Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PV performance”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Effect of training on blood volume and plasma hormone concentrations in the elderly

The purpose of this investigation was to determine the effects of 6 months of endurance training on resting plasma (PV) and blood volume (BV), and resting hormone and electrolyte concentrations in the elderly. Thirty-eight elderly men and women (ages 60-82 yr) were assigned to endurance exercise training (N = 29) or to control (N = 9) groups. Resting plasma levels of adrenocorticotropic hormone, vasopressin, aldosterone, norepinephrine, epinephrine, sodium, potassium, and protein were measured at the start (T1) and end (T2) of 26 wk of training. PV measurement was performed using the Evan's blue dye technique. Endurance training consisted of uphill treadmill walking or stairclimbing exercise 3 times.wk-1, 30-45 min.d-1, at 75-84% of maximal heart rate reserve. The exercise group increased VO2max by 11.2% (P < or = 0.05) and increased resting PV and BV by 11.2% and 12.7% (P < or = 0.05), respectively. Hormone and electrolyte levels in the exercise group remained unchanged; all variables were unchanged in the control group. These results are similar to findings in younger individuals. Because plasma hormone concentrations were maintained despite a chronically elevated BV, endurance training in healthy, elderly subjects may be associated with a resetting of volume receptors.

Clinical Trial↗

LCOE reduction through proactively optimized monitoring of PV Systems (Final Technical Report)

The project demonstrates the value proposition for a high-resolution monitoring system (HRMS) with diagnostic-prognostic capability and determine its impact on LCOE. The HRMS differs from conventional monitoring systems in a number of ways. First it will include the capability to automatically measure IV curves at the string and module levels. This provides a much richer view into the DC performance of the PV system and allows classification of many typical failure and degradation modes. Second, it will incorporate software capable of quantifying power and energy losses in the field as well as define the location and mechanism of the power and energy loss. Moreover, we aimed to deliver a prognostic system that is capable of predicting certain failures before they occur and giving system operators the opportunity to more efficiently plan operations and maintenance (O&M) activity in order to lower costs and increase yield over the life of the system. The research identifies cost targets required for different monitoring stages, including at the string combiner, at the individual string, and at the module level, to lower the levelized cost of energy (LCOE). Finally, a comprehensive guide determines the value PV monitoring brings to PV field operations. The guide assists plant operators in maximizing value from existing plants and identify the trade-offs of different monitoring solutions for future plants depending on the size, location, and expected system lifetime.

14 SOLAR ENERGY↗

Performance Evaluation of an Advanced Distributed Energy Resource Management Algorithm

This paper presents performance evaluation of a new distributed energy resource management system (DERMS) algorithm via an advanced hardware-in-the-loop (HIL) platform. The HIL platform provides realistic testing in a laboratory environment, including the accurate modeling of sub-transmission and distribution networks, the DERMS software controller, and 84 power hardware solar photovoltaic (PV) inverters, standard communication protocols, and a capacitor bank controller. The DERMS algorithm is also called, Grid-Optimization of Solar (GO-Solar) platform which includes predictive state estimation (PSE) and online multiple objective optimization (OMOO) to dispatch the legacy devices and distributed energy resources (e.g., PV). The voltage regulation performance is evaluated under three scenarios, volt-var smart inverter (baseline), and DERMS control for 100% and 30% of PV. The results show that controlling 30% of PV systems with the GO-Solar platform may provide the best balance of control performance and implementation cost.

distributed energy resource management system (DER↗

Use of non-contact voltmeter to quantify potential induced degradation in CdTe modules

Potential induced degradation (PID) is a significant reliability issue for photovoltaic modules in the field. Conventionally, to detect the PID-affected modules, all the modules in a string are individually disconnected and measured using I-V (current–voltage) tracers. It is extremely time-consuming, expensive and unsafe (if the module connectors are field aged) approach. In our approach, we aim detecting the PID-affected modules quickly, inexpensively and safely without disconnecting individual modules in the string. In this study, contactless electrostatic voltmeter’s (ESV) strength was explored to detect the PID-affected cadmium telluride (CdTe) modules in a string. These contactless measurements on high-voltage PV strings could make this technique unique and preferable to detect PID-affected modules in a string compared to the I-V curve method. In this work, a CdTe module was stressed for PID using the Aluminum (Al) foil method in a walk-in environmental chamber, which resulted in a reduction of module's peak current (I max ), peak voltage (Vmax), and fill factor (FF), and hence power (Pmax). Outdoor light I-V, EL, and ESV measurements were performed pre- and post-PID to determine the effectiveness of the non-contact ESV technique. Further, the ESV technique successfully detected the change in V max , and hence Pmax, compared to the pre-and post-PID conditions. A difference of less than 2% was observed in the results of the non-contact and non-interruptive method compared to the conventionally used interruptive voltmeter or I-V tracer method. This technique and the test results demonstrate a significant promise to identify poor-performing modules in PV string without disconnection of individual modules in the string.

14 SOLAR ENERGY↗

Structure and Electronic Properties of Mesopores in Si PV Devices with PLEO Contacts

All current state-of-the-art silicon photovoltaic (PV) devices employ some flavor of passivating contact structure to minimize detrimental recombination while providing good conductivity. These properties are most often provided by a dielectric layer (SiNx, Al2O3, or SiOx) that is in contact with the crystalline silicon (c-Si) substrate. The effectiveness of these layers is heavily dependent on the nanoscale structure of both the dielectric layers and the crystalline silicon interface. As an example, the tunneling probability for charge carriers across thin SiOx layers, a process that is critical to maintain high conductivity, is extremely sensitive to the SiOx thickness. SiOx with a thickness below 2 nm readily allows charge carrier tunneling, whereas it is impeded for greater thicknesses. In the latter case it has been shown that modifications to the thermal processing schedule can induce disruptions, or pinholes, in thick SiOx layers that allow transport of charge carriers while maintaining excellent passivation. However, this requires higher temperatures processes that may inhibit widespread adoption by industry. Recently, another option has been presented that may circumvent the necessity for high temperature processing, namely metal assisted chemical etching (MACE). MACE relies on deposition of Ag nanoparticles onto the SiOx layers with subsequent electroless etching to form mesopores in the SiOx layers that are analogous to the pinholes created with high temperature processing. The size and density can be controlled based on the Ag nanoparticle deposition conditions. The resulting contact structure is known as polysilicon on locally etched oxide (PLEO) contacts. The nanoscale structure of the mesopores in PLEO contacts define the device level observables such as recombination current (Jo) and junction resistance. In this work we present atomic resolution transmission electron microscopy (TEM) analysis of mesopores in PLEO contacts formed with a different processing conditions to connect provide insight into how the nanoscale structure of the SiOx layer influences PV device properties. Additionally, we have previously used electron beam induced current (EBIC) to probe local transport properties in Si PV devices with a SiOx layer containing pinholes due to high temperature processing. Using EBIC we were able to directly show the enhance charge carrier transport through the pinholes. Here we also employ EBIC to study non-uniformities in charge carrier recombination and transport associated with mesopores in PLEO contacts and compare these results with our previous work on devices with pinholes in the SiOx formed through high temperature processes. The products of this work provide critical information that is required to both further optimize performance of Si PV devices with PLEO contact and to drive future adoption of this technology by industry.

ENGINEERING,SOLAR ENERGY↗

PV CAMPER Annual Report 30 December 2020

The objective of the Photovoltaic Collaborative to Advance Multi-climate and Performance Research (PVCAMPER) is to: 1) Build and maintain a multi-climate research platform to enable pioneering photovoltaic research; 2) Validate the performance of emerging technologies in specific climates; 3) Help accelerate the world’s transition to a solar-intensive economy. Our focus in achieving those goals is to foster collaborative research and to build an international organization dedicated to improving data quality, minimizing measurement uncertainty and exchanging best practices related to PV performance.

14 SOLAR ENERGY↗

A TCN-Based Hybrid Forecasting Framework for Hours-Ahead Utility-Scale PV Forecasting

This paper presents a Temporal Convolutional Network (TCN) based hybrid PV forecasting framework for enhancing hours-ahead utility-scale PV forecasting. The hybrid framework consists of two forecasting models: a physics-based trend forecasting (TF) model and a data-driven fluctuation forecasting (FF) model. Three TCNs are integrated in the framework for: i) blending the inputs from different Numerical Weather Prediction sources for the TF model to achieve superior performance on forecasting hourly PV profiles, ii) capturing spatial-temporal correlations between detector sites and the target site in the FF model to achieve more accurate forecast of intra- hour PV power drops, and iii) reconciling TF and FF results to obtain coherent hours-ahead PV forecast with both hourly trends and intra-hour fluctuations well preserved. To automatically identify the most contributive neighboring sites for forming a detector network, a scenario-based correlation analysis method is developed, which significantly improves the capability of the FF model on capturing large power fluctuations caused by cloud movements. Here, the framework is developed, tested, and validated using actual PV data collected from 95 PV farms in North Carolina. Simulation results show that the performance of 6 hours ahead PV power forecasting is improved by 20% - 30% compared with state-of-the-art methods.

42 ENGINEERING↗

Optical Durability of Contemporary PV Encapsulants Through Artificial UV Weathering

Modern c-Si photovoltaic (PV) cells provide high performance but can be vulnerable to ultraviolet light induced degradation (UV-ID). Encapsulants, if chosen correctly, can mitigate UV-ID of the PV cell. Here, we explore performance and durability of 14 commercial encapsulant materials before, during, and after irradiation with UV-containing light. Materials include contemporary, polymer-based encapsulants with a base polymer of poly (ethylene co-vinyl acetate) (EVA), polyethylene-..alpha..-olefin (POE), or their composite (EPE). Polymers contain additives that induce UV-blocking, UV-transmitting, or UV-downshifting properties. We use test coupons to study degradation in a chamber held at 65 degrees C under a xenon light source for up to 4000 h of exposure, corresponding to a cumulative dose of 11.5 MJ/m2 at 340 nm. We examine optical properties including spectral transmittance, yellowness index and spectral fluorescence, considering changes to both the encapsulant and glass as a function of weathering time. Degradation modes identified include discoloration, changes to UV cutoff wavelength, changes to solar-weighted transmittance, and most notably a change to the UV-managing properties of some additives. We propose the use of solar-weighted transmittance in the 300- to 400-nm range to better track performance changes in the UV region associated with the UV-related additive. This is especially relevant for the emerging class of UV-downshifting additives, as metrics like UV-cutoff can understate the degree of degradation or change in these materials. While most encapsulants show very little change after weathering, some show significant changes that directly impact how much UV light would reach an underlying cell.

14 SOLAR ENERGY↗

Updates to the Instant Online PV LCOE Calculator Tool

Levelized cost of energy (LCOE) is an important metric for techno-economic analysis of PV modules, systems, and performance. An NREL team within DuraMAT has developed a simplified PV-specific LCOE calculator as an alternative to the NREL System Advisor Model (SAM) for applications that do not have the degree of detail required by SAM. This webinar will review recent data and new features that have been added to the simplified calculator this year, including breakeven buttons, commercial system options, and inverter loading ratios. It will also review the structure of the source code on GitHub, how to edit a local version of the calculator, and walk through some example use cases for the calculator.

calculator↗

Passivated Interfaces and Surface Recombination Velocities in Halide Perovskites

Surfaces and charge-extracting contacts remain major sources of non-radiative recombination loss; limiting the performance of perovskite PV compared to theoretical limits. We investigate mixed-cation mixed-halide perovskites and demonstrate that, with chemical surface passivation, they can achieve >4 μs minority carrier lifetimes, and >20% external PL quantum yields (PLQY), and nearly single-exponential decay kinetics. This high PLQY observed corresponds to ~97% of the Shockley-Queisser theoretical quasi-fermi level splitting, a first for MA-free mixed-cation mixed-halide compositions. The high PLQY and long PL lifetimes allow us to measure average surface recombination velocities (SRV) <10cm/s, with a champion low of ~1cm/s (a conservative estimate). We show how such improvements in SRV should lead to an absolute improvement in PCE of >4% even with the best of contact alignments. We investigate different MA-free high bandgap compositions, including bandgaps relevant for tandem applications (1.7-1.8eV), and demonstrate performance improvements across all these compositions with our surface passivation strategy. Lastly, using a combination of surface characterization techniques, we show Lewis base interactions of the passivating agent with the perovskite surfaces.

14 SOLAR ENERGY↗

Passivated Interfaces and Surface Recombination Velocities in Halide Perovskites

Surfaces and charge-extracting contacts remain major sources of non-radiative recombination loss; limiting the performance of perovskite PV compared to theoretical limits. We investigate mixed-cation mixed-halide perovskites and demonstrate that, with chemical surface passivation, they can achieve >4 μs minority carrier lifetimes, and >20% external PL quantum yields (PLQY), and nearly single-exponential decay kinetics. This high PLQY observed corresponds to ~97% of the Shockley-Queisser theoretical quasi-fermi level splitting, a first for MA-free mixed-cation mixed-halide compositions. The high PLQY and long PL lifetimes allow us to measure average surface recombination velocities (SRV) <10cm/s, with a champion low of ~1cm/s (a conservative estimate). We show how such improvements in SRV should lead to an absolute improvement in PCE of >4% even with the best of contact alignments. We investigate different MA-free high bandgap compositions, including bandgaps relevant for tandem applications (1.7-1.8eV), and demonstrate performance improvements across all these compositions with our surface passivation strategy. Lastly, using a combination of surface characterization techniques, we show Lewis base interactions of the passivating agent with the perovskite surfaces.

passivation↗

R&D to Ensure a Scientific Basis for Qualification Tests and Standards (Final Report)

Project return on investment in a photovoltaic (PV) system depends increasingly on maintaining high energy yields, and the system lifetime is a major factor in levelized cost of electricity (LCOE). Thus, the rate of PV deployment and the success of these assets depends upon reliable long-term power generation. The overarching objective of this program is to improve photovoltaic (PV) module reliability via development of tests and standards. Where reliability problems or risk are discovered, we can design tests to ensure that these liabilities don't affect future generations of products. Customers can use these tests to understand which products are susceptible to certain degradation mechanisms, and manufacturers can use the tests to design unwanted characteristics out of their products. The work under this program identifies PV reliability needs, performs characterization that provides scientific understanding of targeted degradation mechanisms, and translates those data into practical and predictive test protocols and standards. Major accomplishments include: A model for polarization-type potential induced degradation (PID-p) was developed and validated against experimental data. NREL is currently leading a new edition of IEC 62804-1 for PID detection. PID-p can cause large losses in current and voltage for some module designs on cloudy days. Finite element modeling (FEM) and experiment was used to determine when cells crack in a module. It was shown that cells in landscape orientation are much more likely to crack than those on portrait orientation. Shortly thereafter, the first products with portrait-oriented cells were introduced. Studies of how to test for light and elevated temperature degradation (LeTID) culminated with the publication of IEC TS 63342. Software to predict the progression of LeTID was developed, validated, and made publicly available. Field validated tests and international standards for durability of PV module coatings abrasion, backsheets, and encapsulants were developed. Examples are IEC 62788-1-1, IEC 62788-2 ED2, IEC TS 62788-7-2, IEC 62788-7-3 ED1, IEC 63209-2. NREL led the development a high-temperature testing technical specification, and published guidelines that enable installers to determine whether higher-temperature testing is needed, simply based on location and mounting configuration. In a number of our case studies, variations in the bills of materials or workmanship have been associated with variations in reliability. These observations emphasize the importance of quality assurance to reliability. A framework for criticality (i.e. Pareto) analysis was developed and published. The framework helps us and other researchers determine what problems should be addressed for reliability research to have the biggest industry impact. NREL continues to participate actively in international standards development and stakeholder engagement activities, including organizing an annual PV Reliability Workshop. These activities are important for ensuring we address issues that are relevant and timely, and that we convey our results to those who may benefit.

14 SOLAR ENERGY↗

Mosaic Infrared Sensor for Space Astronomy (MIRSSA)

The development of mosaic infrared detector/focal plane arrays for space astronomy is reported. The Mosaic IR Sensor for Space Astronomy (MIRSSA) Program is an effort to develop PV HgCdTe detector arrays with the spectral response of up to 5 micron and silicon CCDs for low temperature applications. Desired background-limited performance (BLIP) for space applications requires an extremely high R sub A product which can be achieved by selecting the detector materials and the operating temperature. The parameters were determined by measurement of HgCdTe PV detector arrays at various temperatures in the SW and MW spectral bands. It is demonstrated that high performance PV HgCdTe detectors can be fabricated for low temperature applications.

Source record↗

Quantum computing approach for building surface sunlit in urban-scale energy modeling

Solar shadow calculations are needed in building energy modeling and performance simulation of PV systems installed on roofs or facades of buildings. We present a quantum computing approach for calculation of building surface sunlit fractions by recasting solar visibility as a binary optimization problem solved by quantum annealing. Each triangulated surface centroid is encoded as a binary qubit indicating sunlit or shaded status. Geometric visibility constraints are derived from the Möller-Trumbore intersection algorithm and converted into a constrained quadratic binary model compatible with contemporary quantum annealers. The coefficients were embedded to D-Wave quantum computer. To demonstrate feasibility, we conducted a case study in San Francisco for a target building with 52 triangles and roughly 2700 nearby triangles within 50 m evaluated at representative winter and summer solar positions. The results demonstrated that quantum annealing can reliably calculate and distinguish sunlit from shaded surfaces. Quantum samples achieved average accuracy exceeding 92.4 %, with the aggregate surface-level agreement approaching 99.9 %. The outputs of quantum computers agreed closely with classical algorithms, indicating practical feasibility and promising scalability. Finally, the hourly sunlit fractions of building surfaces can be obtained for urban energy modelling. This is the first study to apply quantum computing to the solar shadow and building surface sunlit calculation. It introduces a new paradigm that differs fundamentally from traditional approaches.

Deng, Zhipeng↗

District-Scale Analysis of Electricity Load and Strategies to Improve Energy Reliability Using Prototype District Models

Projected increases in electricity demand in the U.S. highlight the urgent need for effective load management to ensure grid reliability. As the building sector accounts for approximately 75% of electricity usage, enhancing energy efficiency and flexibility in this sector is crucial. Adopting district-level approaches offers significant advantages over traditional individual building analyses by enabling shared infrastructure and economies of scale. To navigate the data and computational challenges associated with modeling energy at the district level, prototype district models have been proposed as holistic, system-level solutions that capture complex interactions within typical configurations. This study presents these models as a reference tool for analyzing district-scale energy systems across various climate zones in the U.S. Developed with input from stakeholders, these models integrate varied building characteristics, inter-building connections, and energy system interactions. A case study utilizing the Urban Edge prototype district model, implemented on the URBANopt™ platform, evaluates multiple demand scenarios and the impact of distributed energy resources such as fuel-fired backup generators, photovoltaic systems, and batteries. Findings suggest that while new electric systems can significantly reduce annual energy use, they may also elevate peak electricity loads, with a notable 43% increase in heating-dominant climate zone 5B. The optimal backup power solutions vary based on location, influenced by factors such as utility rates and incentives. For example, PV and batteries perform well in high-cost regions like New York City, while diesel backup generators are more suitable for backup needs in climate zone 3A, such as Atlanta. Thus, this research highlights the importance of prototype district models for future district-scale energy planning.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Characterization of front contact degradation in monocrystalline and multicrystalline silicon photovoltaic modules following damp heat exposure

Reliability and durability tests play a key role in the photovoltaic (PV) industry by minimizing potential failure risks for both existing and new cell and module technologies. In this work, a detailed study of contact degradation in monocrystalline and multicrystalline PV modules is performed. The modules are subjected to a sequence of damp heat (DH) exposures followed by electrical characterization after each step. Electroluminescence (EL) imaging shows different darkening patterns for monocrystalline modules compared to multicrystalline modules; the former shows darkening near the busbars and the latter shows it across virtually the entire cell surface. The primary loss mechanism is confirmed to be resistive after comparing the current-voltage (I–V) characteristics at each DH exposure step. Representative samples have been cored out from both the degraded modules and controls for materials characterization to gain further insights into the degradation mechanism. Top-down and cross-sectional scanning electron microscopy (SEM), energy dispersive spectroscopy (EDS), and top-down high-resolution X-ray photoelectron spectroscopy (XPS) analysis performed on the cored samples confirm the degradation is due to metallization corrosion. Our study suggests that the difference in the darkening pattern can most likely be attributed to the different silver paste composition used for contacting each cell technology, particularly the composition of the glass frit.

36 MATERIALS SCIENCE↗

Validation of Subhourly Clipping Loss Error Corrections

Under-performance of solar PV systems is an important issue that increases risks for stakeholders, including developers, investors and operators. Recently some attention has focused on underestimation of inverter clipping losses as a possible source of over-prediction where sub-hourly solar variability is high. Several models and data sets have been analyzed over the past few years, with the aim of quantifying, predicting, and correcting underestimated clipping loss errors for systems with high DC/AC ratio and solar variability. In this research, we apply a machine learning model developed at NREL to two physical PV systems, to correct for subhourly clipping losses. For each system, we compare overall AC power output for the model taken at 1-minute intervals to AC power output taken at 1-hour intervals with the addition of the subhourly clipping correction. Our findings consistently show that the addition of the clipping loss correction lead to a reduction in mean bias error of 0.8% and 1.2% for systems A and B, respectively, with no additional filtering applied. When examining high solar variability periods where clipping is more pronounced, system A and B experienced a 1.8% and 2.7% reduction in mean bias error, respectively, when the clipping correction was applied.

machine learning↗

Secondary Frequency Regulation from Variable Generation through Uncertainty Decomposition: An Economic and Reliability Perspective

The rapid integration of variable generation (VG), such as photovoltaics (PV), necessitates an increase in the secondary frequency regulation (SFR) to handle the system intra-dispatch interval imbalance because of VG's variation. Although PV has the control capability to provide SFR, the main challenge is in guaranteeing the delivery of PV's energy and SFRs capacities in the automatic generation control (AGC) within each dispatch interval considering its uncertainty. This paper proposes a deliverable VG SFR provision model with endogenous VG's power uncertainty decomposition. First, the uncertainty of VG is decomposed using distributionally robust chance constraints through which the deliverable SFR provision is guaranteed. Next, the intra-interval frequency response of PV's SFR is validated with a user defined AGC model including the PV power plant. Finally, the economic benefits and the reliability improvements such as the frequency deviation reduction with PV providing SFRcan be integrated and evaluated. The proposed model is tested in a modified 18-bus system and in the Western Electricity Coordinating Council test system. Results demonstrate that with the deliverable SFR from PV, the system cost and the frequency reliability can be improved simultaneously. PV's SFR performance can be guaranteed with the proposed model.

14 SOLAR ENERGY↗