Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “National Electric Code”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Lessons Learned on Mega-Constellation Deployments and Impact to Space Domain Awareness

The breakneck expansion of multi-payload launches in low Earth orbit (LEO) has seen significant escalation over the last three years in the Space Domain Awareness (SDA) enterprise. The uptick in satellite deployment frequency, gradation of mega-constellation deployments utilizing electric propulsion, and surge in metric observation density from the Space Surveillance Network (SSN) have driven major system enhancements to ensure spaceflight safety. Beginning with the launch phase, new tactics, software, and procedures have been developed over the last few years to optimize the tasking of the SSN and ensure custody of all recently launched satellites that are added to the space catalog. Ensuring appropriate tasking levels were pivotal during the satellite separation phase, which necessitated updates to the mission systems for improved delineation between clustered satellites in a short window of time. The improved incorporation of utilizing satellite owner/operator-provided ephemeris coupled with critical code improvements have revolutionized how we maintain custody of Earth orbiting objects. The exponential population growth of Low-Earth orbiting satellites have also increased the quantity of Conjunction Data Messages sent out to partners such as the Trajectory Operations Group (TOPO) in Johnson Space Center. We will discuss the need for continued collaboration between the National Aeronautics and Space Administration (NASA) and other mega-constellation satellite operators to safeguard human spaceflight operations. Lastly, we will discuss how mega-constellations are driving best practices for safe operations across the space community.

Christian Ramos↗

Lessons Learned on Mega-Constellation Deployments and Impact to Space Domain Awareness

The breakneck expansion of multi-payload launches in low Earth orbit (LEO) has seen significant escalation over the last three years in the Space Domain Awareness (SDA) enterprise. The uptick in satellite deployment frequency, gradation of Mega-constellation deployments utilizing electric propulsion, and surge in metric observation density from the Space Surveillance Network (SSN) have imposed major system enhancements to ensure spaceflight safety. Beginning with the launch phase, new tactics, software, and procedures have been developed over the last few years to optimize the tasking of the SSN and ensure custody of all recently launched satellites that are added to the space catalog. Ensuring appropriate tasking levels were pivotal during the satellite separation phase, which necessitated updates to the mission systems for improved delineation between clustered satellites in a short window of time. The improved incorporation of utilizing owner operator provided ephemeris coupled with critical code improvements have now revolutionized how we maintain custody of earth orbiting objects. The exponential population growth of low-Earth orbiting satellites have also increased the quantity of Conjunction Data Messages sent out to partners such as the Trajectory Operations Group (TOPO) in Johnson Space Center. We will discuss the need for continued collaboration between the National Aeronautics and Space Administration (NASA) and other Mega-Constellation Satellite Operators to safeguard Human Space Flight operations. Lastly, we will discuss the increase in reentry reporting for satellites falling back to Earth’s atmosphere, and the challenges associated with these events.

Christian C Ramos↗

Crack Growth Rate and Large Plate Demonstration of Chloride-induced Stress Corrosion Cracking in Spent Nuclear Fuel Storage Canisters

This report describes the body of work involving testing and analyses performed in FY18 and FY19 at the Savannah River National Laboratory and at Korea University to determine chloride-induced stress corrosion crack (CISCC) growth rates in weldments of austenitic stainless steel plate material. The primary work involved: several separate crack growth rate test campaigns with new testing setups using laboratory-scale corrosion specimens; analyses to estimate the stress intensity factors for flaws postulated to be present in the residual stress fields of axial and circumferential weldments in a prototypic dry storage canister; and establishment of a “large plate” (approximately 51×46 cm with thickness 16 mm and weight about 30 kg) CISCC test that uses a plate with a circumferential weldment harvested from the Sandia National Laboratories’ full-size mockup dry storage canister. The tests for crack growth rate were conducted on ASTM E1861 bolt-load compact tension specimens in a setup designed to allow initially dried salt deposits to deliquesce and infuse the brine to the crack front under conditions relevant to the canister storage environments (e.g., temperature and humidity). The crack growth rate test results matched previous experimental data in the open literature. These literature data had been compiled by SNL and EPRI to develop a temperature-dependent (K-insensitive) crack growth rate model to support flaw disposition in the ASME Boiler and Pressure Vessel Section XI Code Case N-860, “Examination Requirements and Acceptance Standards for Spent Nuclear Fuel Storage and Transportation Containment Systems.” The knowledge of the salt, temperature, humidity conditions for CISCC including the threshold stress intensity factor, $K_{ISCC}$, were used to setup the large plate test in which a set of partthrough- wall and through-wall electrical discharge machined (EDM) defects were positioned in the weld residual stress field of the welded plate material from the mockup canister. A salt solution was applied to this plate specimen with an air-brush spray, then dried, and then exposed to a constant 75% RH condition at an ambient room temperature of 22 °C. The salt loading and environmental condition is expected to be aggressive to cause CISCC. The visual results at the surface of the plate show corrosion product staining (brown rust appearance) but with no CISCC emanating from the machined notches after approximately 5 months exposure to date. The plate test will continue in FY20 and phased-array ultrasonic testing and other NDE techniques will be applied to identify and characterize CISCC that may emanate from the machined defects. The notches and any CISCC from them will be sectioned at the conclusion of the test to verify NDE characterization, and to develop effective through-wall crack growth rates from cracks that would likely be branched.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Towards Predictive Plasma Science and Engineering through Revolutionary Multi-Scale Algorithms and Models (Final Report)

This report describes the high-level accomplishments from the Plasma Science and Engineering Grand Challenge LDRD at Sandia National Laboratories. The Laboratory has a need to demonstrate predictive capabilities to model plasma phenomena in order to rapidly accelerate engineering development in several mission areas. The purpose of this Grand Challenge LDRD was to advance the fundamental models, methods, and algorithms along with supporting electrode science foundation to enable a revolutionary shift towards predictive plasma engineering design principles. This project integrated the SNL knowledge base in computer science, plasma physics, materials science, applied mathematics, and relevant application engineering to establish new cross-laboratory collaborations on these topics. As an initial exemplar, this project focused efforts on improving multi-scale modeling capabilities that are utilized to predict the electrical power delivery on large-scale pulsed power accelerators. Specifically, this LDRD was structured into three primary research thrusts that, when integrated, enable complex simulations of these devices: (1) the exploration of multi-scale models describing the desorption of contaminants from pulsed power electrodes, (2) the development of improved algorithms and code technologies to treat the multi-physics phenomena required to predict device performance, and (3) the creation of a rigorous verification and validation infrastructure to evaluate the codes and models across a range of challenge problems. These components were integrated into initial demonstrations of the largest simulations of multi-level vacuum power flow completed to-date, executed on the leading HPC computing machines available in the NNSA complex today. These preliminary studies indicate relevant pulsed power engineering design simulations can now be completed in (of order) several days, a significant improvement over pre-LDRD levels of performance.

42 ENGINEERING↗

Navigating United States Standards and Regulation for Digital Energy Systems

This report provides an analysis of the U.S. standards and regulatory landscape for digital energy systems, focusing on cybersecurity, safety, and reliability requirements. It examines the interplay between federal mandates, state regulations, voluntary industry standards, and utility-specific policies, highlighting critical gaps between compliance and real-world risk mitigation. While NERC CIP standards enforce cybersecurity for Bulk Electric System assets, distribution-level infrastructure and emerging technologies often fall outside mandatory oversight, creating vulnerabilities. The report identifies systemic challenges such as reliance on self-attestation, uneven state adoption of safety codes, and lagging standards for advanced technologies like battery energy storage and inverter-based resources. Through a detailed gap analysis, it underscores the urgency of proactive risk-based approaches, independent verification, and strategic engagement with state and federal entities. Recommendations include adopting tiered security frameworks, strengthening procurement practices, and addressing emerging technology risks to ensure resilient and secure digital energy infrastructure. This guidance is intended for utilities, regulators, and stakeholders navigating compliance obligations and seeking to enhance cybersecurity and safety beyond minimum standards.

24 - POWER TRANSMISSION AND DISTRIBUTION↗

EAGLE-I Power Outage Data 2024

The provided EAGLE-I historic dataset includes power outage information at the county level for 2024 at 15-minute intervals collected by the EAGLE-I program at ORNL. The data has been collected from utility's public outage maps using an ETL process. The dataset details FIPS code, county name, state name, total number of customers without power, total customers per county, and a date/timestamp. For detailed metadata, refer to the linked metadata DOI.

24 POWER TRANSMISSION AND DISTRIBUTION↗

LES Simulation of Cooling Airflow of High-Pressure Turbine Using the Source Term Approach

In this study, the Open National Combustion code (OpenNCC) is applied to simulate the airflow inside the high-pressure turbine (HPT) of the energy efficient engine (EEE). The main objective of this study is to validate the proposed methodology of a three-dimensional unsteady calculation (LES) of the HPT with a moving mesh capability to capture a relative motion at the stator and rotor interface. In our previous study, the adiabatic wall assumption was made at all the solid surfaces of HPT (i.e., the cooling airflows were not included.) To relax this assumption, we implement the surface source team approach, in which we impose the source term at a specific area of a cooling airflow exit at the solid surfaces by specifying an injection angle, temperature, turbulent intensity, and mass flowrate of each cooling airflow. The beneficial feature of this approach is that it does not require a mesh for each hole. For the validation of the model, the data for EEE model is obtained from the General Electric (GE) test campaign, and the full scale warm-air rig test condition representing a test point close to the integrated core/low spool design condition is considered.

CFD Hot-streaks↗

Application of FARM to an IES scenario within the FORCE ecosystem

The FARM (Feasible Actuator Range Modifier) software module is a component of the RAVEN-based FORCE framework for analysis of Integrated Energy Systems (IES). FARM supports the HERON software module in the evaluation of the optimal dispatch by evaluating feasible set-points for the different IES unit components. Set-points are required to satisfy limits on both production variables (i.e., the variables to be optimized such as the electrical power, the hydrogen production rate, etc.) and process variables tied to the service life of equipment (e.g., steam flowrate, vessel pressure, turbine firing temperature, etc.). This problem is addressed by adopting a two-stage approach. First, the HERON power dispatcher determines set-points that meet the constraints on the former variables (e.g., power levels and power ramp rate limits). These constraints are called explicit constraints. Then, FARM adjusts these set-points to ensure the respect of the limits on the latter variables given the knowledge of the system physics acquired through machine learning algorithms. These constraints are called implicit constraints. From this standpoint, FARM constitutes a bridge between the HERON power dispatcher that adopts a simplified description of the IES unit (low-resolution physics) and the HYBRID high-fidelity models (high-resolution physics). The original version of the FARM software module (FARM-Alpha) was released by Argonne National Laboratory in January 2021. In the latest version of the code released in July 2022 (FARM-Delta), the Reference Governor (RG) algorithm was upgraded to a Multi-Input Multi-Output version from its original Single-Input Single-Output form. The RG algorithm acts to enforce constraints. With this improvement an IES unit is now treated as a single dynamic system from the standpoint of control. The crosstalk among components in an IES unit is now fully considered thereby ensuring a true optimization is obtained for those units that have multiple set-points. In this report, the capabilities of FARM-Delta operating within the FORCE ecosystem are demonstrated for an IES test case. The specific configuration of IES unit for this case was selected by the IES team with consultation from the Advanced Reactor IES Expert Group. A full TEA analysis that invoked HERON, HYBRID, FARM, and RAVEN was performed and serves to demonstrate how the latest modification to FARM algorithms (i.e., state variable selection, state-space matrices derivation, set-point verification) can shape setpoints that might otherwise compromise the health of equipment through accelerated wear and tear. In this specific test case, it was demonstrated that these algorithms ensure a more efficient utilization of steam resources to be shared by two different subsystems, namely Balance of Plant (BOP) and High-Temperature Steam Electrolysis (HTSE). Finally, some code improvements that can further enhance the user-friendliness are suggested.

97 MATHEMATICS AND COMPUTING↗

Numerical Investigation of the Effect of Cooling Airflow inside High-Pressure Turbine using the Source Term Approach

In this study, the Open National Combustion code (OpenNCC) is applied to simulate the airflow inside the high-pressure turbine (HPT) of the energy efficient engine (EEE). The main objective of this study is to compare the characteristics of the HPT performance obtained by using three different approaches (Case 1: the realistic combustion products are considered at the HPT inlet, but the cooling airflows are not included, Case 2: the working fluid is assumed to be a single gas (i.e., air), and the cooling airflows are considered, Case 3: the cooling airflow and the combustion products at the HPT inlet are included). To mimic the cooling airflows at the HPT surface, we use the surface source team approach, in which we impose the source term at a specific area of a cooling airflow hole at the solid surfaces by specifying an injection angle, temperature, turbulent intensity, and mass flowrate of each cooling airflow. For the validation of the model, the data for the EEE model was obtained from the General Electric (GE) test campaign (RDG10), and the full scale warm-air rig test condition representing a test point close to the integrated core/low spool design condition was considered. This validation test was done using the stationary uniform inflow condition (i.e., the reported total temperature and total pressure). Secondly, we considered the Sea-Level Take-off (SLTO) engine condition and separately performed the combustor simulation to obtain a more realistic time-averaged, spatially-nonuniform HPT inflow condition. This work provides a better understanding the effect of the cooling airflow model with different assumptions on the HPT performance. It is found that using different working gas have a minor effect on the performance metric, however the presence of the cooling airflows significantly affects the HPT performance such as the turbine efficiency.

CFD Hot-streaks↗

Analysis of Molten Salt Thermal Energy Storage Tank Sizing and Preheating

Molten Salt Thermal energy storage (TES) is essential for concentrating solar power (CSP) plants, enhancing their capacity factor and dispatchability to ultimately reduce electricity costs. This technology is becoming more important for other technologies including nuclear power, thermal-electrical storage, and concentrating solar thermal (CST). While molten salt TES tanks have been successfully deployed in lower-temperature parabolic-trough plants, the current state-of-the-art central receiver systems operating at temperatures up to 565 degrees Celsius have experienced costly and frequent failures. These failures are associated with the immaturity of the technology and problems in tank design, fabrication, commissioning and, sometimes, aggressive operation. A primary contributing factor is the absence of a dedicated technical standard for high-temperature molten nitrate TES tanks; designers must currently rely on existing codes like API 650 and ASME Section II, which are insufficient because they fail to account for the unique demands of high temperatures, thermal cycling, and transient conditions.

25 ENERGY STORAGE↗

Computer model to simulate testing at the National Transonic Facility

A computer model has been developed to simulate the processes involved in the operation of the National Transonic Facility (NTF), a large cryogenic wind tunnel at the Langley Research Center. The simulation was verified by comparing the simulated results with previously acquired data from three experimental wind tunnel test programs in the NTF. The comparisons suggest that the computer model simulates reasonably well the processes that determine the liquid nitrogen (LN2) consumption, electrical consumption, fan-on time, and the test time required to complete a test plan at the NTF. From these limited comparisons, it appears that the results from the simulation model are generally within about 10 percent of the actual NTF test results. The use of actual data acquisition times in the simulation produced better estimates of the LN2 usage, as expected. Additional comparisons are needed to refine the model constants. The model will typically produce optimistic results since the times and rates included in the model are typically the optimum values. Any deviation from the optimum values will lead to longer times or increased LN2 and electrical consumption for the proposed test plan. Computer code operating instructions and listings of sample input and output files have been included.

Mineck, Raymond E.↗

Radiative strength functions from the energy-localized Brink-Axel hypothesis

Radiative strength functions (RSFs) model the bulk electromagnetic response of highly excited nuclei and are critical inputs for statistical reaction codes. In this paper, we present a definition of the RSF that is consistent with Hauser-Feshbach reaction codes and that can be efficiently computed with the shell model using the Lanczos strength-function (LSF) method. Here, we introduce a variant of the shell-model LSF method that exploits the energy-localized Brink-Axel hypothesis, which makes it possible to compute both electric and magnetic RSFs across all energies relevant to capture reactions. We verify agreement with the conventional definition of RSFs with benchmark calculations of 24 Mg and then present novel results for 56 Fe. For 56 Fe we find that (i) the 𝑀⁢1 RSF shape evolves smoothly with excitation energy, consistent with the energy-localized Brink-Axel hypothesis; (ii) both 𝑀⁢1 and 𝐸⁢1 transitions contribute significantly to the radiative strength below the photoabsorption threshold; and (iii) within the sdpf model space, the strength below 3 MeV observed in Oslo-type experiments cannot be fully reproduced. These results pave the way for a coherent microscopic description of RSFs and further motivate the use of energy-dependent RSFs in modern reaction codes.

Physics - Nuclear physics and radiation physics↗

Workbooks for Cambium 2024 Data

These workbooks contain a subset of cost and emissions data from the 2024 Cambium datasets, with levelization calculations to assist users in translating Cambium’s year-over-year values to a representative value for a user-specified project timeline. These workbooks provide modeled data for 18 GEA regions covering the contiguous United States, projected forward through 2050. Mappings of these regions to ZIP codes and counties is given within this workbook in the corresponding tabs. For the full Cambium 2024 data sets, see the Cambium 2024 project on NREL's Scenario Viewer. For more details on input assumptions and methodology see the associated report: Cambium 2024 Scenario Descriptions and Documentation. Users are advised to review section 4 of the report, which discusses limitations and caveats of the data. This data is planned to be updated annually. Information on the latest versions can be found on the NREL energy analysis page on Cambium.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Understanding the Costs and Barriers of Residential Electrical Panel and Service Upgrades

Upgrading electrical panels and services in U.S. homes represents a significant barrier to building modernization, imposing considerable costs, delays, and procedural uncertainties on homeowners, contractors, utilities, and building departments. Although cost databases document individual infrastructure activities, they rarely capture the integrated, whole-project perspective required to understand how electrical upgrades are planned, executed, and regulated. Existing research is often geographically constrained, narrowly scoped, or derived from limited samples, leaving significant knowledge gaps unaddressed. This study examines the timelines and costs associated with residential electrical panel and service upgrades using data from a national cross- sectional survey conducted in summer 2025. The survey captured responses from 140 stakeholders across 34 states, including building industry professionals, utility staff, and building department staff. Findings indicate that project duration and cost increase substantially with building size though patterns vary by infrastructure type. Most single-family and small multifamily projects were completed within 30 days, whereas medium and large multifamily buildings show longer and less predictable timelines. Service rating increases modestly extend project duration, but building type and size were the primary determinants of delays. Cost patterns were similar: customer-side equipment and panel replacements scale predictably with building size, while utility-side costs are highly variable, often triggered by threshold-driven infrastructure upgrades such as transformer replacements. Permit fees vary considerably between jurisdictions but generally represent a minor proportion of total project costs. These findings identify electrical upgrades as a significant barrier to residential building costs and highlight the need for improved stakeholder coordination, streamlined permitting, and strategies that reduce upgrade requirements while maintaining safety and code compliance.

Casquero-Modrego, Nuria↗

Residential Building Energy Efficiency Field Studies: Low-Rise Multifamily

In recent years, the U.S. Department of Energy (DOE) has conducted a series of research studies to validate energy efficient building technologies in the field. Much of the work has focused on single-family construction, and some has also addressed commercial energy codes. The work detailed in this DOE-funded study (EE0007616) focuses on low-rise multifamily buildings (three stories or fewer above grade) in various regions of the United States, and reports on how state-level building codes are being implemented, both in terms of observed characteristics and also in terms of estimated energy impacts. Nearly 100 buildings across four states—Illinois, Minnesota, Oregon, and Washington—were sampled, which represent a range of climate types from mild temperature to very cold continental. Both common entry and outdoor entry buildings were included, and a parallel research project evaluated envelope air tightness and current still-evolving air tightness testing methods. Finally, a set of structured interviews of building designers and other relevant professionals was carried to out to gain more insight into this market. To the greatest extent possible, the methodology developed under the project for low-rise multifamily buildings mirrored the approach established by Pacific Northwest National Laboratory (PNNL) for single-family residential buildings (https://www.energy.gov/eere/buildings/downloads/residential-building-energy-code-field-study). This included the general approach to sampling, recruitment, and data collection, as well as data analysis and presentation. The range of permitting dates for the sites encompassed two energy code cycles in most regions. All states in the study had adopted a variation of the International Energy Conservation Code (IECC) for the structure of their state code. The low-rise multifamily occupancy presents a hybrid building type: most of the building’s conditioned floor area was covered by the residential chapter of the code while portions of the building (such as corridors and common spaces) fell under the commercial code chapter. The key items assessed in this work were: Building Shell—exterior wall insulation, ceiling insulation, foundation insulation, windows. Common Areas—HVAC and lighting. Living Units—lighting, ventilation. A few items were not assessed in detail, given their relative paucity in this occupancy type; these included duct leakage, pipe insulation, and hot water circulation controls. Building characteristics were collected via a combination of architectural, mechanical, electrical, and plumbing plan reviews and field inspections, and entered into a spreadsheet-based tool that was later queried to build a database. Data went through quality control both upon arrival and via a later semi-automated review and assurance process. Most of the data are presented graphically so that the reader can quickly assess compliance with the applicable energy codes (both by state and by code year). As a final step, EnergyPlus™ simulations were created for all buildings in the study to estimate both the as-found energy use intensity (EUI) and the energy and CO 2 that could be saved if features that were found to not meet code minimums were brought up to code. The savings estimates were tabulated for each of the four states in the study. The research team found that the single-family approach was largely applicable to low-rise multifamily buildings. This applies to both the data collection and the prototype EUI analysis. Most of the occupied space is living units and falls under residential energy codes, and many characteristics use similar envelope construction and relatively straightforward mechanical systems and lighting. One of the most challenging aspects of this work was to build an effective spreadsheet-based data collection instrument that could allow efficient collection of both building plan and field data. The research team is of the view that other methods could be equally effective if the work is done carefully with diligent quality control. The primary findings for the work center around the thermal envelope and mechanical systems and lighting at the sites: For thermal envelope components, the majority of buildings met or were better than the prescriptive code.This suggests that building designers and builders are aware of code requirements. In some cases, surveyed buildings were designed to qualify for energy efficiency certification programs. These buildings made up at least 20% of sampled buildings in each state. Almost all buildings met mechanical system efficiency requirements (for both living units and common areas). In some cases, sites employed systems that were considerably more efficient than required by the applicable energy code. Dwelling units had a majority of high-efficacy lighting, often in excess of the state’s residential code requirements. While high-efficacy fixtures were also typical in common areas (corridors and stairwells), lighting power densities (LPDs) in these areas were sometimes higher than levels dictated by the applicable part of the state commercial energy code. The simulation models run on a series of low-rise multifamily prototypes, informed by a composite of the field data collected, calculated annual EUIs of between 20 and 50 kBtu/ft2-yr, with the range representing the effects of both building characteristics and building location (climate zone). A detailed process (based on simulations of prototype buildings) was used to estimate the amount of avoided energy use that would occur if 100% adherence to energy codes were attained. The results indicated modest savings are attainable for items such as window thermal performance and common area lighting. The result is overall only a modest potential for additional energy savings, averaging about 10% of EUI.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Out-of-Pile Testing and Instrumentation Transient Water Irradiation System

Current initiatives to increase the burnup of conventional nuclear fuels past the approximate 62 GWd/t limit have been spurred on by direct savings to refueling and waste storage. The technical justification for a new license limit requires extensive qualification through experimental testing. Unlike beginning-of-life fuels, high-burnup fuels are more susceptible to fuel fragmentation, relocation, and dispersal (FFRD), therefore more data is needed to characterize fuels under key accident scenarios. The Transient Reactor Test Facility (TREAT) located at the Idaho National Laboratory has developed a testing apparatus architecture to test fuels and claddings at prototypic conditions. The Transient Water Irradiation System (TWIST) is the latest iteration of a testing device capable of conducting loss of coolant accidents (LOCAs) in TREAT. The Out-of-Pile Testing and Instrumentation TWIST (OPTI-TWIST) is an electrically heated device that is analogous to TWIST. OPTI-TWIST allows for detailed instrumentation and thermal-hydraulic characterization. TWIST ultimately aims to conduct the most advanced in-situ diagnostics to evaluate FFRD in a prototypic LOCA. Moreover, it will explore the phenomenological bifurcation of a decay-energy heat up driven LOCA and a stored-energy heat up driven LOCA. The instrumentation suite includes conventional thermocouples and pressure transducers in addition to an electro impedance sensor, an acoustic emission sensor, an optical pressure sensor, and an optical pyrometer. Characterizing these instruments in OPTI-TWIST eliminates complications of irradiation effects while preserving extreme thermal-hydraulic conditions. Finally, benchmarking both devices to a thermal-hydraulic code like the Reactor Excursion and Leak Analysis Program (RELAP)5-3D provides a unique opportunity for iteration. Pre-test predictions and post-test interpretations inform the physical designs, operational procedures, test conditions, and instrumentation types and positions.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

FORCE Regression Testing

Via programs including the Light Water Reactor Sustainability and Integrated Energy Systems, the U.S. Department of Energy has invested in the Framework for Optimization of ResourCes and Economics (FORCE) software framework (Idaho National Laboratory 2024a) for the technical and economic analysis of nuclear-integrated energy systems (IES). Nuclear IES expand the use of nuclear from traditional baseload electricity generation to a flexible and adaptive source of combined heat and power. Nuclear heat can be used in the production of a variety of energy currencies such as hydrogen and ammonia as well as other heat applications including water desalination and district heating. FORCE is designed with the intent to provide interconnected analysis tools that enable the accurate technical and economic assessment of specific nuclear IES configurations for individual energy markets. FORCE consists of three main analysis pathways: HYBRID (Idaho National Laboratory 2024b), which contains high-resolution physical models for IES; Holistic Energy Resource Optimization Network (HERON) (Idaho National Laboratory 2024c), which analyzes IES long-term economic viability; and Optimization of Real-time Capacity Allocation (ORCA) (Idaho National Laboratory 2024d), designed for real-time control of IES via digital twins and optimal decision making, including autonomous and remote operation research. Development of the FORCE ecosystem is guided by three pillars: capability, which assures that the computational requirements of IES analysis are met by the software tools; reliability, which provides for consistent code performance and expected behaviors; and accessibility, which lowers the barrier to entry for using the software and accelerates analysis by users beyond the FORCE primary developers. Reliability of the FORCE ecosystem is established according to the American Nuclear Society?s Nuclear Quality Assurance (NQA-1) program [American Society of Mechanical Engineers 1982], with specific levels of software quality assurance (SQA) within NQA-1 applied to each software tool in FORCE. As the tools within FORCE have matured, some integration algorithms to accurately connect the software tools for holistic analysis have been developed and deployed within the FORCE software repository. In accordance with NQA-1 standards, regression tests are required to guarantee the software performs consistently even when new capabilities are added to the software. In this report, we document the deployment of both unit tests, which test the consistent behavior of small pieces of the FORCE code base, as well as integration tests, which test the consistent performance of full use cases for the FORCE integration algorithms. We further document the encapsulation of these tests within a test harness, which collectively checks for each successful test completion on demand. Finally, we document the automation of the test harness using GitHub Actions [GitHub 2024], which require all tests succeed before any new capability or other changes can be added to the FORCE integration software

97 MATHEMATICS AND COMPUTING↗

GridSTIX

SF-25-112 Grid-STIX is a comprehensive extension of the STIX (Structured Threat Information Expression) 2.1 ontology specifically designed for electrical grid cybersecurity applications. This ontology provides a standardized, machine-readable framework for modeling grid assets, operational technology devices, threats, vulnerabilities, supply chain risks, and security relationships in electrical power systems. ## Key Features - **Comprehensive Grid Coverage**: Physical assets, OT devices, grid components, sensors, and energy storage systems - **Zero Trust Architecture**: Policy decision points, enforcement points, trust brokers, and continuous monitoring - **AMI Infrastructure**: Advanced metering networks, head-end systems, mesh gateways, and MDM systems - **Advanced Security Modeling**: Attack patterns, vulnerabilities, mitigations, and supply chain risks - **Critical Grid Relationships**: Power flow, protection, control, and synchronization relationships - **Supply Chain Security**: Supplier modeling, country of origin tracking, and risk assessment - **Protocol Support**: DNP3, Modbus, IEC 61850, IEC 60870-5-104, OPC-UA, and IEEE standards - **Python Code Generation**: Automated STIX-compliant Python class generation from ontologies - **Interactive Visualization**: Enhanced HTML network graphs with grid-specific categorization - **STIX 2.1 Compliance**: Full compatibility with STIX threat intelligence ecosystem

Blakely, Benjamin [Argonne National Laboratory (AN↗