Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Occupancy distribution”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Data-driven occupant-behavior analytics for residential buildings

Many advances have been made in building technology to help save energy, but influencing the behavior of the occupants is still necessary to achieve low-energy use targets. One of the most practical ways to influence and change occupant behaviors is through incentives. Developing incentives for energy-saving and quantifying the impact of occupant behaviors are both active areas of research. Here, we propose a data analytics framework for detecting changes in occupant behaviors, which will help build an analytics feedback loop from behavior impact to incentive design. The framework has two major parts. The first forecasts energy consumption for each occupant, while the second determines a probability distribution for changes in energy consumption. The parts are interchangeable with other existing machine learning and statistical methods. A specific instantiation of the framework, using kernel ridge-regression for forecasting and k-means to find an empirical behavior distribution, is described in detail. An HVAC use-case with 5 different incentivized behaviors is used as an example to show that the framework can detect behavior changes induced by incentives. Furthermore, we show that some simpler behavior-change detection methods do not work, further justifying the use of advanced analytics.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Stochastic simulation of occupant-driven energy use in a bottom-up residential building stock model

The residential buildings sector is one of the largest electricity consumers worldwide and contributes disproportionally to peak electricity demand in many regions. Strongly driven by occupant activities, household energy consumption is stochastic and heterogeneous in nature. However, most residential energy models applied by industry use homogeneous, deterministic activity schedules, which work well for predictions of annual energy consumption, but can result in unrealistic hourly or sub-hourly electric load profiles, with exaggerated or muted peaks. The increasing proportion of variable renewable energy generators means that representing the heterogeneity and stochasticity of occupant behavior is now crucial for reliable planning at both bulk-power and distribution-system scales. This work presents a novel and open-source occupancy simulation approach that can simulate a diverse set of individual occupant and household event schedules for all major electricity, fuel, and hot water end uses. To accomplish this, we evaluated three alternative occupant activity simulation approaches before selecting a hybrid combining time-inhomogeneous Markov chains and probability-sampling of event durations and magnitudes. Further, we integrated the stochastic occupancy simulation with an open-source bottom-up physics-simulation building stock model and published a set of 550,000 diverse household end-use activity schedules representing a national housing stock. The simulator was verified against time-use survey data, and simulation results were validated against measured end-use electricity data for accuracy and reliability. While we use data for the United States, our application demonstrates how similar approaches could be applied using the time-use survey data collected in many countries around the world.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A Distributed Intelligent Automated Demand Response Building Management System

The goal of the 2.5 year Distributed Intelligent Automated Demand Response (DIADR) project was to reduce peak electricity load of Sutardja Dai Hall at UC Berkeley by 30% while maintaining a healthy, comfortable, and productive environment for the occupants. We sought to bring together both central and distributed control to provide “deep” demand response1 at the appliance level of the building as well as typical lighting and HVAC applications. This project brought together Siemens Corporate Research and Siemens Building Technology (the building has a Siemens Apogee Building Automation System (BAS)), Lawrence Berkeley National Laboratory (leveraging their Open Automated Demand Response (openADR), Auto-­Demand Response, and building modeling expertise), and UC Berkeley (related demand response research including distributed wireless control, and grid-­to-­building gateway development). Sutardja Dai Hall houses the Center for Information Technology Research in the Interest of Society (CITRIS), which fosters collaboration among industry and faculty and students of four UC campuses (Berkeley, Davis, Merced, and Santa Cruz). The 141,000 square foot building, occupied in 2009, includes typical office spaces and a nanofabrication laboratory. Heating is provided by a district heating system (steam from campus as a byproduct of the campus cogeneration plant); cooling is provided by one of two chillers: a more typical electric centrifugal compressor chiller designed for the cool months (Nov-­ March) and a steam absorption chiller for use in the warm months (April-­October). Lighting in the open office areas is provided by direct-­indirect luminaries with Building Management System-­based scheduling for open areas, and occupancy sensors for private office areas. For the purposes of this project, we focused on the office portion of the building. Annual energy consumption is approximately 8053 MWh; the office portion is estimated as 1924 MWh. The maximum peak load during the study period was 1175 kW. Several new tools facilitated this work, such as the Smart Energy Box, the distributed load controller or Energy Information Gateway, the web-­based DR controller (dubbed the Central Load-­Shed Coordinator or CLSC), and the Demand Response Capacity Assessment & Operation Assistance Tool (DRCAOT). In addition, an innovative data aggregator called sMAP (simple Measurement and Actuation Profile) allowed data from different sources collected in a compact form and facilitated detailed analysis of the building systems operation. A smart phone application (RAP or Rapid Audit Protocol) facilitated an inventory of the building’s plug loads. Carbon dioxide sensors located in conference rooms and classrooms allowed demand controlled ventilation. The extensive submetering and nimble access to this data provided great insight into the details of the building operation as well as quick diagnostics and analyses of tests. For example, students discovered a short-­cycling chiller, a stuck damper, and a leaking cooling coil in the first field tests. For our final field tests, we were able to see how each zone was affected by the DR strategies (e.g., the offices on the 7th floor grew very warm quickly) and fine-­tune the strategies accordingly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Energy Efficiency Services Sector: Workforce Education and Training Needs

This report provides a baseline assessment of the current state of energy efficiency-related education and training programs and analyzes training and education needs to support expected growth in the energy efficiency services workforce. In the last year, there has been a significant increase in funding for 'green job' training and workforce development (including energy efficiency), through the American Recovery and Reinvestment Act (ARRA). Key segments of the energy efficiency services sector (EESS) have experienced significant growth during the past several years, and this growth is projected to continue and accelerate over the next decade. In a companion study (Goldman et al. 2009), our research team estimated that the EESS will increase two- to four-fold by 2020, to 220,000 person-years of employment (PYE) (low-growth scenario) or up to 380,000 PYE (high-growth scenario), which may represent as many as 1.3 million individuals. In assessing energy efficiency workforce education and training needs, we focus on energy-efficiency services-related jobs that are required to improve the efficiency of residential and nonresidential buildings. Figure ES-1 shows the market value chain for the EESS, sub-sectors included in this study, as well as the types of market players and specific occupations. Our assessment does not include the manufacturing, wholesale, and retail distribution subsectors, or energy efficiency-focused operations and maintenance performed by facility managers.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Single crystal studies on boron-rich {tau}-borides Ni{sub 23-x}M{sub x}B{sub 6} (M=Zn, Ga, In, Sn, Ir)-The surprising occurrence of B{sub 4}-tetraheda as a normal case?

Single crystals of the cubic {tau}-borides Ni{sub 23-x}M{sub x}B{sub 6} (M=Zn, Ga, In, Sn, Ir) were synthesised from the elements at temperatures between 1200 and 1500 {sup o}C. The structure refinements show that the existence of boron-rich phases is quite common. Starting from the idealised composition Ni{sub 20}M'{sub 3}B{sub 6} a part of the metal atoms on site 8c is substituted by B{sub 4} tetrahedra. For M'=Ga a complete exchange seems to be possible leading to the composition Ni{sub 20}GaB{sub 14}. For M'=Zn and Sn the formation of solid solutions is less extended. For M'=In no exchange is observed but an unusual pattern of Ni/In distribution is observed. With M=Ir mixed occupations occur for all sites and the boron content varies, too. All compositions were confirmed by EDX measurements. - Graphical abstract: Crystal structure of {tau}-Borides M{sub 23}B{sub 6}; M1: M{sub 8}-cubes, M2: M{sub 12}-cuboctahedra centred by M3, isolated M-atoms: M4; grey circles: boron, black circles: metal atoms.

36 MATERIALS SCIENCE↗

Correlating Transport and Structural Properties in Li 1+ x Al x Ge 2– x (PO 4 ) 3 (LAGP) Prepared from Aqueous Solution

Li 1+ x Al x Ge 2– x (PO 4 ) 3 (LAGP) is a solid lithium-ion conductor belonging to the NASICON family, representing the solid solution of LiGe 2 (PO 4 ) 3 and AlPO 4 . The typical syntheses of LAGP either involve high-temperature melt-quenching, which is complicated and expensive, or a sol–gel process requiring costly organic germanium precursors. Herein, we report a simple method based on aqueous solutions without the need of ethoxide precursors. Using synchrotron and neutron diffraction, the crystal structure, the occupancies for Al and Ge, and the distribution of lithium were determined. Substitution of germanium by aluminum allows for an increased Li + incorporation in the material and the actual Li + content in the sample increases with the nominal Li + content and a solubility limit is observed for higher aluminum content. By means of impedance spectroscopy, an increase in the ionic conductivity with increasing lithium content is observed. Whereas the lithium ionic conductivity improves, due to the increasing carrier density, the bulk activation energy increases. This correlation suggests that changes in the transport mechanism and correlated motion may be at play in the Li 1+ x Al x Ge 2– x (PO 4 ) 3 solid solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Assessing Indoor versus Outdoor PM 2.5 Concentrations during the 2025 Los Angeles Fires Using the PurpleAir Sensor Network

In January 2025, a series of fast-moving wildland-urban-interface (WUI) fires swept through the Los Angeles (LA) metropolitan area, causing severe air pollution. While the impacts of WUI fires on outdoor air quality have been extensively studied, indoor exposure remains less understood, despite most people sheltering indoors during WUI fires. Here, this study investigates the spatial and temporal patterns of indoor and outdoor PM 2.5 concentrations across the South Coast Air Basin, with a focus on LA County during the LA fires. Using high-resolution data from co-located indoor and outdoor PurpleAir (PA) sensors, we analyze hourly PM 2.5 levels and indoor/outdoor ratios. Outdoor PM 2.5 concentrations spiked sharply during the fires, reaching unhealthy levels exceeding 130 μg/m 3 , compared to the mean concentration (12 μg/m 3 ) during non-fire hours. Indoor concentrations also increased, though to a lesser extent, peaking around 60 μg/m 3 compared to a mean of 7 μg/m 3 during non-fire hours. This reflects the partial shielding that indoor environments provide from outdoor air pollution. The mean (0.42) and median (0.29) indoor/outdoor PM 2.5 ratios during LA fire hours were lower than the mean (0.93) and median (0.66) ratios during non-fire hours. Indoor/outdoor PM 2.5 ratios across sensors showed a wide distribution, reflecting differences in building characteristics and occupant behavior, such as indoor activities and the use of air purifiers. These findings emphasize the need for guidance and interventions to reduce indoor PM 2.5 exposure and protect public health during extreme WUI fire events.

2025 Los Angeles Fires↗

Ground-state and dynamical properties of hard-core bosons in one-dimensional incommensurate optical lattices with a harmonic trap

We study properties of the strongly repulsive Bose gas on one-dimensional incommensurate optical lattices with a harmonic trap, which can be dealt with by use of an exact numerical method through Bose-Fermi mapping. We first exploit the phase transition of hard-core bosons in optical lattices from the superfluid to the Bose-glass phase as the strength of the incommensurate potential increases. Then we study the dynamical properties of the system after suddenly switching off the harmonic trap. We calculate the one-particle density matrices, the momentum distributions, and the natural orbitals and their occupations for both the static and dynamic systems. Our results indicate that the Bose-glass and superfluid phases display quite different properties and expansion dynamics.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Spatial patterns in occupancy and density of larval lampreys in freshwater habitats restored to a Stage 0 condition

Abstract We examined occupancy and density of larval lampreys ( Entosphenus tridentatus and Lampetra spp.) in two rivers in Oregon (USA) restored to a Stage 0 condition 1–5 years prior, using a multiscale occupancy model and a zero‐inflated Poisson mixture model. We sampled lampreys using backpack electrofishing in randomly distributed, paired, 1‐m 2 quadrats and recorded environmental data. Probabilities of occupancy and density were higher when water velocity was low, the substrate was noncompacted, and sediment was dominated by fines (<4 mm). At mean water depth (0.34 m) and velocity (0.09 m/s), estimated densities in occupied quadrats were 4.8 lampreys/m 2 (95%: 3.4–6.9) when the substrate was compacted, and fines were not dominant, and 21.1 lampreys/m 2 (95%: 17.7–25.3) when the substrate was noncompacted and fines were dominant. Probabilities of detecting occupancy in a 1‐m 2 quadrat sampled by backpack electrofishing were 0.76 (95%: 0.64–0.87) when captured after visual observation and 0.80 (95%: 0.71–0.88) with blind sweeps (i.e., constantly moving the net regardless of observation). The probability of capturing a single lamprey in a quadrat sampled by blind sweeps was 0.32 (95%: 0.27–0.37). Sampling in paired 1‐m 2 quadrats facilitated concurrent examination of patterns in occupancy and density while accounting for capture probability, which could aid temporal monitoring of restored habitats. To the best of our knowledge, this is the first study to document occupancy and estimate densities of larval lampreys in habitats that underwent valley floor restoration to Stage 0. We observed both lamprey genera within 5 years of restoration. Aquatic restoration that increases low‐velocity, noncompacted, fine sediment habitats could benefit lampreys.

Harris, Julianne E.↗

Structural, magnetic, and Mössbauer spectroscopy of Cu substituted M-type hexaferrites

Highlights: • Single BaM hexaferrite structural phases with Cu substations were prepared. • The magnetocrystalline anisotropy decreased with Cu substitution. • The coercivity was significantly modified while the magnetization remained high. • Hexaferrites with 0.2–0.4 Cu possess properties suitable for magnetic recording. • Ionic distributions from structural refinement agreed with Mössbauer spectroscopy. - Abstract: BaFe{sub 12−x}Cu{sub x}O{sub 19} hexaferrites were prepared using ball milling and sintering at 1100 °C. Refinement of the X-ray diffraction patterns was carried out to determine the structural parameters and the ionic distribution over the crystallographic sites. The preferential site occupation and valence state of Cu was consistent with the results obtained from the analysis of Mössbauer spectra. Further, the magnetic parameters of the samples were discussed in light of the structural and Mössbauer analyses. The magnetic phase transition temperature was found to decrease with the level of Cu substitution, in accordance with the reduction of the superexchange interactions. Further, the magnetic softening of the hexaferrite and the significant reduction in magnetocrystalline anisotropy with Cu substitution was consistent with the ionic distribution in the lattice. This study clearly demonstrated the feasibility of using a simple method to fabricate hexaferrites with a modified coercivity, while maintain the saturation magnetization high enough for practical applications.

36 MATERIALS SCIENCE↗

Nuclear spin features relevant to ab initio nucleon-nucleus elastic scattering

Effective interactions for elastic nucleon-nucleus scattering from first principles require the use of the same nucleon-nucleon interaction in the structure and reaction calculations, as well as a consistent treatment of the relevant operators at each order. Previous work using these interactions has shown good agreement with available data. Here, we study the physical relevance of one of these operators, which involves the spin of the struck nucleon, and examine the interpretation of this quantity in a nuclear structure context. Using the framework of the spectator expansion and the underlying framework of the no-core shell model, we calculate and examine spin-projected, one-body momentum distributions required for effective nucleon-nucleus interactions in $J=0$ nuclear states. The calculated spin-projected, one-body momentum distributions for $^4$He, $^6$He, and $^8$He display characteristic behavior based on the occupation of protons and neutrons in single particle levels, with more nucleons of one type yielding momentum distributions with larger values. Additionally, we find this quantity is strongly correlated to the magnetic moment of the $2^+$ excited state in the ground state rotational band for each nucleus considered. In conclusion, we find that spin-projected, one-body momentum distributions can probe the spin content of a $J=0$ wave function. This feature may allow future ab initio nucleon-nucleus scattering studies to inform spin properties of the underlying nucleon-nucleon interactions. The observed correlation to the magnetic moment of excited states illustrates a previously unknown connection between reaction observables such as the analyzing power and structure observables like the magnetic moment.

6 ≤ A ≤ 19↗

Superconducting surface impedance under radiofrequency field

Based on BCS theory with moving Cooper pairs, the electron states distribution at 0K and the probability of electron occupation with finite temperature have been derived and applied to anomalous skin effect theory to obtain the surface impedance of a superconductor under radiofrequency (RF) field. We present the numerical results for Nb and compare these with representative RF field-dependent effective surface resistance measurements from a 1.5 GHz resonant structure.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Developing a Thermodynamic Model for the Interactions between Water and Cu in the Zeolite SSZ-13

The Cu-exchanged zeolite SSZ-13 is an efficient catalyst in the selective catalytic reduction of nitrous oxides in the presence of ammonia, and understanding the nature of the active sites under realistic conditions is important in rationalizing its activity. Especially the interactions between Cu and water have drawn significant amounts of attention in recent years. In this work we develop a thermodynamic model for the water coordination of Cu based on static calculations and present occupational probabilities and phase diagrams for different Al distributions at different temperatures and water pressures. We find that only at high temperatures and low pressures is the bare Cu cation the most stable species and that the cation is solvated at lower temperatures and higher pressures. In the following we compare our results to experimental and theoretical work in this field and find good agreement. This work shows that it is possible to construct an accurate thermodynamic model for water interactions with Cu in zeolites and it will be interesting to see how a similar methodology can be applied to elucidate different problems in the future.

Göltl, Florian↗

Metrics for Interzonal Dispersion Assessment of Airborne SARS-CoV-2 Within Office Buildings

High ventilation rate is increasingly considered as a mitigation strategy in the rapid spread of COVID-19 in existing buildings in addition to other options like UVGI and added filtration. However, this and other similar measures may also impact energy use and the efficiency of the buildings in which they are installed. Without concrete metrics, the impact of all these potential changes to the system cannot be properly assessed relative to the other impacts the measures might have, including additional energy use, added operation and maintenance costs, and reduced system life. Multizone airflow and contaminant transport simulations involving parameters such as infiltration rate, system configuration, and level of occupancy can provide critical information on relative risk distribution within a building. In this study, prototype airflow models are used to assess the degree to which ventilation-related measures can mitigate the spread of a virus like SARS-CoV-2 in a similar way that prototype energy models are used to study energy efficiency measures. A new detailed medium-sized office building prototype model is developed using the CONTAM software to represent contaminant transport in buildings like those modeled by the U.S. Department of Energy’s detailed medium office prototype model. The goal of this study is to generate a set of suitable metrics that will give a whole-building picture of airborne SARS-CoV-2 virus distributions across the different zones of the building under different parameters and scenarios.

DeGraw, Jason↗

Surface Impedance of Superconducting Radio Frequency (SRF) Materials

Superconducting radio frequency (SRF) technology is widely adopted in particle accelerators. There remain many open questions, however, in developing a systematic understanding of the fundamental behavior of SRF materials, including niobium treated in different ways and various other bulk/thin film materials that are fabricated with different methods under assorted conditions. A facility that can measure the SRF properties of small samples in a range of 2-40 K temperature is needed in order to fully answer these questions. The Jefferson Lab surface impedance characterization (SIC) system has been designed to attempt to meet this requirement. It consists of a sapphire-loaded cylindrical Nb TE011 cavity at 7.4 GHz with a 50 mm diameter flat sample placed on a non-contacting end plate and uses a calorimetric technique to measure the radio frequency (RF) induced heat on the sample. Driving the resonance to a known field on this surface enables one to derive the surface resistance of a relatively small localized area. TEo11 mode identification has been done at room temperature and 4 K, and has been compared with Microwave Studio® and SuperFish simulation results. RF loss mechanisms in the SIC system are under investigation. A VCO phase lock loop system has been used in both CW and pulsed mode. Two calorimeters, with stainless steel and Cu as the thermal path material for high precision and high power versions, respectively, have been designed and commissioned for the SIC system to provide low temperature control and measurement. A power compensation method has been developed to measure the RF induced power on the sample. Simulation and experimental results show that with these two calorimeters, the whole thermal range of interest for SRF materials has been covered. The power measurement error in the interested power range is within 1.2% and 2.7% for the high precision and high power versions, respectively. Temperature distributions on the sample surface for both versions have been simulated and the accuracy of sample temperature measurements have been analysed. Both versions have the ability to accept bulk superconductors and thin film superconducting samples with a variety of substrate materials such as AI, Al20 3 , Cu, MgO, Nb and Si. Tests with polycrystalline and large grain bulk Nb samples have been done at <15 mT magnetic field. Based on BCS surface impedance, least-squares fittings have been done using SuperFit2.0, a code developed by G. Ciovati and the author. Microstructure analyses and SRF measurements of large scale epitaxial MgB2 films have been reported. MgB2 films on 5 em dia. sapphire disks were fabricated by a Hybrid Physical Chemical Vapor Deposition (HPCVD) technique. The electron-beam backscattering diffraction (EBSD) results suggest that the film is a single crystal complying with a MgB2(0001 )//AI203(0001) epitaxial relationship. The SRF properties of different film thicknesses (200 nm and 350 nm) were evaluated using SIC system under different temperatures and applied fields at 7.4 GHz. A surface resistance of 9±2 1-10 has been observed at 2.2 K. Based on BCS theory with moving Cooper pairs, the electron states distribution at OK and the probability of electron occupation with finite temperature have been derived and applied to anomalous skin effect theory to obtain the surface impedance of a superconductor with moving Cooper pairs. We present the numerical results for Nb.

Xiao, Binping↗

Spectrocopic measurements of water vapor plasmas at high resolution: The optical transition probabilities for OH (A 2 Sigma - X 2 Pi)

Emission and absorption spectra of water vapor plasmas generated in a wall-stabilized arc at atmospheric pressure and 4 current, and at 0.03 atm and 15 to 50 A, were measured at high spatial and spectral resolution. The gas temperature was determined from the shape of Doppler-broadened rotational lines of OH. The observed nonequilibrium population distributions over the energy levels of atoms are interpreted in terms of a theoretical state model for diffusion-controlled arc plasmas. Excellent correlation is achieved between measured and predicted occupation of hydrogen energy levels. It is shown that the population distribution over the nonpredissociating rotational-vibrational levels of the A 2 Sigma state of OH is close to an equilibrium distribution at the gas temperature, although the total density of this state is much higher than its equilibrium density. The reduced intensities of the rotational lines originating in these levels yielded Boltzmann plots that were strictly linear.

Klein, L.↗

Building Agent™ Software (BA) [SWRs 12-05 and 17-21]

Energy interfaces provide a new level of motivational information. Many studies have reported energy savings after dashboards for operators are installed, but these provide little actionable information to the occupant and the occupant cannot report individual comfort. The Building Agent™ (BA), in development at the National Renewable Energy Laboratory (NREL), provides an interface for the occupant to converse with the building control system and aims to actively engage and affect occupant behavior to achieve positive energy outcomes. Energy savings achieved via occupant behavioral changes could be as high as 25%, and could rival savings achieved by technological measures. For example, energy audits often show that more than 50% of the energy used in a building is consumed at night. Occupants leaving equipment and lighting on after they leave work is a large contributing factor. Similar savings opportunities have been identified when occupants were away from their desks 50% of the time, while most of their computers, lights, and other equipment remained powered on. Building Agent aims to create cohesion between building automation system (BAS) data, local measurements, and occupant feedback to provide visualizations, empowering occupants and building engineers to take diagnostic, proactive, energy-saving, and comfort-improving actions. The multilayer BA architecture consists of central server, measurement, and distributed application layers. The server layer aggregates global and localized measurements with occupant feedback to correlate perceived comfort with actual data throughout the building. The measurement layer complements BAS data with localized, environmental condition measurements at workstations. The application layer provides a bidirectional communications mechanism between the building and the occupants that accepts comfort feedback and provides energy performance information. The interface layer also uses three displays to influence building energy use: empathetic and personalized gauges, graphical data, and competitive rankings. Building Agent was implemented at NREL in the Research Support Facility (RSF), a LEED Platinum and Net Zero office building, which has received many awards. The constant feedback from occupants has enabled BA to better enhance the BAS data controls. Continued work is being done on BA to increase visualization of data and enhanced the user experience.

Long, Nicholas↗

Co-Simulation of Electric Power Distribution Systems and Buildings including Ultra-Fast HVAC Models and Optimal DER Control

Smart homes and virtual power plant (VPP) controls are growing fields of research with potential for improved electric power grid operation. A novel testbed for the co-simulation of electric power distribution systems and distributed energy resources (DERs) is employed to evaluate VPP scenarios and propose an optimization procedure. DERs of specific interest include behind-the-meter (BTM) solar photovoltaic (PV) systems as well as heating, ventilation, and air-conditioning (HVAC) systems. The simulation of HVAC systems is enabled by a machine learning procedure that produces ultra-fast models for electric power and indoor temperature of associated buildings that are up to 133 times faster than typical white-box implementations. Hundreds of these models, each with different properties, are randomly populated into a modified IEEE 123-bus test system to represent a typical U.S. community. Advanced VPP controls are developed based on the Consumer Technology Association (CTA) 2045 standard to leverage HVAC systems as generalized energy storage (GES) such that BTM solar PV is better utilized locally and occurrences of distribution system power peaks are reduced, while also maintaining occupant thermal comfort. An optimization is performed to determine the best control settings for targeted peak power and total daily energy increase minimization with example peak load reductions of 25+%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗