Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “NaI”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Solar flare X-ray polarimeter utilizing a large area thin beryllium scattering disk

A model of a solar flare X-ray polarimeter utilizing a large-area thin beryllium scattering disk was developed using Monte Carlo techniques for several classes of solar flares. The solar-flare polarimeter consists of a 30-cm-diam Be disk of about 1/3 of a scattering length thickness, which is surrounded by a cylindrical detector composed of six segmented panels of NaI scintillators, each coupled to 15 photomultiplier tubes. The instrument is sensitive to X-rays from 10 to 100 keV. For a class-M-2 solar flare observed for 10 sec from a balloon at an altitude of 150,000 ft, the minimum detectable polarization at the 99 percent statistical confidence level was found to be 1-6 percent over the energy range 20-100 keV.

Gotthelf, E.↗

The EGRET high energy gamma ray telescope

The Energetic Gamma Ray Experiment Telescope (EGRET) on the Compton Gamma Ray Observatory (GRO) is sensitive in the energy range from about 20 MeV to about 30,000 MeV. Electron-positron pair production by incident gamma photons is utilized as the detection mechanism. The pair production occurs in tantalum foils interleaved with the layers of a digital spark chamber system; the spark chamber records the tracks of the electron and positron, allowing the reconstruction of the arrival direction of the gamma ray. If there is no signal from the charged particle anticoincidence detector which surrounds the upper part of the detector, the spark chamber array is triggered by two hodoscopes of plastic scintillators. A time of flight requirement is included to reject events moving backward through the telescope. The energy of the gamma ray is primarily determined by absorption of the energies of the electron and positron in a 20 cm deep NaI(Tl) scintillator.

Hartman, R. C.↗

Further high-resolution Na I observations of the local interstellar medium

High-resolution absorption measurements of the interstellar Na I D lines at 5890 A observed toward 27 early-type stars in the local interstellar medium (LISM) are presented. These results are combined with other high-resolution sodium measurements to map the space distribution of neutral sodium column density for some 118 stars out to less than 200 pc. These measurements indicate an upper limit to the neutral sodium column density of log N(Na I) less than 10.0/sq cm can be inferred out to a distance of 50 pc in most directions in the LISM. Also, the rarefield region of the Local Bubble may extend beyond 60 pc in at least 35 percent of the directions sampled thus far. Evidence is shown for a ubiquitous, comoving vector for neutral NaI gas clouds in the LISM which is in a different direction to LISM vectors previously reported for more ionized local gas clouds. A comparison of the measured sodium columns with those of interstellar Ca II for a sample of 12 stars within 95 pc results in a ratio of Na I/Ca II less than 0.5 for most stars. This value implies that there could be warm, neutral gas with T of about 12,500 K beyond 50 pc in the LISM.

Welsh, B. Y.↗

Application of neutron interrogation techniques to corrosion detection

This paper discusses a technique which may be able to detect corrosion by determining the presence of oxygen at the corroded site via a neutron inelastic gamma reaction. Initial experiments have been performed using a Pu-239/Be neutron source and a NaI(T1) gamma-ray detector. From the results it was concluded that a 1 mm thickness of aluminum oxide would not be detected.

Birt, E. A.↗

Correlated optical observations with BATSE/CGRO on SCO X-1

The Burst and Transient Source Experiment (BATSE) instrument on the Compton Gamma-Ray Observatory consists of two banks of eight instruments referred to as the Large Area Detectors (LADs) and the Spectroscopic Detectors (SDs). Each LAD crystal is 50.8 cm in diameter by 1.27 cm thick while for a SD these values are 12.7 cm in diameter by 7.62 cm in diameter. Both the LADs and SDs are NaI(TI) scintillation detectors. The LADs and SDs are situated on the CGRO spacecraft so as to provide all sky coverage for both sets of detectors. The SDs have the ability to measure energies in the 8-16 keV range whereas the minimum energy at which the LADs operate is near 20 keV. SCO X-1 is the brightest continuous x-ray source in the sky. It is believed to consist of a low mass star orbiting and transferring mass onto a neutron star. It is representative of a class of similar objects referred to as low mass x-ray binaries (LMXB). Because SCO X-1 serves as the prototype of this class of x-ray emitters and since its detectable emission is so large, it warrants extended study. One of the most fruitful techniques of studying a LMXB system is by simultaneously monitoring its emission at a variety of different wavelengths. These correlated datasets can be used to probe the source environment, investigate emission mechanisms, and examine the mass transfer process itself. In principle, the BATSE SDs have the capability of providing a nearly continuous 8-16 keV record of SCO X-1 activity. The aim of this study was to investigate the feasibility of using the BATSE SDs along with simultaneous optical measurements to study this source.

Mcnamara, Bernard↗

Performance of HEXTE engineering model phoswich detectors

The preliminary design for the 15-250 keV, 200/sq cm, phoswich detectors for the High Energy X-ray Timing Experiment for NASA's X-ray Timing Explorer mission has been completed, and the first engineering model has been fabricated. This unit has undergone extensive environmental and performance testing, including extended vibration, thermal range, resolution, uniformity, and pulse shape, and is within specifications for all tests. Broad beam energy resolution of better than 15 percent at 60 keV and clear separation of NaI and CsI pulse shape peaks are seen. The design and test results will be presented.

Hink, Paul↗

Results from a Si(Li) gamma ray detector stack for future Mars missions

We present Monte Carlo analysis and experimental data from a novel lithium-drifted silicon detector stack for gamma ray spectroscopy instrumentation in future Mars surface landers and other planetary missions. The Monte Carlo analysis shows full energy photopeaks even in the range of about 100 keV to 2 MeV where, in Si, Compton scattering dominates the absorption processes. Laboratory data is shown for an experimental detector stack of four planar Si(Li) devices, each 5 mm thick with an active area 2 cm in diameter. All the experimental data were collected with maximum temperature of the stack at 175 K. Background reduction is achieved by using the detector of the stack closest to the source in anticoincidence. We present a comparison of experimental data from the stack with the Monte Carlo model for Cs-137 (662 keV). Agreement is shown to be good, with a full energy photopeak clearly seen (FWHM about 10 keV). Experimental stack data is also shown for multiple peaks at 511 keV (Na-22) and 662 keV (Cs-137). The peaks are clearly resolved (FWHM 10 keV), and are compared with the results obtained using a 8 percent resolution, 3 in. x 3 in. NaI(TI) device (FWHM about 50 keV).

Hubbard, G. S.↗

The Oriented Scintillation Spectrometer Experiment - Instrument description

The Oriented Scintillation Spectrometer Experiment on the Arthur Holly Compton Gamma Ray Observatory satellite uses four actively shielded NaI (Tl)-CsI(Na) phoswich detectors to provide gamma-ray line and continuum detection capability in the 0.05-10 MeV energy range. The instrument includes secondary capabilities for gamma-ray and neutron detection between 10 and 250 MeV. The detectors have 3.8 deg x 11.04 deg (FWHM) fields of view defined by tungsten collimators. Each detector has an independent, single-axis orientation system which permits offset pointing from the spacecraft Z-axis for background measurements and multitarget observations. The instrument, and its calibration and performance, are described.

Johnson, W. N.↗

BATSE's sky sensitivity map

The Burst and Transient Source Experiment (BATSE) detects any gamma-ray burst not obscured by the earth and intense enough to produce a sufficiently strong signal in at least two of its eight large area NaI detectors (LADs). For a given intensity, a LAD records a stronger signal from a source which directly faces it than from a source to its side. Thus, BATSE's detection of a gamma-ray burst may depend upon the burst's direction. We discuss the effect of this uneven exposure to the sky on the instrument's measurement of the distribution of gamma-ray burst directions and intensities, and we describe our method of accounting for the effect.

Brock, M. N.↗

Cosmic and solar gamma ray and neutron experiments

This report summarizes the results of the research supported by NASA grant NAGW-2734 and lists the papers and publications produced through the grant. The basic goal of the work was to complete analysis of data from exposure of a large NaI scintillation detector to fast neutrons and to disseminate the results of the analysis. A secondary goal was to compare the measured detector response to neutrons with Monte Carlo calculations of the response. In Section 2.0, we discuss the goals of the research. In Section 3.0, we summarize the results of the research. In Section 4.0, we list the papers and publications produced under the grant. Preprints or reprints of the publications are attached as appendices.

Dunphy, Philip P.↗

X-ray spectroscopy with silicon pin and avalanche photo diodes

Results of an evaluation of silicon P-Intrinsic-N (PIN) photodiodes and Avalanche Photodiodes (APD) for the direct detection of soft x rays from 1 to 20 keV and for the detection of scintillation light output from CsI(TI) for higher x ray energies (30 to 1000 keV) are presented. About one keV resolution was achieved at room temperature for both the PIN and APD detectors for soft x rays (1 to 20 keV). Commercially available, low power (18 mV), low noise, hybrid preamplifiers, were used. These photodiodes were also coupled to CsI(TI) scintillator and obtained about 6 resolution at 662 keV. The photodiode frequency response matches well with the emission spectrum of the CsI(TI) scintillator providing good spectral resolution and a higher signal than NaI(TI) when viewed by conventional photomultipliers. A PIN-CsI(TI) combination provides a low energy threshold of around 60 keV while for the APD-CsI(TI) it is 15 keV.

Desai, U. D.↗

Neutral gas and diffuse interstellar bands in the LMC

Tracing the dynamics of the neutral gas and observing diffuse interstellar bands in the LMC (Large Magellanic Cloud) was the focus of this study. The S/N values, a Quartz lamp exposure, a T horium Argon Comparision lamp exposure, and spectral plots for each star observed were taken. The stars observed were selected to sample the 30 Dor vicinty. NaI absorption profiles are included.

Danks, Anthony C.↗

The Response of the BATSE LADs to Radiation From the Crab Nebula and Plans for Radioactivity Studies on Space Station

The Burst And Transient Source Experiment (BATSE) onboard the Compton Gamma-Ray Observatory (CGRO) was designed to measure X-rays and gamma rays with energies from about 50 keV to above 2 MeV. As with many scientific investigations, the success of the original experiment lead to additional areas of research interest. In the case of BATSE the ability to observe the radiation from sources down to about 20 keV became readily apparent. This lead to a continuing program of measuring the spectrum of radiation from stellar objects at these lower energies. One of these, the Crab Nebula, has a very steady radiation flux and, thus, has become a "standard candle" for such measurements. The Large Area Detectors (LADS) on BATSE contain a 1.27-cm thick, 25.4-cm radius NaI(Tl) detector behind a 6.35-mm thick polystyrene Charged Particle Detector (CPD) used to "veto" charged particles signals. The detectors have been calibrated with a series of gamma and X-ray sources and the results carefully simulated with a Monte Carlo code. In the calibration process the computer simulation accounts for scattering from material in the counting room as well as the BATSE structure. For an orbiting detector, scattering from the entire spacecraft must be modeled as well as for all covering material over the detectors. Five years after CGRO was launched on April 5, 1991, a large body of observational data has been taken of the Crab Nebula. The technique used for these observations, and for many other X-ray sources, is Earth occultation. From the perspective of the spacecraft, the Earth occults most stellar objects once in orbit, i.e., the signal is lost as the source sets and is regained as the source rises. A careful analysis of the continuing signals from all sources measured allows for an accurate measurement of the spectrum of a given source. An analysis of this data from the Crab has indicated that the LADs are very responsive at energies as low as 20 keV-at energies below the range of calibration. While the model accounts for many of the interactions of the photons with the detectors, the observation of nonstatistical deviations at low energy and at small angles has suggested a need to recalibrate at energies where the attenuation effects are increasing exponentially.

Laird, C. E.↗

Experimental Results of the 2.7% Reference H Nacelle Airframe Interference High Speed Civil Transport Model

Experiments were conducted in the NASA Ames 9-Ft by 7-Ft Supersonic and 11-Ft by 11-Ft Transonic Wind Tunnels of a 2.7% Reference H (Ref. H) Nacelle Airframe Interference (NAI) High Speed Civil Transport (HSCT) model. NASA Ames did the experiment with the cooperation and assistance of Boeing and McDonnell Douglas. The Ref. H geometry was designed by Boeing. The model was built and tested by NASA under a license agreement with Boeing. Detailed forces and pressures of individual components of the configuration were obtained to assess nacelle airframe interference through the transonic and supersonic flight regime. The test apparatus was capable of measuring forces and pressures of the Wing body (WB) and nacelles. Axisymmetric and 2-D inlet nacelles were tested with the WB in both the in-proximity and captive mode. The in-proximity nacelles were mounted to a nacelle support system apparatus and were individually positioned. The right hand nacelles were force instrumented with flow through strain-gauged balances and the left hand nacelles were pressure instrumented. Mass flow ratio was varied to get steady state inlet unstart data. In addition, supersonic spillage data was taken by testing the 2-D inlet nacelles with ramps and the axisymmetric inlet nacelles with an inlet centerbody for the Mach condition of interest. The captive nacelles, both axisymmetric and 2-D, were attached to the WB via diverters. The captive 2-D inlet nacelle was also tested with ramps to get supersonic spillage data. Boeing analyzed the data and showed a drag penalty of four drag counts for the 2-D compared with the axisymmetric inlet nacelle. Two of the four counts were attributable to the external bevel designed into the 2-D inlet contour. Boeing and McDonnell Douglas used these data for evaluating Computational Fluid Dynamic (CFD) codes and for evaluation of nacelle airframe integration problems and solutions.

Cappuccio, Gelsomina↗

The Glast Burst Monitor

The Gamma-Ray Large Area Space Telescope (GLAST) will include a secondary instrument to augment the observatory's capabilities for GRB studies. The GLAST Burst Monitor (GBK is a collaboration between Marshall Space Flight Center, the University of Huntsville, Alabama, and the Max Plank Institute for Extraterrestrial Physics. The purpose of the GBM is to extend energy coverage below the main instrument's lower limit of about 20 MeV, and to provide an on-board burst trigger and approximate location. The instrument consists of twelve NaI detectors and two BGO detectors. This combination provides energy coverage from a few keV up to about 30 MeV.

Meegan, Charles↗

Optical and Atomic Force Microscopy Characterization of PbI2 Quantum Dots

Lead iodide (PbI2) clusters were synthesized from the chemical reaction of NaI (or KI) with Pb(NO3)2 in H2O, D2O, CH3OH, and C3H7OH media. The observation of the absorption features above 350 nm with the help of integrating sphere accessory strongly suggests the quantum dot formation of PbI2 in solution. Spectral comparison between the synthesized PbI2 clusters in solution and PbI2 nanophase by impregnation of PbI2 in four different pore-sized porous silica indicates that the PbI2 cluster size in solution is less than 2.5 nm in lateral dimension. Atomic force microscopy (AFM) measurements show that the PbL clusters deposited onto three different molecularly flat surfaces are single-layered. The measured height is 1.0 - 0.1 nm. The swollen layer thickness can be attributed to the intralayer contraction from the strong lateral interaction among PbI2 molecules, which is supported by ab initio calculation. Raman scattering measurement of LO and TO modes of PbI2 in bulk and in the confined state were also conducted in 50-150 cu cm region. The observed three bands at 74, %, 106 1/cm are assigned to TO2, LO2, and LO, mode, respectively. The relatively small red-shift in LO modes may be caused by the surface phonon polaritons of PbI2 nanophase in the porous silica.

Mu, R.↗

The GLAST Burst Monitor

The GLAST Burst Monitor The Gamma Ray Large Area Space Telescope, scheduled for launch in 2006, comprises a Large Area Telescope (LAT) and a GLAST Burst Monitor (GBM). The LAT is a pair telescope with unprecedented sensitivity in the 20 Mev to 300 GeV energy range. The GLAST Burst Monitor (GBM) consists of an array of NaI and BGO scintillation detectors operating in the 10 kev to 30 MeV range and covering a wide field of view. The GBM will enhance LAT observations of GRBs by extending the spectral coverage into the range of current GRB databases, and will provide a trigger for re-orienting the spacecraft to observe delayed emission from bursts outside the LAT field of view.

Meegan, C. A.↗

Lipid Biomarkers for Methanogens in Hypersaline Cyanobacterial Mats for Guerrero Negro, Baja California Sur

Analyses of sediments from the vicinity of active methane seeps have uncovered a particular suite of lipid biomarker patterns that characterize methane consuming archaea and their syntrophic, sulfate reducing partners. These isoprenoid biomarkers, largely identified by their anomalously light carbon isotopic signatures, have been a topic of intense research activity and are recorded in numerous methane-rich environments from Holocene to Cenozoic. This phenomenon has implications for depleted kerogens at 2.7 Ga on early Earth (Hinrichs 2002). In contrast, the lipid biosignatures of methane producing archaea are not readily identified through distinct isotopic labels and have received comparably little attention in analyses of archaea in environmental samples. Indeed, environmental analyses generally detect only free archaeal lipids, not the intact, polar molecules found in the membrane of living organisms. As part of the Ames NAI, the 'Early Microbial Ecosystem Research Group' (EMERG) is working to understand microbial processes in the hypersaline cyanobacterial mats growing in the salt evaporation ponds of the Exportadora de Sal at Guerrero Negro, Baja California Sur, Mexico. The aim of this study was to develop methods by which we could identify the organisms responsible for methane generation in this environment. While the ester-bound fatty acids, hopanoids and wax esters provide a means to identify most of the bacterial components of these mats, the archaea which Ere evidently present through genomic assays and the fact of intense methane production (Hoehler et al. 200l), have not been identified through their corresponding lipid signatures. Archaeal core lipids present a number of analytical challenges. The core lipids of methanogens comprise C20, C40 and sometimes C25 isoprenoid chains, linked through ether bonds to glycerol. As well as archaeal (C20), sn-2- and sn-3-hydroxyarchaeol are associated particularly with methylotrophic methanogens. Recently, we have also identified a dihydroxyarchaeol in a hyperthermophilic methanogen (Summons et al. 2002). Additional structural diversity is encoded into the polar head groups that are attached to the glycerol ether cores. The C20 core lipids are readily analyzed by GC-MS as their volatile trimethylsilyl derivatives while compounds with intact polar head groups can only be detected using LC-MS approaches. Our approach was to utilize the alternative of an ether cleavage reagent (BBr3 vs. HI) and a hydride reducing agent to convert all ether lipids to hydrocarbon in order to provide a vertical profile of quantitative information that might be matched to methane fluxes. We have found that while conventional acid hydrolysis and HI treatment will destroy hydroxyarchaeols, molecular information remains intact through use of BBr3 for ether cleavage. This method revealed the presence of traces of biphytane and various ether alkyls associated with some sulfate reducing bacteria within the mat structure. An interesting, and potentially valuable, byproduct of the method utilizing HI was the identification of abundant homohopanoids after superhydride reduction. Evidently present as sulfur-bound diagenetic products these hopanoids are likely cyanobacterial biomarkers in the early stages of diagenetic preservation.

Jahnke, Linda L.↗