Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Neutronics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Measurement of the Neutron Electromagnetic Form Factor Ratio at High Momentum Transfer

The inner structure of the nucleon (proton and neutron) remains a topic of great interest in nuclear and particle physics, after many decades of study. For example, understanding the quark-gluon dynamics inside the nucleon would shed light on how 99% of the nucleon mass is created. The neutron electromagnetic form factors, Gn E and Gn M , give important insights into the neutron structure. The Super BigBite Spectrometer (SBS) program at Jefferson Lab (JLab) seeks to extend the form factor measurements for both the proton and the neutron. The neutron electric form actor, Gn E , has been historically difficult to measure due to the short lifetime of the free neutron and the small value of Gn E . The GEn-II experiment is part of the SBS program and seeks to measure Gn E , significantly increasing the high momentum transfer coverage. A newly designed polarized 3He target increased the figure of merit by three times compared to previous measurements. The analysis of this data is especially challenging due to the unprecedented high-rate environment caused by the open nature of the spectrometer with a direct line of sight to the target. This required developing new Gas Electron Multiplier (GEM) particle trackers which can cover large areas demanded by this setup and handle particle rates up to 500 kHz/cm2. Rates this high over a large area is unprecedented in particle tracking systems and came with a number of challenges. Data taken in the SBS program was critical to understanding hardware and software solutions that improved the track reconstruction efficiency to be >97% with a position resolution of 70 ?m. In previous experiments the proton electromagnetic form factors, Gp E and Gp M were measured up to Q2 = 8.5 GeV2 and Q2 = 30 GeV2, respectively, while Gn E has only been measured up to Q2 = 3.4 GeV2. The GEn-II experiment has measured the neutron form factor ratio, Gn E/Gn M, at Q2 values of 2.90, 6.50, and 9.47 GeV2 by scattering a polarized electron beam with a polarized 3He target, used here as an effective polarized neutron target, and measuring the double spin asymmetry of the cross section. Previous Gn E measurements do not extend above Q2 = 3.4 GeV2, and therefore this analysis has extended the world data by almost three times. The background correction is especially difficult at the higher Q2 settings leading to large systematic errors. As very exploratory results from this early analysis of the data, we find for Q2 = 2.90 GeV2, Gn E = 0.0157 ±stat 0.0016 ±sys 0.0011, for Q2 = 6.50 GeV2, Gn E = 0.0067 ±stat 0.0019 ±sys 0.0005, and for Q2 = 9.46 GeV2, Gn E = 0.0046 ±stat 0.0023 ±sys 0.0005. These results are compared to predictions from the Dyson-Schwinger Equations (DSE) model and a Relativistic Constituent Quark Model (RCQM).

Jeffas, Sean↗

Proton discrimination in CLYC for fast neutron spectroscopy

The Cs 2 LiYCl 6 :Ce (CLYC) elpasolite scintillator is known for its response to fast and thermal neutrons along with good γ-ray energy resolution. While the 35 Cl(n,p) reaction has been identified as a potential means for CLYC-based fast neutron spectroscopy in the absence of time-of-flight (TOF), previous efforts to functionalize CLYC as a fast neutron spectrometer have been thwarted by the inability to isolate proton interactions from 6 Li(n,α) and 35 Cl(n,α) signals. This work introduces a new approach to particle discrimination in CLYC for fission spectrum neutrons using a multi-gate charge integration algorithm that provides excellent separation between protons and heavier charged particles. Neutron TOF data were collected using a 252 Cf source, an array of EJ-309 organic liquid scintillators, and a 6 Li-enriched CLYC scintillator outfitted with fast electronics. Modal waveforms were constructed corresponding to the different reaction channels, revealing significant differences in the pulse characteristics of protons and heavier charged particles at ultrafast, fast, and intermediate time scales. These findings informed the design of a pulse shape discrimination algorithm, which was validated using the TOF data. This study also proposes an iterative subtraction method to mitigate contributions from confounding reaction channels in proton and heavier charged particle pulse height spectra, opening the door for CLYC-based fast neutron and γ-ray spectroscopy while preserving sensitivity to thermal neutron capture signals.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Angular-spectral filtering of recoil protons for optimization of fast neutron imaging employing proton converters

Fast neutron imaging is an important capability for diverse applications such as inertial confinement fusion diagnostics, cargo security, nuclear nonproliferation and arms control, and industrial inspection. Traditional phosphor image plates can be enhanced for fast neutron imaging using hydrogenous plastic converters which allow fast neutrons to scatter off hydrogen nuclei to produce energetic protons that can be recorded by the image plate. However, protons emitted by image plates are not constrained in their emission angle, which contributes to the blur of the resulting image. Here, we investigate two methods that can alter the spatial extent of converted protons that deposit energy in the image plate: reducing the converter thickness, and introducing a proton filter between the plastic converter and image plate to reduce the contribution of lower-energy, off-axis protons to the image. Here we determine the optimal plastic converter thickness for maximizing the signal intensity to be 2–3 mm through Monte Carlo simulations, and we benchmark this result against experimental measurements with a deuterium-tritium (DT) neutron generator. Next, we evaluate the image smearing and signal loss for various converters to show that solely reducing the converter thickness has the expected effect of reducing the blur from proton image smearing of the sharpness of an edge recorded on the image plate at the cost of reducing the signal intensity. The use of a proton filter is shown to achieve a similar improvement of edge sharpness as reducing the converter thickness while also sacrificing the signal intensity. We conclude that the use of proton energy filtering can improve the sharpness of fast neutron images in situations where the converter thickness cannot be reduced below some practical minimum. For more intense neutron sources, the signal intensity is of less concern, and optimizing the resolution of the image plate and therefore of the imaging system could have greater value. In these applications, proton filters may allow for improved fast neutron imaging measurements.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Derivation of at-birth neutron energy distribution of americium-beryllium source based on ISO8529 spectral data

In many practical applications, the accuracy of neutron transport calculations depends on an estimate of the energy distribution provided in the source definition. While the energy distribution of neutrons emitted by spontaneous fission sources is well-defined, the spectra of neutrons produced in (α,n) reactions in compound mixtures, such as americium-beryllium (AmBe), depend on the microstructural properties of the source material, which may vary. Although the energy of neutrons produced in nuclear reactions can be calculated from first principles, such computations require detailed knowledge of the key characteristics of the source material, which are often unknown. Here, this study focuses on deriving the at-birth neutron energy distribution for an AmBe source by applying reverse transport calculations to the externally measured high-precision spectrum recommended in the latest revision of the international standard. The derived at-birth spectrum was validated through indirect energy-sensitive neutron emission rate measurements of AmBe sources calibrated at national primary metrology institutions. The resulting at-birth neutron energy distribution serves as essential input data for radiation transport modeling, providing a validated spectrum for broader experimental and computational applications.

AmBe↗

Simulations of neutron unbound physics for Geant4

The study of neutron unbound systems via the invariant mass technique is the primary focus of the MoNA Collaboration, which built and operates the Modular Neutron Array (MoNA) and the Large multi-Institutional Scintillator Array (LISA) at FRIB. Advancements in nuclear structure from theory and experiment along the neutron dripline have presented opportunities to understand the nature of unbound systems in higher mass nuclei. The GEometry ANd Tracking (Geant4) platform has been used in high-energy and nuclear physics to simulate particle interactions with as much detail as the user desires. Geant4 currently does not have a physics class to simulate neutron unbound systems. Given the advancement of accelerator facilities and active searches along the neutron dripline, detailed simulations to study the breakup of neutron unbound systems, are necessary. Furthermore, the implementation of the breakup of neutron unbound systems in Geant4 will be presented.

Neutron dripline↗

Neutron stars and the dense matter equation of state

The past two decades have witnessed tremendous progress in understanding the properties of neutron stars, their maximum mass and radii, and the properties of the dense matter in their cores, made possible by electromagnetic observations of neutron stars and the detection of gravitational waves from their mergers. These observations have provided novel constraints on neutron-star structure that are intimately related to the properties of dense neutron-rich matter described by the nuclear equation of state. Nevertheless, constraining the equation of state over the wide range of densities probed by astrophysical observations is still challenging, as the physics involved is broad and the system spans many orders of magnitude in density. Here, theoretical approaches to calculate and model the neutron-star equation of state in various regimes of densities are reviewed, and the related consequent properties of neutron stars are discussed. How the equation of state at low densities can be calculated from nuclear interactions that are constrained and benchmarked by nuclear experiments is described. Neutron-star observations, with a particular emphasis on information provided by gravitational-wave signals and electromagnetic observations, are reviewed. Finally, future challenges and opportunities in the field are discussed.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Time-Resolved Neutron Imaging for Hydrogen Uptake in Subsurface Lithologies

Geologic hydrogen production and underground storage are increasingly important for meeting rising energy demands while providing clean-combustion advantages. However, hydrogen’s high diffusivity and propensity for leakage through porous media necessitate direct evaluation of its transport behavior in subsurface materials. Whereas X-ray microcomputed tomography (μCT) studies often employ contrast agents or surrogate gases, this study leverages neutron transmission radiography/CT to observe hydrogen migration in situ. This work represents the first demonstration of real-time neutron radiography of hydrogen migration in reservoir and caprock lithologies. Cylindrical cores of Indiana limestone, Amherst Gray sandstone, and Tumey shale were subjected to constant-pressure hydrogen charging and scanned in real time using high-resolution neutron radiography. Results indicate immediate hydrogen infiltration in sandstone and limestone, with homogeneous distribution detected throughout their pore structure. In contrast, hydrogen remained largely absent from fine-grained shale under the same pressure, except in an apparently localized fracture zone, where neutron signatures confirmed the presence of hydrogen. Subsequent neutron CT of the sandstone sample, using image subtraction against an uncharged reference, corroborated hydrogen distribution patterns. Even under lowpressure, single-phase conditions, distinct neutron imaging signatures of hydrogen were achieved. These preliminary findings underscore the potential of neutron imaging for advancing subsurface hydrogen migration research.

08 HYDROGEN↗

Large radiation back-flux from Monte Carlo simulations of fusion neutron–material interactions

Abstract Fusion power reactors will generate intense neutron fluxes into plasma-facing and structural materials (SMs). Radiation back-fluxes, generated from neutron–material interactions under these fluxes, can dramatically impact the plasma dynamics, e.g. by seeding runaway electrons during disruptions via Compton scattering of background electrons by wall-emitted gamma radiation. Here, we quantify these back-fluxes, including neutrons, gamma rays, and electrons, using Monte Carlo calculations for a range of SM candidates and first wall (FW) thicknesses. The radiation back-flux magnitudes are remarkably large, with neutron and gamma radiation back-fluxes on the same order of magnitude as the incident fusion neutron flux. Electron back-fluxes are two orders of magnitudes lower, but are emitted at sufficiently high energies to impact the sheath and boundary plasma dynamics. Material configuration plays a key role in determining back-flux magnitudes. The SM chiefly determines the neutron back-flux magnitude, while the FW thickness principally attenuates the gamma ray and electron back-fluxes. In addition to prompt back-fluxes, which are emitted immediately after fusion neutrons impact the surface, significant delayed gamma ray and electron back-fluxes arise from nuclear decay processes in the activated materials. These delayed back-flux magnitudes range from 2% to 7% of the prompt back-fluxes, and remain present during transients when fusion no longer occurs. During disruptions, build-up of delayed gamma radiation back-flux represents potential runaway electron seeding mechanisms, posing additional challenges for disruption mitigation in a power reactor compared with non-nuclear plasma operations. This work highlights the impact of these radiation back-fluxes plasma performance and demonstrates the importance of considering back-flux generation in materials selection for fusion power reactors.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Stellarator Design Exploration Using Symbolic-Regression Neutronics Surrogates

Systems codes require fast, simplified models to rapidly evaluate fusion power plant concepts, but neutronics analyses are often a computational bottleneck. Here, to address this, surrogate models for key neutronics responses have been developed using 3-D neutronics-ready models built with the open-source code ParaStell from a database of stellarator equilibria. Neutronics responses such as tritium breeding ratio (TBR), nuclear heating, and neutron-induced radiation damage displacements per atom (dpa) were simulated using OpenMC. Through sensitivity analysis and symbolic regression (SR), simple power-law formulas were derived connecting these neutronics responses to global stellarator parameters, including fusion power, plasma surface area, and plasma elongation. Validation shows these formulas can predict the simulation results with low error, enabling quick and accurate assessment of neutronics requirements in stellarator design exploration activities with systems codes.

Modeling↗

Feasibility of an Active Interrogation System to Classify Waste with He-4 Neutron Spectroscopy

This work investigates a 4 He-detector active interrogation system that leverages neutron spectroscopy to classify nuclear waste streams. MCNP models tested the concept through the simulation of a D-D neutron generator, an array of 4 He detectors, and various waste compositions. The fast-neutron Differential Die-Away signature was augmented with a neutron-energy discrimination signature. This signature isolates induced fission neutrons, the energy of which is greater than that of the D-D monoenergetic spectrum. With the incorporation of this spectroscopic technique, the measurement time decreased by 3–9% (depending on the degree of neutron moderation and absorption presented by the sample), demonstrating how neutron spectroscopy can enhance active interrogation methods. The reduced measurement times would have significant financial and logistical benefits for facilities with large footprints of low-level waste production.

4He detectors↗

Pulsed-Neutron Experiments at the Inherently Safe Subcritical Assembly

The pulsed neutron technique is a powerful, dynamic method to assay the reactivity of a multiplying system. This work presents the novel application of the pulsed neutron technique to the Inherently Safe Subcritical Assembly, an experimental configuration accepted by the International Criticality Safety Benchmark Evaluation Project Handbook. The experiments were replicated with COG11.3, a continuous-energy Monte Carlo code. The pulsed neutron data were analyzed using the Sjöstrand and Gozani area-ratio methods and by extracting the prompt neutron decay constant. Subsequent static k-eigenvalue and 𝛼-eigenvalue simulations were also performed for the same configurations. Neutron detector dead-time effects from the experiments were corrected using the Backwards Extrapolation Method and shown to have a negligible impact on the estimated reactivities. The results highlight that capturing time-dependent effects like delayed neutron precursor buildup are essential to accurately reproduce experimental results. They also highlight the importance of shielding the detectors from generator source neutrons in deeply subcritical configurations.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Production of neutrons from interactions of GCR-like particles

In order to help assess the risk to astronauts due to the long-term exposure to the natural radiation environment in space, an understanding of how the primary radiation field is changed when passing through shielding and tissue materials must be obtained. One important aspect of the change in the primary radiation field after passing through shielding materials is the production of secondary particles from the breakup of the primary. Neutrons are an important component of the secondary particle field due to their relatively high biological weighting factors, and due to their relative abundance, especially behind thick shielding scenarios. Because of the complexity of the problem, the estimation of the risk from exposure to the secondary neutron field must be handled using calculational techniques. However, those calculations will need an extensive set of neutron cross section and thicktarget neutron yield data in order to make an accurate assessment of the risk. In this paper we briefly survey the existing neutron-production data sets that are applicable to the space radiation transport problem, and we point out how neutron production from protons is different than neutron production from heavy ions. We also make comparisons of one the heavy-ion data sets with Boltzmann-Uehling-Uhlenbeck (BUU) calculations.

Non-NASA Center↗

Predictions of secondary neutrons and their importance to radiation effects inside the International Space Station

As part of a study funded by NASA MSFC to assess thecontribution of secondary particles in producing radiation damage to optoelectronics devices located on the International Space Station (IS), Monte Carlo calculations have been made to predict secondary spectra vs. shielding inside ISS modules and in electronics boxes attached on the truss (Armstrong and Colborn, 1998). The calculations take into account secondary neutron, proton, and charged pion production from the ambient galactic cosmic-ray (GCR) proton, trapped proton, and neutron albedo environments. Comparisons of the predicted neutron spectra with measurments made on the Mir space station and other spacecraft have also been made (Armstrong and Colborn, 1998). In this paper, some initial results from folding the predicted neutron spectrum inside ISS modules from Armstrong and Colborn (1998) with several types of radiation effects response functions related to electronics damage and astronaut-dose are given. These results provide an estimate of the practical importance of neutrons compared to protons in assessing radiation effects for the ISS. Also, the important neutron energy ranges for producing these effects have been estimated, which provides guidance for onboard neutron measurement requirements.

Neutrons↗

Artemis III Neutron Surface Science

This paper highlights lunar neutron science that can be performed in support of the Artemis 2024 mission within 6 degrees of the lunar south pole. There are two primary science goals: the characterization of the radiation environment, and secondly, inference of regolith composition including the presence of water. Characterizing the surface radiation environment is important for risk identification and mitigation during crewed lunar missions. The lunar surface radiation environment includes a unique neutron contribution. The relative contribution from neutrons is higher outside the shielding effects of Earth’s magnetic field, which the Moon experiences ~25% of its orbit. To evaluate the radiation risk to astronauts at the lunar surface, fast neutron measurements are needed. Neutrons are generated when galactic cosmic rays (GCR) collide with the lunar regolith and provide valuable elemental composition information about the near surface (< 1m). For the characterization of regolith composition, a low energy neutron spectrometer or counter can determine surface composition. This provides ground truth for orbital neutron data from the Lunar Reconnaissance Orbiter and Lunar Prospector missions.

Lunar science, Moon, geology, geophysics, neutron ↗

Incident beam optics optimization for the single crystal neutron diffractometer Pioneer with a polarized beam option

Pioneer, a next-generation single-crystal neutron diffractometer, is under development for Oak Ridge National Laboratory’s Second Target Station. Designed to address a wide range of scientific questions, Pioneer will deliver homogeneous neutron beams with customizable size and divergence and provide a polarized beam option. This article introduces its incident beam optics, highlighting the optimization methodology and the simulated performance. Pioneer will utilize a modified elliptical-straight guide for neutron transport and deploy slit packages and insertable apertures to control beam size and divergence. The optimized guide geometry matches the optimal-and-full-sample-illumination condition, and the beam control system effectively filters out unwanted neutrons while preserving the desired ones. In addition, we have found that polygon-approximated guides provide satisfactory transport efficiency and beam homogeneity, eliminating the need for truly curved guides. Further, to enhance neutronics performance and reduce cost, the coatings of supermirror elements are individually optimized to the lowest half-integer m-values that are sufficient to deliver the desired neutrons. After evaluating polarizing V-cavities and 3 He spin filters over the default polarized wavelength band of 1.2–5.5 Å, we selected a translatable multichannel polarizing V-cavity as the incident beam polarizer. Strategically placed at a location where the beam divergence is low and a large in-guide gap has negligible impact on transport efficiency, the optimized V-cavity achieves an average P 2 T of ~35%.

47 OTHER INSTRUMENTATION↗

Performance assessment of PHITS simulations for the inverse-kinematic p( 7 Li,n) 7 Be reaction based on fast-neutron measurements with a diamond detector

The inverse-kinematics p( 7 Li,n) 7 Be reaction produces forward-focused neutron emission, offering enhanced usable flux and reduced shielding requirements. Reliable simulation of such neutron fields is essential for the development of compact accelerator-based neutron sources. In this study, a PHITS-based simulation framework for the reaction was experimentally assessed using fast-neutron measurements. Forward-directed neutrons were measured with a diamond neutron detector and quantitatively compared with simulations with newly prepared IK-Frag cross-section file based on the proton-induced reaction data in ENDF/B-VIII.1, TENDL-2023, and JENDL-4.0/HE. Measurements and simulations were performed for incident 7 Li 3+ energies ranging from 15.0 to 25.0 MeV using a 50 μm-thick polypropylene target. For all conditions, the PHITS-based simulation framework reproduced the deposited energy spectra at the correct order of magnitude. The comparison of deposited energy spectra in the diamond detector showed high correlation coefficients across all investigated energies, indicating reasonable agreement in spectral shape between simulations and measurements. This work represents an initial step toward establishing a benchmark for PHITS simulations of the inverse kinematic reaction between an incident lithium-ion and a proton target.

43 PARTICLE ACCELERATORS↗

Fast neutron irradiation capability in existing thermal test reactors

In today’s nuclear industry, momentum towards the design, licensing, and construction of advanced nuclear demonstration plants, including fast reactors, is at a remarkably high level. However, there are currently no dedicated fast spectrum irradiation test facilities in the United States to support the development of fast spectrum technologies. As a result, a unique situation is developing where most of these plants will likely be designed by leveraging historic nuclear material technologies, but where the further optimization and advancement is impeded by the lack of fast neutron irradiation test facilities. While these circumstances present a challenge, there are some near-term opportunities that, if seized, can still help develop advanced fast reactor materials to a meaningful level of readiness to support future commercial fast reactors. Here, in this paper, we assess the feasibility of using thermal neutron filtering materials in existing experiment positions in the Advanced Test Reactor (ATR) at Idaho National Laboratory and the High Flux Isotope Reactor (HFIR) at Oak Ridge National Laboratory to simulate fast reactor test environments for nonfuel test specimens. Items investigated include the incident neutron flux (both fast and thermal), the total neutron fluence and cumulative atom displacements, helium production rate due to thermal neutron capture in nickel, and the potential impact that the thermal neutron filter material has on the cycle length of a given reactor. It is concluded that while HFIR provides the highest fast flux of all the options investigated, it is limited in the amount of thermal neutron filtering material that can be introduced into an experiment position without significantly affecting the operation of the reactor. Irradiation in Outboard-A positions in the ATR was found to be the most realistic near-term experiment avenue due to having ample space for several capsules in a moderately fast flux.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Global characterization of a laser-generated neutron source

Laser-driven neutron sources are routinely produced by the interaction of laser-accelerated protons with a converter. They present complementary characteristics to those of conventional accelerator-based neutron sources (e.g. short pulse durations, enabling novel applications like radiography). We present here results from an experiment aimed at performing a global characterization of the neutrons produced using the Titan laser at the Jupiter Laser Facility (Livermore, USA), where protons were accelerated from 23 $\mathrm {\mu }$ m thick plastic targets and directed onto a LiF converter to produce neutrons. For this purpose, several diagnostics were used to measure these neutron emissions, such as CR-39, activation foils, time-of-flight detectors and direct measurement of $^7{\rm Be}$ residual activity in the LiF converters. The use of these different, independently operating diagnostics enables comparison of the various measurements performed to provide a robust characterization. These measurements led to a neutron yield of $2.0\times 10^{9}$ neutrons per shot with a modest angular dependence, close to that simulated.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗