Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “POSITIONING”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Video-Based Sensor for Robotic Position and Attitude determination

NASA's Marshall Space Flight Center (MSFC) has, for the last ten years, developed various video-based sensors for use in automated docking systems. The latest generation of sensor will operate at rates of up to 100 Hz, determining the relative position (X, Y, and Z) and attitude (Roll, Pitch, and Yaw) between the sensor and a small 3-dimensional target, making it suitable for applications in robotic sensing. The Advanced Video Guidance Sensor (AVGS) is designed to track multiple targets at different ranges and determine the position and attitude of each one. The previous generation of video sensor, the Video Guidance Sensor (VGS), was flown twice on the Space Shuttle to test its performance on orbit. One of the tests performed was determining the relative positions and attitudes between the VGS and its target, which was moved to various positions using the Remote Manipulator System (RMS). The RMS position data and VGS measured data were analyzed after the flights, with good correlation between the position and attitude data of the two data sets. The test using the RMS gives a good idea of the ability of the use of the AVGS as a sensor for end-effector position and attitude determination.

Howard, Richard T.↗

Regional ventilation-perfusion distribution is more uniform in the prone position

The arterial blood PO(2) is increased in the prone position in animals and humans because of an improvement in ventilation (VA) and perfusion (Q) matching. However, the mechanism of improved VA/Q is unknown. This experiment measured regional VA/Q heterogeneity and the correlation between VA and Q in supine and prone positions in pigs. Eight ketamine-diazepam-anesthetized, mechanically ventilated pigs were studied in supine and prone positions in random order. Regional VA and Q were measured using fluorescent-labeled aerosols and radioactive-labeled microspheres, respectively. The lungs were dried at total lung capacity and cubed into 603-967 small ( approximately 1.7-cm(3)) pieces. In the prone position the homogeneity of the ventilation distribution increased (P = 0.030) and the correlation between VA and Q increased (correlation coefficient = 0.72 +/- 0.08 and 0.82 +/- 0.06 in supine and prone positions, respectively, P = 0.03). The homogeneity of the VA/Q distribution increased in the prone position (P = 0.028). We conclude that the improvement in VA/Q matching in the prone position is secondary to increased homogeneity of the VA distribution and increased correlation of regional VA and Q.

NASA Program Biomedical Research and Countermeasur↗

Rapid Centroids and the Refined Position Accuracy of the Swift Gamma-ray Burst Catalogue

The Swift X-ray Telescope autonomously refines the Burst Alert Telescope positions (approx.1-4' uncertainty) to better than 5 arcsec, within 5 seconds of target acquisition by the observatory for typical bursts. The results of the rapid positioning capability of the XRT are presented here for both known sources and newly discovered GRBs, demonstrating the ability to automatically utilize one of two integration times according to the burst brightness, and to correct the position for alignment offsets caused by the fast pointing performance and variable thermal environment of the satellite as measured by the Telescope Alignment Monitor. We present an evaluation of the position accuracy for both the onboard centroiding software and the ground software for the calibration targets and show that a significant improvement in position accuracy is obtained if the boresight detector position is optimized relative to the spacecraft pointing. Finally, we present an updated catalogue of Swift GRB X-ray positions obtained in Photon Counting Mode using the improved, calibrated boresight.

Hill, J. E.↗

Automatic Mesh Generation of Hybrid Mesh on Valves in Multiple Positions in Feedline Systems

Fluid flow simulations through a valve often require evaluation of the valve in multiple opening positions. A mesh has to be generated for the valve for each position and compounding. The problem is the fact that the valve is typically part of a larger feedline system. In this paper, we propose to develop a system to create meshes for feedline systems with parametrically controlled valve openings. Herein we outline two approaches to generate the meshes for a valve in a feedline system at multiple positions. There are two issues that must be addressed. The first is the creation of the mesh on the valve for multiple positions. The second is the generation of the mesh for the total feedline system including the valve. For generation of the mesh on the valve, we will describe the use of topology matching and mesh generation parameter transfer. For generation of the total feedline system, we will describe two solutions that we have implemented. In both cases the valve is treated as a component in the feedline system. In the first method the geometry of the valve in the feedline system is replaced with a valve at a different opening position. Geometry is created to connect the valve to the feedline system. Then topology for the valve is created and the portion of the topology for the valve is topology matched to the standard valve in a different position. The mesh generation parameters are transferred and then the volume mesh for the whole feedline system is generated. The second method enables the user to generate the volume mesh on the valve in multiple open positions external to the feedline system, to insert it into the volume mesh of the feedline system, and to reduce the amount of computer time required for mesh generation because only two small volume meshes connecting the valve to the feedline mesh need to be updated.

Ross, Douglass H.↗

Inductive Non-Contact Position Sensor

Optical hardware has been developed to measure the depth of defects in the Space Shuttle Orbiter's windows. In this hardware, a mirror is translated such that its position corresponds to the defect's depth, so the depth measurement problem is transferred to a mirror-position measurement problem. This is preferable because the mirror is internal to the optical system and thus accessible. Based on requirements supplied by the window inspectors, the depth of the defects needs to be measured over a range of 200 microns with a resolution of about 100 nm and an accuracy of about 400 nm. These same requirements then apply to measuring the position of the mirror, and in addition, since this is a scanning system, a response time of about 10 ms is needed. A market search was conducted and no sensor that met these requirements that also fit into the available housing volume (less than one cubic inch) was found, so a novel sensor configuration was constructed to meet the requirements. This new sensor generates a nearly linearly varying magnetic field over a small region of space, which can easily be sampled, resulting in a voltage proportional to position. Experiments were done with a range of inductor values, drive voltages, drive frequencies, and inductor shapes. A rough mathematical model was developed for the device that, in most aspects, describes how it operates and what electrical parameters should be chosen for best performance. The final configuration met all the requirements, yielding a small rugged sensor that was easy to use and had nanometer resolution over more than the 200-micron range required. The inductive position sensor is a compact device (potentially as small as 2 cubic centimeters), which offers nanometer-position resolution over a demonstrated range of nearly 1 mm. One of its advantages is the simplicity of its electrical design. Also, the sensor resolution is nearly uniform across its operational range, which is in contrast to eddy current and capacitive sensors whose sensitivity is dependent upon position.

Youngquist, Robert↗

Absolute Position of Targets Measured Through a Chamber Window Using Lidar Metrology Systems

Lidar is a useful tool for taking metrology measurements without the need for physical contact with the parts under test. Lidar instruments are aimed at a target using azimuth and elevation stages, then focus a beam of coherent, frequency modulated laser energy onto the target, such as the surface of a mechanical structure. Energy from the reflected beam is mixed with an optical reference signal that travels in a fiber path internal to the instrument, and the range to the target is calculated based on the difference in the frequency of the returned and reference signals. In cases when the parts are in extreme environments, additional steps need to be taken to separate the operator and lidar from that environment. A model has been developed that accurately reduces the lidar data to an absolute position and accounts for the three media in the testbed air, fused silica, and vacuum but the approach can be adapted for any environment or material. The accuracy of laser metrology measurements depends upon knowing the parameters of the media through which the measurement beam travels. Under normal conditions, this means knowledge of the temperature, pressure, and humidity of the air in the measurement volume. In the past, chamber windows have been used to separate the measuring device from the extreme environment within the chamber and still permit optical measurement, but, so far, only relative changes have been diagnosed. The ability to make accurate measurements through a window presents a challenge as there are a number of factors to consider. In the case of the lidar, the window will increase the time-of-flight of the laser beam causing a ranging error, and refract the direction of the beam causing angular positioning errors. In addition, differences in pressure, temperature, and humidity on each side of the window will cause slight atmospheric index changes and induce deformation and a refractive index gradient within the window. Also, since the window is a dispersive media, the effect of both phase and group indices have to be considered. Taking all these factors into account, a method was developed to measure targets through multiple regions of different materials and produce results that are absolute measurements of target position in three-dimensional space, rather than simply relative position. The environment in which the lidar measurements are taken must be broken down into separate regions of interest and each region solved for separately. In this case, there were three regions of interest: air, fused silica, and vacuum. The angular position of the target inside the chamber is solved using only phase index and phase velocity, while the ranging effects due to travel from air to glass to vacuum/air are solved with group index and group velocity. When all parameters are solved simultaneously, an absolute knowledge of the position of each target within an environmental chamber can be derived. Novel features of this innovation include measuring absolute position of targets through multiple dispersive and non-dispersive media, deconstruction of lidar raw data from a commercial off-the-shelf unit into reworkable parameters, and use of group velocities to reduce range data. Measurement of structures within a vacuum chamber or other harsh environment, such as a furnace, may now be measured as easily as if they were in an ambient laboratory. This analysis permits transformation of the raw data into absolute spatial units (e.g., mm). This technique has also been extended to laser tracker, theodolite, and cathetometer measurements through refractive media.

Kubalak, David↗

Southeast Greenland Winter Precipitation Strongly Linked to the Icelandic Low Position

Greenland's largest precipitation flux occurs in its southeast (SE) region during the winter, controlled primarily by easterly winds and frequent cyclogenesis in the North Atlantic. Several studies have attempted to link SE Greenland precipitation to the North Atlantic Oscillation (NAO) but results are inconsistent. This work uses reanalysis, automatic weather station data, and regional climate model output to show that the east-west position of the Icelandic low is a better predictor of SE Greenland precipitation (average correlation of r equals -0.48 in DJF (December January February)) than climate indices such as the NAO (r equals -0.06 in DJF). In years when the Icelandic low is positioned extremely west, moisture transport increases up to approximately 40 percent (or up to 40 kilograms per meter per second) off the SE Greenland coast compared to when the low is in an extreme east position. Furthermore, in years when the Icelandic low is positioned extremely west, storm track density and intensity increase just off the SE coast of Greenland. Thus, the Icelandic low's longitudinal position dominates SE Greenland ice sheet's wintertime precipitation, a positive term in the ice sheet mass balance. Given SE Greenland's importance in the overall ice sheet mass balance, the position of the Icelandic low is therefore important for making projections of future sea level.

Arctic↗

A317_Fast and Thermal Neutron Spectrum Dosimetry Measurements in the Advanced Test Reactor large-B and small-I Positions Following the Sixth Core Internals Change-out

The Advanced Test Reactor (ATR) has a wide variety of irradiation positions that have had experiments that were developed by users from around the world. Most experiment irradiations rely on thoroughly benchmarked numerical models. However, some irradiation positions in ATR are not as well- characterized and are complicated by spectral perturbations from control cylinder orientation. The “small I” and “large-B” irradiation positions are located nearby control cylinders and suffer from these flux perturbations from control cylinder orientations that change during an irradiation cycle to maintain the desired core power distribution. Models predicted that these types of position would exhibit both spectral shifts and amplitude changes in neutron flux, but few measurements have been conducted to benchmark these predictions. Recently, requalification testing was performed to confirm the operational readiness of the ATR following the completion of the Core Internals Change-out (CIC). These tests provided a unique opportunity to validate the analytical methods used to simulate the ATR because nearly all components in the reactor were in a clean as-built state, significantly reducing modelling uncertainties. One subset of the testing included characterization of the fast and thermal neutron flux in the “small-I” and “large-B” positions using silver, cobalt, and nickel neutron dosimetry. In contrast to typical irradiation cycles, the control cylinders were held in position during the post-CIC nuclear testing. The specific activity of these dosimeter wires was measured following two low-power tests with different control cylinder positions.

21 - SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLAN↗

Demonstration of sub-micron UCN position resolution using room-temperature CMOS sensor

High spatial resolution of ultracold neutron (UCN) measurement is of growing interest to UCN experiments such as UCN spectrometers, UCN polarimeters, quantum physics of UCNs, and quantum gravity. Here we utilize physics informed deep learning to enhance the experimental position resolution and to demonstrate sub-micron spatial resolutions for UCN position measurements obtained using a room-temperature CMOS sensor, extending our previous work that demonstrated a position uncertainty of 1.5 microns. We explore the use of the open-source software Allpix Squared to generate experiment-like synthetic hit images with ground-truth position labels. We use physics-informed deep learning by training a fully connected neural network (FCNN) to learn a mapping from input hit images to output hit position. The automated analysis for sub-micron position resolution in UCN detection combined with the fast data rates of current and next generation UCN sources will enable improved precision for future UCN research and applications.

10B nanometer thin film↗

SU-E-T-563: A Fast and Quantative Picket-Fence Test of a Submillimeter Patient Positioning System for Stereotactic Radiosurgery

Purpose: Picket-fence test is a qualitative TG142-recommended quality assurance (QA) test for multileaf collimators. In study, we adopted the same concept and developed a fast but quantatitive QA test for an automatic patient positioning system that requires submilleter accuracy for a radiosurgical treatment. Methods: A piece of radiochromic film was first placed inside a spherical solid water phantom and then irradiated with a sequenence of linearly placed shots of same collimator size (e.g. 4-mm) via the Leskell Gamma Knife Perfexion system (PFX). The shots were positioned with either equal or non-equal gaps of approximately 4 mm to 8 mm depending on the location of the region of interest. A pattern recognization program was developed and then applied to measure the gap spacing between two adjacent shots. The measured distance was then compared with the initial preset values for the test. Results: By introducing variable systematic and random shifts of 0.1 mm to 0.5 mm to the shot sequence, the maximum gap variation from the described test was found to be 0.35 mm or less. On average the positioning uncertainty for the PFX delivery system was found to be 0.1±0.2 mm. No significant difference in the positioning uncertainty was noted for the centrally aligned shot sequence locations versus the peripherally aligned shot sequence locations. Conclusion: A new quantitative picket-fence type test was developed and demonstrated for routine QA of the submillimeter PFX patient positioning sytem. This test also enables independent verification of any patient-specific shot positioning for a critical treatment such as a tumor in brainstem. Dr Ma is currently on the board of international society of stereotactic Radiosurgery.

60 APPLIED LIFE SCIENCES↗

SU-F-T-24: Impact of Source Position and Dose Distribution Due to Curvature of HDR Transfer Tubes

Purpose: Brachytherapy is a highly targeted from of radiotherapy. While this may lead to ideal dose distributions on the treatment planning system, a small error in source location can lead to change in the dose distribution. The purpose of this study is to quantify the impact on source position error due to curvature of the transfer tubes and the impact this may have on the dose distribution. Methods: Since the source travels along the midline of the tube, an estimate of the positioning error for various angles of curvature was determined using geometric properties of the tube. Based on the range of values a specific shift was chosen to alter the treatment plans for a number of cervical cancer patients who had undergone HDR brachytherapy boost using tandem and ovoids. Impact of dose to target and organs at risk were determined and checked against guidelines outlined by radiation oncologist. Results: The estimate of the positioning error was 2mm short of the expected position (the curved tube can only cause the source to not reach as far as with a flat tube). Quantitative impact on the dose distribution is still in the process of being analyzed. Conclusion: The accepted positioning tolerance for the source position of a HDR brachytherapy unit is plus or minus 1mm. If there is an additional 2mm discrepancy due to tube curvature, this can result in a source being 1mm to 3mm short of the expected location. While we do always attempt to keep the tubes straight, in some cases such as with tandem and ovoids, the tandem connector does not extend as far out from the patient so the ovoid tubes always contain some degree of curvature. The dose impact of this may be significant.

60 APPLIED LIFE SCIENCES↗

SU-G-JeP3-14: Positioning and Dosimetric Uncertainties in Image-Guided Radiation Therapy with Respiratory Gating

Purpose: To investigate quantitatively positioning and dosimetric uncertainties due to 4D-CT intra-phase motion in the internal-target-volume (ITV) associated with radiation therapy using respiratory-gating for patients setup with image-guidance-radiation-therapy (IGRT) using free-breathing or average-phase CT-images. Methods: A lung phantom with an embedded tissue-equivalent target is imaged with CT while it is stationary and moving. Four-sets of structures are outlined: (a) the actual target on CT-images of the stationary-target, (b) ITV on CT-images for the free-moving phantom, (c) ITV’s from the ten different phases (10–100%) and (d) ITV on the CT-images generated from combining 3 phases: 40%–50%–60%. The variations in volume, length and center-position of the ITV’s and their effects on dosimetry during dose delivery for patients setup with image-guidance are investigated. Results: Intra-phase motion due to breathing affects the volume, center position and length of the ITVs from different respiratory-phases. The ITV’s vary by about 10% from one phase to another. The largest ITV is measured on the free breathing CT images and the smallest is on the stationary CT-images. The ITV lengths vary by about 4mm where it may shrink or elongated depending on the motion-phase. The center position of the ITV varies between the different motion-phases which shifts upto 10mm from the stationary-position which is nearly equal to motion-amplitude. This causes systematic shifts during dose delivery with beam gating using certain phases (40%–50%–60%) for patients setup with IGRT using free-breathing or average-phase CT-images. The dose coverage of the ITV depends on the margins used for treatment-planning-volume where margins larger than the motion-amplitudes are needed to ensure dose coverage of the ITV. Conclusion: Volume, length, and center position of the ITV’s change between the different motion phases. Large systematic shifts are induced by respiratory-gating with ITVs on certain phases when patients are setup with IGRT using free-breathing or average-phase CT-images.

60 APPLIED LIFE SCIENCES↗

Precise Kinematic Positioning with Simultaneous GPS Pseudorange and Carrier Phase Measurements

This paper investigates three precise kinematic positioning techniques with simultaneous GPS pseudorange and carrier phase measurements. These techniques are simple, efficient, and well suited for real-time positioning applications. A simulation/covariance analysis is carried out comparing the relative performance of these techniques. The analysis indicates that GPS carrier phase measurements significantly strengthen kinematic positioning. When wide-area differential GPS for reducing SA clock errors and GPS ephemeris errors is available, a low Earth orbiting satellite can be positioned to 0.5-0.8 m in accuracy (3-D RSS). The accuracy is superior to positioning with pseudorange measurements alone by a factor of 2 to 3. Relative positioning performance and complexity between the three techniques are compared.

['Kinematic↗

Lunar Surface Position Determination using Perceived Signal Strength

The purpose of this project is to evaluate the feasibility of transmitters and receivers on the lunar surface for Position Determination (PD) without any form of lunar Global Positioning System (GPS). The early Artemis program may lack GPS satellites orbiting the Moon, and it is critical that activities with the lander, rover, and crew EVA identify their position on the lunar surface at all times. This project creates a prototype system that trilaterates user position based upon the perceived signal from at least 3 nearby transmission towers, called “Lunar Access Points”. The application of perceived signal strength for surface PD has historically been used in terrestrial systems such as Long Range Navigation (LORAN), which was popular with the maritime industry prior to the Global Positioning System (GPS). The ease of installing such a local system for early Artemis missions provides a critical resource until satellite-based position determination systems are deployed. A surface-based PD can also be used in GPS-denied environments such as deep craters or lava tubes where satellite visibility is compromised. By demonstrating the basic capability of surface PD, this student team has learned about issues with power, distance, thermal, dust, radiation, data processing, and communication problems applicable to the lunar surface. This knowledge can feed into future NASA requirements to improve the capability of a LunaNET implementation for the Artemis program. This project follows 10 years of successful collaboration between NASA JSC/ARES, Texas Space, Technology, Applications and Research (T STAR) and Texas A&M University in a Public, Private, Academic (PPA) Partnership. NASA funds T STAR to mentor undergraduate Capstone teams in the College of Engineering Department to design, built, and test prototypes meeting NASA requirements. TAMU faculty lead the student teams in their academic class, and NASA Subject Matter Experts (SMEs) provide T STAR and students insight on requirements evolution, prior design projects, and future development goals.

Position Determination↗

Positive amplitudes in the amplituhedron

The all-loop integrand for scattering amplitudes in planar N=4 SYM is determined by an “amplitude form” with logarithmic singularities on the boundary of the amplituhedron. In this note we provide strong evidence for a new striking property of the superamplitude, which we conjecture to be true to all loop orders: the amplitude form is positive when evaluated inside the amplituhedron. The statement is sensibly formulated thanks to the natural “bosonization” of the superamplitude associated with the amplituhedron geometry. However this positivity is not manifest in any of the current approaches to scattering amplitudes, and in particular not in the cellulations of the amplituhedron related to on-shell diagrams and the positive grassmannian. The surprising positivity of the form suggests the existence of a “dual amplituhedron” formulation where this feature would be made obvious. We also suggest that the positivity is associated with an extended picture of amplituhedron geometry, with the amplituhedron sitting inside a co-dimension one surface separating “legal” and “illegal” local singularities of the amplitude. In conclusion, we illustrate this in several simple examples, obtaining new expressions for amplitudes not associated with any triangulations, but following in a more invariant manner from a global view of the positive geometry.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

False positive PSMA PET for tumor remnants in the irradiated prostate and other interpretation pitfalls in a prospective multi-center trial

Readers need to be informed about potential pitfalls of [ 68 Ga]Ga-PSMA-11 PET interpretation. Here we report [ 68 Ga]Ga-PSMA-11 PET findings discordant with the histopathology/composite reference standard in a recently published prospective trial on 635 patients with biochemically recurrent prostate cancer. Consensus reads were false positive in 20 regions of 17/217 (8%) patients with lesion validation. Majority of the false positive interpretations (13 of 20, 65%) occurred in the context of suspected prostate (bed) relapse (T) after radiotherapy ( n = 11); other false positive findings were noted for prostate bed post prostatectomy (T, n = 2), pelvic nodes (N, n = 2), or extra pelvic lesions (M, n = 5). Major sources of false positive findings were PSMA-expressing residual adenocarcinoma with marked post-radiotherapy treatment effect. False negative interpretation occurred in 8 regions of 6/79 (8%) patients with histopathology validation, including prostate (bed) ( n = 5), pelvic nodes ( n = 1), and extra pelvic lesions ( n = 2). Lesions were missed mostly due to small metastases or adjacent bladder/urine uptake.[ 68 Ga]Ga-PSMA-11 PET at biochemical recurrence resulted in less than 10% false positive interpretations. Post-radiotherapy prostate uptake was a major source of [ 68 Ga]Ga-PSMA-11 PET false positivity. In few cases, PET correctly detects residual PSMA expression post-radiotherapy, originating however from treated, benign tissue or potentially indolent tumor remnants.

Radiology, Nuclear Medicine & Medical Imaging↗

Influence of Lymphatic Invasion on Locoregional Recurrence Following Mastectomy: Indication for Postmastectomy Radiotherapy for Breast Cancer Patients With One to Three Positive Nodes

Purpose: The indication for postmastectomy radiotherapy (PMRT) in breast cancer patients with one to three positive lymph nodes has been in discussion. The purpose of this study was to identify patient groups for whom PMRT may be indicated, focusing on varied locoregional recurrence rates depending on lymphatic invasion (ly) status. Methods and Materials: Retrospective analysis of 1,994 node-positive patients who had undergone mastectomy without postoperative radiotherapy between January 1990 and December 2000 at our hospital was performed. Patient groups for whom PMRT should be indicated were assessed using statistical tests based on the relationship between locoregional recurrence rate and ly status. Results: Multivariate analysis showed that the ly status affected the locoregional recurrence rate to as great a degree as the number of positive lymph nodes (p < 0.001). Especially for patients with one to three positive nodes, extensive ly was a more significant factor than stage T3 in the TNM staging system for locoregional recurrence (p < 0.001 vs. p = 0.295). Conclusion: Among postmastectomy patients with one to three positive lymph nodes, patients with extensive ly seem to require local therapy regimens similar to those used for patients with four or more positive nodes and also seem to require consideration of the use of PMRT.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Interfractional Position Variation of Pancreatic Tumors Quantified Using Intratumoral Fiducial Markers and Daily Cone Beam Computed Tomography

Purpose: The aim of this study was to quantify interfractional pancreatic position variation using fiducial markers visible on daily cone beam computed tomography (CBCT) scans. In addition, we analyzed possible migration of the markers to investigate their suitability for tumor localization. Methods and Materials: For 13 pancreatic cancer patients with implanted Visicoil markers, CBCT scans were obtained before 17 to 25 fractions (300 CBCTs in total). Image registration with the reference CT was used to determine the displacement of the 2 to 3 markers relative to bony anatomy and to each other. We analyzed the distance between marker pairs as a function of time to identify marker registration error (SD of linear fit residuals) and possible marker migration. For each patient, we determined the mean displacement of markers relative to the reference CT (systematic position error) and the spread in displacements (random position error). From this, we calculated the group systematic error, Σ, and group random error, σ. Results: Marker pair distances showed slight trends with time (range, −0.14 to 0.14 mm/day), possibly due to tissue deformation, but no shifts that would indicate marker migration. The mean SD of the fit residuals was 0.8 mm. We found large interfractional position variations, with for 116 of 300 (39%) fractions a 3-dimensional vector displacement of >10 mm. The spread in displacement varied significantly (P<.01) between patients, from a vector range of 9.1 mm to one of 24.6 mm. For the patient group, Σ was 3.8, 6.6, and 3.5 mm; and σ was 3.6, 4.7 and 2.5 mm, in left–right, superior–inferior, and anterior–posterior directions, respectively. Conclusions: We found large systematic displacements of the fiducial markers relative to bony anatomy, in addition to wide distributions of displacement. These results for interfractional position variation confirm the potential benefit of using fiducial markers rather than bony anatomy for daily online position verification for pancreatic cancer patients.

62 RADIOLOGY AND NUCLEAR MEDICINE↗