fields passing through the bilateral steel inserts, and the results are compared. Gafchromic film is used to measure the actual dose delivered in a plane perpendicular to the beams at the isocenter.Results: The streaking and shading in the NMAR image using tissue classifications are significantly reduced. However, the structures, including metal, are deformed. Some uniform regions appear to have eroded from one side. There is a large variation of attenuation values inside the metal inserts. Similar results are seen in commercially corrected image. Use of MVCT prior images without tissue classification in NMAR significantly reduces these problems. The radiation dose calculated on the reference image is close to the dose measured using the film. Compared to the reference image, the calculated dose difference in the conventional NMAR image, the corrected images using uncorrected MVCT image, and IMPACT corrected MVCT image as priors is ∼15.5%, ∼5%, and ∼2.7%, respectively, at the isocenter.Conclusions: The deformation and erosion of the structures present in regular NMAR corrected images can be largely reduced by using MVCT priors without tissue segmentation. The attenuation value of metal being incorrect, large dose differences relative to the true value can result when using the conventional NMAR image. This difference can be significantly reduced if MVCT images are used as priors. Reduced tissue deformation, better tissue visualization, and correct information about the electron density of the tissues and metals in the artifact corrected images could help delineate the structures better, as well as calculate radiation dose more correctly, thus enhancing the quality of the radiotherapy treatment planning.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Evaluation of Low Power ARM Processors for Monte Carlo Particle Transport: MCNP6 on the ARM Cortex-A8 - Paper 83

In the push towards exascale computing, the limiting factors are power requirements and heat dissipation. Using current technology, the power required to drive an exascale supercomputer would near 400-MW. Clearly, future computing hardware will have to be more energy efficient in order to achieve exascale performance. Most of the current research in advanced computing architectures is in the use of standard CPUs with accelerators. However, these accelerators are not generally supported by the traditional scientific programming languages (C, C++, and Fortran) and the scientific software must be tailored specifically to take advantage of the accelerators. Large scale scientific software (hundreds-of-thousand to millions of lines of code) can not be easily ported to the computing platform du jour. The widespread use of low power ARM based processors in the mobile computing market offer a low power alternative to accelerators that are also supported by the traditional scientific programming languages and programming paradigms such as MPI and OpenMP. Computing architectures for scientific computing are often assessed using standard benchmarks such as LINPACK benchmark or using suites of mini-applications that are greatly simplified stand-ins for scientific software. Often the real applications that will deployed on the scientific supercomputers are not ported or tested until delivery of the machines. In order to evaluate the use of ARM processors for scientific computing the Monte Carlo particle transport code, MCNP version 6 was compiled on the ARM Cortex-A8 and a set of benchmark problems were used to assess performance in comparison to an Intel Xeon E5-2670 and the low power Intel Atom N270. MCNP is a continuous energy Monte Carlo particle transport code in development at Los Alamos National Laboratory since 1977. MCNP is used to transport neutrons, photon, electrons, and charged particles using continuous energy interaction data. It is commonly used in fields of nuclear power, nuclear medicine, radiation protection, and high-energy physics through-out the world. MCNP version 6 is approximately 450 thousand lines of code, written primary in Fortran90, with some C and C++. MCNP supports distributed multiprocessing using MPI and threading with OpenMP. The ARM Cortex-A8 executes MCNP6 using about twice as much power as the Intel Xeon E5-2670 and about the same amount of power as the Intel Atom N270. However, these results are encouraging for the use of low-power ARM chips in future supercomputers. The ARM Cortex-A8 is a 32-bit CPU and it's NEON general-purpose SIMD (single-instruction multiple data) engine does not support double-precision floating-point arithmetic. More recent ARM processors (ARM Cortex-A53 and Cortex-A57) support 64-bit addressing and have NEON co-processors that support double-precision floating-point arithmetic. ARM claims that the A50 series delivers a performance increase of 15 times the Cortex-A8 performance for similar power usage. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

TRIPOLI-4{sup R} version 9 Shielding for the Shielding Community: Overview, Relevant Benchmarking for Shielding and Licensing Policy - Paper 49

This is a review paper of the Shielding only version of TRIPOLI-4. TRIPOLI-4 and TRIPOLI-4 S: TRIPOLI{sup R} represents a family of radiation transport codes using the Monte Carlo method (1,2). It has been continuously developed at CEA since the mid 60's. TRIPOLI-4{sup R}, being the fourth generation, has been developed starting from the mid 90's in C++. It tracks neutrons from 20 MeV down to 10{sup -5} eV, photons, electrons and positrons from 100 MeV to 1 keV, in 3D arbitrary geometries either in TRIPOLI{sup R} proprietary format or ROOT(4) format. It reads its continuous energy nuclear data from any evaluation in ENDF format, including but not limited to JEFF-3.1.1 and ENDF/BVII.0. It has various simulation modes, fixed-source (with or without fission), criticality, or both of them chained. A variety of tallies are available: averaged flux in a volume (track length and collision estimators), surface flux and current, point flux, reaction rates, deposited energy, dpa, pka, gamma spectroscopy, mesh tallies, tallies for criticality (k{sub eff}, beta eff, kinetic parameters). It provides the user with embedded response functions from IRDF and EAF as well. Several variance reduction techniques (3), including automated ones, make it particularly suitable to deep penetration problems (implicit capture, Russian roulette, exponential biasing with automatic estimation of the importance map). It may run in parallel, on single multi-core machines as well as heterogeneous networks of stations or massively parallel machines. It comes with productivity tools designed to speed-up the elaboration and verification of the input deck as well as the output analysis: 2D interactive display of geometry; 2D display of mesh tallies and collision sites; 3D input deck modeler; compatibility with ROOT tools to post-process TRIPOLI{sup R} outputs. Its V and V test base is made of more than 1000 internationally accepted benchmarks from ICSBEP and SINBAD (REPLICA, ASPIS, NESDIP) and covers all its application domains, including several shielding cases which will be detailed in the talk. TRIPOLI-4{sup R} is the reference Monte Carlo code for CEA, EDF, and also for AREVA for a number of applications. A 'Shielding-only' version has been designed to specifically answer the needs of the shielding community. It is distributed through the NEA Databank with a license for R and D, covering the fusion applications, whose terms are detailed in the paper.

61 RADIATION PROTECTION AND DOSIMETRY↗

Mechanisms of interfacial reactivity in near surface and extreme environments

The local water structure surrounding ions in aqueous solutions greatly affects their chemical properties such as reaction rates, ion association, and proton and electron transport. These properties result in the behavior of ions in natural aqueous environments. For example ore transport is facilitated by chloride ion pair formation and the reaction of ions in an interface is strongly dependent on the dehydration of the ion hydration shell. We are developing the use of high-­resolution XAFS observations and 1st principles based MD-­XAFS analysis (spectra simulated using 1st principle methods with no adjustable parameters, AIMD) to interpret the solution properties of strongly interacting aqueous solutes under arbitrary pressure and temperature conditions. In the 1st principle MD-­XAFS method density functional theory (DFT) based MD simulations(Car and Parrinello, 1985) are used to generate a large ensemble of structural snap shots of the hydration region. These are then used to generate scattering intensities. I emphasize three points about this novel approach to analyzing XAFS data. 1st: As illustrated in Figure 1, the level of agreement between the calculated and observed intensities is considerably higher than has been obtained by any XAFS analysis to date (note 2nd shell region, R> 2 Å). 2nd: This result was obtained from a parameter free simulation with no fitting of the interaction potentials to any data. This supports the use of these methods for more difficult environments and more complex solutes (polyions). 3rd: New information about the shell structure (Figure 1) is now available because of this more detailed agreement. We note also that both multiple scattering and second shell features are well represented in the analysis. As far as we know this is the 1st analysis of second shell structure and multiple scattering. Excellent agreement has been obtained for most of the third row metal ions: Ca 2+ , Zn 2+ , Cu 2+ , Ni 2+ , Co 2+ , Mn 2+ , Fe 3+ , Cr 3+ . Calculations on these systems are demanding because of their open electronic shells, and high ionic charge. Principal Investigator: Professor John Weare (University of California, San Diego) The prediction of the interactions of geochemical fluids with minerals, nanoparticles, and colloids under extreme near surface conditions of temperature (T) and pressure (P) is a grand challenge research need in geosciences (U.S. DOE 2007, Basic Research Needs for Geosciences: Facilitating the 21st Energy Systems.). To evaluate the impact of these processes on energy production and management strategies it is necessary to have a high level of understanding of the interaction between complex natural fluids and mineral formations. This program emphasizes 1st principle parameter free simulations of complex chemical processes in solutions, in the mineral phase, and in the interfaces between these phases The development of new computational tools (with emphasis on oxide materials and reaction dynamics) tailored to treat wide range of conditions and time scales experienced in such geochemical applications is has been developed. Because of the sensitivity of the interaction in these systems to electronic structure and local bonding environments, and of the need to describe bond breaking/formation, our simulations are based on interactions calculated at the electronic structure level (ab-initio molecular dynamics, AIMD). The progress in the computational aspects of program may be summarized in terms of the following themes (objectives); Development of efficient parameter free dynamical simulation technology based on 1st principles force and energy calculations especially adapted for geochemical applications (e.g., mineral, interfaces and aqueous solutions) (continuing program); Calculation of the dynamics of water structure of in the surface-water interface of transition metal oxides and oxihydroxides; and Development of improved (beyond DFT+GGA) electronic structure calculations for minerals and the interface region that more accurately calculate electron correlation, spin density, and localization. The focus of the program is also on the iron oxide and oxihydroxide minerals and Fe 2+ (aq)/Fe 3+ (cr) oxidation in the mineral solution interface region. These methods included the development of model Hamilitonian methods that can be solved to near convergence for single site models (DMFT) and many-body perturbation methods (MP2, GW); Development of time decomposition methods to extend time scales of molecular dynamics (MD) simulations and support the use of high complexity electronic structure calculations (MP2, CCSD(T)) of forces for use in dynamical simulations where very high chemical accuracy is required (microsolvated reactions in absorbed surface layers); and The development of a new linear scaling finite element solver for eigenvalue problem that supports solution of quantum problems with unusual potential and boundary values. Application progress of the above new simulation technology to problems of geochemical interests includes; The prediction of metal oxide surface structure and the reduction/oxidation of Fe 3+ (cr)/Fe 2+ (aq) in metal oxide (hematite, goethite)/solution interfaces. Result: water interacts strongly with the 001 Hematite surface; interaction of water with the 100 goethite is weak; The study of ion solvation and the composition of ion hydration shells under extreme conditions (focus on Fe 3+/2+ , Al 3+ and Mg 2+ and their hydroxide speciation). Result: Ion association in water solutions can be calculated from 1st principle methods. Efficient sampling of the free energy requires more development; The continued development of new high resolution analysis of XAFS scattering of disordered systems (particularly Al, Mg) and of XANES calculations for aqueous ions. Result: EXAFS spectra can be calculated to high accuracy with DFT level dynamic simulations; The exploration of electron localization and electron transport in metal oxides (highly correlated materials). Result: Proper description of electron localization requires levels of calculation beyond DFT; and Localization of electrons in DFT type Hamiltonians was studied. Result: For very Dirac high exchange new solutions (New unphysical bifrucations) to the eigenvalue problem are found. The program was highly collaborative involving faculty and students in mathematics, physics and computer science departments as well as coworkers at the Pacific Northwest National Laboratories (PNNL). The students in this program had the opportunity to develop skills in the development of methods, the implementation of method on high performance parallel computers and the application of these methods to problem in geochemical science. Much of the software that was developed was incorporated in the NWchem software package maintained by PNNL.

58 GEOSCIENCES↗

Stereo Imaging Velocimetry of Mixing Driven by Buoyancy Induced Flow Fields

Mixing of two fluids generated by steady and particularly g-jitter acceleration is fundamental towards the understanding of transport phenomena in a microgravity environment. We propose to carry out flight and ground-based experiments to quantify flow fields due to g-jitter type of accelerations using Stereo Imaging Velocimetry (SIV), and measure the concentration field using laser fluorescence. The understanding of the effects of g-jitter on transport phenomena is of great practical interest to the microgravity community and impacts the design of experiments for the Space Shuttle as well as the International Space Station. The aim of our proposed research is to provide quantitative data to the community on the effects of g-jitter on flow fields due to mixing induced by buoyancy forces. The fundamental phenomenon of mixing occurs in a broad range of materials processing encompassing the growth of opto-electronic materials and semiconductors, (by directional freezing and physical vapor transport), to solution and protein crystal growth. In materials processing of these systems, crystal homogeneity, which is affected by the solutal field distribution, is one of the major issues. The understanding of fluid mixing driven by buoyancy forces, besides its importance as a topic in fundamental science, can contribute towards the understanding of how solutal fields behave under various body forces. The body forces of interest are steady acceleration and g-jitter acceleration as in a Space Shuttle environment or the International Space Station. Since control of the body force is important, the flight experiment will be carried out on a tunable microgravity vibration isolation mount, which will permit us to precisely input the desired forcing function to simulate a range of body forces. To that end, we propose to design a flight experiment that can only be carried out under microgravity conditions to fully exploit the effects of various body forces on fluid mixing. Recent flight experiments, by the P.I. through collaboration with the Canadian Space Agency (STS-85, August 1997), aimed at determining the stability of the interface between two miscible liquids inside an enclosure show that a long liquid column (5 cm) under microgravity isolation conditions can be stable, i.e. the interface remains sharp and vertical over a short time scale; thus transport occurs by molecular mass diffusion. On the other hand, when the two liquids were excited from a controlled vibration source (Microgravity Vibration Isolation Mount) two to four mode large amplitude quasi-stationary waves were observed. The data was limited to CCD recording of the dynamics of the interface between the two fluids. We propose to carry out flight experiments to quantify the dynamics of the flow field using Stereo Imaging Velocimetry and measure the concentration field using laser fluorescence. The results will serve as a basis to understand effects of g-jitter on transport phenomena, in this case mass diffusion. As the measurement of the kinematics of the flow field will shed light on the instability mechanism. The research will allow measurement of the flow field in microgravity environment to prove two hypotheses: (1) Maxwell's hypothesis: finite convection always exists in diffusing systems, and (2) Quasi-stationary waves inside a bounded enclosure in a microgravity environment is generated by Kelvin-Helmholtz instability; resonance of the interface which produces incipient mixing is due to Rayleigh-Taylor instability. The first hypothesis can be used as a benchmark experiment to illustrate diffusive mixing. The second hypothesis will lead to the understanding of g-jitter effects on buoyancy driven flow fields which occur in many situations involving materials processing, and other basic fluid physics phenomena. In addition, the second hypothesis will also provide insight in how Rayleigh-Taylor and Kelvin-Helmholtz instabilities propagate concentration fronts during mixing. Measurement of the flow field using SIV is important because it is the flow field which causes instability at the interface between the two fluids. Mixing driven by buoyancy induced flow fields will be addressed both experimentally and computationally. The experimental effort will address the kinematics of mixing: stretching, transport and chaos. Quantification of the mechanisms of mixing will consists of measuring the flow field using the SIV system at Glenn and capturing the dynamics of the interface, to measure mass transport, using a CCD camera. These experiments will be carried out within the framework of Earth's gravity and g-jitter microgravity acceleration as in a Space Shuttle environment or the International Space Station. The g-jitter will be induced and controlled using a tunable vibration isolation platform to isolate against vibration as well as input periodic and random vibration to the system. The parametric range of the microgravity experiment will be extended from the experiments on STS-85 to investigate higher mode quasi-stationary waves (8 to 12), as well as resonance regions which leads to chaos and turbulence. Ground-based experiments will focus on effects of vibration on stably stratified fluid layers in order to scale for possible scenarios in a microgravity environment. These vibrations will be subjected perpendicular to the concentration field on the ground since the parallel case can only be carried out in a microgravity environment. The concept of dynamical similarity will be applied to tune the experiments as closely as possible to a Space Shuttle environment or the International Space Station. The computational effort will take advantage of the Computational Laboratory at Glenn to corroborate the experimental findings with predictions of the dynamics of the flow field using the codes FLUENT (finite difference based) and FIDAP (finite element based). We will investigate two important cases, single-fluid model to address dilute systems with negligible jump in viscosity and the more general two-fluid model which accounts for finite jump in viscosity. Apart from its microgravity relevance, this experiment is well suited to study dynamics in nonlinear systems.

Duval, W. M. B.↗