Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “ORAL CAVITY”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

233 records · Page 13

SU-D-204-04: Correlations Between Dosimetric Indices and Follow-Up Data for Salivary Glands Six Months After Radiation Therapy for Head and Neck Cancer

Purpose: To investigate the correlation between different dosimetric indices of salivary glands (as separate or combined structures) to patient-reported dry mouth 6 months post radiotherapy using the novel patient reported outcome version of the CTCAE (PRO-CTCAE). Methods: Forty-three patients with oropharyngeal squamous cell carcinoma were treated on a prospective multi-institutional study. All patients received de-intensified 60 Gy intensity modulated radiotherapy. Dosimetric constraints were used for the salivary glands (e.g. mean dose to the contralateral-parotid < 26 Gy). We investigated correlations of individual patient dosimetric data of the parotid and submandibular glands (as separate or combined structures) to their self-reported 6 month post-treatment dry mouth responses. Moderate dry mouth responses were most prevalent and were used as the clinical endpoint indicating response. The correlation of Dmean, Dmax and a range of dosevolume (VD) points were assessed through the area under the Receiver Operating Characteristic curve (ROC) and Odds Ratios (OR). Results: Patients reporting non/mild dry mouth response (N=22) had average Dmean = 19.6 ± 6.2Gy to the contralateral-parotid compared to an average Dmean = 28.0 ± 8.3Gy and an AUC = 0.758 for the patients reporting moderate/severe/very severe dry mouth (N=21). Analysis of the range of VD’s for patients who had reported dry mouth showed that for the contralateral-parotid the indices V18 through V22 had the highest area under the curves (AUC) (0.762 – 0.772) compared to a more traditional dosimetric index V30, which had an AUC = 0.732. The highest AUC was observed for the combination of contralateral parotid and contralateral submandibular glands, for which V16 through V28 had AUC = 0.801 – 0.834. Conclusion: Patients who report moderate/severe/very severe dry mouth 6 months post radiotherapy had on average higher Dmean. The V16-V28 of the combination of the contralateral glands showed the highest correlation with the clinical endpoint.

60 APPLIED LIFE SCIENCES↗

SU-D-204-05: Fitting Four NTCP Models to Treatment Outcome Data of Salivary Glands Recorded Six Months After Radiation Therapy for Head and Neck Tumors

Purpose: To estimate the radiobiological parameters of four popular NTCP models that describe the dose-response relations of salivary glands to the severity of patient reported dry mouth 6 months post chemo-radiotherapy. To identify the glands, which best correlate with the manifestation of those clinical endpoints. Finally, to evaluate the goodness-of-fit of the NTCP models. Methods: Forty-three patients were treated on a prospective multiinstitutional phase II study for oropharyngeal squamous cell carcinoma. All the patients received 60 Gy IMRT and they reported symptoms using the novel patient reported outcome version of the CTCAE. We derived the individual patient dosimetric data of the parotid and submandibular glands (SMG) as separate structures as well as combinations. The Lyman-Kutcher-Burman (LKB), Relative Seriality (RS), Logit and Relative Logit (RL) NTCP models were used to fit the patients data. The fitting of the different models was assessed through the area under the receiver operating characteristic curve (AUC) and the Odds Ratio methods. Results: The AUC values were highest for the contralateral parotid for Grade ≥ 2 (0.762 for the LKB, RS, Logit and 0.753 for the RL). For the salivary glands the AUC values were: 0.725 for the LKB, RS, Logit and 0.721 for the RL. For the contralateral SMG the AUC values were: 0.721 for LKB, 0.714 for Logit and 0.712 for RS and RL. The Odds Ratio for the contralateral parotid was 5.8 (1.3–25.5) for all the four NTCP models for the radiobiological dose threshold of 21Gy. Conclusion: It was shown that all the examined NTCP models could fit the clinical data well with very similar accuracy. The contralateral parotid gland appears to correlated best with the clinical endpoints of severe/very severe dry mouth. An EQD2Gy dose of 21Gy appears to be a safe threshold to be used as a constraint in treatment planning.

60 APPLIED LIFE SCIENCES↗

SU-G-201-12: Investigation of Beta-Emitter 90Sr-90Y Dose Distribution Using Gafchromic EBT3 Film for Application On Conformal Skin Brachytherapy Device

Purpose: To investigate {sup 90}Sr-{sup 90}Y as a high dose rate (HDR) source for application in a conformal skin brachytherapy (CSBT) device. The CSBT device has been previously developed to provide patient specific treatment for small inoperable lesions and irregular surfaces. Methods: A popular beta emitter, {sup 90}Sr-{sup 90}Y was tested for feasibility in a CSBT device. A 1 cm diameter plaque was used to deliver dose to a solid water phantom containing EBT3 Gafchromic films arranged at the surface and perpendicular to it. Additionally, a 1 cm diameter 6 MeV electron beam was used to irradiate EBT3 film at 100 cm SSD with a 0.5 cm bolus. Films were digitized with an Epson Expression 10000 XL scanner and calibrated with a 6 MeV electron specific dose curve. Normalized percent depth doses (PDD) and dose profiles for both techniques were analyzed using ImageJ. Results: Dose distributions achieved with the {sup 90}Sr-{sup 90}Y sources were compared with those of external electron beam radiation therapy (EBRT). Penumbra (20%- 80%) for EBRT and 90Sr-90Y were 4.3 mm and 1.6 mm, respectively. PDD values of 50% (normalized to 2 mm) were 10.1 mm and 2.8 mm for electron and {sup 90}Sr-{sup 90}Y, respectively. Flatness (80% of the central beam profile) was 14.1% at a 5 mm depth for EBRT and 4.0% at surface for the {sup 90}Sr-{sup 90}Y. Conclusion: As expected, the PDDs of {sup 90}Sr-{sup 90}Y in water are shallower than that of external electron beams for the same field size. {sup 90}Sr-{sup 90}Y can be used in CSBT to provide patient specific treatment where shallower depth doses than that provided by electron external beams may be required: e.g. eyelids, nose, lips, ears, etc. The customizability of EBRT could be replicated by using multiple adjacent {sup 90}Sr-{sup 90}Y plaque placements.

61 RADIATION PROTECTION AND DOSIMETRY↗

WE-AB-207B-08: Exploring and Refining the QUANTEC Guideline to Reduce Severe Hyposalivation Following IMRT for Head and Neck Cancer

Purpose: The aim of this study was to investigate the usefulness of the QUANTEC guideline to prevent xerostomia after intensity-modulated radiotherapy (IMRT) for head and neck cancer (HNC) with respect to follow-up time. In addition, we explored alternative guidelines to further reduce xerostomia. Methods: The QUANTEC guideline suggests a mean dose to the contralateral (Dmeancontra) parotid<20 Gy, or Dmeancontra and Dmean to the ipsilateral parotid (Dmeanipsi)<25 Gy. Stimulated whole mouth saliva flow measurements (WMSFM) were conducted at a median of 11 (3–24) months for 63 patients treated with IMRT for HNC to a median dose of 70 Gy in 2006–2015. Severe hyposalivation/xerostomia was defined as WMSFM ≤25% post- relative to pre-RT. Patients were stratified into a <6m (xerostomia: 27% (n=15)), and a 6–24m (xerostomia: 19% (n=10)) follow-up group. Dose-response modeling was performed using logistic regression including Dmeancontra, or Dmeancontra and Dmeanipsi. The area under the receiver-operating characteristics curve (AUC) was used to assess discriminative ability, and the agreement between the estimated and observed rate of xerostomia was given by Spearman’s rank correlation coefficient (Rs), and related p-values. Results: Of the non-xerostomia patients, 65% (<6m) and 56% (6–24m) fulfilled Dmeancontra<20 Gy. The estimated and observed rate of xerostomia agreed at <6m (AUC=0.78; Rs=0.46; p=0.001), and was 28% at Dmeancontra=20 Gy. A smaller number of non-xerostomia patients fulfilled the two-gland guideline (33% (<6m) and 26% (6–24m)), but the AUC was higher than using Dmeancontra only (<6m: AUC=0.90; Rs=0.63; p<0.0001; 6–24m: AUC=0.84; Rs=0.25; p=0.08), and the following amendment of the two-gland guideline was suggested: (0.17*Dmeancontra+0.11*Dmeanipsi-8.13)<-1.60 (<6m), and (0.05*Dmeancontra+0.02*Dmeanipsi-3.10)<-1.60 (6–24m). Conclusion: The QUANTEC guideline is effective to prevent xerostomia <6m post-RT, but its usefulness is reduced at later follow-up times. The suggested amendment to the two-gland QUANTEC guideline should be further investigated in an independent cohort of HNC patients treated with IMRT.

60 APPLIED LIFE SCIENCES↗

Magnetic resonance spectroscopy of the human brain

I give a brief description of the magnetic resonance spectroscopy (MRS) in the human brain examinations. MRS allows a noninvasive chemical analysis of the brain using a standard high field MR system. Nowadays, the dominant form of MR brain spectroscopy is proton spectroscopy. Two main techniques of MRS, which utilize the chemical shift of metabolites in the external magnetic field, are SVS (single voxel) and CSI (single slice). The major peaks in the spectrum of a normal brain include NAA, Cr, Cho and m-Ins, which are neuronal, energetic, membrane turnover and glial markers, respectively. In disease, two pathological metabolites can be found in the brain spectra: Lac, which is end product of anaerobic glycolysis and Lip, which is a marker of membrane breakdown, occurring in necrosis. The common way to analyze clinical spectra is to determine metabolite ratios, e.g. NAA/Cr, Cho/Cr, Cho/NAA. This analysis permits a safe and noninvasive examination of the brain tissue as each disease state has its own characteristic spectroscopic image. MRS is a valuable diagnostic tool in such clinical applications as detecting brain tumors and differentiating tumors from inflammatory and infectious processes. Proton MRS is also very helpful in diagnostic of ischemic lesions, Alzheimer’s disease and hepatic encephalopathy. The MRS brain spectra should always be correlated with the Magnetic Resonance Imaging (MRI) results and alone cannot make neurological diagnosis.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Predicting Individual Affect of Health Interventions to Reduce HPV Prevalence

Recently, human papilloma virus has been implicated to cause several throat and oral cancers and hpv is established to cause most cervical cancers. A human papilloma virus vaccine has been proven successful to reduce infection incidence in FDA clinical trials and it is currently available in the United States. Current intervention policy targets adolescent females for vaccination; however, the expansion of suggested guidelines may extend to other age groups and males as well. This research takes a first step towards automatically predicting personal beliefs, regarding health intervention, on the spread of disease. Using linguistic or statistical approaches, sentiment analysis determines a texts affective content. Self-reported HPV vaccination beliefs published in web and social media are analyzed for affect polarity and leveraged as knowledge inputs to epidemic models. With this in mind, we have developed a discrete-time model to facilitate predicting impact on the reduction of HPV prevalence due to arbitrary age and gender targeted vaccination schemes.

59 BASIC BIOLOGICAL SCIENCES↗

Blood Vessel Normalization in the Hamster Oral Cancer Model for Experimental Cancer Therapy Studies

Normalization of tumor blood vessels improves drug and oxygen delivery to cancer cells. The aim of this study was to develop a technique to normalize blood vessels in the hamster cheek pouch model of oral cancer. Materials and Methods: Tumor-bearing hamsters were treated with thalidomide and were compared with controls. Results: Twenty eight hours after treatment with thalidomide, the blood vessels of premalignant tissue observable in vivo became narrower and less tortuous than those of controls; Evans Blue Dye extravasation in tumor was significantly reduced (indicating a reduction in aberrant tumor vascular hyperpermeability that compromises blood flow), and tumor blood vessel morphology in histological sections, labeled for Factor VIII, revealed a significant reduction in compressive forces. These findings indicated blood vessel normalization with a window of 48 h. Conclusion: The technique developed herein has rendered the hamster oral cancer model amenable to research, with the potential benefit of vascular normalization in head and neck cancer therapy.

60 APPLIED LIFE SCIENCES↗

Long-Term Assessment of Critical Radionuclides and Associated Environmental Media at the Savannah River Site - 13038

During the operational history of the Savannah River Site (SRS), many different radionuclides have been released from site facilities. However, only a relatively small number of the released radionuclides have been significant contributors to doses and risks to the public. At SRS dose and risk assessments indicate tritium oxide in air and surface water, and Cs-137 in fish and deer have been, and continue to be, the critical radionuclides and pathways. In this assessment, statistical analyses of the long-term trends of tritium oxide in atmospheric and surface water releases and Cs-137 concentrations in fish and deer are provided. Correlations also are provided with 1) operational changes and improvements, 2) geopolitical events (Cold War cessation), and 3) recent environmental remediation projects and decommissioning of excess facilities. For example, environmental remediation of the F- and H-Area Seepage Basins and the Solid Waste Disposal Facility have resulted in a measurable impact on the tritium oxide flux to the onsite Fourmile Branch stream. Airborne releases of tritium oxide have been greatly affected by operational improvements and the end of the Cold War in 1991. However, the effects of SRS environmental remediation activities and ongoing tritium operations on tritium concentrations in the environment are measurable and documented in this assessment. Controlled hunts of deer and feral hogs are conducted at SRS for approximately six weeks each year. Before any harvested animal is released to a hunter, SRS personnel perform a field analysis for Cs-137 concentrations to ensure the Hunter's dose does not exceed the SRS administrative game limit of 0.22 milli-sievert (22 mrem). However, most of the Cs-137 found in SRS onsite deer is not from site operations but is from nuclear weapons testing fallout from the 1950's and early 1960's. This legacy source term is trended in the SRS deer, and an assessment of the 'effective' half-life of Cs-137 in deer (including the physical decay half-life and the environmental dispersion half-life) is provided. The 'creek mouth' fisherman is the next most critical pathway at SRS. On an annual basis, three species of fish (panfish, catfish, and bass) are sampled from the mouths of the five SRS streams. Three composites of up to five fish of each species are analyzed from each sampling location. Long-term trending of the Cs-137 concentrations in fish and the subsequent doses from consumption of SRS fish is provided. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Estimates of Internal Dose Resulting from I-131 Patients in Hotels - Paper 147

U.S. Nuclear Regulatory Commission Regulatory Guide 8.39 provides the following estimate to the maximum internal committed effective dose, CED{sub i}, to an individual from a released patient having received radionuclide therapy: CED{sub i} = 10{sup -5} Q{sub adm} DCF where Q{sub adm} = activity administered to the patient (Bq), DCF = ingestion dose coefficient (Sv/Bq). Since many released patients stay in a hotel for a day or two after administration of the I-131, an effort was made to provide reasonable estimates of internal committed effective dose to a housekeeper at a hotel. Reasonable exposure scenarios are presented herein with the resulting doses. The value 10{sup -6} from a health physics 'rule of thumb' for intake in workplace environments, and explored by Brodsky, was multiplied by a factor of 10 to account for the most highly exposed individual and to add a degree of conservatism to the evaluation. The ingestion dose coefficient was used since it was felt that the maximum internal intake would either be via the skin or mouth. The scenarios investigated to date and presented herein show rather low potential doses of hotel housekeepers due to internal contamination. The internal doses are conservative since they assume the immediate release and placement of the patient in the hotel or household. The existing Reg. Guide 8.39 internal dose estimate appears to be very conservative and are very low in comparison to external gamma ray dose due to released patients. (authors)

61 RADIATION PROTECTION AND DOSIMETRY↗

Progress on the Design and Fabrication of the MICE Focusing Magnets

The Muon Ionization Cooling Experiment (MICE) focusing solenoid magnets focus the muon beam within the MICE cooling channel on a liquid or solid absorber that is within the warm bore of solenoid. The focusing magnet has a warm bore of 470 mm. his magnet consists of two coils 210-mm long that is separated by an aluminum mandrel that is 200 mm long. Each of the coils has its own leads. The coils may be operated in either the non-flip mode (solenoid mode with both coils at the same polarity) or the lip mode (quadrupole focusing mode where both coils are at opposite polarity). This report describes the focusing solenoid magnet design that will be built by the vendor. The progress on the construction of the first of the focusing magnets will also be discussed in this report. Ultimately three of these magnets will be built. These magnets will be cooled using a pair 1.5 W (at 4.2 K) pulse tube coolers.

42 ENGINEERING↗

Dependences of mucosal dose on photon beams in head-and-neck intensity-modulated radiation therapy: a Monte Carlo study

Dependences of mucosal dose in the oral or nasal cavity on the beam energy, beam angle, multibeam configuration, and mucosal thickness were studied for small photon fields using Monte Carlo simulations (EGSnrc-based code), which were validated by measurements. Cylindrical mucosa phantoms (mucosal thickness = 1, 2, and 3 mm) with and without the bone and air inhomogeneities were irradiated by the 6- and 18-MV photon beams (field size = 1 Multiplication-Sign 1 cm{sup 2}) with gantry angles equal to 0 Degree-Sign , 90 Degree-Sign , and 180 Degree-Sign , and multibeam configurations using 2, 4, and 8 photon beams in different orientations around the phantom. Doses along the central beam axis in the mucosal tissue were calculated. The mucosal surface doses were found to decrease slightly (1% for the 6-MV photon beam and 3% for the 18-MV beam) with an increase of mucosal thickness from 1-3 mm, when the beam angle is 0 Degree-Sign . The variation of mucosal surface dose with its thickness became insignificant when the beam angle was changed to 180 Degree-Sign , but the dose at the bone-mucosa interface was found to increase (28% for the 6-MV photon beam and 20% for the 18-MV beam) with the mucosal thickness. For different multibeam configurations, the dependence of mucosal dose on its thickness became insignificant when the number of photon beams around the mucosal tissue was increased. The mucosal dose with bone was varied with the beam energy, beam angle, multibeam configuration and mucosal thickness for a small segmental photon field. These dosimetric variations are important to consider improving the treatment strategy, so the mucosal complications in head-and-neck intensity-modulated radiation therapy can be minimized.

61 RADIATION PROTECTION AND DOSIMETRY↗

A Comprehensive Assessment of Biologicals Contained Within Commercial Airliner Cabin Air

Both culture-based and culture-independent, biomarker-targeted microbial enumeration and identification technologies were employed to estimate total microbial and viral burden and diversity within the cabin air of commercial airliners. Samples from each of twenty flights spanning three commercial carriers were collected via air-impingement. When the total viable microbial population was estimated by assaying relative concentrations of the universal energy carrier ATP, values ranged from below detection limits (BDL) to 4.1 x 106 cells/cubic m of air. The total viable microbial population was extremely low in both of Airline A (approximately 10% samples) and C (approximately 18% samples) compared to the samples collected aboard flights on Airline A and B (approximately 70% samples). When samples were collected as a function of time over the course of flights, a gradual accumulation of microbes was observed from the time of passenger boarding through mid-flight, followed by a sharp decline in microbial abundance and viability from the initiation of descent through landing. It is concluded in this study that only 10% of the viable microbes of the cabin air were cultivable and suggested a need to employ state-of-the art molecular assay that measures both cultivable and viable-but-non-cultivable microbes. Among the cultivable bacteria, colonies of Acinetobacter sp. were by far the most profuse in Phase I, and Gram-positive bacteria of the genera Staphylococcus and Bacillus were the most abundant during Phase II. The isolation of the human pathogens Acinetobacter johnsonii, A. calcoaceticus, Janibacter melonis, Microbacterium trichotecenolyticum, Massilia timonae, Staphylococcus saprophyticus, Corynebacterium lipophiloflavum is concerning, as these bacteria can cause meningitis, septicemia, and a handful of sometimes fatal diseases and infections. Molecular microbial community analyses exhibited presence of the alpha-, beta-, gamma-, and delta- proteobacteria, as well as Gram-positive bacteria, Fusobacteria, Cyanobacteria, Deinococci, Bacterioidetes, Spirochetes, and Planctomyces in varying abundance. Neisseria meningitidis rDNA sequences were retrieved in great abundance from Airline A followed by Streptococcus oralis/mitis sequences. Pseudomonas synxantha sequences dominated Airline B clone libraries, followed by those of N. meningitidis and S. oralis/mitis. In Phase II, Airline C, sequences representative of more than 113 species, enveloping 12 classes of bacteria, were retrieved. Proteobacterial sequences were retrieved in greatest frequency (58% of all clone sequences), followed in short order by those stemming from Gram-positives bacteria (31% of all clone sequences). As for overall phylogenetic breadth, Gram-positive and alpha-proteobacteria seem to have a higher affinity for international flights, whereas beta-and gamma-proteobacteria are far more common about domestic cabin air parcels in Airline C samples. Ultimately, the majority of microbial species circulating throughout the cabin airs of commercial airliners are commensal, infrequently pathogenic normal flora of the human nasopharynx and respiratory system. Many of these microbes likely originate from the oral and nasal cavities, and lungs of passengers and flight crew and are disseminated unknowingly via routine conversation, coughing, sneezing, and stochastic passing of fomites. The data documented in this study will be useful to generate a baseline microbial population database and can be utilized to develop biosensor instrumentation for monitoring microbial quality of cabin or urban air.

microbial diversity↗

L-band Dielectric Constant Measurements of Seawater (Oral presentation and SMOS Poster)

This paper describes a resonant cavity technique for the measurement of the dielectric constant of seawater as a function of its salinity. Accurate relationships between salinity and dielectric constant (which determines emissivity) are needed for sensor systems such as SMOS and Aquarius that will monitor salinity from space in the near future. The purpose of the new measurements is to establish the dependence of the dielectric constant of seawater on salinity in contemporary units (e.g. psu) and to take advantage of modern instrumentation to increase the accuracy of these measurements. The measurement device is a brass cylindrical cavity 16cm in diameter and 7cm in height. The seawater is introduced into the cavity through a slender glass tube having an inner diameter of 0.1 mm. By assuming that this small amount of seawater slightly perturbs the internal fields in the cavity, perturbation theory can be employed. A simple formula results relating the real part of the dielectric constant to the change in resonant frequency of the cavity. In a similar manner, the imaginary part of the dielectric constant is related to the change in the cavity s Q. The expected accuracy of the cavity technique is better than 1% for the real part and 1 to 2% for the imaginary part. Presently, measurements of methanol have been made and agree with precision measurements in the literature to within 1% in both real and imaginary parts. Measurements have been made of the dielectric constant of seawater samples from Ocean Scientific in the United Kingdom with salinities of 10, 30, 35 and 38 psu. All measurements were made at room temperature. Plans to make measurements at a range of temperatures and salinities will be discussed.

Lang, Roger H.↗

Development of Oral Fomulation of SCV-07 for Use in Tuberculosis

An evaluation of the immunomodulatory peptide SCV-07 was conducted as a possible therapeutic treatment for tuberculosis. This evaluation included mouse models, clinical trials and various forms of the drug such as liquid injection and development of an oral pill. It was found that SCV-07 significantly increased the survival rate of animals infected with lethal doses of Mycobacterium bovis. It enhanced the functional activity of macrophages in a dose-dependent fashion. The combination of SCV-07 with bacteriostatic drugs, such as izoniazid, was particularly effective. Phase II clinical trials in a TB clinic demonstrated that the usage of the injection form of SCV-07 for lung TB treatment in combination with standard chemotherapy decreased the quantity of patients with positive sputum assays for Mycobacteria, promoted healing of cavities in lungs, stabilized parameters of cell immunity, and resulted in a significant improvement in the general condition of patients. Clinical trials results of the oral drug form are still being evaluated.

60 APPLIED LIFE SCIENCES↗

Randomized Trial of Oral Misoprostol Treatment for Cervical Ripening Before Tandem Application in Cervix Cancer

Purpose: To investigate the efficacy of oral misoprostol administered to facilitate tandem application to the cervix as a part of brachytherapy in patients with cervical cancer. Methods and Materials: Eighty patients with cervical cancer who had been planned to undergo brachytherapy at Dr. Luetfi Kirdar Kartal Training and Research Hospital were evaluated in a double-blind, prospective, randomized trial. Patients were divided randomly into two groups of 40 patients. The first and second groups received 400 {mu}g of misoprostol orally and placebo, respectively, 3 h before tandem application. The two groups were compared in terms of age, diameter of tumor, parity, age at first intercourse, amount of bleeding and pain at first tandem application, length of endometrial cavity measured by hysterometer, and size of Hegar dilators used for cervical dilatation. Results: Of all cases, 63.6%, 16.3%, 10%, 6.3%, 2.5%, and 1.3% were Stage IIB, IIIB, IIIA, IVA, IIA and IIC, respectively. Mean ({+-}SD) age (range) was 49.3 {+-} 13.1 (25-83) years and 56.6 {+-} 13.2 (30-78) years in the study and control groups, respectively (p = 0.015). Age at first intercourse, diameter of tumor, parity, amount of bleeding at first tandem application, and length of endometrial cavity measured by hysterometer were not significantly different between the two groups. Pain score was significantly higher in the control group (p < 0.001). Application was significantly easier in the study group compared with controls (p < 0.001). Average size of initial Hegar dilators used for cervical dilatation was significantly higher in the study group compared with controls (p = 0.017). Conclusion: Administration of misoprostol 400 {mu}g orally for cervical ripening before tandem application facilitates the procedure, increases patient tolerability and comfort, and may decrease complication rates.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Spin Testing for Durability Began on a Self-Tuning Impact Damper for Turbomachinery Blades

NASA and Pratt & Whitney will collaborate under a Space Act Agreement to perform spin testing of the impact damper to verify damping effectiveness and durability. Pratt & Whitney will provide the turbine blade and damper hardware for the tests. NASA will provide the facility and perform the tests. Effectiveness and durability will be investigated during and after sustained sweeps of rotor speed through resonance. Tests of a platform wedge damper are also planned to compare its effectiveness with that of the impact damper. Results from baseline tests without dampers will be used to measure damping effectiveness. The self-tuning impact damper combines two damping methods-the tuned mass damper and the impact damper. It consists of a ball located within a cavity in the blade. This ball rolls back and forth on a spherical trough under centrifugal load (tuned mass damper) and can strike the walls of the cavity (impact damper). The ball s rolling natural frequency is proportional to the rotor speed and can be designed to follow an engine-order line (integer multiple of rotor speed). Aerodynamic forcing frequencies typically follow these engineorder lines, and a damper tuned to the engine order will most effectively reduce blade vibrations when the resonant frequency equals the engine-order forcing frequency. This damper has been tested in flat plates and turbine blades in the Dynamic Spin Facility. During testing, a pair of plates or blades rotates in vacuum. Excitation is provided by one of three methods--eddy-current engine-order excitation (ECE), electromechanical shakers, and magnetic bearing excitation. The eddy-current system consists of magnets located circumferentially around the rotor. As a blade passes a magnet, a force is imparted on the blade. The number of magnets used can be varied to change the desired engine order of the excitation. The magnets are remotely raised or lowered to change the magnitude of the force on the blades. The other two methods apply force to the rotating shaft itself at frequencies independent of the rotor speed. During testing, blade vibration is monitored with strain gauges and laser displacement probes.

Duffy, Kirsten↗