Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microwave frequencies”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Electron density profile and associated fluctuation measurements using a microwave reflectometry diagnostic on Helically Symmetric eXperiment (HSX)

Abstract A dual-band frequency-modulated reflectometry is employed on the Helically Symmetric eXperiment (HSX) stellarator. This system equips a fast PIN switch to alternate the frequency source between two voltage-controlled oscillators, providing an operational frequency range from 14.5 GHz to 25.5 GHz. A monostatic antenna geometry and an ellipsoidal mirror are implemented in the vessel of HSX, where the polarization of the transmitted microwave can be switched between O- and X-mode to accommodate the magnetic field and plasma density. Although the original system was designed for density fluctuation measurement, significant efforts have been undertaken to improve the system performance and to realize the density profile inversion. Recent improvements of the system reported here include calibration of the dispersion in the transmission line, optimization of the waveform, and implementation of the Choi-Williams time–frequency distribution for spectral analysis. In this paper, we present the optimization of the reflectometry system along with first experimental measurements of the density profile and observations of fluctuations during gas puffing experiments.

Han, X. (ORCID:0000000184986433)↗

Phase-Slip Lines and Anomalous Josephson Effects in Tungsten Nanoscale Cluster-Based Topological Insulator Nanobridges: Implications for Topologically Protected Qubits and Quantum Sensors

Superconducting topological systems formed by a strong 3D topological insulator (TI) in proximity to a conventional s-wave superconductor (SC) have been intensely studied, as they may host Majorana zero modes. However, there are limited experimental realizations of TI-SC systems in which robust superconducting pairing is induced on the surface states of the TI and a topological superconducting state is established. Here, we fabricate a TI-SC system by depositing, via a focused ion beam, tungsten (W) nanoscale clusters on the surface of TI Bi 0.91 Sb 0.09 . We find that the resulting heterostructure supports phase-slip lines (PSLs) that act as effective Josephson junctions (JJs). Here, we probe the response of the system to microwave radiation. We find that for some ac frequencies, and powers, the resulting Shapiro steps’ structure of the voltage–current characteristic exhibits a missing first step and an unexpectedly wide second Shapiro step. The theoretical analysis of the measurements shows that the unusual Shapiro response arises from the interplay between a static JJ and a dynamic one and allows us to identify the conditions under which the missing first step can be attributed to the topological nature of the JJs formed by the PSLs. Our results suggest an approach to induce superconductivity in a TI, a route to realizing highly transparent topological JJs, and show how the response of superconducting systems to microwave radiation can be used to infer the dynamics of PSLs. Highly transparent topological junctions are promising candidates to realize vector field sensors with very high sensitivity. In addition, due to the nontrivial Berry phase of the TI’s surface states such junctions can be in a topological state which is ideal to create topologically protected qubits.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Dielectric and magnetic properties of microwave-absorbing FeAl x O y catalysts fabricated via solution combustion synthesis

Iron-based alumina (FeAl x O y ) nanocomposites are microwave-absorbers and catalysts, which makes them promising for emerging microwave-assisted thermocatalytic technologies. Solution combustion synthesis (SCS) has been used to synthesize FeAl x O y powders, and prior work has demonstrated that adjusting SCS parameters significantly changes phase composition and specific surface area of the products. However, it is unclear how synthesis parameters affect their microwave-absorbing properties, which are essential for optimizing microwave-assisted technologies. To address this challenge, in the present work, twelve different FeAl x O y products were synthesized at different combinations of the SCS parameters such as two fuels (citric acid and glycine), two heating modes (hotplate and muffle furnace), and three Fe:Al molar ratios (2:1, 1:1, 1:2). Dielectric and magnetic properties of the products were characterized using a network analyzer and a vibrating sample magnetometer. Based on the measured permittivity and permeability, penetration depth and reflection loss were calculated as a function of frequency and bed thickness. The products were heated by microwaves at 2.45 GHz and then examined with X-ray diffraction (XRD) analysis. For all products, the magnetic saturation was lower than for bulk iron oxides because of the small crystallite size and aluminum substitution. The use of glycine induced high dielectric losses and enabled fast microwave-heating rates compared to citric acid. Higher Fe:Al ratio also led to higher dielectric and magnetic losses. With glycine fuel, SCS in a furnace induced larger penetration depth and lower microwave absorption than SCS on a hotplate. The minimization of reflected power was more sensitive to the thickness of the product bed than to the frequency of the electromagnetic field. Post-heating XRD analysis revealed different phase transformations in the FeAl x O y powders depending on the SCS parameters. As a result, an FeAl x O y material, synthesized via incipient wetness impregnation, lacked magnetic losses and did not heat well as compared to the SCS products.

Combustion synthesis↗

Precision gyroscope from the helicity of light

We describe a gyroscope that measures rotation based on the effects of the rotation on the polarization of light. Rotation induces a differential phase shift in the propagation of left- and right-circularly polarized light and this phase shift can be measured in suitably designed interferometric setups. The signal in this setup is independent of the frequency of light, unlike various sources of noise such as vibrations, which cause phase shifts that depend on the frequency. Such vibrations are the practical limit on the sensitivity of conventional Sagnac-style optical interferometers that are typically used as gyroscopes. In the proposed setup, one can potentially mitigate this source of noise by simultaneously using two (or more) sources of light that have different frequencies. The signal in this setup scales with the total storage time of the light. Due to its frequency independence, it is thus most optimal to measure the signal using superconducting radio-frequency systems where the high finesse of the available cavities enables considerably longer storage times than is possible in an optical setup.

47 OTHER INSTRUMENTATION↗

Microwave measurements of the high magnetic field vortex motion pinning parameters in Nb$_3$Sn

The high frequency vortex motion in Nb3Sn was analyzed in this work up to 12 T. We used a dielectric loaded resonator tuned at 15 GHz to evaluate the surface impedance Z of a Nb3Sn bulk sample (24.8 at.%Sn). From the field induced variation of Z, the high frequency vortex parameters (the pinning constant k p , the depinning frequency ν p and the flux flow resistivity ρ ff ) were obtained over a large temperature and field range; their field and temperature dependencies were analyzed. Comparison with other superconducting materials shows that high frequency applications in strong magnetic fields are also feasible with Nb3Sn. In the present work, we report the first measurements about the microwave response in Nb3Sn in strong magnetic fields.

Alimenti, Andrea↗

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong 𝐶⁢𝑃 problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10 and 1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Inference of the optical depth to reionization τ from Planck CMB maps with convolutional neural networks

The optical depth to reionization, τ, is the least constrained parameter of the cosmological Λ cold dark matter (ΛCDM) model. To date, its most precise value is inferred from large-scale polarized cosmic microwave background (CMB) power spectra from the High Frequency Instrument (HFI) aboard the Planck satellite. These maps are known to contain significant contamination by residual non-Gaussian systematic effects, which are hard to model analytically. Therefore, robust constraints on τ are currently obtained through an empirical cross-spectrum likelihood built from simulations. In this paper, we present a likelihood-free inference of τ from polarized Planck HFI maps which, for the first time, is fully based on neural networks (NNs). NNs have the advantage of not requiring an analytical description of the data and can be trained on state-of-the-art simulations, combining the information from multiple channels. By using Gaussian sky simulations and Planck SRoll2 simulations, including CMB, noise, and residual instrumental systematic effects, we trained, tested, and validated NN models considering different setups. We inferred the value of τ directly from Stokes Q and U maps at ~4° pixel resolution, without computing angular power spectra. On Planck data, we obtained τ NN = 0.0579 ± 0.0082, which is compatible with current EE cross-spectrum results but with a ~30% larger uncertainty, which can be assigned to the inherent nonoptimality of our estimator and to the retraining procedure applied to avoid biases. While this paper does not improve on current cosmological constraints on τ, our analysis represents a first robust application of NN-based inference on real data, and highlights its potential as a promising tool for complementary analysis of near-future CMB experiments, also in view of the ongoing challenge to achieve the first detection of primordial gravitational waves.

79 ASTRONOMY AND ASTROPHYSICS↗

Experimental Investigation of the Effects of Magnetic Mirrors on Plasma Transport in the Prototype Material Plasma Exposure Experiment

The Prototype Material Plasma Exposure eXperiment (Proto-MPEX) at Oak Ridge National Laboratory is developing a helicon radio frequency (RF) source for plasma production along with microwave electron heating and RF ion heating. Proto-MPEX has several magnetic mirrors that affect plasma transport. The magnetic field near the helicon source is ~ 0.05 T, and the peak magnetic field in Proto-MPEX is ~ 1.8 T, which results in a large magnetic well for particles sourced at the helicon transporting toward the target region. Keeping the helicon source field and the target field constant, experiments have been conducted by methodically changing the magnetic field, at a local axial location, within the source and the target. Plasma flow measurements using Mach probes have shown a decrease in the flow as a function of the magnetic mirror ratio. Plasma flows were further investigated with ion cyclotron resonant heating (ICH). Results with the addition of ICH measured upstream of the antenna have shown a decrease in Mach number as a function of mirror ratio when compared to helicon discharges. Such flow behavior demonstrated slowing down of the plasma due to the increased reverse plasma flow toward the helicon plasma source. However, in high magnetic fields, when the resonant magnetic field moved away from the ICH antenna, no effects on the plasma flow due to ICH were observed.

Kafle, Nischal↗

SRF-Based Quantum Transduction for Quantum Computing and Sensing

The next groundbreaking frontier in Quantum Information Science (QIS) is the development of low-noise interconnections over fiber optics between superconducting radio-frequency (SRF) quantum devices. High-efficiency microwave-optical transduction serves as a pivotal enabler for distributed quantum computing and sensor networks. This presentation will provide a comprehensive overview of quantum transduction achieved by coupling SRF cavities to electro-optic optical resonators, enabling efficient conversion between microwave and optical photons. This research, supported by the DOE Early Career Research Program, advances technologies for quantum computing and sensing, and complements the mission of the Superconducting Quantum Materials and Systems (SQMS) Center at Fermilab.

Zorzetti, Silvia [Fermilab] (ORCID:000000023208338↗

Superconducting metamaterials - the first step toward a microwave quantum bus

Coherent manipulation of quantum states is at the core of quantum information science (QIS). Many state-of-the-art quantum systems rely on microwave fields for quantum operations. As such, the microwave electromagnetic fields serve as the ideal "quantum bus" to integrate different types of QIS systems into a hybrid quantum system. Superconducting metamaterials are artificial materials consisting of arrays of superconducting resonant microstructures with sizes much smaller than the microwave wavelengths of interest. Superconducting metamaterials are a strong candidate medium for the microwave quantum bus, because the effective impedance, field distributions, and frequency response can all be controlled by engineering the microstructures, electrical bias, and magnetic flux while maintaining extremely low loss. In this project, we investigate the fundamental unit of a superconducting metamaterial - a resonator with physical dimensions much smaller than the microwave wavelengths - using NbTiN as the working superconductor, whose high operating temperatures and magnetic fields are desirable attributes for compatibility with a wide variety of quantum systems. We first studied the properties of sputtered NbTiN thin films by correlating the film thickness with the normal state resistivity, superconducting transition temperature, and resonances of transmission line resonators made from these films. We developed a process flow and designed a coplanar waveguide platform for studying small resonators. The platform significantly shortens the turnaround times of the resonator fabrication and testing cycles. Several resonators with different designs were fabricated and tested at 4 Kelvin. Resonances were observed in some resonator testers. Potential paths for improvements and future directions are discussed.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Deepest sensitivity to wavelike dark photon dark matter with superconducting radio frequency cavities

Wavelike, bosonic dark matter candidates like axions and dark photons can be detected using microwave cavities known as haloscopes. Traditionally, haloscopes consist of tunable copper cavities operating in the TM 010 mode, but ohmic losses have limited their performance. In contrast, superconducting radio frequency (SRF) cavities can achieve quality factors of ∼ 10 10 , perhaps 5 orders of magnitude better than copper cavities, leading to more sensitive dark matter detectors. In this paper, we first derive that the scan rate of a haloscope experiment is proportional to the loaded quality factor Q L , even if the cavity bandwidth is much narrower than the dark matter halo line shape. We then present a proof-of-concept search for dark photon dark matter using a nontunable ultrahigh-quality SRF cavity. We exclude dark photon dark matter with kinetic mixing strengths of χ > 1.5 × 10 − 16 for a dark photon mass of m A ′ = 5.35 μ eV , achieving the deepest exclusion to wavelike dark photons by almost an order of magnitude. Published by the American Physical Society 2024

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Commercially Fabricated Antenna-Coupled Transition Edge Sensor Bolometer Detectors for Next-Generation Cosmic Microwave Background Polarimetry Experiment

We report on the development of commercially fabricated multi-chronic antenna-coupled transition edge sensor (TES) bolometer arrays for cosmic microwave background (CMB) polarimetry experiments. The orders of magnitude increase in detector count for next-generation CMB experiments require a new approach in detector wafer production to increase fabrication throughput. Here, we describe collaborative efforts with a commercial superconductor electronics fabrication facility (SeeQC, Inc.) to fabricate antenna-coupled TES bolometer detectors. We have successfully fabricated an operational dual-polarization, dichroic sinuous antenna-coupled TES detector array on a 150-mm-diameter wafer. The fabricated detector arrays have average yield of 95% and excellent uniformity across the wafer. Both RF characteristics and TES bolometer properties are suitable for CMB observations. We successfully fabricated different types of TES bolometers optimized for frequency multiplexing readout, time-domain multiplexing readout, and microwave SQUID multiplexing readout. We also demonstrated high production throughput. We discuss the motivation, design considerations, fabrication processes, test results, and how industrial detector fabrication could be a path to fabricate hundreds of detector wafers for future CMB polarimetry experiments.

47 OTHER INSTRUMENTATION↗

Novel frequency tunable systems for superconducting cavities (Abbreviated Report)

Ultra-low loss microwave resonant cavities are the backbone of quantum information science (QIS) and axion/dark matter detection (ADMX), but one of the challenges in developing 3D cavity systems has been finding a tuning mechanism that does not drastically reduce the cavity quality factor (Q) but still provides a large operating bandwidth. To alleviate this limitation, we proposed to fabricate a high-Q, 3D microwave cavity with an integrated hybrid mechanical/electrical tuning scheme to achieve both coarse and rapid fine tuning. We implemented two tuning schemes: one using a shift in kinetic inductance and one utilizing mechanical motion. We found that the kinetic inductance method did not yield any tunability in the cavity mode, but the mechanical adjustment successfully moved the cavity resonance. The quality factors obtained were lower than originally proposed, but there is potential to improve the design on further iterations.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Bond Length Alternation and Internal Dynamics in Model Aromatic Substituents of Lignin

In this report broadband microwave spectra were recorded over the 2-18 GHz frequency range for a series of four model aromatic components of lignin; namely, guaiacol (ortho-methoxy phenol, G), syringol (2,6-dimethoxy phenol, S), 4-methyl guaiacol (MG), and 4-vinyl guaiacol (VG), under jet-cooled conditions in the gas phase. Using a combination of 13 C isotopic data and electronic structure calculations, distortions of the phenyl ring by the substituents on the ring are identified. In all four molecules, the r C(1)-C(6) bond between the two substituted C-atoms lengthens, leading to clear bond alternation that reflects an increase in the phenyl ring resonance structure with double bonds at r C(1)-C(2) , r C(3)-C(4) and r C(5)-C(6) . Syringol, with its symmetric methoxy substituents, possesses a microwave spectrum with tunneling doublets in the a-type transitions associated with H-atom tunneling. These splittings were fit to determine a barrier to hindered rotation of the OH group of 1975 cm -1 , a value nearly 50% greater than that in phenol, due to the presence of the intramolecular OH…OCH 3 H-bonds at the two equivalent planar geometries. In 4-methyl guaiacol, methyl rotor splittings are observed and used to confirm and refine an earlier measurement of the three-fold barrier V 3 = 67 cm -1 . Finally, 4-vinyl guaiacol shows transitions due to two conformers differing in the relative orientations of the vinyl and OH groups.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Four-year Cosmology Large Angular Scale Surveyor (CLASS) Observations: On-sky Receiver Performance at 40, 90, 150, and 220 GHz Frequency Bands

The Cosmology Large Angular Scale Surveyor (CLASS) observes the polarized cosmic microwave background (CMB) over the angular scales of 1° ≲ θ ≤ 90° with the aim of characterizing primordial gravitational waves and cosmic reionization. We report on the on-sky performance of the CLASS Q-band (40 GHz), W-band (90 GHz), and dichroic G-band (150/220 GHz) receivers that have been operational at the CLASS site in the Atacama desert since 2016 June, 2018 May, and 2019 September, respectively. We show that the noise-equivalent power measured by the detectors matches the expected noise model based on on-sky optical loading and lab-measured detector parameters. Using Moon, Venus, and Jupiter observations, we obtain power to antenna temperature calibrations and optical efficiencies for the telescopes. From the CMB survey data, we compute instantaneous array noise-equivalent-temperature sensitivities of 22, 19, 23, and 71 $\mu {{\rm{K}}}_{\mathrm{cmb}}\sqrt{{\rm{s}}}$ for the 40, 90, 150, and 220 GHz frequency bands, respectively. These noise temperatures refer to white noise amplitudes, which contribute to sky maps at all angular scales. Future papers will assess additional noise sources impacting larger angular scales.

Observational cosmology↗

Measurements of the temperature and $E$-mode polarization of the cosmic microwave background from the full 500-square-degree SPTpol dataset

Using the full four-year SPTpol 500 deg 2 dataset in both the 95 and 150 GHz frequency bands, we present measurements of the temperature and E-mode polarization of the cosmic microwave background (CMB), as well as the E-mode polarization autopower spectrum (EE) and temperature-E-mode cross-power spectrum (TE) in the angular multipole range 50 < ℓ < 8000. We find the SPTpol dataset to be self-consistent, passing several internal consistency tests based on maps, frequency bands, bandpowers, and cosmological parameters. The full SPTpol dataset is well-fit by the ΛCDM model, for which we find H 0 = 70.48 ± 2.16 km s -1 Mpc -1 and Ω m = 0.271 ± 0.026, when using only the SPTpol data and a Planck-based prior on the optical depth to reionization. The ΛCDM parameter constraints are consistent across the 95 GHz-only, 150 GHz-only, TE-only, and EE-only data splits. Between the ℓ < 1000 and ℓ > 1000 data splits, the ΛCDM parameter constraints are borderline consistent at the ∼2σ level. This consistency improves when including a parameter A L , the degree of lensing of the CMB inferred from the smearing of acoustic peaks. When marginalized over A L , the ΛCDM parameter constraints from SPTpol are consistent with those from Planck. In conclusion, the power spectra presented here are the most sensitive measurements of the lensed CMB damping tail to date for roughly ℓ > 1700 in TE and ℓ > 2000 in EE.

79 ASTRONOMY AND ASTROPHYSICS↗

Optical Design and Characterization of 40-GHz Detector and Module for the BICEP Array

Families of cosmic inflation models predict a primordial gravitational-wave background that imprints B-mode polarization pattern in the cosmic microwave background (CMB). High-sensitivity instruments with wide frequency coverage and well-controlled systematic errors are needed to constrain the faint B-mode amplitude. We have developed antenna-coupled transition edge sensor arrays for high-sensitivity polarized CMB observations over a wide range of millimeter-wave bands. BICEP array, the latest phase of the BICEP/Keck experiment series, is a multi-receiver experiment designed to search for inflationary B-mode polarization to a precision σ(r) between 0.002 and 0.004 after 3 full years of observations, depending on foreground complexity and the degree of lensing removal. We describe the electromagnetic design and measured performance of BICEP array’s low-frequency 40-GHz detector, their packaging in focal plane modules, and optical characterization including efficiency and beam matching between polarization pairs. We summarize the design and simulated optical performance, including an approach to improve the optical efficiency due to mismatch losses. Here, we report the measured beam maps for a new broadband corrugation design to minimize beam differential ellipticity between polarization pairs caused by interactions with the module housing frame, which helps minimize polarized beam mismatch that converts CMB temperature to polarization (T→P) anisotropy in CMB maps.

47 OTHER INSTRUMENTATION↗