Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Monte Carlo method.”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Modelling of radiative transfer by the Monte Carlo method and solving the inverse problem based on a genetic algorithm according to experimental results of aerosol sensing on short paths using a femtosecond laser source

We consider the algorithms that implement a broadband ('multiwave') radiative transfer with allowance for multiple (aerosol) scattering and absorption by main atmospheric gases. In the spectral range of 0.6 – 1 μm, a closed numerical simulation of modifications of the supercontinuum component of a probing femtosecond pulse is performed. In the framework of the algorithms for solving the inverse atmospheric-optics problems with the help of a genetic algorithm, we give an interpretation of the experimental backscattered spectrum of the supercontinuum. An adequate reconstruction of the distribution mode for the particles of artificial aerosol with the narrow-modal distributions in a size range of 0.5 – 2 mm and a step of 0.5 mm is obtained. (light scattering)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

TU-F-BRE-06: Flattening-Filter-Free Beam Quality Correction Factor Determination Using Experimental and Monte Carlo Methods

Purpose: To investigate beam quality correction factors for the flattening-filter-free (FFF) energies of the TrueBeam™ accelerator based on a dosimetry formalism for small and nonstandard fields. Methods: Three detectors - an Exradin W1 scintillator, Sun Nuclear EDGE diode, and LiF(Mg,Tl) TLD-100 chips - were investigated to determine their applicability as tools to measure quality correction factors for ionization chambers in the small and nonstandard fields of the TrueBeam™. Volume-averaging effects and energy dependence were observed in fields ranging from 1×1 to 40×40 cm{sup 2} for 6 MV and 10 MV beam energies using both FFF and flattened beam modes. Correction factors were determined for three ionization chambers: an Exradin A12 Farmer-type chamber, an Exradin A1SL scanning chamber, and an Exradin A26 reference-class microchamber. Beam quality corrections were also obtained using a benchmarked model of the TrueBeam™ created with the BEAMnrc user code of EGSnrc. Results: All three detectors demonstrated measureable energy dependence in the megavoltage range. The EDGE diode was deemed the most appropriate tool for beam quality correction factor measurements due to its low energy dependence and small size; however, alanine will be used in the future to reduce energy dependent effects even further. Measured k{sub Qmsr,Q} corrections of up to 4% were found for the 6MV FFF and 10 MV FFF beams, corresponding to a discrepancy of up to 3% compared to TG-51-determined dose. Up to a 10% k{sub Qclin,Qmsr} correction was measured for small fields referenced to a 10×10 cm{sup 2} field of the same energy. Much larger corrections were determined using the Monte Carlo model, and these discrepancies require further investigation. Conclusion: Progress has been made toward determining beam quality correction factors for the small and nonstandard fields of the TrueBeam™ accelerator. Further work must be done to ensure greater accuracy in patient treatments with this new modality.

07 ISOTOPE AND RADIATION SOURCES↗

SU-C-201-06: Small Field Correction Factors for the MicroDiamond Detector in the Gamma Knife-Model C Derived Using Monte Carlo Methods

Purpose: To determine small field correction factors for PTW’s microDiamond detector in Elekta’s Gamma Knife Model-C unit. These factors allow the microDiamond to be used in QA measurements of output factors in the Gamma Knife Model-C; additionally, the results also contribute to the discussion on the water equivalence of the relatively-new microDiamond detector and its overall effectiveness in small field applications. Methods: The small field correction factors were calculated as k correction factors according to the Alfonso formalism. An MC model of the Gamma Knife and microDiamond was built with the EGSnrc code system, using BEAMnrc and DOSRZnrc user codes. Validation of the model was accomplished by simulating field output factors and measurement ratios for an available ABS plastic phantom and then comparing simulated results to film measurements, detector measurements, and treatment planning system (TPS) data. Once validated, the final k factors were determined by applying the model to a more waterlike solid water phantom. Results: During validation, all MC methods agreed with experiment within the stated uncertainties: MC determined field output factors agreed within 0.6% of the TPS and 1.4% of film; and MC simulated measurement ratios matched physically measured ratios within 1%. The final k correction factors for the PTW microDiamond in the solid water phantom approached unity to within 0.4%±1.7% for all the helmet sizes except the 4 mm; the 4 mm helmet size over-responded by 3.2%±1.7%, resulting in a k factor of 0.969. Conclusion: Similar to what has been found in the Gamma Knife Perfexion, the PTW microDiamond requires little to no corrections except for the smallest 4 mm field. The over-response can be corrected via the Alfonso formalism using the correction factors determined in this work. Using the MC calculated correction factors, the PTW microDiamond detector is an effective dosimeter in all available helmet sizes. The authors would like to thank PTW (Friedberg, Germany) for providing the PTW microDiamond detector for this research.

07 ISOTOPE AND RADIATION SOURCES↗

TH-AB-207A-07: Radiation Dose Simulation for a Newly Proposed Dynamic Bowtie Filters for CT Using Fast Monte Carlo Methods

Purpose: Dynamic bowtie filter is an innovative design capable of modulating the X-ray and balancing the flux in the detectors, and it introduces a new way of patient-specific CT scan optimizations. This study demonstrates the feasibility of performing fast Monte Carlo dose calculation for a type of dynamic bowtie filter for cone-beam CT (Liu et al. 2014 9(7) PloS one) using MIC coprocessors. Methods: The dynamic bowtie filter in question consists of a highly attenuating bowtie component (HB) and a weakly attenuating bowtie (WB). The HB is filled with CeCl3 solution and its surface is defined by a transcendental equation. The WB is an elliptical cylinder filled with air and immersed in the HB. As the scanner rotates, the orientation of WB remains the same with the static patient. In our Monte Carlo simulation, the HB was approximated by 576 boxes. The phantom was a voxelized elliptical cylinder composed of PMMA and surrounded by air (44cm×44cm×40cm, 1000×1000×1 voxels). The dose to the PMMA phantom was tallied with 0.15% statistical uncertainty under 100 kVp source. Two Monte Carlo codes ARCHER and MCNP-6.1 were compared. Both used double-precision. Compiler flags that may trade accuracy for speed were avoided. Results: The wall time of the simulation was 25.4 seconds by ARCHER on a 5110P MIC, 40 seconds on a X5650 CPU, and 523 seconds by the multithreaded MCNP on the same CPU. The high performance of ARCHER is attributed to the parameterized geometry and vectorization of the program hotspots. Conclusion: The dynamic bowtie filter modeled in this study is able to effectively reduce the dynamic range of the detected signals for the photon-counting detectors. With appropriate software optimization methods, the accelerator-based (MIC and GPU) Monte Carlo dose engines have shown good performance and can contribute to patient-specific CT scan optimizations.

60 APPLIED LIFE SCIENCES↗

SU-F-T-376: The Efficiency of Calculating Photonuclear Reaction On High-Energy Photon Therapy by Monte Carlo Method

Purpose: Secondary-neutrons having harmful influences to a human body are generated by photonuclear reaction on high-energy photon therapy. Their characteristics are not known in detail since the calculation to evaluate them takes very long time. PHITS(Particle and Heavy Ion Transport code System) Monte Carlo code since versions 2.80 has the new parameter “pnimul” raising the probability of occurring photonuclear reaction forcibly to make the efficiency of calculation. We investigated the optimum value of “pnimul” on high-energy photon therapy. Methods: The geometry of accelerator head based on the specification of a Varian Clinac 21EX was used for PHITS ver. 2.80. The phantom (30 cm * 30 cm * 30 cm) filled the composition defined by ICRU(International Commission on Radiation Units) was placed at source-surface distance 100 cm. We calculated the neutron energy spectra in the surface of ICRU phantom with “pnimal” setting 1, 10, 100, 1000, 10000 and compared the total calculation time and the behavior of photon using PDD(Percentage Depth Dose) and OCR(Off-Center Ratio). Next, the cutoff energy of photon, electron and positron were investigated for the calculation efficiency with 4, 5, 6 and 7 MeV. Results: The calculation total time until the errors of neutron fluence become within 1% decreased as increasing “pnimul”. PDD and OCR showed no differences by the parameter. The calculation time setting the cutoff energy like 4, 5, 6 and 7 MeV decreased as increasing the cutoff energy. However, the errors of photon become within 1% did not decrease by the cutoff energy. Conclusion: The optimum values of “pnimul” and the cutoff energy were investigated on high-energy photon therapy. It is suggest that using the optimum “pnimul” makes the calculation efficiency. The study of the cutoff energy need more investigation.

60 APPLIED LIFE SCIENCES↗

A backward Monte-Carlo method for time-dependent runaway electron simulations

Kinetic descriptions of runaway electrons (REs) are usually based on Fokker-Planck models that determine the probability distribution function of REs in 2-dimensional momentum space. Despite the simplification involved, the Fokker-Planck equation can rarely be solved analytically and direct numerical approaches [e.g., continuum and particle-based Monte Carlo (MC)] can be time consuming, especially in the computation of asymptotic-type observables including the runaway probability, the slowing-down and runaway mean times, and the energy limit probability. In this study, we present a novel backward MC approach to these problems based on backward stochastic differential equations that describe the dynamics of the runaway probability by means of the Feynman-Kac theory. The key ingredient of the backward MC algorithm is to place all the particles in a runaway state and simulate them backward from the terminal time to the initial time. As such, our approach can provide much faster convergence than direct MC methods (by significantly reducing the number of particles required to achieve a prescribed accuracy) while at the same time maintaining the advantages of particle-based methods (compared to continuum approaches). The proposed algorithm is unconditionally stable and can be parallelized as easy as the direct MC method, and its extension to dimensions higher than two is straightforward, thus paving the way for conducting large-scale RE simulation.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Neutral band gap of carbon by quantum Monte Carlo methods

We present a method of calculating the energy gap of a charge-neutral excitation using only ground-state calculations. We report Quantum Monte Carlo calculations of Γ→ Γ and Γ → X particle-hole excitation energies in diamond carbon. We analyze the finite-size effect and find the same 1/L decay rate as that in a charged excitation, where L is the linear extension of the supercell. This slow decay is attributed to the delocalized nature of the excitation in supercells too small to accommodate excitonic binding effects. At larger system sizes, the apparent 1/L decay crosses over to a 1/L 3 behavior. Estimation of the scale of exciton binding can be used to correct finite-size effects of neutral gaps.

36 MATERIALS SCIENCE↗

Application of Markov Chain Monte Carlo Methods for Uncertainty Quantification in Inverse Transport Problems

Determination of the components of a radioactive source/shield system using the system’s radiation signature is of great importance in homeland security, material safeguards, and waste management. Although significant progress has been made toward solving this inverse transport problem in recent years, work remains to be done to quantify the uncertainty in reconstructed results. In this article we apply two Markov chain Monte Carlo (MCMC) approaches, the delayed rejection adaptive metropolis (DRAM) and differential evolution adaptive metropolis (DREAM) methods, to solve inverse problems and quantify uncertainty. The DRAM method uses delayed rejection combined with global adaptation of the proposal covariance matrix. Furthermore, the DREAM method hybridizes MCMC sampling with the differential evolution (DE) algorithm. In numerical test cases, the DRAM and DREAM methods are shown to be superior to a first-order inverse Hessian approach for problems with noisy data and multiple unknown quantities, with DREAM converging to the posterior distribution more quickly than DRAM. The DREAM and DRAM results indicate that a full posterior distribution is required to quantify uncertainty in many inverse transport problems.

98 NUCLEAR DISARMAMENT, SAFEGUARDS, AND PHYSICAL P↗

Numerical analysis of gas exhaust in Wendelstein 7-X using the direct simulation Monte Carlo method

The present work is focused on a 3D numerical assessment of the Wendelstein 7-X (W7-X) particle exhaust. For all the numerical simulations the direct simulation Monte Carlo solver of the DIVGAS workflow, has been employed. The complex 3D geometry of the sub-divertor region includes the pumping gap panel, supporting structures, cooling pipes as well as the cryo-vacuum pump. All the considered flow simulations correspond to the Standard magnetic configuration of W7-X. The main conclusions, which can be extracted from the present numerical analysis could be summarized as follows; The coupling between EMC3-EIRENE and DIVGAS, which considers the fact that the incoming neutral particle flux at the sub-divertor is based on realistic plasma background, has been demonstrated. Three plasma scenarios have been considered, for which is clearly seen that by increasing the heating power, the neutral pressure as well as the resulting pumping efficiency is increased. The obtained numerical results of the neutral pressure in the sub-divertor lie within a more general scan matrix, which assumes a wider range of incoming particle flux, namely 10 19 –10 24 (s −1 ). It has been observed that, the sub-divertor neutral pressure is proportional to the incoming neutral particle flux, with the effective pumping speed to be a constant of proportionality. The influence of switching off the cryo-vacuum pump on the sub-divertor pressure is rather modest and a weak increase of the neutral pressure in the sub-divertor is expected. Correlations of the sub-divertor pressure with the total incoming particle flux as well as the individual pumped flux at each of the AEH and AEP sections have been deduced. Moreover, it has been demonstrated that the influence of the incoming neutral particle flux on the albedo coefficient at the AEH and AEP pumping gaps is rather weak. All the above numerical findings will actively support the optimization of the W7-X particle exhaust, in view of future experimental campaigns.

DSMC method↗

Application of Distribution Transformer Thermal Life Models to Electrified Vehicle Charging Loads Using Monte-Carlo Method: Preprint

Concentrated purchasing patterns of plug-in vehicles may result in localized distribution transformer overload scenarios. Prolonged periods of transformer overloading causes service life decrements, and in worst-case scenarios, results in tripped thermal relays and residential service outages. This analysis will review distribution transformer load models developed in the IEC 60076 standard, andapply the model to a neighborhood with plug-in hybrids. Residential distribution transformers are sized such that night-time cooling provides thermal recovery from heavy load conditions during the daytime utility peak. It is expected that PHEVs will primarily be charged at night in a residential setting. If not managed properly, some distribution transformers could become overloaded, leading toa reduction in transformer life expectancy, thus increasing costs to utilities and consumers. A Monte-Carlo scheme simulated each day of the year, evaluating 100 load scenarios as it swept through the following variables: number of vehicle per transformer, transformer size, and charging rate. A general method for determining expected transformer aging rate will be developed, based on the energyneeds of plug-in vehicles loading a residential transformer.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Applications of the method of Monte Carlo to problems in thermal radiation

A summary of the work involving the Monte Carlo method in the solution of problems in thermal radiation transfer is presented, which indicates general methods previously used for solving problems in which radiation is coupled with other modes of energy transfer. Previous work involving radiation in absorbing-emitting media is included. An example is outlined to indicate the use of the Monte Carlo method in the design of a space radiator. Suggestions are given for solution of a complex case incorporating the effects of coupled conduction, convection and radiation, wavelength dependent and selective surfaces, nonisothermal conditions, and strongly directional or nondiffuse emitting and reflecting surfaces. A discussion is given of the factors that may affect convergence, running time, and accuracy of the Monte Carlo solutions and of the advantages and disadvantages of this approach for practical problems. Also discussed are the case of programming for complex problems and the probable machine time requirements of the method.

THERMAL RADIATION↗

Simulation of Watts Bar Unit 1 Initial Startup Tests with Continuous Energy Monte Carlo Methods

The Consortium for Advanced Simulation of Light Water Reactors* is developing a collection of methods and software products known as VERA, the Virtual Environment for Reactor Applications. One component of the testing and validation plan for VERA is comparison of neutronics results to a set of continuous energy Monte Carlo solutions for a range of pressurized water reactor geometries using the SCALE component KENO-VI developed by Oak Ridge National Laboratory. Recent improvements in data, methods, and parallelism have enabled KENO, previously utilized predominately as a criticality safety code, to demonstrate excellent capability and performance for reactor physics applications. The highly detailed and rigorous KENO solutions provide a reliable nu-meric reference for VERAneutronics and also demonstrate the most accurate predictions achievable by modeling and simulations tools for comparison to operating plant data. This paper demonstrates the performance of KENO-VI for the Watts Bar Unit 1 Cycle 1 zero power physics tests, including reactor criticality, control rod worths, and isothermal temperature coefficients.

CASL↗

Efficient evaluation of small failure probability in high-dimensional groundwater contaminant transport modeling via a two-stage Monte Carlo method

In decision-making for groundwater management and contamination remediation, it is important to accurately evaluate the probability of the occurrence of a failure event. For small failure probability analysis, a large number of model evaluations are needed in the Monte Carlo (MC) simulation, which is impractical for CPU-demanding models. One approach to alleviate the computational cost caused by the model evaluations is to construct a computationally inexpensive surrogate model instead. However, using a surrogate approximation can cause an extra error in the failure probability analysis. Furthermore, constructing accurate surrogates is challenging for high-dimensional models, i.e., models containing many uncertain input parameters. To address these issues, we propose an efficient two-stage MC approach for small failure probability analysis in high-dimensional groundwater contaminant transport modeling. In the first stage, a low-dimensional representation of the original high-dimensional model is sought with Karhunen–Loève expansion and sliced inverse regression jointly, which allows for the easy construction of a surrogate with polynomial chaos expansion. Then a surrogate-based MC simulation is implemented. In the second stage, the small number of samples that are close to the failure boundary are re-evaluated with the original model, which corrects the bias introduced by the surrogate approximation. The proposed approach is tested with a numerical case study and is shown to be 100 times faster than the traditional MC approach in achieving the same level of estimation accuracy.

54 ENVIRONMENTAL SCIENCES↗

Scalable multilevel Monte Carlo methods exploiting parallel redistribution on coarse levels

Here, we study an element agglomeration coarsening strategy that requires data redistribution at coarse levels when the number of coarse elements becomes smaller than the number of MPI processes used on the finest level. The overall procedure generates coarse elements (general unstructured unions of fine grid elements) within the framework of element-based algebraic multigrid methods (or AMGe) studied previously. The AMGe-generated coarse spaces have the ability to exhibit approximation properties of the same order as the fine-level spaces since by construction they contain the piecewise polynomials of the same order as on the fine level. These approximation properties are key for the successful use of AMGe in multilevel solvers for nonlinear partial differential equations as well as for multilevel Monte Carlo (MLMC) simulations. The ability to coarsen without being constrained by the number of MPI processes, as described in the present paper, allows to improve the scalability of these solvers as well as the overall MLMC method. The paper illustrates this latter fact with detailed scalability study of MLMC simulations applied to model Darcy equations with a stochastic log-normal permeability field.

AMGe↗

Adjoint-based deviational Monte Carlo methods for phonon transport calculations

In the field of linear transport, adjoint formulations exploit linearity to derive powerful reciprocity relations between a variety of quantities of interest. We develop an adjoint formulation of the linearized Boltzmann transport equation for phonon transport. We use this formulation for accelerating deviational Monte Carlo simulations of complex, multiscale problems. Benefits include significant computational savings via direct variance reduction, or by enabling formulations which allow more efficient use of computational resources, such as formulations which provide high resolution in a particular phase-space dimension (e.g., spectral). We show that the proposed adjoint-based methods are particularly well suited to problems involving a wide range of length scales (e.g., nanometers to hundreds of microns) and lead to computational methods that can calculate quantities of interest with a cost that is independent of the system characteristic length scale, thus removing the traditional stiffness of kinetic descriptions. Applications to problems of current interest, such as simulation of transient thermoreflectance experiments or spectrally resolved calculation of the effective thermal conductivity of nanostructured materials, are presented and discussed in detail.

42 ENGINEERING↗

Recent Progress in the Electroweak Structure of Light Nuclei Using Quantum Monte Carlo Methods

Nuclei will play a prominent role in searches for physics beyond the Standard Model as the active material in experiments. In order to reliably interpret new physics signals, one needs an accurate model of the underlying nuclear dynamics. In this review, we discuss recent progress made with quantum Monte Carlo approaches for calculating the electroweak structure of light nuclei. We place particular emphasis on recent β decay, muon capture, neutrinoless double β decay, and electron scattering results.

Physics↗

Determination of nuclear PDFs using Markov chain Monte Carlo methods

Global QCD analyses of nuclear parton distribution functions (nPDFs) have traditionally relied on the Hessian method for uncertainty estimation. However, the inherent Gaussian approximation and reliance on local curvature often prove insufficient for nPDF fits, which are frequently characterized by limited data constraints and non-Gaussian likelihoods. In this paper, we present the first nPDF determination based on Markov Chain Monte Carlo (MCMC) techniques, implemented within the nCTEQ framework using an adaptive Metropolis-Hastings algorithm. The MCMC approach enables a direct mapping of the posterior distribution and reveals a highly nontrivial parameter-space structure, including multiple modes and pronounced non-Gaussian behavior, particularly for the valence PDFs. We perform the first single-nucleus global analysis of lead PDFs using exclusively lead data and compare it to a multi-nuclei fit employing a standard analytic A dependence. The inclusion of lighter nuclei reduces quark uncertainties and modifies the shape of the lead PDFs, while leaving the gluon distribution largely unaffected. A complementary Hessian analysis exposes systematic limitations of the Gaussian approximation. Our results demonstrate that MCMC methods provide a more reliable framework for uncertainty quantification in nPDF determinations.

Derakhshanian, N. [Institute of Nuclear Physics Po↗