Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PUMPS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Four-Pass Coupler for Laser-Diode-Pumped Solid-State Laser

A four-pass optical coupler affords increased (in comparison with related prior two-pass optical couplers) utilization of light generated by a laser diode in side pumping of a solid-state laser slab. The original application for which this coupler was conceived involves a neodymium-doped yttrium aluminum garnet (Nd:YAG) crystal slab, which, when pumped by a row of laser diodes at a wavelength of 809 nm, lases at a wavelength of 1,064 nm. Heretofore, typically, a thin laser slab has been pumped in two passes, the second pass occurring by virtue of reflection of pump light from a highly reflective thin film on the side opposite the side through which the pump light enters. In two-pass pumping, a Nd:YAG slab having a thickness of 2 mm (which is typical) absorbs about 84 percent of the 809-nm pump light power, leaving about 16 percent of the pump light power to travel back toward the laser diodes. This unused power can cause localized heating of the laser diodes, thereby reducing their lifetimes. Moreover, if the slab is thinner than 2 mm, then even more unused power travels back toward the laser diodes. The four-pass optical coupler captures most of this unused pump light and sends it back to the laser slab for two more passes. As a result, the slab absorbs more pump light, as though it were twice as thick. The gain and laser cavity beam quality of a smaller laser slab in conjunction with this optical coupler can thus be made comparable to those of a larger two-pass-pumped laser slab.

Coyle, Donald B.↗

Miniature Scroll Pumps Fabricated by LIGA

Miniature scroll pumps have been proposed as roughing pumps (low - vacuum pumps) for miniature scientific instruments (e.g., portable mass spectrometers and gas analyzers) that depend on vacuum. The larger scroll pumps used as roughing pumps in some older vacuum systems are fabricated by conventional machining. Typically, such an older scroll pump includes (1) an electric motor with an eccentric shaft to generate orbital motion of a scroll and (2) conventional bearings to restrict the orbital motion to a circle. The proposed miniature scroll pumps would differ from the prior, larger ones in both design and fabrication. A miniature scroll pump would include two scrolls: one mounted on a stationary baseplate and one on a flexure stage (see figure). An electromagnetic actuator in the form of two pairs of voice coils in a push-pull configuration would make the flexure stage move in the desired circular orbit. The capacitance between the scrolls would be monitored to provide position (gap) feedback to a control system that would adjust the drive signals applied to the voice coils to maintain the circular orbit as needed for precise sealing of the scrolls. To minimize power consumption and maximize precision of control, the flexure stage would be driven at the frequency of its mechanical resonance. The miniaturization of these pumps would entail both operational and manufacturing tolerances of <1 m. Such tight tolerances cannot be achieved easily by conventional machining of high-aspect-ratio structures like those of scroll-pump components. In addition, the vibrations of conventional motors and ball bearings exceed these tight tolerances by an order of magnitude. Therefore, the proposed pumps would be fabricated by the microfabrication method known by the German acronym LIGA ( lithographie, galvanoformung, abformung, which means lithography, electroforming, molding) because LIGA has been shown to be capable of providing the required tolerances at large aspect ratios.

Wiberg, Dean↗

A hybrid method to evaluate the life cycle climate performance of heat pumps

Heat pumps have a significant impact on the climate, and numerous studies exist discussing the environmental impact of heat pumps quantitatively. Life Cycle Climate Performance (LCCP) is a widely accepted metric and can evaluate the carbon footprint of heat pumps from cradle to grave. LCCP calculation typically requires inputs like annual energy consumption, the material used, refrigerant type, and charge level, which are usually the intermediate or final results from heat pump simulation tools. Thus, a platform linking the heat pump simulation software, local weather conditions, and LCCP evaluation tool can simplify the heat pump design process, especially for complicated systems. This paper presents an LCCP evaluation tool accessing the outputs from the DOE Heat Pump Design Model and the building loads and temperature bin data from AHRI standard 210/240. As for case studies, this paper investigates the LCCP values and life cycle electricity costs (LCEC) of a given cooling-based heat pump with R410A in five typical US cities. In conclusion, this cooling-based heat pump has the highest LCCP value at Chicago and lowest LCCP value at Seattle. In contrast, the heat pump has the highest LCEC at Seattle and the lowest LCEC at Miami. As a future work, a more comprehensive carbon emission and cost analysis of heat pump systems will be conducted through all major cities around the world.

Shen, Bo↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗

Optimizations of spin-exchange relaxation-free magnetometer based on potassium and rubidium hybrid optical pumping

The hybrid optical pumping atomic magnetometers have not realized its theoretical sensitivity, the optimization is critical for optimal performance. The optimizations proposed in this paper are suitable for hybrid optical pumping atomic magnetometer, which contains two alkali species. To optimize the parameters, the dynamic equations of spin evolution with two alkali species were solved, whose steady-state solution is used to optimize the parameters. The demand of the power of the pump beam is large for hybrid optical pumping. Moreover, the sensitivity of the hybrid optical pumping magnetometer increases with the increase of the power density of the pump beam. The density ratio between the two alkali species is especially important for hybrid optical pumping magnetometer. A simple expression for optimizing the density ratio is proposed in this paper, which can help to determine the mole faction of the alkali atoms in fabricating the hybrid cell before the cell is sealed. The spin-exchange rate between the two alkali species is proportional to the saturated density of the alkali vapor, which is highly dependent on the temperature of the cell. Consequently, the sensitivity of the hybrid optical pumping magnetometer is dependent on the temperature of the cell. We proposed the thermal optimization of the hybrid cell for a hybrid optical pumping magnetometer, which can improve the sensitivity especially when the power of the pump beam is low. With these optimizations, a sensitivity of approximately 5 fT/Hz{sup 1/2} is achieved with gradiometer arrangement.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Concentrating Solar Power - Molten Salt Pump Development, Final Technical Report (Phase 1)

The purpose of this project is to develop a long shafted pump to operate at high temperatures for the purpose of producing energy with renewable resources. In Phase I of this three phase project we developed molten salt pump requirements, evaluated existing hardware designs for necessary modifications, developed a preliminary design of the pump concept, and developed refined cost estimates for Phase II and Phase III of the project. The decision has been made not to continue the project into Phases II and III. There is an ever increasing world-wide demand for sources of energy. With only a limited supply of fossil fuels, and with the costs to obtain and produce those fuels increasing, sources of renewable energy must be found. Currently, capturing the sun's energy is expensive compared to heritage fossil fuel energy production. However, there are government requirements on Industry to increase the amount of energy generated from renewable resources. The objective of this project is to design, build and test a long-shafted, molten salt pump. This is the type of pump necessary for a molten salt thermal storage system in a commercial-scale solar trough plant. This project is under the Department of Energy (DOE) Solar Energy Technologies Program, managed by the Office of Energy Efficiency and Renewable Energy. To reduce the levelized cost of energy (LCOE), and to meet the requirements of 'tomorrows' demand, technical innovations are needed. The DOE is committed to reducing the LCOE to 7-10 cents/kWh by 2015, and to 5-7 cents/kWh by 2020. To accomplish these goals, the performance envelope for commercial use of long-shafted molten salt pumps must be expanded. The intent of this project is to verify acceptable operation of pump components in the type of molten salt (thermal storage medium) used in commercial power plants today. Field testing will be necessary to verify the integrity of the pump design, and thus reduce the risk to industry. While the primary goal is to design a pump for a trough solar power plant system, the intent is for the design to be extensible to a solar power tower application. This can be accomplished by adding pumping stages to increase the discharge pressure to the levels necessary for a solar power tower application. This report incorporates all available conceptual design information completed for this project in Phase I.

14 SOLAR ENERGY↗

Seismic Testing of Glovebox Feedthrough Connectors and Vacuum Pumps

In the design of tritium processing systems, the glovebox stripper system processes the glovebox atmosphere to recover tritium released inside the glovebox confinement. The glovebox stripper system must also be capable of processing the additional in-leakage caused by a Design Basis Accident (DBA) earthquake, in order to maintain the glovebox pressure negative relative to the room. However, it is unknown how much additional leakage occurs from electrical bulkhead feedthrough connectors after a DBA event. As there are dozens of these connectors on a tritium glovebox system, the potential increase in in-leakage can be significant. One vital part of the glovebox stripper system are the vacuum pumps that maintain the negative atmosphere of the glovebox following a DBA earthquake. The pumps must be able to operate following an earthquake. One candidate pump is the Senior Aerospace MB-602 Metal Bellows (Met-Bel) pump. A second alternative is the hermetically sealed Edwards Vacuum nXDS15iC Scroll Pump. The Edwards scroll pump is potentially a less expensive alternative to the Met-Bel pumps, but it is unknown if this scroll pumps will survive a DBA accident and remain operational. In order to determine the electrical feedthrough in-leakage and the candidate pumps’ survivability, a seismic test was performed to simulate a DBA earthquake. This report summarizes the results of seismic test, including helium leak rates and functionality tests for the electrical feedthroughs and vacuum pumps. All components had pre- and post-test leak rates less than the threshold valve of 1x10 -6 scc per sec.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

F-AREA PUMP TANK 1 MIXING ANALYSIS

The F-area pump tanks are used to transfer supernate, sludge, and other materials. In any transfer, the solution must stay well mixed without allowing particulate matter to settle out of the liquid and, thus, accumulate in the bottom of the pump tank. Recently, the pulse jet mixing in F-area Pump Tank 1 (FPT1) has been decommissioned. An analysis of the liquid transfer through FPT1 has been performed using computational fluid dynamics (CFD) methods to assess whether or not the velocities throughout the tank will remain high enough to keep all particulate suspended using only transfer and recirculation pumps. The following paragraph is an abbreviated synopsis of the transfer procedure for FPT1 [1, 2]. Prior to a transfer, FPT1 begins to be filled with inhibited water through the inlet transfer line (TI). When the tank liquid level reaches 52.5 inches above the absolute tank bottom, the recirculation pump (RI and RO) is activated. At a tank liquid level of 72.5 inches above the absolute tank bottom, the outlet transfer line (TO) is activated to reduce the liquid level in FPT1 and transfer inhibited water to H-area Pump Tank 7 (HPT7). The liquid level is reduced down to 39.5 inches, with an allowable range from 37.5 to 41.5 inches above the absolute tank bottom. HPT7 goes through a similar procedure as FPT1 until both have tank liquid levels of approximately 39.5 inches above the absolute tank bottom. The transfer of inhibited water continues until a steady-state has been reached in both pump tanks. At this point, the supernate/sludge transfer begins with a minimum flow rate of 70 gpm and an average flow rate of 150 gpm. After the transfer is complete, the pump tanks (both FPT1 and HPT7) are pumped down to between 20.5 and 22.5 inches (above absolute bottom) and then flushed with 25,000 gallons of inhibited water to remove any possible sludge heal. After the flushing, the pump tanks are emptied. Note that the tank liquid level is measured using diptubes. Figure 2.1 provides a simplified sketch (not to scale) of FPT1 during the steady-state transfer condition, which consists of two inlet flows that impact the liquid surface as plunging jets and two outlet flows drawn from near the bottom of the tank. During the transfer, the supernate level is held at 39.5 inches above the absolute bottom of the tank [1, 2]. In addition, the FPT1 can contain up to 16.7 wt.% sludge particles within the supernate for a given transfer [2]. Test results from Tank 40 sludge Batch 3 [3] provide a typical range of particulate diameters between 0.1 and 25 {micro}m, with approximately 20 vol.% of the sludge distribution consisting of particles less than 1 {micro}m in diameter. The purpose of this analysis is to estimate FPT1 flow field during the steady-state transfer conditions to ensure that the tank remains mixed and that the velocities throughout the tank are sufficient to keep all sludge particulate suspended.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Development and Qualification of Advancements in Submersible Transfer Pump Performance and Life, and Implications for Advancing and Supporting Processing Options - 13343

From the 1950's through the 1990's, relatively inexpensive, 'off-the-shelf' type, vertical turbine pumps (VTP) were used to transfer Hanford waste. The technology of those pumps was rooted primarily in the mining and agricultural (irrigation) industries. HNF-3218, Double Shell Tank (DST) Transfer Pump History and Reliability Report, 1998, provides a summary of Hanford DST pump history to that date. Such pumps operated in the Hanford radioactive waste environment for an average of only 400 hours before failure. However, at that time, operating life was not a driving criteria within the Department of Energy (DOE) complex, as the failure of transfer pumps represented a relatively low replacement and disposal cost. The Environmental Protection Agency (EPA) issuance of the 'Debris Rule' in 1992, which mandated that mixed radioactive waste contaminated equipment be decontaminated to a 'low level waste' category prior to burial, elevated the significance of transfer pump reliability and decontamination capability as life-cycle cost criteria. Minimizing the frequency of transfer pump failures and design for decontamination became significantly important and served to drive the need toward specific, designed for application pumps to meet this challenge. To this end, Washington River Protection Solutions (WRPS) and the supplier, Curtiss-Wright EMD (EMD), have recently collaborated on an intense program to further transfer pump technology and performance. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Defining an industrial heat pump: A review & synthesis

Clear and understandable definitions of advanced energy technologies are not common and often confuse those who are not experts. This review paper addresses a critical issue in the field of heat pumps: the ambiguity surrounding the term “industrial heat pump.” The term, as discussed in various literature and media, often leads to misconceptions about the capabilities and applications of heat pumps, particularly in industrial contexts. This review paper seeks to refine and unify the definition of industrial heat pumps by analyzing existing academic and commercial literature, industry reports, and classifications. Unique identifiers explored for the definition of an industrial heat pump include the use of waste heat, operating temperature ranges, size specifications, and specific end-use applications. The study reveals differences in how industrial heat pumps are defined in academic and commercial contexts, highlighting the need for a standardized definition to facilitate better communication among manufacturers, policymakers, and end users. This is especially important considering recent legislative efforts such as the HEAT Act, which seeks to promote industrial heat pump adoption. The proposed definition aims to provide clarity while supporting the effective deployment of industrial heat pumps. With proper adoption, the definition will help promote the role of industrial heat pumps in achieving energy efficiency goals in the industrial sector. The intended impact is for the definition to serve as a foundational reference for future research and policy development.

Heat pump characteristics↗

Two-color, intracavity pump–probe, cavity ringdown spectroscopy

Here, we report a proof-of-principle demonstration of intracavity pump–probe, cavity ringdown (CRD) detection in a three-mirror, traveling-wave cavity. With cavity-enhanced pump power and probe absorption path length, the technique is a generally applicable, high-sensitivity, high-selectivity detection method. In our experiments, the pump radiation is switched off during every other probe ringdown, which allows uncorrelated measurements of analyte and background cavity decay rates. The net, two-color signal from the difference between the pump-on and pump-off decay rates is immune to empty-CRD drifts and spectral overlaps from non-target molecular transitions. The immunity to the ringdown drifts allows longer signal-averaging and, thus, higher detection sensitivity. The ability to compensate for the background absorption enhances the detection selectivity in spectrally congested regions. Our technique is well-suited for trace-detection in the mid-IR region, where pump–probe schemes based on strong rovibrational transitions can be applied. In this work, two-color CRD detection is implemented on a ladder-type, three-level system based on the N 2 O, ν 3 = 1 ← 0, P(19) (pump) and ν 3 = 2 ← 1, R(18) (probe), rovibrational transitions. By frequency-locking two-quantum cascade lasers to the p-polarization (pump, Finesse = 5280) and s-polarization (probe, Finesse = 67 700) cavity modes, we achieve high intracavity pump power (36 W) and high probe ringdown rates (>2 kHz). The observed two-color spectra are simulated by a density-matrix, three-level system model that is solved under the constraints of the cavity resonance conditions. In addition to its background compensation capability, experimental flexibility in the selection of pump–probe schemes and signal insensitivity to intracavity laser power are further features that enhance the utility of our technique for mid-IR trace-detection.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Testing of a Continuous Cryopump for Primary Fusion Device Pumping and Direct Internal Recycling

Here, the concept of directly recirculating fusion machine exhaust gas, bypassing the tritium plant, to make fuel pellets was proposed in the 1990s and later termed direct internal recycling (DIR). In the DIR concept, the residual fusion fuel in the machine exhaust stream is separated from impurities locally and diverted directly to the fueling systems, bypassing isotopic separation and other processing equipment, and therefore significantly reducing the required size of the fuel processing plant, reducing plant inventory, and thus increasing the economic viability of fusion as an energy source. One concept for DIR consists of a series of cryogenic pumps to separate the impurities from the machine exhaust gas using different triple point temperatures and saturation curves of exhaust constituents. In this concept, the plasma exhaust is initially passed through an impurity trap operating at ~25–30 K to desublimate impurities such as hydrocarbons, argon, oxygen, and nitrogen. The resulting process stream will consist of DT fuel and helium. The process stream is then pumped by a continuous cryopump known as a “snail pump.” This pump is a steady-state continuous cryopump that desublimates all remaining exhaust gas constituents while allowing helium, a byproduct of the fusion reaction, to pass through. The helium is pumped to the tritium plant for processing while the desublimated material is continuously scraped off, heated up, and transported to the fueling system. This article will present the cryogenic DIR concept and outline the design and operation of the snail pump, along with results from preliminary testing. Tests to assess pumping and separation efficiency found that at D2 flows below 50.7 Pa ⋅ m3/s with 1% helium, the pump is capable of pumping and separating the gas with a resulting DIR fraction of >99%, with no helium entrained in the primary fuel exhaust stream. The main limitation is due to the thermal performance of the cryogenic circuits of the pump, which will be addressed in future testing.

Gebhart III, Trey E. [Oak Ridge National Laborator↗

Specificity and tunability of efflux pumps: A new role for the proton gradient?

Efflux pumps that transport antibacterial drugs out of bacterial cells have broad specificity, commonly leading to broad spectrum resistance and limiting treatment strategies for infections. It remains unclear how efflux pumps can maintain this broad spectrum specificity to diverse drug molecules while limiting the efflux of other cytoplasmic content. We have investigated the origins of this broad specificity using theoretical models informed by the experimentally determined structural and kinetic properties of efflux pumps. We developed a set of mathematical models describing operation of efflux pumps as a discrete cyclic stochastic process across a network of states characterizing pump conformations and the presence/absence of bound ligands and protons. These include a minimal three-state model that lends itself to clear analytic calculations as well as a five-state model that relaxes some of the simpler model’s most strict assumptions. We found that the pump specificity is determined not solely by the drug affinity to the pump–as is commonly assumed–but it is also directly affected by the periplasmic pH and the transmembrane potential. Therefore, changes to the proton concentration gradient and voltage drop across the membrane can influence how effective the pump is at extruding a particular drug molecule. Furthermore, we found that while both the proton concentration gradient across the membrane and the transmembrane potential contribute to the thermodynamic force driving the pump, their effects on the efflux enter not strictly in a combined proton motive force. Rather, they have two distinguishable effects on the overall throughput. These results highlight the unexpected effects of thermodynamic driving forces out of equilibrium and illustrate how efflux pump structure and function are conducive to the emergence of multidrug resistance.

59 BASIC BIOLOGICAL SCIENCES↗

Direct solar-pumped iodine laser amplifier

This semiannual progress report covers the period from September 1, 1988 to February 28, 1989 under NASA grant NAG-1-441 entitled, Direct Solar-Pumped Iodine Laser Amplifier. During this period, the research effort was concentrated on the solar pumped master oscillator power amplifier (MOPA) system using n-C3F7I. In the experimental work, the amplification measurement was conducted to identify the optimum conditions for amplification of the center's Vortek solar simulator pumped iodine laser amplifier. A modeling effort was also pursued to explain the experimental results in the theoretical work. The amplification measurement of the solar simulator pumped iodine laser amplifier is the first amplification experiment on the continuously pumped amplifier. The small signal amplification of 5 was achieved for the triple pass geometry of the 15 cm long solar simulator pumped amplifier at the n-C3F7I pressure of 20 torr, at the flow velocity of 6 m/sec and at the pumping intensity of 1500 solar constants. The XeCl laser pumped iodine laser oscillator, which was developed in the previous research, was employed as the master oscillator for the amplification measurement. In the theoretical work, the rate equations of the amplifier was established and the small signal amplification was calculated for the solar simulator pumped iodine laser amplifier. The amplification calculated from the kinetic equations with the previously measured rate coefficients reveals very large disagreement with experimental measurement. Moreover, the optimum condition predicted by the kinetic equation is quite discrepant with that measured by experiment. This fact indicates the necessity of study in the measurement of rate coefficients of the continuously pumped iodine laser system.

Han, Kwang S.↗

Improving the Performance of Two-Stage Gas Guns By Adding a Diaphragm in the Pump Tube

Herein, we study the technique of improving the gun performance by installing a diaphragm in the pump tube of the gun. A CFD study is carried out for the 0.28 in. gun in the Hypervelocity Free Flight Radiation (HFF RAD) range at the NASA Ames Research Center. The normal, full-length pump tube is studied as well as two pump tubes of reduced length (approximately 75% and approximately 33% of the normal length). Significant improvements in performance are calculated to be gained for the reduced length pump tubes upon the addition of the diaphragm. These improvements are identified as reductions in maximum pressures in the pump tube and at the projectile base of approximately 20%, while maintaining the projectile muzzle velocity or as increases in muzzle velocity of approximately 0.5 km/sec while not increasing the maximum pressures in the gun. Also, it is found that both guns with reduced pump tube length (with diaphragms) could maintain the performance of gun with the full length pump tube without diaphragms, whereas the guns with reduced pump tube lengths without diaphragms could not. A five-shot experimental investigation of the pump tube diaphragm technique is carried out for the gun with a pump tube length of 75% normal. The CFD predictions of increased muzzle velocity are borne out by the experimental data. Modest, but useful muzzle velocity increases (2.5 - 6%) are obtained upon the installation of a diaphragm, compared to a benchmark shot without a diaphragm.

Bogdanoff, D. W.↗

Water Flow Performance of a Superscale Model of the Fastrac Liquid Oxygen Pump

As part of the National Aeronautics and Space Administration's ongoing effort to lower the cost of access to space, the Marshall Space Flight Center has developed a rocket engine with 60,000 pounds of thrust for use on the Reusable Launch Vehicle technology demonstrator slated for launch in 2000. This gas generator cycle engine, known as the Fastrac engine, uses liquid oxygen and RP-1 for propellants and includes single stage liquid oxygen and RP-1 pumps and a single stage supersonic turbine on a common shaft. The turbopump design effort included the first use and application of new suction capability prediction codes and three-dimensional blade generation codes in an attempt to reduce the turbomachinery design and certification costs typically associated with rocket engine development. To verify the pump's predicted cavitation performance, a water flow test of a superscale model of the Fastrac liquid oxygen pump was conducted to experimentally evaluate the liquid oxygen pump's performance at and around the design point. The water flow test article replicated the flow path of the Fastrac liquid oxygen pump in a 1.582x scale model, including scaled seal clearances for correct leakage flow at a model operating speed of 5000 revolutions per minute. Flow entered the 3-blade axial-flow inducer, transitioned to a shrouded, 6-blade radial impeller, and discharged into a vaneless radial diffuser and collection volute. The test article included approximately 50 total and static pressure measurement locations as well as flush-mounted, high frequency pressure transducers for complete mapping of the pressure environment. The primary objectives of the water flow test were to measure the steady-state and dynamic pressure environment of the liquid oxygen pump versus flow coefficient, suction specific speed, and back face leakage flow rate. Results showed excellent correlation between the predicted and experimentally measured pump head rise at low suction specific speeds. Likewise, only small circumferential variations in steady-state impeller exit and radial diffuser pressure distributions were observed from 80% to 120% of the design flow coefficient, matching the computational predictions and confirming that the integrated design approach has minimized any exit volute-induced distortions. The test article exhibited suction performance trends typically observed in inducer designs with virtually constant head rise with decreasing inlet pressure until complete pump head breakdown. Unfortunately, the net positive suction head at 3% head fall-off occurred far below that predicted at all tested flow coefficients, resulting in a negative net positive suction head margin at the design point in water. Additional testing to map the unsteady pressure environment was conducted and interesting rotating phenomena at the inducer inlet were observed. These rotating phenomena's cell numbers, direction, and speed were correlated with pump operating parameters. The impact of the unsteady phenomena and their corresponding energy losses on the unexpectedly poor pump performance is also discussed.

Skelley, Stephen↗

Mean Line Pump Flow Model in Rocket Engine System Simulation

A mean line pump flow modeling method has been developed to provide a fast capability for modeling turbopumps of rocket engines. Based on this method, a mean line pump flow code PUMPA has been written that can predict the performance of pumps at off-design operating conditions, given the loss of the diffusion system at the design point. The pump code can model axial flow inducers, mixed-flow and centrifugal pumps. The code can model multistage pumps in series. The code features rapid input setup and computer run time, and is an effective analysis and conceptual design tool. The map generation capability of the code provides the map information needed for interfacing with a rocket engine system modeling code. The off-design and multistage modeling capabilities of the code permit parametric design space exploration of candidate pump configurations and provide pump performance data for engine system evaluation. The PUMPA code has been integrated with the Numerical Propulsion System Simulation (NPSS) code and an expander rocket engine system has been simulated. The mean line pump flow code runs as an integral part of the NPSS rocket engine system simulation and provides key pump performance information directly to the system model at all operating conditions.

Veres, Joseph P.↗

Water Flow Performance of a Superscale Model of the Fastrac Liquid Oxygen Pump

As part of the National Aeronautics and Space Administration's ongoing effort to lower the cost of access to space, the Marshall Space Flight Center has developed a rocket engine with 60,000 pounds of thrust for use on the Reusable Launch Vehicle technology demonstrator slated for launch in 2000. This gas generator cycle engine, known as the Fastrac engine, uses liquid oxygen and RP-1 for propellants and includes single stage liquid oxygen and RP-1 pumps and a single stage supersonic turbine on a common shaft. The turbopump design effort included the first use and application of new suction capability prediction codes and three-dimensional blade generation codes in an attempt to reduce the turbomachinery design and certification costs typically associated with rocket engine development. To verify the pump's predicted cavitation performance, a water flow test of a superscale model of the Fastrac liquid oxygen pump was conducted to experimentally evaluate the liquid oxygen pump's performance at and around the design point. The water flow test article replicated the flow path of the Fastrac liquid oxygen pump in a 1.582x scale model, including scaled seal clearances for correct leakage flow at a model operating speed of 5000 revolutions per minute. Flow entered the 3-blade axial-flow inducer, transitioned to a shrouded, 6- blade radial impeller, and discharged into a vaneless radial diffuser and collection volute. The test article included approximately 50 total and static pressure measurement locations as well as flush-mounted, high frequency pressure transducers for complete mapping of the pressure environment. The primary objectives of the water flow test were to measure the steady-state and dynamic pressure environment of the liquid oxygen pump versus flow coefficient, suction specific speed, and back face leakage flow rate. Initial results showed acceptable correlation between the predicted and experimentally measured pump head rise at low suction specific speeds. Likewise, only small circumferential variations in steady-state were observed from 80% to 120% of the design flow coefficient, matching the computational predictions and confirming that the integrated design approach has minimized any exit volute-induced distortions. The test article exhibited suction performance trends typically observed in inducer designs with virtually constant head rise with decreasing inlet pressure until complete pump head breakdown. Unfortunately, the net positive suction head at 3% head fall-off occurred far below that predicted at all tested flow coefficients, resulting in a negative net positive suction head margin at the design point in water. Additional testing to map the unsteady pressure environment was conducted and cavitation-induced flow disturbances at the inducer inlet were observed. Two distinct disturbances were identified, one rotating and one stationary relative to the fixed frame of reference, while the transition from one regime to the next produced significant effects on the steady state pump performance. The impact of the unsteady phenomena and the corresponding energy losses on the unexpectedly poor pump performance is also discussed.

Skelley, Stephen↗