Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microfluidics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

rHealth One Demonstration Aboard ISS: A Microfluidic Bioanalyzer Based on Sheath/Hydrodynamic Focusing Flow Cytometry

The Exploration Medical Capability (ExMC) element aims to provide astronauts with the means for their own health monitoring, diagnosis, and treatment during exploration missions. As space flight ventures further from earth, the need for autonomous medical care increases under greater constraints on size, mass, and resources. One pillar for diagnosis that crew would be separated from is laboratory analysis. Even now on ISS, blood samples must be collected and returned to earth for testing. In response, ExMC is assessing how assays for hematology, bone health, radiation exposure etc. could be addressed through commercial-off-the-shelf (COTS) and Small Business Innovation Research (SBIR) funded bioanalyzers that are miniaturizing lab technology. Since missions will reach distances where there are no timely replacements, validation on the International Space Station (ISS) is a necessary part of that assessment. In partnership with NASA Johnson Space Center (JSC) Immunology Lab and the Research Operations and Integration (ROI) element, ExMC conducted a technology demonstration on ISS of the rHEALTH ONE, a flow cytometry based bioanalyzer, to assess future devices based on this design. In flow cytometry, there are predominantly three ways to focus the cells (or particles) into a single file stream: hydrodynamic focusing, microcapillary, and acoustic focusing. The rHEALTH ONE utilizes the commercial standard, sheath-based hydrodynamic focusing. rHEALTH itself represents both a company and a suite of medical tools NASA has funded through SBIR grants towards the development of a promising diagnosis instrument for exploration missions. rHEALTH ONE is the interim version of the technology, functional as a benchtop analyzer and test bed for the next generation of rHEALTH in development. Several modifications were made to the rHEALTH ONE analyzer for operation in microgravity. For function, fluid management was key. A sheath-based analyzer uses sheath fluid to flow the sample, cleaning fluid to prevent biological contamination, and a reservoir to collect the liquid waste. The rHEALTH ONE analyzer uses bottles dependent on gravity to separate the air and liquid pathways and keep the liquids contained. It uses only 1 psig of air pressure to directly push the liquid through the device, requiring little-to-no resistance at inlet and outlet. A microtubing assembly with self-sealing luer connectors was designed – featuring 0.014 mm thick durable medical balloons to hold water inside the supply bottles – to create safe containment and easy access for the crew while maintaining the analyzer’s function. For safety, copper tape was added to the interior of the plastic housing to reduce electromagnetic interference, fluid and electrical connections were secured against vibration and leaks, and gaps were further sealed to ensure containment of the optical block and lasers. Water as the sheath and cleaning fluid and TOX 0 samples were used to reduce the biohazard risk to the crew. In May 2022, European Space Agency astronaut Samantha Cristoforetti demonstrated the rHEALTH ONE aboard ISS for its sample loading, flow cytometry, and data collection capability in microgravity. The JSC Immunology Lab provided flow cytometry expertise, designed the sample test protocol, and manufactured and benchmarked the flight samples on a ‘gold-standard’ flow cytometer. The analyzer was primed with water, purged of air, and four calibration solutions of polystyrene microparticles were tested to characterize its performance. Tightly controlled procedures and excellent execution prevented air bubble interference during air/water separation, fluid transfer, sample mixing and loading. Data showed a slight increase in signal noise on 3 of 5 channels and an anomaly of fluorophores migrating in one sample (confirmed by JSC post-flight). Flight results correctly detected the change in sample, matched the analyzer’s ground performance, and were consistent with the gold-standard’s ground results. Although areas were noted for improvement, these outcomes signified complete mission success.

R. S. Miller↗

Microfluidic liquid-liquid contactor

An assembly comprises a first liquid guide having an inlet, an outlet, and a liquid-conducting layer comprising a first material. The liquid-conducting layer extends between the inlet and the outlet. A second liquid guide has an inlet, an outlet, and a liquid-conducting layer comprising a second material. The liquid-conducting layer extends between the inlet and the outlet. At least a portion of the liquid-conducting layer of the second liquid guide overlaps the liquid-conducting layer of the first liquid guide such that, when a first liquid flows along the liquid-conducting layer of the first liquid guide and a second liquid flows along the liquid-conducting layer of the second liquid guide, the second liquid contacts the first liquid along the portion of the liquid-conducting layer of the second liquid guide that overlaps the liquid-conducting layer of the first liquid guide.

McCulloch, Quinn↗

Gene editing through microfluidic delivery

Gene editing can be performed by introducing gene-editing components into a cell by mechanical cell disruption. Related apparatus, systems, techniques, and articles are also described. The methods and systems of the invention solve the problem of intracellular delivery of gene editing components and gene editing complexes to target cells. The results described herein indicate that delivery of gene editing components, e.g., protein, ribonucleic acid (RNA), and deoxyribonucleic acid (DNA), by mechanical disruption of cell membranes leads to successful gene editing. Because intracellular delivery of gene editing materials is a current challenge, the methods provide a robust mechanism to engineer target cells without the use of potentially harmful viral vectors or electric fields.

Sharei, Armon R.↗

Lattice microfluidics

An engineered unit cell is disclosed for flowing a fluid therethrough in three dimensions. The unit cell may have a substrate with a plurality of flow channels around and between struts formed within the substrate. The struts may each be formed with a desired shape and orientation within the substrate to achieve a desired degree of fluid flow through the flow channels, in each of one of three dimensions, through the unit cell.

Deotte, Joshua R.↗

Microfluidic aspirator and multi-purpose flow sensor and methods of making and using the same

Devices that include a liquid chamber including at least two ports, wherein the opening of a first port is larger than the opening of a second port, an air chamber including at least one port, and a membrane located between the liquid chamber and the air chamber, and a pressure sensor coupled to the port in the air chamber are provided. Systems including the disclosed devices are also provided. The systems include liquid in the liquid chamber of the device. Methods of using the devices and systems include measuring one or more properties of a liquid by flowing the liquid through the liquid chamber of the system and measuring the pressure produced due to the difference in size of the ports in the liquid chamber.

42 ENGINEERING↗

Porous membrane enabled mass spectrometry characterization of microfluidic devices

A system for sampling a liquid includes a sample fluid conduit including a membrane having pores. The membrane prevents the passage of the sample liquid through the pores at a first pressure of the sample liquid in the sample fluid conduit. A surface sampling capture probe has a distal end. The capture probe includes a solvent supply conduit and a solvent exhaust conduit. A solvent composition flowing at the distal end of the capture probe establishes a liquid junction with the membrane and establishes a second pressure within the liquid junction at the membrane. The second pressure is lower than the first pressure. Sample liquid will be drawn through the pores of the membrane by the second pressure at the liquid junction. A method for sampling a liquid and for performing chemical analysis on a liquid are also disclosed.

Cahill, John F.↗

Open-top microfluidic devices and methods for simulating a function of a tissue

A device for simulating a function of a tissue includes a first structure, a second structure, and a membrane. The first structure defines a first chamber. The first chamber includes a matrix disposed therein and an opened region. The second structure defines a second chamber. The membrane is located at an interface region between the first chamber and the second chamber. The membrane includes a first side facing toward the first chamber and a second side facing toward the second chamber. The membrane separates the first chamber from the second chamber.

Varone, Antonio↗

Modular, disposable 3D printed microfluidic membrane system for separation and purification

The present disclosure relates to a membrane extraction apparatus for extracting a component from a first liquid. The apparatus may incorporate a housing comprised of first and second mating housing halves, with each housing half having an open faced channel formed therein such that the channels at least partially overlay one another when the two housing halves are secured together. A membrane filter is disposed between the two housing halves to overlay the open faced channels. The membrane filter extracts the component from the first liquid and transfers the component into the second liquid as the first and second liquids flow through the first and second housing halves.

Servis, Anna G.↗

Capillary barriers for staged loading of microfluidic devices

Various aspects of the present disclosure are directed toward methods and apparatuses for interacting a first liquid and a second liquid in one or more fluidic channels of a capillary structure. The methods and apparatuses can include providing at least one capillary barrier that positions a meniscus of the first liquid at a fluid-interface region using capillary forces within the capillary structure. Additionally, a path is provided along one of the channels for the second liquid to flow toward the fluid-interface region. Additionally, gas pressure is released, via a gas-outflow port, from the fluid-interface region while flow of the first liquid is arrested. Further, the first liquid and the second liquid contact in the fluid-interface region with the capillary barrier holding the first liquid at the fluid-interface region.

Santiago, Juan G.↗

Porous membrane enabled mass spectrometry characterization of microfluidic devices

A system for sampling a liquid includes a sample fluid conduit including a membrane having pores. The membrane prevents the passage of the sample liquid through the pores at a first pressure of the sample liquid in the sample fluid conduit. A surface sampling capture probe has a distal end. The capture probe includes a solvent supply conduit and a solvent exhaust conduit. A solvent composition flowing at the distal end of the capture probe establishes a liquid junction with the membrane and establishes a second pressure within the liquid junction at the membrane. The second pressure is lower than the first pressure. Sample liquid will be drawn through the pores of the membrane by the second pressure at the liquid junction. A method for sampling a liquid and for performing chemical analysis on a liquid are also disclosed.

Cahill, John F.↗