Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Optical Detector”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

A New Plasma Radar Concept for Simultaneous Magnetic and Density Measurements

An innovative, compact 288GHz interferometer has been fabricated, tested, installed and successfully demonstrated on the LAPD-U magnetized plasma at UCLA. The system takes advantage of frequency modulated (FM) radar techniques to deliver a compact heterodyne system. In addition, the reflected power from the source is taken advantage of to eliminate the need for additional quasi-optical components. Electron density in LAPD-U plasma has recently been increased substantially thereby requiring a higher frequency/shorter wavelength interferometer to avoid deleterious refractive effects. This system satisfies those needs. The system uses a 96GHz varactor tuned Gunn oscillator which passes to a passive tripler. This tripler has ~3% conversion efficiency. The 288GHz radiation is then coupled to free space using a so-called dual-mode or Pickett horn. The output 288GHz beam is then coupled to an aspheric lens manufactured from low-loss, high-density polyethylene. This lens is employed to collimate the emerging beam. Small axial adjustment of the lens position can also be used to create a slowly focusing beam so as to optimize the measured signal. In addition, up-down or side-to-side adjustment of the lens can be utilized to steer the beam vertically or horizontally – again to optimize alignment. The propagating beam passes through a beam splitter and then through a water-free, bubble-free fused quartz window into the LAPD-U vacuum vessel. The beam-splitter is a thin sheet of G10 which reflects a small fraction of the incident power (~5 %) towards a zero-bias detector optimized for the frequency range from 220 to 300GHz. Note that waveguides at this frequency have dimensions of ~0.9mm x 0.45mm and so have very large conductive losses. This drives the use of quasi-optical propagation. The detector requires no DC bias and is very responsive (> 1V/mW into 1MΩ). Radiation is coupled to the detector via a similar lens-horn arrangement used for the launch. This reflected beam acts as the local oscillator or reference millimeter-wave beam for the detector. The remainder of the launched source beam then enters the LAPD-U vacuum vessel and passes through the plasma at the mid-plane until reaching the opposing port which is closed off with an aluminum flange. This flange is used as a mirror to retroreflect the incident 288GHz beam back along its path. The retroreflected beam exits the input port but does NOT couple directly into the zero-bias detector. Instead, the majority of the return power continues towards the 288GHz source. As mentioned above the transmitted beam enters the source a second time. This would appear undesirable. However, at these frequencies multipliers are highly non-linear elements which results in a significant portion of the return beam (~20%) re-emerging from the multiplier and horn and then coupling via the G10 beam-splitter to the zero-bias detector. This approach eliminated the need for a second quasi-optical beam-splitter. The system is extremely compact measuring approximately 28 inches x 20 inches. The above did not explain how heterodyne operation was achieved. As mentioned above the Gunn oscillator is able to be varactor tuned. This allows a low voltage to be applied to control the operating frequency of the Gunn oscillator. During heterodyne operation a sawtooth shaped voltage is applied to the varactor at 750kHz using an 80MHz Arbitrary Waveform Generator (AWG). This voltage changes the Gunn frequency linearly during the up-sweep which is then reset abruptly at the sawtooth crash to be immediately followed by another linear sweep. Passage through the 288GHz multiplier triples the frequency change experienced by the electromagnetic wave. These frequency changes are small – tens of megahertz. This FM radar approach results in the launched electromagnetic wave frequencies at the detector for the reference and plasma wave to be different. The approximately 10 ns delay propagation delay for the plasma beam results in the local oscillator and plasma beams NOT having an identical frequency – there is in fact a fixed difference frequency. The frequency tuning level of the Gunn oscillator is then adjusted so that there is ONE cycle of this difference frequency during each linear ramp. During the sawtooth crash or downward re-sweep this one cycle replays in reverse but on a very fast timescale. The process then repeats. Low-pass filtering eliminates the fast re-sweep to leave a pure sine wave heterodyne signal. When the plasma is present it introduces a phase delay in the sine wave (caused by the extremely small Doppler shift resulting from the optical path length change). Of course, to measure this phase change we need a reference. This is simply obtained from an arbitrary waveform generator which provides a synchronized output pulse train which again is low pass filtered to obtain a 750kHz sinusoidal voltage reference for the interferometer. The interferometer was installed on LAPD-U where it has worked reliably and has established that electron densities exceeding 1x10 13 cm -3 are routinely achieved. In addition, the system sensitivity was able to easily observe density fluctuation at frequencies up to 50kHz. FM Radar techniques have enabled a full demonstration of a compact, sensitive, high frequency (288GHz/1mm) heterodyne interferometer.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

System and method for adaptive optical tracking with selectable tracking modes

The present disclosure relates to an adaptive, free-space optical system. The system may have a controller and a digital micromirror (DMM) array responsive to the controller. The digital micromirror may include a plurality of independently controllable micromirror elements forming a receiver for receiving optical signals from an environmental scene. At least two of the plurality of independently controllable micromirror elements are steerable in different directions to receive optical signals emanating from two or more locations within the environmental scene. A beam steering subsystem forms a portion of the micromirror array and is in communication with the controller for receiving control signals from the controller. A detector is used to receive an incoming free space optical signal imaged by at least one of the micromirror elements.

Panas, Robert Matthew↗

Topics in Optical Design, Manufacturing, and Analysis

Presentation to be given at the LANL Detectors and Analysis Workshop December 5-6, 2023. This STIP is a resubmission of STIP 35977839 (an incorrect version of the document was sent through the STIP process previously).

42 ENGINEERING↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Scanless laser waveform measurement in the near-infrared

Field-resolved measurements of few-cycle laser waveforms allow access to ultrafast electron dynamics in light–matter interactions and are key to future lightwave electronics. Recently, sub-cycle gating based on nonlinear excitation in active pixel sensors has allowed the first single-shot measurements of mid-infrared optical fields. Extending the techniques to shorter wavelengths, however, is not feasible using silicon-based detectors with bandgaps in the near-infrared. Here, we demonstrate an all-optical sampling technique for near-infrared laser fields, wherein an intense fundamental field generates a sub-cycle gate through nonlinear excitation of a wide-bandgap crystal, in this case, ZnO, which can sample the electric field of a weak perturbing pulse. By using a crossed-beam geometry, the temporal evolution of the perturbing field is mapped onto a transverse spatial axis of the nonlinear medium, and the waveform is captured in a single measurement of the spatially resolved fluorescence emission from the crystal. The technique is demonstrated through field-resolved measurements of the field reshaping during nonlinear propagation in the ZnO detection crystal.

Truong, Tran-Chau (ORCID:0000000348940635)↗

Absolute calibration of the conical crystal configuration of the zinc spectrometer (ZSPEC) at the OMEGA laser facility

In this study, we present the absolute calibration of the conical crystal for the zinc spectrometer (ZSPEC), an x-ray spectrometer at the OMEGA laser facility at the Laboratory for Laser Energetics. The ZSPEC was originally designed to measure x-ray Thomson scattering using flat or cylindrically curved highly oriented pyrolytic graphite crystals centered around Zn He-alpha emission at 9 keV. To improve the useful spectral range and collection efficiency of the ZSPEC, a conical highly annealed pyrolytic graphite crystal was fabricated for the ZSPEC. The conically bent crystal in the Hall geometry produces a line focus perpendicular to the spectrometer axis, corresponding to the detector plane of electronic detectors at large scale laser facilities such as OMEGA, extending the useful range of the spectrometer to 7–11 keV. Further, using data collected using a microfocus Mo x-ray source, we determine important characteristics of ZSPEC such as the dispersion, spatial resolution, and absolute sensitivity of the instrument. A ray-trace model of ZSPEC provides another point of agreement in calculations of the ZSPEC dispersion and crystal response.

47 OTHER INSTRUMENTATION↗

Characterizing x-ray transmission through filters used in high energy density physics diagnostics

We report on the design and implementation of a new system used to characterize the energy-dependent x-ray transmission curve, Θ(E), through filters used in high-energy density physics diagnostics. Using an Amptek X-123-CdTe x-ray spectrometer together with a partially depleted silicon surface barrier detector, both the energy spectrum and total emission of an x-ray source have been accurately measured. By coupling these detectors with a custom PROTO-XRD x-ray source with interchangeable cathodes, accurate characterizations of Θ(E) for filters of varying materials and thicknesses have been obtained. The validity of the technique has been confirmed by accurately reproducing areal densities for high-purity filters with known x-ray transmission properties. In this paper, the experimental setup is described and the results of absorption calibrations performed on a variety of different filters are presented.

47 OTHER INSTRUMENTATION↗

Unconventional Applications of Superconducting Nanowire Single Photon Detectors

Superconducting nanowire single photon detectors are becoming a dominant technology in quantum optics and quantum communication, primarily because of their low timing jitter and capability to detect individual low-energy photons with high quantum efficiencies. However, other desirable characteristics, such as high detection rates, operation in cryogenic and high magnetic field environments, or high-efficiency detection of charged particles, are underrepresented in literature, potentially leading to a lack of interest in other fields that might benefit from this technology. We review the progress in use of superconducting nanowire technology in photon and particle detection outside of the usual areas of physics, with emphasis on the potential use in ongoing and future experiments in nuclear and high energy physics.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Fiber optic computing using distributed feedback

Abstract The widespread adoption of machine learning and other matrix intensive computing algorithms has renewed interest in analog optical computing, which has the potential to perform large-scale matrix multiplications with superior energy scaling and lower latency than digital electronics. However, most optical techniques rely on spatial multiplexing, requiring a large number of modulators and detectors, and are typically restricted to performing a single kernel convolution operation per layer. Here, we introduce a fiber-optic computing architecture based on temporal multiplexing and distributed feedback that performs multiple convolutions on the input data in a single layer. Using Rayleigh backscattering in standard single mode fiber, we show that this technique can efficiently apply a series of random nonlinear projections to the input data, facilitating a variety of computing tasks. The approach enables efficient energy scaling with orders of magnitude lower power consumption than GPUs, while maintaining low latency and high data-throughput.

97 MATHEMATICS AND COMPUTING↗

Results from the DUNE ND-LAr 2x2 Demonstrator Run 2

The Deep Underground Neutrino Experiment (DUNE) is a cutting-edge, long-baseline experiment under construction in the United States, based on large liquid-argon time projection chambers (LArTPCs). The DUNE Near Detector LArTPC (ND-LAr) will employ a novel modular architecture using a pixelated LArPix charge readout. To validate this design and characterize detector response, the 2×2 demonstrator—an array of eight optically isolated LArTPC modules—was deployed at Fermilab in 2024. During winter 2025, the 2x2 demonstrator was operated for a second data-taking campaign (Run 2) with the aim of studying the low-energy response of the detector. Run 2 focused on calibration and response studies using a suite of deployed radioactive sources. Gamma sources (²²Na, ⁶⁰Co, and ⁸⁸Y) were used to probe module-to-module performance variations, energy resolution, and calibrations. Neutron sources (AmBe and a pulsed neutron generator) enabled studies of neutron interactions in liquid argon, including inelastic scatters and neutron capture signals, relevant for low-energy backgrounds and detector modeling. In addition, the detector was doped with ²²⁰Rn, providing Bi–Po coincidence signals that allow precise calibration of the charge and scintillation response. This poster will present results from these calibration campaigns. These studies provide critical validation of the ND-LAr modular LArTPC concept and inform calibration and reconstruction strategies for the full DUNE near detector.

Mora-Lepin, Luis [Florida State U.] (ORCID:0000000↗

Measurement of laser absorption in underdense plasmas using near-field imaging of the incident and transmitted beams

Measurements of laser absorption in high-temperature, underdense plasmas produced at the Omega Laser Facility are made using two near-field imaging detectors that diagnose the spatial profile and energy of the port P9 beam before and after it transmits through the plasma. The incident beam is sampled using a partial reflection from a full-aperture, (30 cm-diam) uncoated wedge pickoff located before the target chamber vacuum window and final focus lens assembly. A concave mirror reduces the reflected beam size, allowing it to be recorded directly using a charged-coupled device (CCD) camera. The P9 transmitted beam diagnostic (P9TBD) characterizes the transmitted light by terminating the expanded beam on a semi-transparent diffuser and imaging the illuminated surface using a lens and CCD camera. The P9TBD samples a numerical aperture twice as large as the input beam, allowing the energy of transmitted beams with moderate levels of beam spray to be measured accurately. Calibration shots with no plasma provide a path to infer absorption without absolute photometric calibration of either detector. Lastly, the cross-calibration between the two detectors was measured to remain stable at ±200 ppm, enabling measurements of total beam absorption below 1% with ±0.07% error.

47 OTHER INSTRUMENTATION↗

Spectral characterization of an SPDC source with a fast broadband spectrometer

Knowing the properties of single photons produced in a Spontaneous Parametric Down-Conversion (SPDC) source can be crucial for specific applications and uses. In particular, the spectral properties are of key relevance. Here, we investigate a commercial SPDC source using our fast broadband spectrometer. Our analysis is a valid method for other SPDC sources, as well as other single-photon generation techniques, thus providing a good example of how to use this spectrometer design. We calibrate the spectrometer using known lines of the argon emission spectrum. We show that the two down-converted photons from the SPDC source have different spectral properties depending on the pump power, and under which condition we measured spectrally similar down-converted photons. Finally, we were able to reconstruct and investigate the spectral information for the pump photon.

79 ASTRONOMY AND ASTROPHYSICS↗

Boron-10 Doped Polysiloxanes as Matrix Materials for Application in the Simultaneous Detection and Discrimination of Gamma Rays and Fast and Thermal Neutrons

Three boron-10 enriched aromatic molecules have been synthesized and incorporated into two different commercial polysiloxane resins, Shin Etsu KER-6000 and Wacker SilRes H62-C. Scintillating fluorophores, 9,9-dimethyl-2-phenylfluorene (PhF) and 2,5-diphenyloxazole (PPO), were tested in combination with each resin and boron-10 molecule for the simultaneous detection of gamma rays, fast neutrons, and thermal neutrons. Here, the H62-C resin was able to solubilize a large amount of PhF, in excess of 20 wt%. Cure kinetics were controlled through the addition of divinylbenzene and phenyl tris(dimethylsiloxy)silane cross-linker solution to the H62-C resin, with rheology experiments demonstrating a large reduction in time to gelation when 20 wt% cross-linker solution was added, from more than 4 hours to less than 1 hour. These polysiloxane resins can be cured in 3 hours under air, while common poly(vinyltoluene) scintillators require at least 4 days of heating and oxygen-free conditions. PhF-doped KER-6000 with tolyl boronate pinacol ester exhibited the best overall performance with a light yield of 62% relative to EJ-200 and thermal neutron capture at energies up to 103 keVee (84 keVee for EJ254B-5). Additionally, four samples exhibited light yields surpassing an industry-standard boron-doped plastic scintillator, Eljen’s EJ254B-5. Over the course of ten months, the KER-6000 samples showed precipitation of dopant molecules, which reduced their light yield by 15% on average, while H62-C proved to be more stable with only a 6% reduction.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Quantum ghost imaging microscopy depth-of-field study

Quantum ghost imaging approaches have been proposed to enhance biological microscopy, for example, using 2D visible detectors to provide IR images or providing additional dimensions of spatial or spectral information. Toward the goal of making such imaging schemes practical, we compare image quality and depth-of-field between traditional images and ghost images at the same excitation levels. We measure how image quality and depth-of-field depend on the parameters of the entangled light produced using type-I spontaneous parametric down-conversion (SPDC). We use a pair of time-synchronized, photon-timing single-photon avalanche diode (SPAD) array detectors to capture two distinct microscope imaging paths simultaneously on a photon-pair-by-photon-pair basis: one in a traditional imaging pathway and the other a quantum ghost imaging pathway. We calculate the depth-of-field, resolution, contrast, and signal-to-noise ratio (SNR) through the parameter space of a β-Barium Borate (BBO) type-I bulk non-linear crystal length and angle. Our results provide a basis for choosing parameters for quantum ghost imaging with type-I SPDC sources.

47 OTHER INSTRUMENTATION↗

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

Photon Detection System for DUNE Low-Energy Physics Study and the Demonstration of a Timing Resolution of a Few Nanoseconds Using ProtoDUNE-SP PDS

Photon detection systems (PDS) are an integral part of liquid-argon neutrino detectors. Besides providing the timing information for an event, which is necessary for reconstructing the drift coordinates of ionizing particle tracks, photon detectors can be effectively used for other purposes, including triggering events, background rejection, and calorimetric energy estimation. PDS in particular for the DUNE Far Detector Module 2 is designed to achieve a more extended optical coverage (→4 ) with new-generation large-size PD modules based on the ARAPUCA technology. This will provide enhanced opportunities for the study of low-energy neutrino physics using PDS. The ARAPUCA technology was extensively tested within the ProtoDUNE-SP detector operated at the CERN neutrino platform. Here, we present a study of the timing resolution of ARAPUCA detectors using light emitted from a sample of energetic cosmic ray muons traveling parallel to the PDS. An intrinsic timing resolution in the order of 3 ns is observed for the ARAPUCA detectors. The excellent timing resolution ability of PDS can be exploited for further enhancing physics studies using the DUNE far detectors.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Dynamically Tunable Terahertz Emission Enabled by Anomalous Optical Phonon Responses in Lead Telluride

Lead telluride (PbTe), a narrow bandgap semiconductor commonly used in infrared detectors, exhibits anomalous vibrational and structural properties, making it appealing for thermoelectrics. Despite significant fundamental interest in the microscopic origins of its unusual vibrational properties, the optical functionalities stemming from phonons and electron–phonon coupling in PbTe have not been closely investigated. This work reports measurements of terahertz (THz) radiation from a PbTe single crystal following ultrafast optical excitation and investigates IR-active phonon responses as a function of excitation fluence and temperature. We uncover a spectrally tunable THz emission peak enabled by an epsilon-near-zero response of the coupled plasmon–longitudinal optical phonon mode that can be dynamically shifted via tuning photocarrier density. Spectral tunability (Δω/ω = 25%) is significant and beyond what has been achieved by any other THz emitter. In addition, the emitted THz fields reveal signatures of a zone center transverse optical phonon anomaly and unveil a new mode at 0.3 THz that diminishes in amplitude under increasing photocarrier density. Temperature-dependent measurements suggest that the transverse-like modes at 1 and 1.5 THz are possibly of different origins. These results indicate that the unusual phononic properties in PbTe are tunable via photoexcitation and enable new optical functionalities in THz applications, such as spectrally tunable emitters and all-optical modulators.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗