Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PPb”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

225 records · Page 13

THE POTENTIAL FOR REUSE OF PRODUCED WATER IN THE CRITICAL MINERALS SUPPLY CHAIN IN THE POWDER RIVER BASIN OF WYOMING AND MONTANA

The Powder River Basin (PRB) Carbon Ore, Rare Earth, and Critical Minerals (CORE-CM) project is part of the Department of Energy sponsored CORE-CM initiative focused on domestic production of critical minerals and promoting economic development in traditionally fossil fuel producing basins. An important part of this project is regional assessment of waste streams and development of basinal strategies for waste stream reuse within the critical minerals (CM) supply chain. The availability of water for all parts of the CM supply chain is of particular concern in the arid mountain west. In the Wyoming PRB, average annual production of produced water (PW) by the oil and gas industry is more than 16 billion gallons (2015-2022). Through published data and engagement with industry partners, we conducted a preliminary investigation of PW in the PRB to understand volumes, quality, and the potential for use in the CM supply chain. PW was assessed for potential as a direct feedstock and for use in CM processing of a variety of conventional and unconventional feedstocks, including ore from the Bear Lodge Alkaline Complex, coal, and coal byproducts. Preliminary findings suggest that PRB PW contains significantly lower concentrations of rare earth elements (REE) and lithium than would be considered economic at this time. For example, concentrations of REE+Sc measured in PRB PW are <1 ppb (DE-EE0007603), and only seven PRB PW samples reported in the USGS PW database had lithium concentrations ≥50 ppm. However, enrichment of CM in residual brine and sludge from PW evaporation and solidification treatment ponds may yield concentrations of interest over a pond lifetime and should be considered in future studies. Coal bed methane (CBM) PW accounted for 42% of all PW in the Wyoming PRB in 2022. Compared to non-CBM PW, PRB CBM water quality generally meets standards allowing surface discharge and reuse in local industries such as livestock. CBM PW may help to fill water needs within the CM supply chain. Understanding the distribution of CBM PW that is discharged versus reused will help develop basinal reuse strategies.

Jackson, Lily↗

Probabilistic Groundwater Modeling of the RDX Plume at Los Alamos National Laboratory to Support Risk Assessment - 20359

A plume of the contaminant hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) with concentrations greater than the New Mexico tap water drinking standard (9.66 ppb) is present in the regional aquifer near the southwestern boundary of Los Alamos National Laboratory (LANL). A risk assessment is performed for exposure to regional aquifer groundwater, with long-term predictions of RDX concentrations provided by a calibrated, probabilistic, numerical fate and transport model. The structure of the model is hierarchical, with the RDX Regional Aquifer (RA) groundwater model acting as the primary tool for analysis of downgradient RDX concentrations. The RA model is deeply informed by the conceptual site model (CSM) and is calibrated using site RDX concentration data and hydraulic head measurements, along with other analyses. The model is calibrated using data through December 2019. Where data are scarce other lines of evidence are used to inform inputs, including the multiphase RDX Vadose Zone (VZ) model and Pipe and Disk analytical screening tool. Model inputs are described with informative prior distributions using a robust approach to development that incorporates all available lines of evidence for every parameter used as an input to the RA model. Calibration is performed using a classical nonlinear optimization routine, which is then used to initialize a Bayesian calibration. The Bayesian calibration constrains the uncertainty in the classical calibration, ultimately providing posterior distributions for all model parameters. The challenges of the calibration include high-dimensional parameter space, including spatially heterogeneous hydraulic conductivities, comparatively sparse data, and low RDX concentrations. Posterior parameter distributions developed in the calibration process are then used for stochastic predictive model runs into the future. The result of the forward runs is spatially and temporally explicit estimates of head and concentration with uncertainty at all points in space and time. The probabilistic modeling approach presented here includes innovative computational and statistical methods that leverage high-performance computing (HPC) resources. It makes use of prior modeling work performed at the chromium plume site in the central LANL area, with extensive updates. The risk assessment will ultimately be used to support decision-making at the site, using multiple appropriately weighted sources of information, as well as uncertainty, sensitivity, and value-of-information analyses. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Analysis of Hydrology and Interim Measure Performance in the Chromium Plume at Los Alamos National Laboratory - 20498

Hexavalent chromium, Cr(VI), is present in the regional aquifer beneath Los Alamos National Laboratory (LANL) at concentrations greater than the New Mexico groundwater standard (50 ppb). The source of the Cr is blowdown from a power plant where potassium dichromate was used as a corrosion inhibitor from 1956 to 1972. Blowdown comingled with effluent from another source and migrated approximately 3 miles down a canyon, primarily as surface flow, until reaching an alluvial infiltration zone. The infiltrating water moved vertically through a thick (approximately 900 ft), complex stratigraphic sequence of unsaturated tuffs, basalt, and unconsolidated alluvial deposits. Horizontal transport also took place within spatially limited perched groundwater horizons in the vadose zone (VZ). Breakthrough at the regional aquifer water table is thought to have occurred in multiple hydraulic windows or 'drip points' located approximately 3 miles from the initial release site at the power plant. The regional aquifer is highly heterogeneous and anisotropic, and displays unconfined behavior in an upper zone and confined behavior at depth. The Cr(VI) contamination has so far remained confined to the upper approximately 25 m of the aquifer. The ambient hydraulic gradient in the regional aquifer is toward the east/southeast, but the water table is extremely flat in the Cr plume area compared to surrounding areas. There is some local variability in flow direction, potentially related to effects of seasonal pumping from nearby Los Alamos county water-supply wells, which draw from the regional aquifer several hundred feet below the water table. An interim measure (IM) is currently operating at the site to achieve hydraulic control of plume migration using a series of extraction wells, ion-exchange treatment, and injection along the downgradient portion of the plume. The migration of Cr contamination in the aquifer has been previously evaluated using a calibrated probabilistic numerical model, which has also been used to design the spatial configuration of extraction and injection wells for the IM, and to identify locations for monitoring wells. The model is built using the Finite Element Heat and Mass (FEHM) transfer code, and the Model Analysis and Decision Support (MADS) software is used for analyses. To date, the portion of the IM system that has operated in a continuous manner has been very effective at hydraulic control. Modifications to the flow field associated with the influence of IM pumping and injection are evaluated here, with modeling constraints to be provided by recent observations of tracers injected into both monitoring wells and IM injection wells, as well as opportunistic observations of geochemical signatures of treated ion-exchange effluent injected into IM injection wells. The tracer and geochemical data provide insights into modified flow directions within the Cr plume area that cannot be otherwise obtained. Results of the modeling work are being used to inform adaptive management of IM operations and will be a valuable tool for development and refinement of long-term remediation strategies. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Multi-functional Sorbent Technology (MUST) for the Recovery/Removal of Critical/Heavy Metals from Fossil-Related Wastewater

A collection of remediation and recovery technologies like those predicated on photocatalytic-, electric-, chemical-, membrane-, and adsorptive-based processes currently exists in different stages of development or deployment between these methods of water management. Among these technologies, solid sorbent processes embody an optimal balance between cost-effectiveness, environmental friendliness, and technological maturity. The U.S. Department of Energy’s National Energy Technology Laboratory developed a suit of cross-linked, functionalized silica sorbents tailored to eliminate the most toxic metals regulated by the U.S. Environmental Protection Agency (EPA); critical metals identified by the U.S. Geological Survey (USGS); and harmful organics like the infamous perfluoroalkyl and polyfluoroalkyl substances (PFAS). An array of laboratory and field tests proved that the MUST sorbents removed ppb-level lead from drinking water, selenium from FGD wastewater below EPA limits, aqueous dyes and PFAS; and fractionated low ppm-level critical metals (CM) from AMD and simulated produced water. Proof-of-concept for commercial CM recovery was verified through obtaining milligram-quantities of purified Al solids from a sorbent multi-bed AMD field-site test. Commercial efficacy was further supported by achieving purified fractions of adsorbed Mn upon treating both the AMD and synthetic produced water with the laboratory multi-bed test unit.

Wilfong, Walter C.↗

Hydrogen Detection Strategies to Support H2@SCALE - The NREL Sensor Laboratory

Hydrogen represents a major pathway to decarbonize and stabilize the national and international energy industry and select manufacturing markets. To facilitate the development of hydrogen markets, the US Department of Energy initiated H2@Scale to bring together stakeholders to advance affordable hydrogen production, transport, storage, and utilization to increase revenue opportunities in multiple energy sectors. One major impediment to hydrogen implementation is cost. To expedite the use of hydrogen in energy and other markets, the United States announced in 2021 the Hydrogen Shot, which seeks to reduce the cost of clean hydrogen by 80% to $1 per 1 kilogram in 1 decade ("1 1 1"). As the cost of hydrogen drops, new applications will emerge that will require unique configurations of existing equipment and infrastructure, and eventually lead to advances in the generation and utilization of hydrogen. As the hydrogen economy expands, sensors and detection methods will need to adapt to changing infrastructure demands to address the primary targets of health & safety, emissions monitoring, and process control. The NREL Sensor Laboratory is playing a pivotal role in advancing the use of hydrogen sensors and detection methodologies in each of these categories to support DOE's mission for safe and efficient utilization in emerging markets. Health & safety monitors are required to ensure that operators and facilities can react to unintended hydrogen releases, either as GH2, LH2, or as a constituent of blends (e.g., natural gas or ammonia). Current detection methodologies focus on safety applications to detect near its lower flammable limit (4 vol %), and typically include point sensors in applications such as fixed or mobile detectors (e.g., personal gas monitors). Methodologies amenable for area detection include acoustic, emerging optical imaging methods, and flame detectors. Comparable detection strategies can be utilized for emissions monitoring and quantization, however few methods can simultaneously cover both low (emissions) and high (health & safety) levels. Deployment of emission level detectors will be required to 1) reduce product loss through small but potentially significant leaks from an environmental or cost perspective, 2) reduce downtime of high demand systems by early identification of eminent system failures (leaks through pump or compressor seals indicative of impending failure), and 3) address potential emission monitoring requirements that may be set by regulating bodies. The first two points should be adopted by industry to reduce the cost-of-goods-sold. The third main category for hydrogen detection relates to process control and may be advantageous for many existing applications. Two main applications are emerging. For example, the purity requirements for hydrogen that is dispensed from refueling systems for hydrogen fuel cell electric vehicles (FCEV) is rigorously regulated by the Standard SAE J2719, which prescribes maximum allowable levels of multiple impurities in the hydrogen fuel and must be verified by a regulatory body. Hydrogen contaminant detectors (HCD) integrated to the fueling station can assure this compliance. HCDs must be able operate in 100% H2 backgrounds and be able to distinguish between multiple contaminants at low ppm to low ppb levels. Secondly, as a strategy to decarbonize the natural gas grid, there are proposals to blend hydrogen with natural gas. This blending will affect transport applications (pipeline infrastructure), stationary combustion systems (turbines), and consumer and commercial appliances. In the short-term, hydrogen levels up to 20% are proposed. Variations in the hydrogen level can have dramatic impact on the combustion process and on the potential response of safety sensors. These mixtures may be regulated so that the concentration at a delivery point must be monitored with high precision. However, routine maintenance may introduce background gases such as ambient air (with water) or maintenance gases (introduced with welding processes or adhesive outgassing.) Therefore, the detection methodology must be robust enough to recover or respond to various contaminants. Several reviews can be found in literature addressing sensing and detection technologies, including their limitations and applications. However, for most applications, limitations can be alleviated by combining various detection techniques either through system integration or implementation of machine learning methods (artificial intelligence). In this presentation, we will discuss several applications, highlight their current approach for hydrogen detection, and suggest detection strategies to supplement their limitations.

ENERGY STORAGE,HYDROGEN↗

Anomalous Spin Precession Frequency Analysis in the Muon $g-2$ Experiment at Fermilab

The Muon $g-2$ experiment at Fermilab aims to measure the muon anomalous magnetic moment with an unprecedented precision of 140 parts per billion (ppb). Data collection concluded in June 2023, and analysis of the largest dataset (2021-2023) is underway. Previous publications based on data from 2018-2020 established the experimental foundation. This document provides an overview of the measurement of the muon anomalous spin precession frequency ($\omega_a$) and the associated systematic corrections. The precision of these results directly tests the Standard Model's completeness, making the experiment a cornerstone in the field of particle physics.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗

Simulations, Modeling and Data Analysis of Parity Violating Electron Scattering Experiments

In the Standard Model (SM) of nuclear and particle physics, parity violation is incorporated through the representation of the weak interaction as a chiral gauge interaction. Only the left-handed components of particles and right-handed components of antiparticles participate in weak interactions in the Standard Model. This implies that parity is asymmetric for the weak interaction. Parity violating electron scattering (PVES) experiments are designed to probe the physics parameters related to the SM, with the possibility to discover physics beyond the SM (BSM) by measuring the parity violating asymmetry ¿¿¿ of longitudinally polarized electrons scattered off unpolarized targets with high precision. This dissertation will be focused on two PVES experiments, the next 208Pb Lead Radius Experiment (PREX-II), and the Measurement of a Lepton-Lepton Electroweak Reaction (MOLLER) experiment, as well as in some small sections, the Calcium Radius Experiment (CREX) and P2 experiment which are also PVES experiments). PREX-II and CREX experiments, performed in Hall A at the Thomas Jefferson National Accelerator Facility (Jefferson Lab), measured ¿¿¿ in the elastic scattering of longitudinally polarized electrons from 208Pb and 48Ca targets to provide a precise model independent determination of the neutron skin thickness of 208Pb and 48Ca nuclei, respectively. The MOLLER experiment, proposed to start in 2027 and also to be performed in Hall A at Jefferson Lab, is to measure ¿¿¿ of longitudinally polarized electrons scattered off unpolarized electrons (Møller scattering) to determine the weak charge of electrons ¿¿¿ and the weak mixing angle ¿¿ with high precision. As for the P2 experiment, which will be performed at the upcoming MESA accelerator in Mainz Germany, it is to measure the weak charge of proton ¿¿¿ using ¿¿¿ in the elastic electron-proton scattering of polarized electrons off unpolarized protons. The final results from the PREX-II experiment are presented as ¿¿¿=550±16 (¿¿¿¿)±8 (¿¿¿¿) parts-per-billion (ppb). Combining the PREX-I and PREX-II results, the neutron skin thickness from PREX experiments is determined as ¿¿-¿¿=0.283±0.071 ¿¿ in 208Pb. This thesis lists the software and computational contribution of the author to these PVES experiments, including writing scripts and software to help with the PREX-II/CREX experiments, analyzing data to provide useful information and systematic uncertainty for the PREX-II experiment, modeling and simulations for the MOLLER, and providing an alternative design of an electronic equipment for the P2 experiment.

Chen, Yufan↗