Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PRISMS”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Targeted quantification of low ng/mL level proteins in human serum without immunoaffinity depletion

We recently reported an antibody-free targeted protein quantification strategy, termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM) for achieving significantly enhanced sensitivity using selected reaction monitoring (SRM) mass spectrometry. Integrating PRISM with front-end IgY14 immunoaffinity depletion, sensitive detection of targeted proteins at 50-100 pg/mL levels in human blood plasma/serum was demonstrated. However, immunoaffinity depletion is often associated with undesired losses of target proteins of interest. Herein we report further evaluation of PRISM-SRM quantification of low-abundance serum proteins without immunoaffinity depletion and the multiplexing potential of this technique. Limits of quantification (LOQs) at low ng/mL levels with a median CV of ~12% were achieved for proteins spiked into human female serum using as little as 2 µL serum. PRISM-SRM provided up to ~1000-fold improvement in the LOQ when compared to conventional SRM measurements. Multiplexing capability of PRISM-SRM was also evaluated by two sets of serum samples with 6 and 21 target peptides spiked at the low attomole/µL levels. The results from SRM measurements for pooled or post-concatenated samples were comparable to those obtained from individual peptide fractions in terms of signal-to-noise ratios and SRM peak area ratios of light to heavy peptides. PRISM-SRM was applied to measure several ng/mL-level endogenous plasma proteins, including prostate-specific antigen, in clinical patient sera where correlation coefficients > 0.99 were observed between the results from PRISM-SRM and ELISA assays. Our results demonstrate that PRISM-SRM can be successfully used for quantification of low-abundance endogenous proteins in highly complex samples. Moderate throughput (50 samples/week) can be achieved by applying the post-concatenation or fraction multiplexing strategies. We anticipate broad applications for targeted PRISM-SRM quantification of low-abundance cellular proteins in systems biology studies as well as candidate biomarkers in biofluids.

Environmental Molecular Sciences Laboratory↗

Ionospheric calibration for single frequency altimeter measurements

This study is a preliminary analysis of the effectiveness (in terms of altimeter calibration accuracy) of various ionosphere models and the Global Positioning System (GPS) to calibrate single frequency altimeter height measurements for ionospheric path delay. In particular, the research focused on ingesting GPS Total Electron Content (TEC) data into the physical Parameterized Real-Time Ionospheric Specification Model (PRISM), which estimates the composition of the ionosphere using independent empirical and physical models and has the capability of adjusting to additional ionospheric measurements. Two types of GPS data were used to adjust the PRISM model: GPS receiver station data mapped from line-of-sight observations to the vertical at the point of interest and a grid map (generated at the Jet Propulsion Laboratory) of GPS derived TEC in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by the International Reference Ionosphere (IRI-90), a climatological (monthly mean) model of the ionosphere, were compared to TOPEX dual-frequency TEC measurements (considered as truth) for a number of TOPEX sub-satellite tracks. For a 13.6 GHz altimeter, a Total Electron Content (TEC) of 1 TECU 10(exp 16) electrons/sq m corresponds to approximately 0.218 centimeters of range delay. A maximum expected TEC (at solar maximum or during solar storms) of 10(exp 18) electrons/sq m will create 22 centimeters of range delay. Compared with the TOPEX data, the PRISM predictions were generally accurate within the TECU when the sub-satellite track of interest passed within 300 to 400 km of the GPS TEC data or when the track passed through a night-time ionosphere. If neither was the case, in particular if the track passed through a local noon ionosphere, the PRISM values differed by more than 10 TECU and by as much as 40 TECU. The IRI-90 model, with no current ability to unseat GPS data, predicted TEC to a slightly higher error of 12 TECU. The performance of PRISM is very promising for predicting TEC and will prove useful for calibrating single frequency altimeter height measurements for ionospheric path delay. When adjusted to the GPS line-of-sight data the PRISM URSI empirical model predicted TEC over a day's period to within a global error of 8.60 TECU rms during a nighttime ionosphere and 9.74 TECU rms during the day. When adjusted to the GPS derived TEC grid, the PRISM parametrized model predicted TEC to within an error of 8.47 TECU rms for a nighttime ionosphere and 12.83 TECU rms during the day. However, the grid cannot be considered globally due to the lack of sufficient numbers of GPS stations and large latitude gaps in GPS data. It is the opinion of the authors that using the PRISM model and adjusting to the global sun-fixed TEC grid regenerated with a localized weighted interpolation offers the best possibility of meeting the 10 TECU global rms (or 2 cm at 13.6 GHz) ionosphere range correction accuracy requirement of TOPEX/Poseidon and should be the subject of further study. However, it is clear that the anticipated requirement of 34 TECU global rms for TOPEX/Poseidon Follow-On (corresponding to the TOPEX/Poseidon performance) can not be met with any realizable combination of existing models and data assimilation schemes.

Schreiner, William S.↗

Optical alignment of Centaur's inertial guidance system

During Centaur launch operations the launch azimuth of the inertial platform's U-accelerometer input axis must be accurately established and maintained. This is accomplished by using an optically closed loop system with a long-range autotheodolite whose line of sight was established by a first-order survey. A collimated light beam from the autotheodolite intercepts a reflecting Porro prism mounted on the platform azimuth gimbal. Thus, any deviation of the Porro prism from its predetermined heading is optically detected by the autotheodolite. The error signal produced is used to torque the azimuth gimbal back to its required launch azimuth. The heading of the U-accelerometer input axis is therefore maintained automatically. Previously, the autotheodolite system could not distinguish between vehicle sway and rotational motion of the inertial platform unless at least three prisms were used. One prism was mounted on the inertial platform to maintain azimuth alignment, and two prisms were mounted externally on the vehicle to track sway. For example, the automatic azimuth-laying theodolite (AALT-SV-M2) on the Saturn vehilce used three prisms. The results of testing and modifying the AALT-SV-M2 autotheodolite to simultaneously monitor and maintain alignment of the inertial platform and track the sway of the vehicle from a single Porro prism.

Gordan, Andrew L.↗

Ionospheric calibration for single frequency altimeter measurements

This report investigates the potential of using Global Positioning System (GPS) data and a model of the ionosphere to supply a measure of the sub-satellite Total Electron Current (TEC) of the required accuracy (10 TECU rms) for the purpose of calibrating single frequency radar altimeter measurements. Since climatological (monthly mean) models are known to be in error by as much as 50 percent, this work focused on the Parameterized Real-Time Ionospheric Specification Model (PRISM) which has the capability to improve model accuracy by ingesting (adjusting to) in situ ionospheric measurements. A set of globally distributed TEC measurements were generated using GPS data and were used as input to improve the accuracy of the PRISM model. The adjusted PRISM TEC values were compared to TOPEX dual frequency TEC measurements (which are considered truth) for a number of TOPEX sub-satellite tracks. The adjusted PRISM values generally compared to the TOPEX measurements within the 10 TECU accuracy requirements when the sub-satellite track passed within 300 to 400 km of the GPS TEC data or when the track passed through a night time ionosphere. However, when the sub-satellite points were greater than 300 to 400 km away from the GPS TEC data or when a local noon ionosphere was sampled, the adjusted PRISM values generally differed by greater than 10 TECU rms with data excursions from the TOPEX TEC measurements of as much as 40 TECU (an 8 cm path delay error at K band). Therefore, it can be concluded from this analysis that an unrealistically large number of GPS stations would be needed to predict sub-satellite TEC at the 10 TECU level in the day time ionosphere using a model such as PRISM. However, a technique currently being studied at the Jet Propulsion Laboratory (JPL) may provide a means of supplying adequate TEC data to meet the 10 TECU ionospheric correction accuracy when using a realistic number of ionospheric stations. This method involves using global GPS TEC data to estimate a global grid of vertical ionospheric TEC as a function of time (i.e. every one half hour) in a sun-fixed longitude frame. Working in a sun-fixed longitude frame, one is not limited by the spatial decorrelation distance of the ionosphere, but instead is limited more by the temporal correlations of the ionosphere in the sun-fixed frame which are a smaller effect. It is the opinion of the authors that using the global sun-fixed TEC grid data, in particular, ingesting it into PRISM, offers the best possibility of meeting the 10 TECU ionospheric correction accuracy requirement, and should be the subject of further study.

Schreiner, William S.↗

A Countermeasure for Space Motion Sickness

Overall, the results obtained in both the U.S. and the Russian space programs indicate that most space crews will experience some symptoms of motion sickness (MS) causing significant impact on the operational objectives that must be accomplished to assure mission success. At this time the primary countermeasure for MS requires the administration of Promethazine. Promethazine is not a benign drug, and is most frequently administered just prior to the sleep cycle to prevent its side effects from further compromising mission objectives. Clearly other countermeasures for SMS must be developed. Currently the primary focus is on two different technologies: (1) developing new and different pharmacological compounds with less significant side effects, (2) preflight training. The primary problem with all of these methods for controlling MS is time. New drugs that may be beneficial are years from testing and development, and preflight training requires a significant investment of crew time during an already intensive pre-launch schedule. Granted, motion sickness symptoms can be minimized with either of the two methods detailed above, however, it may be possible to develop a countermeasure that does not require either extensive adaptation time or exposure to motion sickness. Approximately 25 years ago Professor Geoffrey Melvill Jones presented his work on adaptation of the vestibuloocular reflex (VOR) using optically reversed vision (left-right prisms) during head rotations in the horizontal plane. It was of no surprise that most subjects experienced motion sickness while wearing the optically reversing prisms. However, a serendipitous finding emerged during this research showing that the same subjects did not experience motion sickness symptoms when wearing the reversing prisms under stroboscopic illumination. The mechanism, by which this side-effect was believed to have occurred, is not clearly understood. However, the fact that no motion sickness was ever noted, suggests the possibility of producing functionally useful adaptation during space flight without the penalty of disabling motion sickness by controlling the rate of the adaptive process by means of an appropriate stroboscopically presented environment. After several recent meetings with Professor Melvill Jones, we were encouraged to repeat the motion sickness portions of his and Mandl's 1981 stroboscopic experiment. In conducting this experiment we used a randomized cross-over design where subjects were randomly assigned to either a stroboscopic flash or no strobe for their first exposure in the experimental design. Twenty subjects (19 subjects completed the study) read a short passage from Treasure Island mounted on the wall approximately 1 m from their eyes while wearing left-right reversing prisms. The strobe on time of 3 microseconds and flash frequency of 4 Hz was set to equal that used in the original study. Motion sickness was scored using a modified Miller and Graybiel scale that we constructed to include symptoms that may be elicited under conditions where reversing prisms are worn. On this scale a score of 5 represented Malaise IIa (mild motion sickness) and a score of 8 or above is approaching frank sickness. Symptoms were tracked and recorded every 5 min during the task. Testing was limited to 30 min unless the subject had reached the MIIa score, at which time the test was terminated. Performance under stroboscopic illumination was significantly better than when the subjects read under normal room illumination while wearing the left-right reversing prisms. Based on these results we developed a goggle system using LCD material that can be strobed. To evaluate the effectiveness of stroboscopic goggles we tested an additional 9 subjects in addition to retesting 10 used in the stroboscopic pilot study described above. These 19 subjects wore a pair of strobing LCD goggles that could be cycled at 4 Hz. These subjects wore the goggles while also wearing left-right reversg prisms. Results while wearing the goggles showed that none of the 19 subjects scored at the MIIa level on the motion sickness rating scale. When the goggles did not flash (no strobe), 11 of the 19 developed symptoms above the MIIa criteria. As a countermeasure the goggles seem to be effective, even with an on time of 10 msec (time the goggles are clear). We have also collected anecdotal data, from our personnel in the Neuroscience Laboratory at the Johnson Space Center, suggesting that the goggles may effective in preventing carsickness.

Reschke, M. F.↗

Performance Risk Model Validation with Operationally Relevant Tasks

Human Research Program aims to develop methods to support astronauts’ health and productivity during spaceflight. The Crew Health and Performance Probabilistic Risk Assessment (CHP-PRA) team uses powerful computational methods to predict mission risk in both domains: medical and performance. Here, we show how CHP-PRA uses the Performance Risk Model (PRisM) to quantify the performance risk and show an application of the model on operationally relevant tasks. There are various metrics adopted across performance researchers that PRisM can accommodate. For data analysis, interpretation, and integration, we use a method of unifying data from multiple sources by converting each to a single metric. We consult subject matter experts prior to integrating the converted data into PRisM. The method we use is inspired by the Cooper-Harper rating scale [1]. Using this unified metric, we can easily combine data from various tests and lab groups. We explain our conversion method in detail and show how it pertains to the process of testing and validation of PRisM on operational tasks. We conducted an initial validation in collaboration with the Behavioral Health and Performance (BHP) lab. We test PRisM using data on their operationally relevant task ROBoT-r, a track-and-capture task for grappling incoming resupply vehicles [2]. Several other labs at NASA Johnson Space Center worked together to design 7 Functional Task Tests (FTTs) in pursuit of simulating the tasks required after landing on a planetary surface and after return to Earth [3]. Here we use the results from both ROBoT-r and the 7 FTTs and compare their experiment data to PRisM’s computational output to demonstrate how PRisM can support operations by predicting crew performance on future missions.

performance modeling↗

Calcite Twinning in Mollusk Shells and Carrara Marble

Mollusk shells protect the animals that form and inhabit them. They are composites of minerals and organics, with diverse mesostructures, including nacre, prismatic calcite, crossed-lamellar aragonite, and foliated calcite. Twins, that is, crystals mirror symmetric with respect to their coherent interface, occurring as formation or deformation twins, are observed in all mollusk shell mesostructures but never within calcite prisms. Here, nanotwins and microwins within single calcite prisms are observed in different shells. Using Polarization-dependent Imaging Contrast (PIC) mapping with 20–60 nm resolution, twins are observed to be 0.2–3 µm thick layers of differently oriented and colored crystals with respect to the main prism crystal. Multiple twins are interspersed with the prism crystal, parallel to one another, and similarly oriented. When comparing images of calcite prisms and twins obtained by PIC mapping and by Electron Back-Scattered Diffraction (EBSD), the images correspond precisely. All twins are e-twin types, with 127° angular distance between c-axes. E-twins are the most common deformation twins in geologic calcite, as also observed here in Carrara marble. Location of all twins near the outer surface of all shells and e-twin type both suggest that twins within calcite prisms in mollusk shells result from deformation twinning.

36 MATERIALS SCIENCE↗

Sensitive Targeted Quantification of ERK Phosphorylation Dynamics and Stoichiometry in Human Cells without Affinity Enrichment

Mass spectrometry-based targeted quantification is a promising technology for site-specific quantification of posttranslational modifications (PTMs). However, a major constraint of most targeted MS approaches is the limited sensitivity for quantifying low-abundance PTMs, requiring the use of affinity reagents to enrich specific PTMs. Herein, we demonstrate the direct site-specific quantification of ERK phosphorylation isoforms (pT, pY, pTpY) and their relative stoichiometries using a highly sensitive targeted MS approach termed high-pressure, high-resolution separations with intelligent selection and multiplexing (PRISM). PRISM provides effective enrichment of target peptides within a given fraction from complex biological matrix with minimal sample losses, followed by selected reaction monitoring (SRM) quantification. The PRISM-SRM approach enabled direct quantification of ERK phosphorylation in human mammary epithelial cells (HMEC) from as little as 25 µg tryptic peptides from whole cell lysates. Compared to immobilized metal-ion affinity chromatography, PRISM provided >10-fold improvement in signal intensities, presumably due to the better peptide recovery of PRISM for handling small size samples. This approach was applied to quantify ERK phosphorylation dynamics in HMEC treated by different doses of EGF at both the peak activation (10 min) and steady state (2 h). At 10 min, the maximal ERK activation was observed with 0.3 ng/mL dose, whereas the maximal steady state level of ERK activation at 2 h was at 3 ng/ml dose, corresponding to 1200 and 9000 occupied receptors, respectively. At 10 min, the maximally activated pTpY isoform represented ~40% of total ERK, falling to less than 10% at 2 h. The time course and dose-response profiles of individual phosphorylated ERK isoforms indicated that singly phosphorylated pT-ERK never increases significantly, while the increase of pY-ERK paralleled that of pTpY-ERK. This data supports for a processive, rather than distributed, model of ERK phosphorylation. The PRISM-SRM quantification of protein phosphorylation illustrates the potential for simultaneous quantification of multiple PTMs.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A comparative study of spherical and flat-Earth geopotential modeling at satellite elevations

Flat-Earth modeling is a desirable alternative to the complex spherical-Earth modeling process. These methods were compared using 2 1/2 dimensional flat-earth and spherical modeling to compute gravity and scalar magnetic anomalies along profiles perpendicular to the strike of variably dimensioned rectangular prisms at altitudes of 150, 300, and 450 km. Comparison was achieved with percent error computations (spherical-flat/spherical) at critical anomaly points. At the peak gravity anomaly value, errors are less than + or - 5% for all prisms. At 1/2 and 1/10 of the peak, errors are generally less than 10% and 40% respectively, increasing to these values with longer and wider prisms at higher altitudes. For magnetics, the errors at critical anomaly points are less than -10% for all prisms, attaining these magnitudes with longer and wider prisms at higher altitudes. In general, in both gravity and magnetic modeling, errors increase greatly for prisms wider than 500 km, although gravity modeling is more sensitive than magnetic modeling to spherical-Earth effects. Preliminary modeling of both satellite gravity and magnetic anomalies using flat-Earth assumptions is justified considering the errors caused by uncertainties in isolating anomalies.

Parrott, M. H.↗

Tetravalent chromium (Cr(4+)) as laser-active ion for tunable solid-state lasers

Major accomplishments under NASA grant NAG-1-1346 are summarized. (1) numerical modeling of the four mirror astigmatically compensated, Z-fold cavity was performed and several design parameters to be used for the construction of a femtosecond forsterite laser were revealed by simulation. (2) femtosecond pulses from a continuous wave mode-locked chromium doped forsterite laser were generated. The forsterite laser was actively mode-locked using an acousto-optic modulator operating at 78 MHz with two Brewster high dispersion glass prisms for intra-cavity chirp compensation. Transform-limited sub-100-fs pulses were routinely generated in the TEM(sub 00) mode with 85 mW of continuous power tunable over 1230-1280 nm. The shortest pulses of 60-fs pulsewidth were measured. (3) Self-mode-locked operation of the Cr:forsterite laser was achieved. Synchronous pumping was used to mode lock the forsterite laser resulting in picosecond pulses, which in turn provided the starting mechanism for self-mode-locking. The pulses generated had an FWHM of 105 fs and were tunable between 1230-1270 nm. (4) Numerical calculations indicated that the pair of SF 14 prisms used in the cavity compensated for quadratic phase but introduced a large cubic phase term. Further calculations of other optical glasses indicated that a pair of SFN 64 prisms can introduce the same amount of quadratic phase as SF 14 prisms but introduce a smaller cubic phase. When the SF 14 prisms were replaced by SFN 64 prisms the pulsewidth was reduced to 50 fs. Great improvement was observed in the stability of the self mode-locked forsterite laser and in the ease of achieving mode locking. Using the same experimental arrangement and a new forsterite crystal with improved FOM the pulse width was reduced to 36 fs.

Seas, A.↗

Laboratory Testing and Performance Verification of the CHARIS Integral Field Spectrograph

The Coronagraphic High Angular Resolution Imaging Spectrograph (CHARIS) is an integral field spectrograph (IFS) that has been built for the Subaru telescope. CHARIS has two imaging modes; the high-resolution mode is R82, R69, and R82 in J, H, and K bands respectively while the low-resolution discovery mode uses a second low-resolution prism with R19 spanning 1.15-2.37 microns (J+H+K bands). The discovery mode is meant to augment the low inner working angle of the Subaru Coronagraphic Extreme Adaptive Optics (SCExAO) adaptive optics system, which feeds CHARIS a coronagraphic image. The goal is to detect and characterize brown dwarfs and hot Jovian planets down to contrasts five orders of magnitude dimmer than their parent star at an inner working angle as low as 80 milliarcseconds. CHARIS constrains spectral crosstalk through several key aspects of the optical design. Additionally, the repeatability of alignment of certain optical components is critical to the calibrations required for the data pipeline. Specifically the relative alignment of the lens let array, prism, and detector must be highly stable and repeatable between imaging modes. We report on the measured repeatability and stability of these mechanisms, measurements of spectral crosstalk in the instrument, and the propagation of these errors through the data pipeline. Another key design feature of CHARIS is the prism, which pairs Barium Fluoride with Ohara L-BBH2 high index glass. The dispersion of the prism is significantly more uniform than other glass choices, and the CHARIS prisms represent the first NIR astronomical instrument that uses L-BBH2as the high index material. This material choice was key to the utility of the discovery mode, so significant efforts were put into cryogenic characterization of the material. The final performance of the prism assemblies in their operating environment is described in detail. The spectrograph is going through final alignment, cryogenic cycling, and is being delivered to the Subaru telescope in April 2016. This paper is a report on the laboratory performance of the spectrograph, and its current status in the commissioning process so that observers will better understand the instrument capabilities. We will also discuss the lessons learned during the testing process and their impact on future high-contrast imaging spectrographs for wavefront control.

Coronagraphic High Angular Resolution Imaging Spec↗

Nano-scale microstructure damage by neutron irradiations in a novel Boron-11 enriched TiB 2 ultra-high temperature ceramic

Ultra-high temperature transition-metal ceramics are potential candidates for fusion reactor structural and plasma-facing components. We reveal the irradiation damage microstructural phenomena in Boron-11 enriched titanium diboride (TiB 2 ) using mixed-spectrum neutron irradiations, combined with state-of-art characterization using transmission electron microscopy (TEM) and high resolution TEM. Irradiations were performed using High Flux Isotope Reactor at ~220 and 620 °C up to 2.4 x 10 25 n.m -2 (E > 0.1 MeV). The calculated dose including contribution from residual Boron-10 ( 10 B) transmutation recoils, was ~4.2 displacements per atom. TiB 2 is susceptible to irradiation damage in terms of dislocation loop formation, cavities and anisotropic swelling induced micro-cracking. At both 220 and 620 °C, TEM revealed dislocation loops on basal and prism planes, with nearly two orders of magnitude higher number density of prism-plane loops. HRTEM, electron diffraction and relrod imaging revealed additional defects on {10$ \overline{1}\ $0} planes, identified as faulted prism-plane dislocation loops. High defect cluster density on prism planes will induce a-lattice parameter swelling of TiB 2 , as reported in literature. This anisotropic lattice parameter swelling induced grain boundary micro-cracking, the extent of which decreased with increasing irradiation temperature. The dominance of irradiation defect clusters on prism planes is different than typical hexagonal ceramics where dislocation loops predominantly form on basal planes, causing c-lattice parameter swelling. Helium generation and temperature rise from the transmutation of residual 10 B resulted in matrix and grain boundary cavities for the irradiation at 620 °C. In conclusion, the study additionally signifies isotopic enrichment as a viable approach to produce transition-metal diborides for potential nuclear structural applications.

36 MATERIALS SCIENCE↗

Phase diagram of SrO-InO{sub 1.5}-CoO{sub x} and a new compound Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6}

Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6}, isostructural to Ca{sub 3}Co{sub 2}O{sub 6}, is revealed by the study of the phase relations in the system SrO-InO{sub 1.5}-CoO{sub x} (1000 {sup o}C). The structure of Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} is refined by the combination of powder X-ray and neutron diffraction. Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} crystallizes in a trigonal lattice with the cell parameters a=b=9.59438(3) A, c=11.02172(4) A with the space group R-3c. Its structure possesses 1D (In/Co)O{sub 3} chains running along the c-axis constructed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms. The co-occupation of In{sup 3+} and Co{sup 3+} at the trigonal prismatic site is evidenced by elementary analysis and determined by the structure refinement. Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} is paramagnetic, and the susceptibility is consistent with the occupation of Co{sup 3+} at 10% of the trigonal prismatic positions in a high spin state (HS, S=2). The HS Co{sup 3+} is well separated by diamagnetic CoO{sub 6} octahedra and InO{sub 6} trigonal prisms and shows a g factor of 2.0 in the magnetic measurements. -- Graphical abstract: Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} possesses 1D chains constructed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms. The high spin Co{sup 3+} (S=2) in trigonal prism shows a g factor of 2.0. Display Omitted Research highlights: {yields} Phase diagram of SrO-InO{sub 1.5-}CoO{sub x} at 1000 {sup o}C in air atmosphere is presented. {yields} A new compound Sr{sub 3}In{sub 0.9}Co{sub 1.1}O{sub 6} that is isostructural to Ca{sub 3}Co{sub 2}O{sub 6} is revealed. {yields} 1D chain is formed by alternating face-sharing CoO{sub 6} octahedra and (In{sub 0.9}Co{sub 0.1})O{sub 6} trigonal prisms.{yields} Co{sup 3+} at trigonal prismatic site is in high spin state (S=2) with a g factor of 2.0.

36 MATERIALS SCIENCE↗

A Fast Algorithm for Scanning Transmission Electron Microscopy Imaging and 4D-STEM Diffraction Simulations

Scanning transmission electron microscopy (STEM) is an extremely versatile method for studying materials on the atomic scale. Many STEM experiments are supported or validated with electron scattering simulations. However, using the conventional multislice algorithm to perform these simulations can require extremely large calculation times, particularly for experiments with millions of probe positions as each probe position must be simulated independently. Recently, the plane-wave reciprocal-space interpolated scattering matrix (PRISM) algorithm was developed to reduce calculation times for large STEM simulations. Here, we introduce a new method for STEM simulation: partitioning of the STEM probe into “beamlets,” given by a natural neighbor interpolation of the parent beams. This idea is compatible with PRISM simulations and can lead to even larger improvements in simulation time, as well requiring significantly less computer random access memory (RAM). We have performed various simulations to demonstrate the advantages and disadvantages of partitioned PRISM STEM simulations. We find that this new algorithm is particularly useful for 4D-STEM simulations of large fields of view. We also provide a reference implementation of the multislice, PRISM, and partitioned PRISM algorithms.

97 MATHEMATICS AND COMPUTING↗

TH-A-BRF-08: Deformable Registration of MRI and CT Images for MRI-Guided Radiation Therapy

Purpose: To evaluate the quality of a commercially available MRI-CT image registration algorithm and then develop a method to improve the performance of this algorithm for MRI-guided prostate radiotherapy. Methods: Prostate contours were delineated on ten pairs of MRI and CT images using Eclipse. Each pair of MRI and CT images was registered with an intensity-based B-spline algorithm implemented in Velocity. A rectangular prism that contains the prostate volume was partitioned into a tetrahedral mesh which was aligned to the CT image. A finite element method (FEM) was developed on the mesh with the boundary constraints assigned from the Velocity generated displacement vector field (DVF). The resultant FEM displacements were used to adjust the Velocity DVF within the prism. Point correspondences between the CT and MR images identified within the prism could be used as additional boundary constraints to enforce the model deformation. The FEM deformation field is smooth in the interior of the prism, and equal to the Velocity displacements at the boundary of the prism. To evaluate the Velocity and FEM registration results, three criteria were used: prostate volume conservation and center consistence under contour mapping, and unbalanced energy of their deformation maps. Results: With the DVFs generated by the Velocity and FEM simulations, the prostate contours were warped from MRI to CT images. With the Velocity DVFs, the prostate volumes changed 10.2% on average, in contrast to 1.8% induced by the FEM DVFs. The average of the center deviations was 0.36 and 0.27 cm, and the unbalance energy was 2.65 and 0.38 mJ/cc3 for the Velocity and FEM registrations, respectively. Conclusion: The adaptive FEM method developed can be used to reduce the error of the MIbased registration algorithm implemented in Velocity in the prostate region, and consequently may help improve the quality of MRI-guided radiation therapy.

60 APPLIED LIFE SCIENCES↗

Analytical platform evaluation for quantification of ERG in prostate cancer using protein and mRNA detection methods

Background: The established methods for detecting prostate cancer (CaP) are based on tests using PSA (blood), PCA3 (urine), and AMACR (tissue) as biomarkers in patient samples. The demonstration of ERG oncoprotein overexpression due to gene fusion in CaP has thus provided ERG as an additional biomarker. Based on this, we hypothesized that ERG protein quantification methods can be of use in the diagnosis of prostate cancer. Methods: Therefore, an antibody-free assay for ERG3 protein detection was developed based on PRISM (high-pressure high-resolution separations with intelligent selection and multiplexing)-SRM (selected reaction monitoring) mass spectrometry. We utilized TMPRSS2-ERG positive VCaP and TMPRSS2-ERG negative LNCaP cells to simulate three different sample types (cells, tissue, and post-DRE urine sediment). Results: Recombinant ERG3 protein spiked into LNCaP cell lysates could be detected at levels as low as 20 pg by PRISM-SRM analysis. The sensitivity of the PRISM-SRM assay was around approximately 10,000 VCaP cells in a mixed cell population model of VCaP and LNCaP cells. Interestingly, ERG protein could be detected in as few as 600 VCaP cells spiked into female urine. The sensitivity of the in-house enzyme-linked immunosorbent assay (ELISA) was similar to the PRISM-SRM assay, with detection of 30 pg of purified recombinant ERG3 protein and 10,000 VCaP cells. On the other hand, qRT-PCR exhibited a higher sensitivity, as TMPRSS2-ERG transcripts were detected in as few as 100 VCaP cells, in comparison to NanoString methodologies which detected ERG from 10,000 cells. Conclusions: Based on this data, we propose that the detection of both ERG transcriptional products with RNA-based assays, as well as protein products of ERG using PRISM-SRM assays, may be of clinical value in developing diagnostics and prognostics assays for prostate cancer given their sensitivity, specificity, and reproducibility.

59 BASIC BIOLOGICAL SCIENCES↗

Development of an Enhanced Radiation Physics Toolset for Modeling Spectral and Imaging Signatures in the Warm Dense Matter Experiments

Radiative and atomic processes in plasmas play a critical role in a wide variety of high energy density laboratory plasma (HEDLP) experiments. The emission, absorption, and transport of radiation can strongly affect the overall energetics and evolution of such plasmas. In addition, radiation-based diagnostics – including imaging, spectroscopy, and absolute flux measurements – are widely used to determine key features of HEDLPs. To advance our understanding of HEDLP science, it is vital to have high-fidelity computational physics tools that have well-tested radiation physics modeling, and that are readily accessible to researchers in the HEDLP community. Simulations play an extremely important role for planning and designing the experiments, as well as for post-experiment data analysis. Prism Computational Sciences develops software that is used by National Laboratories and universities (including five members of LaserNetUS network). Prominent examples of such research efforts include z-pinch and short-pulse laser experiments designed to study the basic physics of photoionized plasmas and photoionization fronts, as well as their application to astrophysical plasmas. The main effort was dedicated to the development of non-equilibrium equation-of-state (EOS) models within the HELIOS-CR code, a hydrodynamics code with inline collisional-radiative atomic kinetics. Gas cell experiments on Z and Omega demonstrated the importance of non-equilibrium effects on atomic kinetics in photoionized plasmas. Recent proof-of-principle experiments on Omega EP confirmed the advantages of using a short-pulse laser to create an intense radiation drive, leading to additional experiments being proposed. Photoionization front experiments at LLE also emphasizes the importance of radiation and atomic physics. In both studies, HELIOS-CR simulations played a crucial role in computing non-equilibrium opacities and ionization distributions. A newly developed non-LTE EOS model will help addressing possible non-equilibrium effects, on for example specific heat, and their influence in plasma evolution. Prism also implemented support for open-source atomic data generated by the Flexible Atomic Code. This allows researchers to generate custom atomic tables and use them within the complex framework of simulation tools developed by Prism. The ability to use open-source atomic data would be extremely valuable for hydrodynamics and spectroscopic simulations that include high-Z materials, e.g., picosecond x-ray pulse generation experiments. Support for new atomic structures was fully implemented, and the data can be used by all simulation tools developed at Prism: radiation-hydrodynamics, imaging and spectroscopy, EOS and opacity. The development resulted in a significant fidelity enhancement to the simulations tools developed by Prism that are currently used in other cutting-edge experiments including: opacity measurement experiments performed to both understand the basic radiative and atomic properties of plasmas as well as provide data for more accurately modeling the internal structure of the Sun and other stars, high-intensity short-pulse laser experiments performed to develop short-wavelength light sources for use as backlighters and to investigate fast ignition concepts for inertial fusion energy; capsule implosion experiments designed to develop inertial fusion as an energy source, etc.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Correction of Single Frequency Altimeter Measurements for Ionosphere Delay

This study is a preliminary analysis of the accuracy of various ionosphere models to correct single frequency altimeter height measurements for Ionospheric path delay. In particular, research focused on adjusting empirical and parameterized ionosphere models in the parameterized real-time ionospheric specification model (PRISM) 1.2 using total electron content (TEC) data from the global positioning system (GPS). The types of GPS data used to adjust PRISM included GPS line-of-sight (LOS) TEC data mapped to the vertical, and a grid of GPS derived TEC data in a sun-fixed longitude frame. The adjusted PRISM TEC values, as well as predictions by IRI-90, a climatotogical model, were compared to TOPEX/Poseidon (T/P) TEC measurements from the dual-frequency altimeter for a number of T/P tracks. When adjusted with GPS LOS data, the PRISM empirical model predicted TEC over 24 1 h data sets for a given local time to with in a global error of 8.60 TECU rms during a midnight centered ionosphere and 9.74 TECU rms during a noon centered ionosphere. Using GPS derived sun-fixed TEC data, the PRISM parameterized model predicted TEC within an error of 8.47 TECU rms centered at midnight and 12.83 TECU rms centered at noon. From these best results, it is clear that the proposed requirement of 3-4 TECU global rms for TOPEX/Poseidon Follow-On will be very difficult to meet, even with a substantial increase in the number of GPS ground stations, with any realizable combination of the aforementioned models or data assimilation schemes.

Schreiner, William S.↗