Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “PET”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

PET - A proton/electron telescope for studies of magnetospheric, solar, and galactic particles

The Proton/Electron Telescope (PET) on SAMPEX is designed to provide measurements of energetic electrons and light nuclei from solar, galactic, and magnetospheric sources. PET is an all solid-state system that will measure the differential energy spectra of electrons from about 1 to about 30 MeV and H and He nuclei from about 20 to about 300 MeV/nuc, with isotope resolution of H and He extending from about 20 to about 80 MeV/nuc. As SAMPEX scans all local times and geomagnetic cutoffs over the course of its near-polar orbit, PET will characterize precipitating relativistic electron events during periods of declining solar activity, and it will examine whether the production rate of odd nitrogen and hydrogen molecules in the middle atmosphere by precipitating electrons is sufficient to affect O3 depletion. In addition, PET will complement studies of the elemental and isotopic composition of energetic heavy (Z greater than 2) nuclei on SAMPEX by providing measurements of H, He, and electrons. Finally, PET has limited capability to identify energetic positrons from potential natural and man-made sources.

Cook, Walter R.↗

Integrated X-Ray Reflectivity Measurements for Elliptically Curved PET Crystals

Spectroscopy provides valuable information about the temperature and density of a compressed pellet in a plasma. Elliptically curved pentaerythritol (PET) crystals are used as components for spectrometers. Their elliptical geometry gives several advantages related to spectral energy range, source focus, and spectral image compression.[1] The crystal curvature increases the spectrometer throughput but at the cost of a loss in resolution. Four different crystals are used in a spectrometer at the National Ignition Facility (NIF) target chamber at Lawrence Livermore National Laboratory (LLNL). Figure 1 shows the arrangement of the elliptical PET crystals in the snout of a NIF target diagnostic shown in Figure 2. The spectrum from the crystals is captured by four image plates located behind the crystals. A typical mandrel, the darkened section, upon which the PET crystal is glued, is shown in Figure 3, which also shows the complete ellipse. There are four elliptical segment types, each having the same major axis but a different minor axis. The crystals are 150 mm long in the diffraction direction and 25.4 mm high. Two crystals of each type were calibrated. The throughput for each spectrometer is determined by the integrated reflectivity of the PET crystal.[1] The goal of this effort was to measure the reflectivity curve of the PET curved crystal at several energies and determine the integrated reflectivity and the curve width as a function of the X-ray spectral energy and location on the ellipse where the beam strikes.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of Tumor Volumes as Determined by Pathologic Examination and FDG-PET/CT Images of Non-Small-Cell Lung Cancer: A Pilot Study

Purpose: To determine the cut-off standardized uptake value (SUV) on {sup 18}F fluoro-2-deoxy-glucose (FDG) positron emission tomography/computed tomography (FDG-PET/CT) images that generates the best volumetric match to pathologic gross tumor volume (GTV{sub path}) for non-small-cell lung cancer (NSCLC). Methods and Materials: Fifteen patients with NSCLC who underwent FDG-PET/CT scans followed by lobectomy were enrolled. The surgical specimen was dissected into 5-7-mum sections at approximately 4-mm intervals and stained with hematoxylin and eosin. The tumor-containing area was outlined slice by slice and the GTV{sub path} determined by summing over all the slices, taking into account the interslice thickness and fixation-induced volume reduction. The gross tumor volume from the PET images, GTV{sub PET}, was determined as a function of cut-off SUV. The optimal threshold or optimal absolute SUV was defined as the value at which the GTV{sub PET} was the same as the GTV{sub path}. Results: The fixation process induced a volumetric reduction to 82% +- 10% (range, 62-100%) of the original. The maximal SUV was 10.1 +- 3.6 (range, 4.2-18.7). The optimal threshold and absolute SUV were 31% +- 11% and 3.0 +- 1.6, respectively. The optimal threshold was inversely correlated with GTV{sub path} and tumor diameter (p < 0.05), but the optimal absolute SUV had no significant correlation with GTV{sub path} or tumor diameter (p > 0.05). Conclusion: This study evaluated the use of GTV{sub path} as a criterion for determining the optimal cut-off SUV for NSCLC target volume delineation. Confirmatory studies including more cases are being performed.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Production and radiochemistry of the in vivo PET generator 140 Nd/ 140 Pr as an imaging surrogate for F-block therapeutic radionuclides

Theranostics, a combined approach of diagnostics and therapeutics, often employs F-block therapeutic radionuclides including 225 Ac, 177 Lu, and 161 Tb. While there is a lack of F-block PET imaging radionuclides, the in vivo PET generator pair 140 Nd/ 140 Pr can act as a theranostic imaging counterpart to the F-block therapeutic radionuclides. In this study, we explored the production and separation of high purity 140 Nd via the 141 Pr(p,2n) 140 Nd reaction route. Monoisotopic 141 Pr targets irradiated with 20 MeV protons for 10 min with 10 µA beam current yielded 21.45 ± 0.82 MBq (580 ± 22 µCi) of 140 Nd. A two-step separation method was developed for the purification of 140 Nd from the 141 Pr target material. Recoveries of 27.4 ± 2.1% 140Nd were obtained upon separation with < 20 ppb of 141 Pr target material in the final product. Radiolabeling of Macropa and DOTA chelators with 140 Nd resulted in [ 140 Nd]Nd-Macropa with a molar activity of 74.0 MBq/µmol (2.0 mCi/µmol) and [ 140 Nd]Nd-DOTA with a molar activity of 70.3 MBq/µmol (1.9 mCi/µmol). An imaging study with a phantom indicated the PET spatial resolution of 140 Nd/ 140 Pr was distinguishable down to 2.4 mm. This study sets the stage for the 140 Nd/ 140 Pr in vivo PET generator to be explored in radiopharmaceutical applications.

F-block↗

Closed‐Loop Recyclable Vitrimer Plastics from PET Waste: A Design for Circularity

Plastics are essential to modern society, but their low recycling rates and inefficient end-of-life management pose a significant environmental challenge. Herein, the efficient strategy for upcycling postconsumer poly(ethylene terephthalate) (PET) waste into robust, closed-loop recyclable vitrimer plastics and composites is presented to address this issue. The catalyst-free aminolysis utilizes readily available amines to deconstruct diverse PET wastes into macromonomers, which are upcycled into vitrimers, exhibiting superior mechanical properties and exceeding the ultimate tensile stress and Young's Modulus of virgin PET by 80% and 150% respectively. These vitrimers exhibit excellent healability, shape memory, thermal reprocessability, and closed-loop chemical recyclability, enabling quantitative macromonomer recovery even from mixed plastic waste streams and glass/carbon fiber reinforced vitrimer (G/CFRV) composites. Furthermore, the vitrimer resin yields robust GFRV and CFRV composites with tensile strengths exceeding those of traditional epoxy composites by 100% and 80%, respectively, while maintaining complete chemical recyclability of both constituent materials. A preliminary technoeconomic analysis confirms the costeffectiveness and competitiveness of the facile PET deconstruction approach, which is potentially adaptable to other condensation polymers. Further, this study presents a facile approach to upcycling plastic waste into circular plastics and composites, offering a sustainable solution to global plastic waste management and fostering a circular economy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

PET-RAFT polymerization under flow chemistry and surface-initiated reactions

Recently, photoinduced electron/energy transfer reversible addition–fragmentation chain transfer (PET-RAFT) polymerization has been developed and gaining wide acceptance. PET-RAFT polymerization uses visible light to initiate the reaction and is compatible with ambient conditions and green solvents. It also maintains the ability to produce well-defined polymers and possesses high potential as an alternative to the conventional RAFT technique. Here, this review aims to summarize the fundamentals of PET-RAFT polymerization, highlight two of the most commonly studied applications of PET-RAFT process (i.e. flow chemistry and surface-initiated polymerization), and explore perspectives and new possibilities of the technique.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Optimizing quantification of MK6240 tau PET in unimpaired older adults

Accurate measurement of Alzheimer's disease (AD) pathology in older adults without significant clinical impairment is critical to assessing intervention strategies aimed at slowing AD-related cognitive decline. The U.S. Study to Protect Brain Health Through Lifestyle Intervention to Reduce Risk (POINTER) is a 2-year randomized controlled trial to evaluate the effect of multicomponent risk reduction strategies in older adults (60-79 years) who are cognitively unimpaired but at increased risk for cognitive decline/dementia due to factors such as cardiovascular disease and family history. The POINTER Imaging ancillary study is collecting tau-PET ([ 18 F]MK6240), beta-amyloid (Aβ)-PET ([ 18 F]florbetaben [FBB]) and MRI data to evaluate neuroimaging biomarkers of AD and cerebrovascular pathophysiology in this at-risk sample. Here 481 participants (70.0±5.0; 66% F) with baseline MK6240, FBB and structural MRI scans were included. PET scans were coregistered to the structural MRI which was used to create FreeSurfer-defined reference regions and target regions of interest (ROIs). We also created off-target signal (OTS) ROIs to examine the magnitude and distribution of MK6240 OTS across the brain as well as relationships between OTS and age, sex, and race. OTS was unimodally distributed, highly correlated across OTS ROIs and related to younger age and sex but not race. Aiming to identify an optimal processing approach for MK6240 that would reduce the influence of OTS, we compared our previously validated MRI-guided standard PET processing and 6 alternative approaches. The alternate approaches included combinations of reference region erosion and meningeal OTS masking before spatial smoothing as well as partial volume correction. To compare processing approaches we examined relationships between target ROIs (entorhinal cortex (ERC), hippocampus or a temporal meta-ROI (MetaROI)) SUVR and age, sex, race, Aβ and a general cognitive status measure, the Modified Telephone Interview for Cognitive Status (TICSm). Overall, the processing approaches performed similarly, and none showed a meaningful improvement over standard processing. Across processing approaches we observed previously reported relationships with MK6240 target ROIs including positive associations with age, an Aβ+> Aβ- effect and negative associations with cognition. In sum, we demonstrated that different methods for minimizing effects of OTS, which is highly correlated across the brain within subject, produced no substantive change in our performance metrics. This is likely because OTS contaminates both reference and target regions and this contamination largely cancels out in SUVR data. Caution should be used when efforts to reduce OTS focus on target or reference regions in isolation as this may exacerbate OTS contamination in SUVR data.

60 APPLIED LIFE SCIENCES↗

A high-affinity [ 18 F]-labeled phosphoramidate peptidomimetic PSMA-targeted inhibitor for PET imaging of prostate cancer

Here in this study, a structurally modified phosphoramidate scaffold, with improved prostate-specific membrane antigen (PSMA) avidity, stability and in vivo characteristics, as a PET imaging agent for prostate cancer (PCa), was prepared and evaluated. p-Fluorobenzoyl-aminohexanoate and 2-(3-hydroxypropyl)glycine were introduced into the PSMA-targeting scaffold yielding phosphoramidate 5. X-ray crystallography was performed on the PSMA/5 complex. [ 18 F]5 was synthesized, and cell uptake and internalization studies were conducted in PSMA(+) LNCaP and CWR22Rv1 cells and PSMA(-) PC-3 cells. In vivo PET imaging and biodistribution studies were performed at 1 and 4 h post injection in mice bearing CWR22Rv1 tumor, with or without blocking agent. The crystallographic data showed interaction of the p-fluorobenzoyl group with an arene-binding cleft on the PSMA surface. In vitro studies revealed elevated uptake of [ 18 F]5 in PSMA(+) cells (2.2% in CWR22Rv1 and 12.1% in LNCaP) compared to PSMA(-) cells (0.08%) at 4 h. In vivo tumor uptake of 2.33% ID/g and tumor-to-blood ratio of 265:1 was observed at 4 h. In conclusion, we have successfully synthesized, radiolabeled and evaluated a new PSMA-targeted PET agent. The crystal structure of the PSMA/5 complex highlighted the interactions within the arene-binding cleft contributing to the overall complex stability. The high target uptake and rapid non-target clearance exhibited by [ 18 F]5 in PSMA(+) xenografts substantiates its potential use for PET imaging of PCa.

59 BASIC BIOLOGICAL SCIENCES↗

A Radiofluorinated Divalent Cystine Knot Peptide for Tumor PET Imaging

A divalent knottin containing two separate integrin binding epitopes (RGD) in the adjacent loops, 3-4A, was recently developed and reported in our previous publication. In the current study, 3-4A was radiofluorinated with a 4-nitrophenyl 2- 18 F-fluoropropinate ( 18 F-NFP) group and the resulting divalent positron emission tomography (PET) probe, 18 F-FP–3-4A, was evaluated as a novel imaging probe to detect integrin αvβ3 positive tumors in living animals. Knottin 3-4A was synthesized by solid phase peptide synthesis, folded, and site-specifically conjugated with 18/19 F-NFP to produce the fluorinated peptide 18/19 F-fluoropropinate-3-4A ( 18/19 F-FP–3-4A). The stability of 18 F-FP–3-4A was tested in both phosphate buffered saline (PBS) buffer and mouse serum. Cell uptake assays of the radiolabeled peptides were performed using U87MG cells. In addition, small animal PET imaging and biodistribution studies of 18 F-FP–3-4A were performed in U87MG tumor-bearing mice. The receptor targeting specificity of the radiolabeled peptide was also verified by coinjecting the probe with a blocking peptide cyclo(RGDyK). Our study showed that 18 F-FP–3-4A exhibited excellent stability in PBS buffer (pH 7.4) and mouse serum. Small animal PET imaging and biodistribution data revealed that 18 F-FP–3-4A exhibited rapid and good tumor uptake (3.76 ± 0.59% ID/g and 2.22 ± 0.62% ID/g at 0.5 and 1 h, respectively). 18F-FP–3-4A was rapidly cleared from the normal tissues, resulting in excellent tumor-to-normal tissue contrasts. For example, liver uptake was only 0.39 ± 0.07% ID/g and the tumor to liver ratio was 5.69 at 1 h p.i. Furthermore, coinjection of cyclo(RGDyK) with 18 F-FP–3-4A significantly inhibited tumor uptake (0.41 ± 0.12 vs 1.02 ± 0.19% ID/g at 2.5 h) in U87MG xenograft models, demonstrating specific accumulation of the probe in the tumor. In summary, the divalent probe 18 F-FP–3-4A is characterized by rapid and high tumor uptake and excellent tumor-to-normal tissue ratios. 18 F-FP–3-4A is a highly promising knottin based PET probe for translating into clinical imaging of tumor angiogenesis.

18F↗

[ 18 F](2 S ,4 R )4-Fluoroglutamine PET Detects Glutamine Pool Size Changes in Triple-Negative Breast Cancer in Response to Glutaminase Inhibition

Glutaminolysis is a metabolic pathway adapted by many aggressive cancers, including triple-negative breast cancers (TNBC), to utilize glutamine for survival and growth. In this study, we examined the utility of [ 18 F](2S,4R)4-fluoroglutamine ([ 18 F]4F-Gln) PET to measure tumor cellular glutamine pool size, whose change might reveal the pharmacodynamic (PD) effect of drugs targeting this cancer-specific metabolic pathway. High glutaminase (GLS) activity in TNBC tumors resulted in low cellular glutamine pool size assayed via high-resolution 1 H magnetic resonance spectroscopy (MRS). GLS inhibition significantly increased glutamine pool size in TNBC tumors. MCF-7 tumors, with inherently low GLS activity compared to TNBC, displayed a larger baseline glutamine pool size that did not change as much in response to GLS inhibition. The tumor-to-blood-activity-ratios (T/B) obtained from [ 18 F]4F-Gln PET images matched the distinct glutamine pool sizes of both tumor models at baseline. After a short course of GLS inhibitor treatment, the T/B values increased significantly in TNBC, but did not change in MCF-7 tumors. Across both tumor types and after GLS inhibitor or vehicle treatment, we observed a strong positive correlation between T/B values and tumor glutamine pool size measured using MRS ( r 2 =0.71). In conclusion, [ 18 F]4F-Gln PET tracked cellular glutamine pool size in breast cancers with differential GLS activity and detected increases in cellular glutamine pool size induced by GLS inhibitors. This work accomplished the first necessary step towards validating [ 18 F]4F-Gln PET as a PD marker for glutaminase-targeting drugs.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

First PET Imaging Studies With 63 Zn-Zinc Citrate in Healthy Human Participants and Patients With Alzheimer Disease

Abnormalities in zinc homeostasis are indicated in many human diseases, including Alzheimer disease (AD). 63 Zn-zinc citrate was developed as a positron emission tomography (PET) imaging probe of zinc transport and used in a first-in-human study in 6 healthy elderly individuals and 6 patients with clinically confirmed AD. A dynamic PET imaging of the brain was performed for 30 minutes following intravenous administration of 63 Zn-zinc citrate (~330 MBq). Subsequently, body PET images were acquired. Urine and venous blood were analyzed to give information on urinary excretion and pharmacokinetics. Regional cerebral 63 Zn clearances were compared with 11 C-Pittsburgh Compound B ( 11 C-PiB) and 18 F-fluorodeoxyglucose ( 18 F-FDG) imaging data. 63 Zn-zinc citrate was well tolerated in human participants with no adverse events monitored. Tissues of highest uptake were liver, pancreas, and kidney, with moderate uptake being seen in intestines, prostate (in males), thyroid, spleen, stomach, pituitary, and salivary glands. Moderate brain uptake was observed, and regional dependencies were observed in 63 Zn clearance kinetics in relationship with regions of high amyloid-β plaque burden ( 11 C-PiB) and 18 F-FDG hypometabolism. In conclusion, zinc transport was successfully imaged in human participants using the PET probe 63 Zn-zinc citrate. Primary sites of uptake in the digestive system accent the role of zinc in gastrointestinal function. Preliminary information on zinc kinetics in patients with AD evidenced regional differences in clearance rates in correspondence with regional amyloid-β pathology, warranting further imaging studies of zinc homeostasis in patients with AD.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

A Multi-Streamline Approach for Upcycling PET into a Biodiesel and Asphalt Modifier

The non-degradable nature of petroleum-based plastics and the dependence on petroleum-based products in daily life and production are dilemmas of human development today. We hereby developed a plastic waste upcycling process to address these challenges. A multi-stream fraction strategy was developed to process poly (ethylene terephthalate) (PET) plastics into soluble and insoluble fractions. The soluble fraction was used as a sole carbon source for microbial fermentation to produce biodiesel precursor lipids with an appreciable bioconversion yield. The insoluble fraction containing fractionated polymers was used as the asphalt binder modifiers. The downsized PET additive improved the high-temperature performance of the asphalt binder by 1 performance grade (PG) without decreasing the low-temperature PG. Subsequent SEM imaging unveiled alterations in the micromorphology induced by PET incorporation. Further FTIR and 1 H NMR analysis highlighted the aromatic groups of PET polymers as a crucial factor influencing performance enhancement. The results demonstrated the multi-stream fraction as a promising approach for repurposing plastic waste to produce biodiesel and modify asphalt. Finally, this approach holds the potential to tackle challenges in fuel supply and enhance infrastructure resilience to global warming.

09 BIOMASS FUELS↗

Recycling of PET by Dissolution-Purification-Recovery (DPR) Process Using Bioderived Solvent

Polyethylene terephthalate (PET) waste continues to accumulate at staggering rates, with the majority still routed to landfills due to limitations in current recycling methods. While mechanical recycling is widely implemented, it struggles to effectively remove colorants, additives, and harmful contaminants - resulting in discolored, degraded materials with limited reuse potential. In this presentation, we demonstrate a scalable dissolution-purification-recovery (DPR) process designed to selectively reclaim high-purity PET from post-consumer bottle flake. The method utilizes a food grade bio-based solvent for targeted PET dissolution, followed by activated carbon treatment for impurity removal and antisolvent-induced precipitation for polymer recovery. The resulting recycled PET exhibits complete decolorization, significantly reduced metal contamination, and minimal loss in molecular weight. These performance metrics indicate strong suitability for remanufacturing into new bottles, offering a circular alternative to traditional mechanical recycling pathways.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantitative PET Imaging Using A Comprehensive Monte Carlo System Model

We present the complete image generation methodology developed for the RatCAP PET scanner, which can be extended to other PET systems for which a Monte Carlo-based system model is feasible. The miniature RatCAP presents a unique set of advantages as well as challenges for image processing, and a combination of conventional methods and novel ideas developed specifically for this tomograph have been implemented. The crux of our approach is a low-noise Monte Carlo-generated probability matrix with integrated corrections for all physical effects that impact PET image quality. The generation and optimization of this matrix are discussed in detail, along with the estimation of correction factors and their incorporation into the reconstruction framework. Phantom studies and Monte Carlo simulations are used to evaluate the reconstruction as well as individual corrections for random coincidences, photon scatter, attenuation, and detector efficiency variations in terms of bias and noise. Finally, a realistic rat brain phantom study reconstructed using this methodology is shown to recover >; 90% of the contrast for hot as well as cold regions. The goal has been to realize the potential of quantitative neuroreceptor imaging with the RatCAP.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Dihydroxyterephthalate—A Trojan Horse PET Counit for Facile Chemical Recycling

Abstract Here, low‐energy poly(ethylene terephthalate) (PET) chemical recycling in water: PET copolymers with diethyl 2,5‐dihydroxyterephthalate (DHTE) undergo selective hydrolysis at DHTE sites, autocatalyzed by neighboring group participation, is demonstrated. Liberated oligomeric subchains further hydrolyze until only small molecules remain. Poly(ethylene terephthalate‐ stat ‐2,5‐dihydroxyterephthalate) copolymers were synthesized via melt polycondensation and then hydrolyzed in 150–200 °C water with 0–1 wt% ZnCl 2 , or alternatively in simulated sea water. Degradation progress follows pseudo‐first order kinetics. With increasing DHTE loading, the rate constant increases monotonically while the thermal activation barrier decreases. The depolymerization products are ethylene glycol, terephthalic acid, 2,5‐dihydroxyterephthalic acid, and bis(2‐hydroxyethyl) terephthalate dimer, which could be used to regenerate virgin polymer. Composition‐optimized copolymers show a decrease of nearly 50% in the Arrhenius activation energy, suggesting a 6‐order reduction in depolymerization time under ambient conditions compared to that of PET homopolymer. This study provides new insight to the design of polymers for end‐of‐life while maintaining key properties like service temperature and mechanical properties. Moreover, this chemical recycling procedure is more environmentally friendly compared to traditional approaches since water is the only needed material, which is green, sustainable, and cheap.

36 MATERIALS SCIENCE↗

Hopes Beyond PET Recycling: Environmentally Clean and Engineeringly Applicable

Disposal of plastics in the environment has become a core of anxiety in developing countries, while in the developed countries the focus has additionally been placed on design and manufacture of emerging products from plastic wastes—a somewhat vague yet promising horizon. Central to environmental concerns are poly(ethylene terephthalate) (PET) wastes, mainly from post-consumer bottles. Because of a considerable drop in molecular weight in the course of recycling, recycled PETs are not suitable for engineering uses. An efficient yet reasonably green synthesis route is employed here to convert PET wastes into polyurethane, and then carbon nanotubes (CNTs) was added at different levels to obtain nanocomposites with high mechanical properties. The effects of isocyanate (NCO)/hydroxyl (OH) molar ratio and CNTs content on the morphology, physical and mechanical properties were discussed. Chemical/physical crosslink density was calculated from initial slope of stress–strain curves, Mooney–Rivlin plots, strain-hardening modulus, rubbery-plateau storage modulus and swelling data. High tensile strength (300 MPa) and breaking elongation (160%) of polyurethane/CNTs nanocomposites born from PET wastes seemed promising. Microscopic analyses by AFM, SEM, and TEM gave useful information about distribution of CNTs in polyurethane. Lastly, structural changes were correlated to mechanical properties improvement.

36 MATERIALS SCIENCE↗

Rubidium-82 PET imaging is feasible in a rat myocardial infarction model

Background: Small-animal myocardial infarct models are frequently used in the assessment of new cardioprotective strategies. A validated quantification of perfusion using a non-cyclotron-dependent PET tracer would be of importance in monitoring response to therapy. We tested whether myocardial PET perfusion imaging is feasible with Rubidium-82 ({sup 82}Rb) in a small-animal scanner using a rat myocardial infarct model. Methods: 18 Sprague-Dawley rats underwent permanent coronary artery ligation (infarct group), and 11 rats underwent ischemia-reperfusion (reperfusion group) procedure. {sup 82}Rb-PET and magnetic resonance imaging (MRI) were conducted before and after the intervention. Perfusion was compared to both left ventricle ejection fraction (LVEF) and infarct size assessed by MRI. Results: Follow-up global {sup 82}Rb-uptake correlated significantly with infarct size (infarct group: r = −0.81, P < 0.001 and reperfusion group: r = −0.61, P = 0.04). Only {sup 82}Rb-uptake in the infarct group correlated with LVEF. At follow-up, a higher segmental {sup 82}Rb-uptake in the infarct group was associated with better wall motion (β = 0.034, CI [0.028;0.039], P < 0.001, R{sup 2} = 0.30), and inversely associated with scar transmurality (β = −2.4 [−2.6; −2.2], P < 0.001, R{sup 2} = 0.59). The associations were similar for the reperfusion group. Conclusion: {sup 82}Rb-PET is feasible in small animal scanners despite the long positron range and enables fast and time-efficient myocardial perfusion imaging in rat models.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Longitudinal monitoring adipose-derived stem cell survival by PET imaging hexadecyl-4-{sup 124}I-iodobenzoate in rat myocardial infarction model

Highlights: • We developed a safe, simple and appropriate stem cell labeling method with {sup 124}I-HIB. • ADSC survival can be monitored with PET in MI model via direct labeling. • Tracking of ADSC labeled with {sup 124}I-HIB was possible for 3 days in MI model using PET. • ADSC viability and differentiation were not affected by {sup 124}I-HIB labeling. • Survival of ADSC in living bodies can be longitudinally tracked with PET imaging. - Abstract: This study aims to monitor how the change of cell survival of transplanted adipose-derived stem cells (ADSCs) responds to myocardial infarction (MI) via the hexadecyl-4-{sup 124}I-iodobenzoate ({sup 124}I-HIB) mediated direct labeling method in vivo. Stem cells have shown the potential to improve cardiac function after MI. However, monitoring of the fate of transplanted stem cells at target sites is still unclear. Rat ADSCs were labeled with {sup 124}I-HIB, and radiolabeled ADSCs were transplanted into the myocardium of normal and MI model. In the group of {sup 124}I-HIB-labeled ADSC transplantation, in vivo imaging was performed using small-animal positron emission tomography (PET)/computed tomography (CT) for 9 days. Twenty-one days post-transplantation, histopathological analysis and apoptosis assay were performed. ADSC viability and differentiation were not affected by {sup 124}I-HIB labeling. In vivo tracking of the {sup 124}I-HIB-labeled ADSCs was possible for 9 and 3 days in normal and MI model, respectively. Apoptosis of transplanted cells increased in the MI model compared than that in normal model. We developed a direct labeling agent, {sup 124}I-HIB, and first tried to longitudinally monitor transplanted stem cell to MI. This approach may provide new insights on the roles of stem cell monitoring in living bodies for stem cell therapy from pre-clinical studies to clinical trials.

60 APPLIED LIFE SCIENCES↗