Nonlinear pulsations of unstable massive main- sequence stars. I - Small-amplitude tests of an approximation technique
Unstable massive main sequence stars nonlinear pulsation, using small amplitude tests of approximation technique
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Unstable massive main sequence stars nonlinear pulsation, using small amplitude tests of approximation technique
Geomagnetic field measurements by ATS 1 in synchronous equatorial orbit, determining pulsations types during magnetically quiet and geomagnetic storm periods
Auroral pulsation analysis from rocket soundings, investigating oxygen green linear excitation sources
X ray pulsations from Cygnus X-1 observed from Uhuru satellite, suggesting exstar discovery
Large amplitude periodic X ray pulsations from Centaurus X-3, observing abrupt source intensity and pulse rate changes
Infrasonic pulsations of optical auroral luminosity in 3914 A positive molecular nitrogen ion and 5577 A O I emission measurement by double photometer system
Cygnus X-1 X ray data with temporal resolution, examining pulsations and flare activity
Circinus pulsating X ray source spectrum analysis, considering bremsstrahlung and black body models
X ray sources pulsation limits and locations determination by rocket-borne rotating modulation collimator
Unsteady gas pulsations in compliant tube, predicting pressure amplitude extremum as function of mean flow by linear theory with frictional effect
A number of total-pressure tubes were tested in a non-steady flow generator in which the fraction of period that pressure is a maximum is approximately 0.8, thereby simulating turbomachine-type flow conditions. Most of the tubes indicated a pressure which was higher than the true average. Organ-pipe resonance which further increased the indicated pressure was encountered within the tubes at discrete frequencies. There was no obvious combination of tube diameter, length, and/or geometry variation used in the tests which resulted in negligible averaging error. A pneumatic-type probe was found to measure true average pressure, and is suggested as a comparison instrument to determine whether nonlinear averaging effects are serious in unknown pulsation profiles. The experiments were performed at a pressure level of 1 bar, for Mach number up to near 1, and frequencies up to 3 kHz.
Since the discovery of the pulsations from the X-ray source Cygnus X-1 more data from Uhuru have been analyzed. The conclusions reached about the temporal behavior of the source are described. Large fluctuations of intensity exist on all observed time scales ranging from 50 msec to 10 sec containing up to 50 per cent of the power. Periodic pulse trains with periods from 0.3 sec to over 10 sec exist containing 10-25 per cent of the power; however, they persist only for several seconds or several tens of seconds. No single period is consistently present. This behavior is shown to reconcile the apparently contradictory results obtained by other observers. The energy spectrum of the source is best fitted by a power law, but with great variability in the spectral index and with an excess of flux at higher energies.
A number of total-pressure tubes were tested in a nonsteady flow generator in which the fraction of period that pressure is a maximum is approximately 0.8, thereby simulating turbomachine-type flow conditions. Most of the tubes indicated a pressure which was higher than the true average. Organ-pipe resonance which further increased the indicated pressure was encountered with the tubes at discrete frequencies. There was no obvious combination of tube diameter, length, and/or geometry variation used in the tests which resulted in negligible averaging error. A pneumatic-type probe was found to measure true average pressure and is suggested as a comparison instrument to determine whether nonlinear averaging effects are serious in unknown pulsation profiles.
A number of total-pressure tubes were tested in a nonsteady flow generator in which the fraction of period that pressure is a maximum is approximately 0.8, thereby simulating turbomachine-type flow conditions. The tests were performed at a pressure level of 1 bar, for Mach numbers up to near 1, and frequencies up to 3 kHz. Most of the tubes indicated a pressure which was higher than the true average. Organ-pipe resonances which further increased the indicated pressure were encountered within the tubes at discrete frequencies. There was no obvious combination of tube diameter, length, and/or geometry variation used in the tests which resulted in negligible averaging error. A pneumatic-type probe was found to measure true average pressure, and is suggested as a comparison instrument to determine whether nonlinear averaging effects are serious in unknown pulsation profiles.
It is postulated that worldwide transgressions (pulsations) and regressions (interpulsations) through the course of geologic time are related to the elevation and subsidence of oceanic ridge systems and to sea-floor spreading. Two multiple working hypotheses are advanced to explain major transgressions and regressions and the elevation and subsidence of oceanic ridge systems. One hypothesis interrelates the sea-floor spreading hypothesis to the hypothesis of sub-Mohorovicic serpentinization. The second hypothesis relates the sea-floor spreading hypothesis to a hypothesis involving thermal expansion and contraction.
Radio beacons with distinguishing signatures exist in nature as pulsating radio sources (pulsars). These objects radiate well determined pulse trains over hundreds of megahertz of bandwidth at radio frequencies. Since they are at known positions, they can also be used as navigation beacons in interplanetary space. Pulsar signals are weak and dispersive when viewed from earth. If an omnidirectional antenna is connected to a wideband receiver (200 MHz bandwidth centered at 200 MHz) in which dispersion effects are removed, nominal spacecraft position errors of 1500 km can be obtained after 24 h of signal integration. An antenna gain of 10 db would produce errors as low as 150 km. Since the spacecraft position is determined from the measurement of the phase of a periodic signal, ambiguities occur in the position measurement. Simultaneous use of current spacecraft navigation schemes eliminates these ambiguities.
The critical mass for stability against radial pulsations in rotating, homogeneous main-sequence stars is found to be greater than in the case of no rotation. Analytic and detailed numerical models show that the critical mass rises steeply with increasing concentration of angular momentum to the center of the star. For uniform rotation near breakup velocity at the star's equator the critical mass is about 850 solar masses if an electron-scattering opacity is used, or about 5000 solar masses if the opacities of Cox and Stewart are used. For nonuniform rotation with a constant ratio of centrifugal force to gravity in the star, the critical mass becomes 'infinite' long before breakup velocity is attained. The relevance of the present results to several observational problems is noted.
A class of unstructured Pc 1-2 pulsation activity, as identified on Bar I (70.2 N) records taken during 1968-1972, is found to be present in midday hours on about half of the days in summer months. The events have some tendency to occur in the later part of the ring current recovery phase, especially at times of moderate AE when the cleft lines are just poleward of Bar I. The source lines of the Pc 1-2 are found to lie essentially outside the plasmapause. In terms of the proton cyclotron resonance instability the most likely source regions of the Bar I Pc 1-2 are the detached plasma regions convecting sunward on the dayside and the portion of the cleft plasma on the last closed field lines.