Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PMT”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Compact LaBr{sub 3}: Ce Gamma Ray Detector with Si-APD Readout

BrilLanCe 380 (LaBr{sub 3}:Ce) crystal scintillators available from Saint-Gobain Crystals have achieved 2.6% FWHM for 662 keV photons. This is accomplished with PMT light sensors. Attempts to have similarly good results with PIN photo-diodes and APDs have not been successful. PIN photodiodes do not have any gain and the signal to noise ratio is poor at room temperature. Similarly, even though APDs have sufficient gain, they have poor signal to noise at room temperature. Recently there have been improvements in APDs decreasing the internal noise and increasing their sensitivity, making them an excellent light sensor. With the improved APD, it is now possible to achieve performance with a solid state light sensor comparable to that of PMTs. We have measured 2.8% for 662 keV gamma rays at room temperature using an APD for a light sensor on a 20 mm long crystal of 1.6 cc volume. APDs have advantages of compactness, inherent ruggedness and minimal sensitivity to magnetic fields. Such a device is very practical for hand held and portable field measurement applications. (Performance reported in SGC literature.)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Detection of the Crab Pulsar above 25 GeV with the MAGIC Telescope

The 17 m diameter Cherenkov telescope MAGIC, located on the Canary Island of La Palma, has the lowest trigger threshold among operating Cherenkov telescopes; this makes it a very promising tool for the detection of the pulsed gamma-ray ({gamma}-ray) emission from ground. Recently, a new analog summation trigger concept, which allows reducing the threshold even further, has been designed and implemented. The analog signals of patches in the camera, comprising 18 pixels each, are summed up in the analog mode. In order to prevent triggers from photomultiplier (PMT) afterpulses, the individual pixel signals are clipped at a preset amplitude level and then added up. The average FWHM of the time duration of signals induced by cosmic rays is 2.6 ns. This allows one to keep the coincidence time window very small and thus to strongly suppress accidental triggers. In the usual digital trigger designs, the signal should be above a certain threshold from each individual pixel to contribute to the trigger. In the summation trigger all low amplitude signals in a given patch in the camera are summed up and fully contribute to the trigger.The new trigger concept provides a low cost trigger for Cherenkov telescopes and it is very effective and stable. This trigger system for the MAGIC telescope was installed in October 2007 and was successfully used in the detection of the Crab Pulsar above 25 GeV.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Time Resolution of Fast Photomultipliers for Time of Flight PET

Time resolution study of 1 inch Photonis XP1020 photomultiplier is reported. The number of photoelectrons, time jitter and time resolution with 4x4x20 mm{sup 3} LSO crystal were measured. All the mentioned PMT properties were measured at five positions on the photocathode.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Study of GSO scintillator for the LHCf upgrade

The GSO scintillator has a very excellent radiation resistance, fast decay time and large amounts of light yield. Because of these features, GSO will be used to upgrade the current LHCf detector. We examined the features of GSO by using heavy ion beam at Heavy Ion Medical Accelerator in Chiba (HIMAC) Japan. The linearity of PMT R7400 for the large light yield of GSO with a {sup 132}Xe beam and the radiation hardness with a {sup 12}C beam were measured. As a result, GSO scintillator showed a good linearity up to the signal corresponding to 6 TeV EM-shower maximum in the LHCf detector, and a good radiation hardness up to 7x10{sup 5} Gy. For the LHCf Arm1 detector, small scaled GSO crystals (GSO bars), have been fabricated for the position determination detector. 5 GSO bars have been manufactured and its performance have been evaluated using {sup 12}C beam. Its light yield and position dependency have been evaluated.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Phoswich scintillator for proton and gamma radiation of high energy

We present here a Phoswich scintillator design to achieve both high resolution gamma ray detection, and good efficiency for high energy protons. There are recent developments of new high resolution scintillator materials. Especially the LaBr3(Ce) and LaCl3(Ce) crystals have very good energy resolution in the order of 3% for 662 keV gamma radiation. In addition, these materials exhibit a very good light output (63 and 32 photons/keV respectively).A demonstrator detector in the form of an Al cylinder of 24 mm diameter and a total length of 80 mm with 2 mm wall thickness, containing a LaBr3(Ce) crystal of 20 mm diameter and 30 mm length directly coupled to a LaCl3(Ce) crystal of 50 mm length, and closed with a glass window of 5 mm, was delivered by Saint Gobain. To the glass window a Hamamatsu R5380 Photomultiplier tube (PMT) was coupled using silicon optical grease.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Tomographic imaging system for measuring impurity line emission in a field-reversed configuration

A 16 chord optical tomography system has been developed and implemented in the flux coil generated-field reversed configuration (FRC). The chords are arranged in two fans of eight, which cover {approx}35% of the vessel area at the midplane. Each illuminate separate photomultiplier tubes (PMTs) which are fitted with narrow band-pass filters. In this case, filters are centered at 434.8 nm to measure emission from singly ionized argon. PMT crosstalk is negligible. Background noise due to electron radiation and H{sub {gamma}} line radiation is <10% of argon emission. The spatial resolution of the reconstruction is 1.5 cm. Argon is introduced using a puff valve and tube designed to impart the gas into the system as the FRC is forming. Reconstruction of experimental data results in time-dependent, 2D emissivity profiles of the impurity ions. Analysis of these data show radial, cross-field diffusion to be in the range of 10-10{sup 3} m{sup 2}/s during FRC equilibrium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Assessment and Mitigation of Diagnostic-Generated Electromagnetic Interference at the National Ignition Facility

Electromagnetic interference (EMI) is an ever-present challenge at laser facilities such as the National Ignition Facility (NIF). The major source of EMI at such facilities is laser-target interaction that can generate intense electromagnetic fields within, and outside of, the laser target chamber. In addition, the diagnostics themselves can be a source of EMI, even interfering with themselves. In this paper we describe EMI generated by ARIANE and DIXI, present measurements, and discuss effects of the diagnostic-generated EMI on ARIANE's CCD and on a PMT nearby DIXI. Finally we present some of the efforts we have made to mitigate the effects of diagnostic-generated EMI on NIF diagnostics.

42 ENGINEERING↗

Development of diagnostic and manipulation systems for space-charge dominated electron beams and confined electron plasmas in ELTRAP

Modifications have been implemented in the Penning-Malmberg device ELTRAP aimed at performing studies on the dynamics of space-charge dominated nanosecond electron bunches traveling along the magnetic field. In particular, a Thomson backscattering apparatus has been developed where an infrared (IR) laser pulse collides with the bunched electron beam. The frequency-shifted backscattered radiation, acquired by means of a photomultiplier (PMT), can be exploited to evaluate information on energy, energy spread and density of the bunch. The achievable sensitivity of the diagnostics has been estimated, and valuable information on the main parameters affecting the signal-to-noise (S/N) ratio has been obtained [B. Paroli, F. Cavaliere, M. Cavenago, F. De Luca, M. Ikram, G. Maero, C. Marini, R. Pozzoli, and M. Rome, JINST 7, P01008 (2012)]. A series of upgrades are under way, aimed at increasing the S/N ratio through the use of a new laser for the electron source, the insertion of a stray light shield, and the optimization of the detection electronics. Moreover, electromagnetic simulations relevant to the design and implementation of a microwave heating system are presented. The generation of an electron plasma in ELTRAP by means of a low-power radio frequency (RF) drive in the MHz range applied on one of the trap electrodes and under ultra-high vacuum (UHV) conditions has previously been demonstrated [B. Paroli, F. De Luca, G. Maero, F. Pozzoli, and M. Rome, Plasma Sources Sci. Technol. 19, 045013 (2010)]. The new heating system will allow the extension of the RF studies to the GHz range and in particular the production of a more energetic electron plasma via cyclotron resonant excitation.

43 PARTICLE ACCELERATORS↗

GIOVE, a shallow laboratory Ge-spectrometer with 100 μBq/kg sensitivity

A new germanium gamma spectrometer called GIOVE (Germanium spectrometer with Inner and Outer Veto) has been set up at the underground/shallow laboratory (15 m w.e.) of MPI-K. Its double plastic scintillator veto system and neutron moderation interlayer lower the background by more than one order of magnitude compared to the other existing spectrometer at this facility. The integral (40-2700 keV) background rate of about 290 counts (day kg){sup −1} is just a factor 4 to 8 above that of the GeMPI spectrometers operated at LNGS (3800 m w.e.) and thus proves that even under shallow overburden sub mBq/kg sensitivities are achievable. Extended material screening and neutron attenuation studies preceded the final design of the spectrometer. The technical realization of the spectrometer is described in detail with special emphasis on the inner veto system. For its optimisation a simulation model was developed for light collection on small low activity PMT’s under various geometrical conditions. Radon suppression is accomplished by employing a gas tight sample container and a nitrogen flushed glove-box system with an airlock. The active volume of the crystal was modelled by absorption scanning measurements and Monte Carlo simulations. The complete shield is implemented in a Geant4 based simulation framework.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low background high efficiency radiocesium detection system based on positron emission tomography technology

After the 2011 nuclear power plant accident at Fukushima, radiocesium contamination in food became a serious concern in Japan. However, low background and high efficiency radiocesium detectors are expensive and huge, including semiconductor germanium detectors. To solve this problem, we developed a radiocesium detector by employing positron emission tomography (PET) technology. Because {sup 134}Cs emits two gamma photons (795 and 605 keV) within 5 ps, they can selectively be measured with coincidence. Such major environmental gamma photons as {sup 40}K (1.46 MeV) are single photon emitters and a coincidence measurement reduces the detection limit of radiocesium detectors. We arranged eight sets of Bi{sub 4}Ge{sub 3}O{sub 12} (BGO) scintillation detectors in double rings (four for each ring) and measured the coincidence between these detectors using PET data acquisition system. A 50 × 50 × 30 mm BGO was optically coupled to a 2 in. square photomultiplier tube (PMT). By measuring the coincidence, we eliminated most single gamma photons from the energy distribution and only detected those from {sup 134}Cs at an average efficiency of 12%. The minimum detectable concentration of the system for the 100 s acquisition time is less than half of the food monitor requirements in Japan (25 Bq/kg). These results show that the developed radiocesium detector based on PET technology is promising to detect low level radiocesium.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nonlinear luminescence response of CaF{sub 2}:Eu and YAlO{sub 3}:Ce to single-ion excitation

Understanding scintillation physics and nonproportionality is essential to accelerate materials discovery that has been restricted due to the difficulties inherent to large crystal growth and complex nature of gamma-solid interaction. Taking advantage of less restrictive growth and deposition techniques for smaller crystal sizes or thin films and better fundamental understanding of ion-solid interactions, a unique ion approach is demonstrated to effectively screen candidate scintillators with relatively small size and evaluate their nonlinear scintillation response. Response of CaF{sub 2}:Eu and YAlO{sub 3}:Ce scintillators to single ions of H{sup +}, He{sup +}, and O{sup 3+} are measured by the corresponding pulse height over a continuous energy range using a time-of-flight–scintillator–photoelectric multiplier tube apparatus. Nonlinear response of the scintillators under ionizing ion irradiation is quantitatively evaluated by considering the energy partitioning process. In a differential energy deposition region with negligible displacement damage, the low, medium and high excitation energy deposition density (D{sub exci}) can be produced by energetic H{sup +}, He{sup +} and O{sup 3+} ions, respectively, and significantly different impacts on the response characteristics of these two benchmark scintillators are observed. For CaF{sub 2}:Eu, the scintillation efficiency under ion irradiation monotonically decreases with increasing excitation-energy density. In contrast, the response efficiency of YAlO{sub 3}:Ce scintillation initially increases with excitation-energy density at low excitation-energy densities, goes through a maximum, and then decreases with further increasing excitation-energy density. The fundamental mechanism causing these different response behaviours in the scintillators is based on the competition between the scintillation response and the nonradiative quenching process under different excitation densities, which is also the main origin of the nonlinear response of the scintillators to irradiation.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Lowering the threshold in the DAMA dark matter detector

We look at two improvements related to the DAMA/LIBRA dark matter detector. We show how using a more optimized binning scheme of the current data can lead to significantly tighter contraints on the compatible regions of the WIMP parameter space. In addition, the PMT’s of the detector were upgraded in 2010, allowing the low energy threshold to be lowered from 2 keVee to 1 keVee. We examine the implications for the dark matter interpretion of the DAMA modulation with data in this new energy region. Specifically, we focus on how well the degeneracy between the low mass and high mass regions can be removed by this new data. We find that the lower threshold data should rule out one of the two mass ranges in the spin-independent case at a minimum of the 2.6σ level in the worst case scenario.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Monte Carlo simulation of the data acquisition chain of scintillation detectors

The good performance of a detector can be strongly affected by the instrumentation used to acquire the data. The possibility of anticipating how the acquisition chain will affect the signal can help in finding the best solution among different set-ups. In this work we developed a Monte Carlo code that aims to simulate the effect of the various components of a digital Data Acquisition system (DAQ) applied to scintillation detectors. The components included in the model are: the scintillator, the photomultiplier tube (PMT), the signal cable and the digitizer. We benchmarked the code against real data acquired with a NE213 scintillator, comparing simulated and real signal pulses induced by gamma-ray interaction. Then we studied the dependence of the energy resolution of a pulse height spectrum (PHS) on the sampling frequency and the bit resolution of the digitizer. We found that exceeding some values of the sampling frequency and the bit resolution improves only marginally the performance of the system. The method can be applied for the study of various detector systems relevant for nuclear techniques, such as in fusion diagnostics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

1 ns time to digital converters for the KM3NeT data readout system

The KM3NeT collaboration aims at the construction of a multi-km3 high-energy neutrino telescope in the Mediterranean Sea consisting of thousands of glass spheres (nodes), each of them containing 31 photomultiplier (PMT) of small photocathode area. The readout and data acquisition system of KM3NeT has to collect, treat and send to shore, in an economic way, the enormous amount of data produced by the photomultipliers. For this purpose, 31 high-resolution time-interval measuring channels are implemented on the Field-Programmable Gate Arrays (FPGA) based on Time to Digital Converter (TDC). TDC are very common devices in particles physics experiments. Architectures with low resources occupancy are desirable allowing the implementation of other instrumentation, communication and synchronization systems on the same device. The required resolution to measure both, time of flight and timestamp must be 1 ns. A 4-Oversampling technique with two high frequency clocks is used to achieve this resolution. The proposed TDC firmware is developed using very few resources in Xilinx Kintex-7.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

The electronics readout and data acquisition system of the KM3NeT neutrino telescope node

The KM3NeT neutrino telescope will be composed by tens of thousands of glass spheres, called Digital Optical Module (DOM), each of them containing 31 PMTs of small photocathode area (3'). The readout and data acquisition system of KM3NeT have to collect, treat and send to shore, in an economic way, the enormous amount of data produced by the photomultipliers and at the same time to provide time synchronization between each DOM at the level of 1 ns. It is described in the present article the Central Logic Board, that integrates the Time to Digital Converters and the White Rabbit protocol used for the DOM synchronization in a transparent way, the Power Board used in the DOM, the PMT base to readout the photomultipliers and the respective collecting boards, the so called Octopus Board.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of the ETEL and HZC 3-inch PMTs for the KM3NeT project

The KM3NeT collaboration constructs a multi-cubic-kilometer scale neutrino telescope in the Mediterranean Sea. The telescope’s detection units, deployed in the deep sea, will be instrumented with facet like Digital Optical Modules (DOMs), each housing 31 three-inch photomultiplier tubes (PMTs) and readout electronics inside of 17-inch pressure resistant glass sphere. Two companies, ET Enterprises Ltd (ETEL) from UK and HZC from China developed new 3-inch PMTs to meet KM3NeT requirements. 126 PMTs of types D783KFLA, D792KFLA, and D793KFLA from ETEL and 7 PMTs of type XP53 from HZC have been delivered to KM3NeT and tested by the KM3NeT groups of NIKHEF-Amsterdam and ECAP-Erlangen. Tests have been performed to measure the main PMT parameters listed in the KM3NeT specifications, such as gain, transit time spread, dark rate, fraction of spurious pulses, and quantum efficiency. Methods and results are presented in this report.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Surface purity control during XMASS detector refurbishment

The XMASS project aims at detecting dark matter, pp and {sup 7}Be solar neutrinos, and neutrino less double beta decay using large volume of pure liquid xenon. The first physics target of the XMASS project is to detect dark matter with 835 kg liquid xenon. After the commissioning runs, XMASS detector was refurbished to minimize the background contribution mainly from PMT sealing material and we restarted data taking in November 2013. We report how we control surface purity, especially how we prevent radon daughter accumulation on the detector copper surface, during XMASS detector refurbishment. The result and future plan of XMASS are also reported.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Multi-channel programmable power supply with temperature compensation for silicon sensors

Silicon Photo-Multipliers (SiPMs) are increasingly becoming popular for discrete photon counting applications due to the wealth of advantages they offer over conventional photo-detectors such as photo-multiplier tubes and hybrid photo-diodes. SiPMs are used in variety of applications ranging from high energy physics and nuclear physics experiments to medical diagnostics. The gain of a SiPM is directly proportional to the difference between applied and breakdown voltage of the device. However, the breakdown voltage depends critically on the ambient temperature and has a large temperature co-efficient in the range of 40-60 mV/°C resulting in a typical gain variation of 3%-5%/°C [Dinu et al., in IEEE Nuclear Science Symposium, Medical Imaging Conference and 17th Room Temperature Semiconductor Detector Workshop (IEEE, 2010), p. 215]. We plan to use the SiPM as a replacement for PMT in the cosmic ray experiment (GRAPES-3) at Ooty [Gupta et al., Nucl. Instrum. Methods Phys. Res., Sect. A 540, 311 (2005)]. There the SiPMs will be operated in an outdoor environment subjected to temperature variation of about 15 °C over a day. A gain variation of more than 50% was observed for such large variations in the temperature. To stabilize the gain of the SiPM under such operating conditions, a low-cost, multi-channel programmable power supply (0-90 V) was designed that simultaneously provides the bias voltage to 16 SiPMs. The programmable power supply (PPS) was designed to automatically adjust the operating voltage for each channel with a built-in closed loop temperature feedback mechanism. The PPS provides bias voltage with a precision of 6 mV and measures the load current with a precision of 1 nA. Using this PPS, a gain stability of 0.5% for SiPM (Hamamatsu, S10931-050P) has been demonstrated over a wide temperature range of 15 °C. The design methodology of the PPS system, its validation, and the results of the tests carried out on the SiPM is presented in this article. The proposed design also has the capability of gain stabilization of devices with non-linear thermal response.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗