Real-Time 3D Visualization of Radiation Measurements from a Multi-Modal Directional System in GPS Denied Environments
Explore the source record for details and available documents.
SEARCH · Engineering Papers
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Explore the source record for details and available documents.
Purpose: To investigate variation in measurements of breast skin thickness obtained using different imaging modalities, including mammography, computed tomography (CT), ultrasound, and magnetic resonance imaging (MRI). Methods: Breast skin thicknesses as measured by mammography, CT, ultrasound, and MRI were compared. Mammographic measurements of skin thickness were obtained from published studies that utilized standard positioning (upright) and compression. CT measurements of skin thickness were obtained from a published study of a prototype breast CT scanner in which the women were in the prone position and the breast was uncompressed. Dermatological ultrasound exams of the breast skin were conducted at our institution, with the subjects in the upright position and the breast uncompressed. Breast skin thickness was calculated from breast MRI exams at our institution, with the patient in the prone position and the breast uncompressed. Results: T tests for independent samples demonstrated significant differences in the mean breast skin thickness as measured by different imaging modalities. Repeated measures ANOVA revealed significant differences in breast skin thickness across different quadrants of the breast for some modalities. Conclusion: The measurement of breast skin thickness is significantly different across different imaging modalities. Differences in the amount of compression and differences in patient positioning are possible reasons why measurements of breast skin thickness vary by modality.
Purpose: The role of physicist in the academic and private hospital environment continues to evolve and expand. This becomes more obvious with the newly revised requirements of the Joint Commission (JC) on imaging modalities and the continued updated requirements of ACR accreditation for medical physics (i.e., starting in June 2014, a physicists test will be needed before US accreditation). We provide an informative review on the role of diagnostic medical physicist and hope that our experience will expedite junior physicists in understanding their role in medical centers, and be ready to more opportunities. Methods: Based on our experience, diagnostic medical physicists in both academic and private medical centers perform several clinical functions. These include providing clinical service and physics support, ensuring that all ionizing radiation devices are tested and operated in compliance with the State and Federal laws, regulations and guidelines. We also discuss the training and education required to ensure that the radiation exposure to patients and staff is as low as reasonably achievable. We review the overlapping roles of medical and health physicist in some institutions. Results: A detailed scheme on the new requirements (effective 7/1/2014) of the JC is provided. In 2015, new standards for fluoroscopy, cone beam CT and the qualifications of staff will be phased in. A summary of new ACR requirements for different modalities is presented. Medical physicist have other duties such as sitting on CT and fluoroscopy committees for protocols design, training of non-radiologists to meet the new fluoroscopy rules, as well as helping with special therapies such as Yittrium 90 cases. Conclusion: Medical physicists in both academic and private hospitals are positioned to be more involved and prominent. Diagnostic physicists need to be more proactive to involve themselves in the day to day activities of the radiology department.
Purpose: Oscillatory dynamics in acute hypoxia have been observed, but poorly understood. They have mostly been attributed to vascular perturbations, but no link has yet been made to metabolic causes. We set out to determine the fundamental frequencies and test for coherence in tumor oxygen dynamics and spatial properties. Methods: Severe combined immunodeficient (SCID) mice were inoculated onto bilateral flanks with human derived head and neck carcinoma (UW-SCC22) cell line xenografts. Oxygen dynamics were monitored in the tumor every minute for an hour using three modalities: blood oxygen level dependent - magnetic resonance imaging (BOLD-MRI), hemoglobin oxygen saturation photoacoustic, and locally manufactured optical probes for spectral fitting. A statistical test was used to separate fluctuating from non-fluctuating voxels and pixels in BOLD-MRI and photoacoustic data respectively. The power spectrum density (PSD) and the autocorrelation functions were calculated for the time series of each voxel, pixel and region, of the BOLD-MRI, photoacoustic or fiber optic data respectively. Results: Using all three techniques, intermittent oxygen dynamics with both coherent and incoherent signatures was observed in the tumors. Upon averaging the PSDs of fluctuating voxels and pixels, it was found that these oscillations occurred with periods of minutes to tens of minutes from all three approaches. Observations from the BOLD-MRI and photoacoustic data showed that clusters of voxels oscillated in a synchronized manner. Conclusion: We were able to use three different modalities to show that fluctuation in tumor oxygen is both coherent and incoherent, with periods of minutes to tens of minutes. These periods are very similar to those from the well-established metabolic, non-linear biomechanical phenomenon called the glycolytic oscillator. This may provide an additional explanation to the cause of cyclic hypoxia. Such dynamics could have profound implications in hypofractionated radiotherapy regiments and could help guide treatment and make it more patient specific. The authors would like to thank the University of Wisconsin Carbone Cancer Center (UWCCC) for the funds to complete this project. This work is also supported in part by NIH/NCI P30 CA014520- UW Comprehensive Cancer Center Support”.
Recent advances in characterization techniques that generate large datasets of material microstructure images require robust, automated image-processing. We applied an unsupervised anomaly detection method called feature anomaly detection system (FADS) to automatically detect and quantify microstructure changes in images of the explosive pentaerythritol tetranitrate (PETN) aged at various temperatures. We demonstrated the FADS approach on two-dimensional images extracted from computed tomography scans, but the same technique can be readily applied to other imaging modalities. FADS calculates anomaly scores on the basis of differences in filter activations of nominal and test data in pretrained convolutional neural networks. The FADS scores successfully differentiated between pristine PETN and PETN aged at a temperature where material coarsening occurred. Morphological metric analysis of segmented images verified observed trends in FADS scores as a function of aging temperature and aging time, specifically by calculating volume fractions, specific boundary lengths, two-point correlation functions, and local thicknesses. Here, the FADS technique has two important advantages compared to traditional morphological analysis: First, it uses grayscale images as input, rather than images that are segmented to separate the appropriate phases; and second, FADS scores capture any type of changes among image sets, rather than requiring prior knowledge or selection of a relevant set of metrics.
The electrochemical performance and cycle life of lithium-ion batteries (LIBs) depend on the electrochemical, chemical, and mechanical behavior of electrodes and electrolytes. Despite extensive studies conducted previously, challenges exist to decouple these behaviors, capture the evolution of electro-chemo-mechanical behavior in realistic conditions, and correlate atomic-scale stress evolution to micro-scale bulk mechanical degradation. Here, we report multiscale operando techniques to investigate polydisperse battery electrodes by integrating volume-averaged quantitative synchrotron X-ray scattering with high-resolution transmission X-ray microscopy (TXM). The former provides us information spanning a wide spatial range, from Angstrom-level atomic structures to micrometer-level particle scales, while the latter provides time-resolved 2D images of the particles during cycling. The complementarity of the two operando techniques is demonstrated by an over-lithiation test of LiCoO 2 electrodes, where particles crack and eventually pulverize. Additionally, the techniques are applied to study LiCoO 2 cycling stability from 3.0 V to 4.5 V. Operando X-ray scattering result shows nanometer-scale features keep forming in LiCoO 2 electrodes during cycling, resulting in an increased projected area observed by the TXM experiment. The formation of such features is inhibited by a polymer coating on the electrode, leading to vastly improved cycling stability. The polymer coating alleviates LiCoO 2 surface deterioration, reduces side product generation, and inhibits LiCoO 2 particles volume expansion during the cycling test. These operando multimodal X-ray techniques presented herein thus offer a novel, multiscale diagnostic modality for studying existing and emerging battery materials, aiding the development of next-generation LIBs.
Recent proliferation of distributed energy sources in distribution or sub-transmission systems necessitates close monitoring of these three-phase power grids which typically operate under unbalanced loading conditions. Unlike the transmission systems where the network equations are commonly based on the positive sequence component models, a detailed three phase model will have to be used in implementing network applications for these systems. In the specific case of the state estimator, where measurement and parameter errors may bias the solution, bad data and parameter error detection algorithms should also be incorporated. Implementing the state estimator and error detection algorithms for three-phase systems impose additional computational burden and modifications to the state estimation code. This paper proposes a practical solution to avoid these issues by using synchronized phasor measurements and modal decoupling. The previously developed parameter error detection algorithm based on the normalized Lagrange multipliers (NLM) test is applied to the measurements independently in each mode in parallel, not only saving CPU time but also avoiding new code development for a three-phase estimator. Different parameter error scenarios are created and tested to verify the effectiveness of the proposed error detection approach.
Motivation: Integrating multimodal data represents an effective approach to predicting biomedical characteristics, such as protein functions and disease outcomes. However, existing data integration approaches do not sufficiently address the heterogeneous semantics of multimodal data. In particular, early and intermediate approaches that rely on a uniform integrated representation reinforce the consensus among the modalities but may lose exclusive local information. The alternative late integration approach that can address this challenge has not been systematically studied for biomedical problems. Results: We propose Ensemble Integration (EI) as a novel systematic implementation of the late integration approach. EI infers local predictive models from the individual data modalities using appropriate algorithms and uses heterogeneous ensemble algorithms to integrate these local models into a global predictive model. We also propose a novel interpretation method for EI models. We tested EI on the problems of predicting protein function from multimodal STRING data and mortality due to coronavirus disease 2019 (COVID-19) from multimodal data in electronic health records. We found that EI accomplished its goal of producing significantly more accurate predictions than each individual modality. It also performed better than several established early integration methods for each of these problems. The interpretation of a representative EI model for COVID-19 mortality prediction identified several disease-relevant features, such as laboratory test (blood urea nitrogen and calcium) and vital sign measurements (minimum oxygen saturation) and demographics (age). These results demonstrated the effectiveness of the EI framework for biomedical data integration and predictive modeling.
Estimation of two-phase fluid flow properties is important to understand and predict water and gas movement through the vadose zone for agricultural, hydrogeological, and engineering applications, such as for vapor-phase contaminant transport and/or containment of noble gases in the subsurface. In this second progress report of FY22, we present two ongoing activities related to imbibition testing on volcanic rock samples. We present the development of a new analytical solution predicting the temperature response observed during imbibition into dry samples, as discussed in our previous first progress report for FY22. We also illustrate the use of a multi-modal capillary pressure distribution to simulate both early- and late-time imbibition data collected on tuff core that can exhibit multiple pore types. These FY22 imbibition tests were conducted for an extended period (i.e., far beyond the time required for the wetting front to reach the top of the sample), which is necessary for parameter estimation and characterization of two different pore types within the samples.
The heterogeneity of polymer electrolyte fuel cell catalyst degradation is studied under varied relative humidity and types of feed gas. Accelerated stress tests (ASTs) are performed on four membrane electrode assemblies (MEAs) under wet and dry conditions in an air or nitrogen environment for 30 000 square voltage cycles. The largest electrochemically active area loss is observed for MEA under wet conditions in a nitrogen gas environment AST due to constant upper potential limit of 0.95 V and significant water content. The mean Pt particle size is larger for the ASTs under wet conditions compared to dry conditions, and the Pt particle size under land is generally larger than under the channel. Observations from ASTs in both conditions and gas environments indicate that water content promotes Pt particle size growth. ASTs under wet conditions and an air environment show the largest difference in Pt particle size growth for inlet versus outlet and channel versus land, which can be attributed to larger water content at outlet and under land compared to inlet and under channel. From X-ray fluorescence experiments Pt particle size increase is a local phenomenon as Pt loading remains relatively uniform across the MEA.
Purpose: To investigate patient average glandular dose (AGD) characteristics of diagnostic mammography. Methods: The techniques used to image 14420 patients who received diagnostic work up mammography from October 2008 to December 2014 at one academic hospital were retrospectively collected. The most common diagnostic views and the techniques used for each according to compressed breast thickness were determined. For all techniques, 1st half value layer and air kerma output per tube current-exposure time product were measured; then the incident air kerma for each acquisition was calculated. The values for normalized glandular dose (DgN) were obtained with a validated Monte Carlo simulation of mammographic acquisition. The mono-energetic DgN results were combined according to relative fluence using the TASMICS model to obtain DgN coefficients for each spectrum. The spectral DgN and calculated incident air kerma were used to estimate AGD of patients with breast thickness ranging from 2 to 8 cm. Results: The most common views utilized during diagnostic mammography were magnification craniocaudal (24%), magnification mediolateral (19%), spot craniocaudal (28%), and spot mediolateral oblique (24%). The AGD increased with increasing breast thickness for both the magnification and spot views. The AGD for a 5.5 cm thick breast was approximately 6.8 mGy and 2.2 mGy for the magnification and spot views, respectively. The AGD ranged from 3.6 mGy to 6.8 mGy for the magnification views and from 1.0 mGy to 3.1 mGy for spot views. The difference in AGD between the two magnification views or the two spot views was not significant. Conclusion: These results provide information on breast dose to which screening recalled women are exposed to. In addition to understanding the dose used for common clinical imaging tests, this data could be used when comparing use of mammography for diagnostic workup to other potential modalities, such as breast tomosynthesis and breast CT.
Linear eigenmode analysis often fails to describe turbulence in model systems that have non-normal linear operators and thus nonorthogonal eigenmodes, which can cause fluctuations to transiently grow faster than expected from eigenmode analysis. When combined with energetically conservative nonlinear mode mixing, transient growth can lead to sustained turbulence even in the absence of eigenmode instability. Since linear operators ultimately provide the turbulent fluctuations with energy, it is useful to define a growth rate that takes into account non-modal effects, allowing for prediction of energy injection, transport levels, and possibly even turbulent onset in the subcritical regime. We define such a non-modal growth rate using a relatively simple model of the statistical effect that the nonlinearities have on cross-phases and amplitude ratios of the system state variables. In particular, we model the nonlinearities as delta-function-like, periodic forces that randomize the state variables once every eddy turnover time. Furthermore, we estimate the eddy turnover time to be the inverse of the least stable eigenmode frequency or growth rate, which allows for prediction without nonlinear numerical simulation. We test this procedure on the 2D and 3D Hasegawa-Wakatani model [A. Hasegawa and M. Wakatani, Phys. Rev. Lett. 50, 682 (1983)] and find that the non-modal growth rate is a good predictor of energy injection rates, especially in the strongly non-normal, fully developed turbulence regime.
Carnegie Mellon University (CMU) under contract from Department of Energy/National Energy Technology Laboratory (DoE/NETL) and co-funding from the Northeast Gas Association (NGA), has completed the overall system design, field-trial and Magnetic Flux Leakage (MFL) sensor evaluation program for the next-generation Explorer-II (X-II) live gas main Non-destructive Evaluation (NDE) and visual inspection robot platform. The design is based on the Explorer-I prototype which was built and field-tested under a prior (also DoE- and NGA co-funded) program, and served as the validation that self-powered robots under wireless control could access and navigate live natural gas distribution mains. The X-II system design ({approx}8 ft. and 66 lbs.) was heavily based on the X-I design, yet was substantially expanded to allow the addition of NDE sensor systems (while retaining its visual inspection capability), making it a modular system, and expanding its ability to operate at pressures up to 750 psig (high-pressure and unpiggable steel-pipe distribution mains). A new electronics architecture and on-board software kernel were added to again improve system performance. A locating sonde system was integrated to allow for absolute position-referencing during inspection (coupled with external differential GPS) and emergency-locating. The power system was upgraded to utilize lithium-based battery-cells for an increase in mission-time. The resulting robot-train system with CAD renderings of the individual modules. The system architecture now relies on a dual set of end camera-modules to house the 32-bit processors (Single-Board Computer or SBC) as well as the imaging and wireless (off-board) and CAN-based (on-board) communication hardware and software systems (as well as the sonde-coil and -electronics). The drive-module (2 ea.) are still responsible for bracing (and centering) to drive in push/pull fashion the robot train into and through the pipes and obstacles. The steering modules and their arrangement, still allow the robot to configure itself to perform any-angle (up to 90 deg) turns in any orientation (incl. vertical), and enable the live launching and recovery of the system using custom fittings and a (to be developed) launch-chamber/-tube. The battery modules are used to power the system, by providing power to the robot's bus. The support modules perform the functions of centration for the rest of the train as well as odometry pickups using incremental encoding schemes. The electronics architecture is based on a distributed (8-bit) microprocessor architecture (at least 1 in ea. module) communicating to a (one of two) 32-bit SBC, which manages all video-processing, posture and motion control as well as CAN and wireless communications. The operator controls the entire system from an off-board (laptop) controller, which is in constant wireless communication with the robot train in the pipe. The sensor modules collect data and forward it to the robot operator computer (via the CAN-wireless communications chain), who then transfers it to a dedicated NDE data-storage and post-processing computer for further (real-time or off-line) analysis. The prototype robot system was built and tested indoors and outdoors, outfitted with a Remote-Field Eddy Current (RFEC) sensor integrated as its main NDE sensor modality. An angled launcher, allowing for live launching and retrieval, was also built to suit custom angled launch-fittings from TDW. The prototype vehicle and launcher systems are shown. The complete system, including the in-pipe robot train, launcher, integrated NDE-sensor and real-time video and control console and NDE-data collection and -processing and real-time display, were demonstrated to all sponsors prior to proceeding into final field-trials--the individual components and setting for said acceptance demonstration are shown. The launcher-tube was also used to verify that the vehicle system is capable of operating in high-pressure environments, and is safely deployable using proper evacuating/purging techniques for operation in the potentially explosive natural gas environment. The test-setting and environment for safety-certification of the X-II robot platform and the launch and recovery procedures, is shown. Field-trials were successfully carried out in a live steel pipeline in Northwestern Pennsylvania. The robot was launched and recovered multiple times, travelling thousands of feet and communicating in real time with video and command-and-control (C&C) data under remote operator control from a laptop, with NDE sensor-data streaming to a second computer for storage, display and post-processing. Representative images of the activities and systems used in the week-long field-trial are shown. CMU also evaluated the ability of the X-II design to be able to integrate an MFL sensor, by adding additional drive-/battery-/steering- and support-modules to extend the X-II train.
Beam-excited higher order modes (HOM) in accelerating cavities contain transverse beam position information. Previous studies have narrowed down three modal options for beam position diagnostics in the third harmonic 3.9 GHz cavities at FLASH. Localized modes in the beam pipes at approximately 4.1 GHz and in the fifth cavity dipole band at approximately 9 GHz were found, that can provide a local measurement of the beam position. In contrast, propagating modes in the first and second dipole bands between 4.2 and 5.5 GHz can reach a better resolution. All the options were assessed with a specially designed test electronics built by Fermilab. The aim is to define a mode or spectral region suitable for the HOM electronics. Two data analysis techniques are used and compared in extracting beam position information from the dipole HOMs: direct linear regression and singular value decomposition. Current experiments suggest a resolution of 50 {\mu}m accuracy in predicting local beam position using modes in the fifth dipole band, and a global resolution of 20 {\mu}m over the complete module. Based on these results we decided to build a HOM electronics for the second dipole band and the fifth dipole band, so that we will have both high resolution measurements for the whole module, and localized measurements for individual cavity. The prototype electronics is being built by Fermilab and planned to be tested in FLASH by the end of 2012.
Herein, we utilize an on-line electrochemical flow cell coupled with an inductively coupled plasma-mass spectrometer (ICP-MS) to characterize the impact of composition and reactant gas on the multielement dissolution of Mn(-Cr)-Sb-O electrocatalysts. Compared to Mn 2 O 3 and Cr 2 O 3 oxides, we find that the antimonate framework stabilizes Mn at OER potentials and Cr at both ORR and OER potentials. Furthermore, dissolution of Mn and Cr from Mn(-Cr)-Sb-O is found to be driven by ORR reaction rate, with minimal dissolution under N 2 . We observe preferential dissolution of Cr totaling 13% over 10 minutes at 0.3, 0.6, and 0.9 V vs RHE, with only 1.5% loss of Mn, indicating an enrichment of Mn at the surface of the particles. Despite this asymmetric dissolution, in situ X-ray absorption spectroscopy (XAS) showed no measurable changes in the Mn K-edge at comparable potentials. This lack of change could suggest that modification to the Mn oxidation state in the surface layer is too small or that layer is too thin to be measured with the bulk XAS measurement. Lastly, on-line ICP-MS was used to assess the effects of applied potential, scan rate, and current of Mn-Cr-Sb-O during cyclic voltammetry and accelerated stress tests. With this deeper understanding of the interplay between oxygen reduction and dissolution, testing procedures were identified to maximize both activity and stability. This work highlights the use of multi-modal in situ characterization techniques in tandem to build a more complete model of stability and develop protocols for optimizing catalyst performance.
This paper enhances the Dissipating Energy Flow (DEF) method for forced oscillation source detection. The development focuses on improving the speed of the DEF method for oscillation source detection employed by ISO-NE. This is accomplished by using multi-signal modal estimation and statistical correlation to achieve robustness and detection accuracy. The effectiveness of the proposed method is tested on simulated and actual oscillation data showing that detection and localization can be achieved with shorter data windows. In addition, the utilization of the DEF as an energy filter to minimize false alarm rates is examined. Finally, real PMU data is used to evaluate the consistency of the DEF method and track the actual direction the Dissipating Energy (DE) flows in the power network.
Purpose: With the continuous development of new stent grafts and implantation techniques, it has now become technically feasible to treat abdominal aortic aneurysms (AAA) with challenging anatomy using endovascular repair with standard, fenestrated, or branched stent-grafts. In vitro experimentations are very useful to improve stent-graft design and conformability or imaging guidance for stent-graft delivery or follow-up. Vascular replicas also help to better understand the limitation of endovascular approaches in challenging anatomy and possibly improve surgical planning or training by practicing high risk clinical procedures in the laboratory to improve outcomes in the operating room. Most AAA phantoms available have a very basic anatomy, which is not representative of the clinical reality. This paper presents a method of fabrication of a realistic AAA phantom with a visible thrombus, as well as some mechanical properties characterizing such phantom. Methods: A realistic AAA geometry replica of a real patient anatomy taken from a multidetector computed tomography (CT) scan was manufactured. To demonstrate the multimodality imaging capability of this new phantom with a thrombus visible in magnetic resonance (MR) angiography, CT angiography (CTA), digital subtraction angiography (DSA), and ultrasound, image acquisitions with all these modalities were performed by using standard clinical protocols. Potential use of this phantom for stent deployment was also tested. A rheometer allowed defining hyperelastic and viscoelastic properties of phantom materials. Results: MR imaging measurements of SNR and CNR values on T1 and T2-weighted sequences and MR angiography indicated reasonable agreement with published values of AAA thrombus and abdominal components in vivo. X-ray absorption also lay within normal ranges of AAA patients and was representative of findings observed on CTA, fluoroscopy, and DSA. Ultrasound propagation speeds for developed materials were also in concordance with the literature for vascular and abdominal tissues. Conclusions: The mimicked abdominal tissues, AAA wall, and surrounding thrombus were developed to match imaging features of in vivo MR, CT, and ultrasound examinations. This phantom should be of value for image calibration, segmentation, and testing of endovascular devices for AAA endovascular repair.
The Open Radiation Monitoring (ORM) Project seeks to develop and demonstrate a modular radiation detection architecture designed specifically for use in arms control treaty verification (ACTV) applications that will facilitate rapid development of trusted systems to meet the needs of potential future treaties. Development of trusted systems to support potential future treaties is a complex and costly endeavor that typically results in a purpose-built system designed to perform one specific task. The majority of prior trusted system development efforts have relied on the use of commercial embedded computers or microprocessors to control the system and process the acquired data. These processors are complex, making authentication and certification of measurement systems and collected data challenging and time consuming. We believe that a modular architecture can be used to reduce more complex systems to a series of single-purpose building blocks that could be used to implement a variety of detection modalities with shared functionalities. With proper design, the functionality of individual modules can be confirmed through simple input/output testing, thereby facilitating equipment inspection and in turn building trust in the equipment by all treaty parties. Furthermore, a modular architecture can be used to control data flow within the measurement system, reducing the risk of "hidden switches" and constraining the amount of sensitive information that could potentially be inadvertently leaked. This report documents a conceptual modular system architecture that is designed to facilitate inspection in an effort to reduce overall authentication and certification burden. As of publication, this architecture remains in a conceptual phase and additional funding is required to prove out the utility of a modular architecture and test the assumptions used to rationalize the design.