Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Microchannel”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Simultaneous measurements of velocity and pressure fields in subsonic and supersonic flows through image-intensified detection of laser-induced fluorescence

An optical technique is presented for combined, spatially resolved measurements of two-dimensional velocity and pressure fields in compressible flows. The single-mode frequency of an argon laser is fixed in the wing of an absorption line of iodine molecules, seeded in an underexpanded round jet of nitrogen gas. The emitted fluorescence, being proportional to the amount of absorbed radiation and hence the absorption line-shape function, is detected with an intensified 100 x 100 photodiode array camera. A single-microchannel-plate image intensifier is fiber-optically coupled to the array in order to improve time resolution and SNR. Three components of the velocity vector in a cross-sectional plane are sequentially probed with four laser sheets from three different directions. By shifting the laser frequency in one of the sheets with a piezo-tuned intra-cavity etalon, the slope of the absorption line can be measured in situ in order to provide the required scaling factor for the velocity measurement. With its short measurement times of less than 250 ms, this method is well suited for blow-down wind tunnel experiments.

Hiller, B.↗

Operational characteristics of Wedge and Strip image readout systems

Application of the Wedge and Strip readout system in microchannel plate detectors for the Extreme Ultraviolet Explorer and FAUST space astronomy programs is discussed. Anode designs with high resolution (greater than 600 x 600 pixels) in imaging and spectroscopy applications have been developed. Extension of these designs to larger formats (100 mm) with higher resolution (3000 x 3000 pixels) are considered. It is shown that the resolution and imaging are highly stable, and that the flat field performance is essentially limited by photon statistics. Very high speed event response has also been achieved with output pulses having durations of less than 10 nanoseconds.

Siegmund, O. H. W.↗

Research relative to high resolution camera on the advanced X-ray astrophysics facility

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the x-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft x-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15 ergs sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Source record↗

Cometary spectroscopy

The spectroscopic and morphological characteristics of comets over a wide range of heliocentric distances are investigated as they may suggest or constrain models of cometary formation environments and evolution. This program also contributes to the understanding of the general comet population with which spacecraft data will be compared. Long slit spectra and direct images of all observable comets (M2<18) are obtained on a monthly basis with either a UV sensitive microchannel plate or a red sensitive CCD spectrograph/camera. Scale lengths of the principal emission of OH, NH, CN, C3, C2, NH2 and OI different comets can be compared. The direct images are used for studies of dust anisotropy which can provide data on the spin vector and gross surface morphology.

Larson, S.↗

X-ray instrumentation in astronomy; Proceedings of the Meeting, Cannes, France, December 2-4, 1985

Recent developments in X-ray and EUV astronomical instrumentation are discussed in reviews and reports. Topics examined include optical systems for the NASA Advanced X-ray Astrophysics Facility (AXAF), specialized X-ray systems, advanced X-ray optics, gas-filled X-ray detectors, instrumentation for spectrometry on AXAF, X-ray and EUV spectrometers, microchannel plate detectors, and solid-state detectors.

Culhane, J. L.↗

The Advanced X-ray Astrophysics Facility high resolution camera

The HRC (High Resolution Camera) is a photon counting instrument to be flown on the Advanced X-Ray Astrophysics Facility (AXAF). It is a large field of view, high angular resolution, detector for the X-ray telescope. The HRC consists of a CsI coated microchannel plate (MCP) acting as a soft X-ray photocathode, followed by a second MCP for high electronic gain. The MCPs are readout by a crossed grid of resistively coupled wires to provide high spatial resolution along with timing and pulse height data. The instrument will be used in two modes, as a direct imaging detector with a limiting sensitivity of 10 to the -15th ergs/sq cm sec in a 10 to the 5th second exposure, and as a readout for an objective transmission grating providing spectral resolution of several hundreds to thousands.

Murray, Stephen S.↗

Statistical performance of the intensified charged coupled device

The first analysis of the statistical performance of the intensified charge coupled device (CCD) is presented. The Poisson statistics of the arriving photons, the exponential pulse height distribution of the microchannel plate in the image intensifier, and the effects of discrete digitization of the charge in reading the CCD are included. A range of intensifier gains from the high levels that permit pulse counting to the low levels that can be used with the accumulation of charge on the CCD is considered. As a tool for this analysis, an analytical model of the performance of the detector system that is generally useful for predicting many aspects of system performance under a wide range of conditions is developed. The statistical penalty for operating the intensified CCD in the charge accumulation mode is not severe, and in some applications it may be desirable to accept this penalty to gain the advantages of increased dynamic range through charge accumulation. This investigation has revealed no pathological aspects of the operation of the detector system.

Sandel, B. R.↗

High efficiency photon counting detectors for the FAUST Spacelab far ultraviolet astronomy payload

The performances of sealed tube microchannel-plate position sensitive detectors having transmission CsI photocathodes or opaque CsI photocathodes are compared. These devices were developed for the FAUST Spacelab payload to accomplish imaging surveys in the band between 1300 A and 1800 A. It is demonstrated that photocathode quantum efficiencies in excess of 40 percent at 1216 A have been achieved with the transmission and the opaque CsI photocathodes. The effect of the photoelectron trajectory on the spatial resolution is assessed. Spatial resolution of less than 70 microns FWHM has been obtained and is maintained up to event rates of 50,000/sec. Background rates of 0.55 events sq cm per sec have been achieved and low distortion (less than 1 percent) imaging has been demonstrated.

Siegmund, O. H. W.↗

Wedge and strip image readout systems for photon-counting detectors in space astronomy

EUV and far UV applications of wedge and strip anodes in photon-counting microchannel plate detector systems are discussed in light of performance data obtained as a result of EUV Explorer spacecraft open face detector and FAUST-Spacelab far UV sealed tube sensor calibrations. CsI quantum detection efficiencies of about 80 percent at 114 A and about 40 percent at 600 and 1300 A have been achieved; a position sensitivity of less than 10 microns is demonstrated, and the position resolution, image linearity, background rate, and flat-field characteristics are discussed.

Siegmund, O. H. W.↗

A spectrometer to measure the diffuse, astronomical extreme ultraviolet background

The present grazing incidence spectrometer for measuring the diffuse astronomical background between 80 and 650 A uses a wire grid collimator to define a 40-arcmin by 15-deg field of view. After passing through the collimator, radiation impinges on an array of plane reflection gratings. An array of mirrors then focuses the diffracted light through a thin filter onto a microchannel plate detector. The resulting system focuses to a few arcmin and produces spectra with 10 to 20 A resolution. Performance characteristics of the spectrometer are discussed.

Labov, Simon↗

The design of an echelle spectrometer for diffuse extreme ultraviolet/far ultraviolet astronomy

The novel, relatively high-resolution nebular spectrometer design presented incorporates a mechanical precollimator with an objective echelle grating that proceeds to a cross-dispensing Wadsworth configuration; the minimum feasible number of reflections is employed in order to maximize EUV sensitivity. The configuration, which is noted to be capable of yielding a comparatively large field of view for optimal diffuse emission sensitivity, is compact and employs conventionally fabricated optical components and available microchannel plate detectors. The sensitivities obtainable approach the limit stipulated by Liouville's theorem.

Martin, Christopher↗

Experimental tests of a toroidal electrostatic analyzer

A toroidal electrostatic analyzer of a design suitable for space plasma instrumentation has been constructed and tested. Experimental results are compared with second-order ion optical theory and are in good agreement. Verifying the ion optics of the toroid was simplified by use of a position-sensing microchannel-plate detector mounted on a positioning system with three translational degrees of freedom located at the toroid exit. The toroidal analyzer described here is the first optical element in a fully toroidal mass spectrograph intended for analysis of kilovolt magnetospheric plasmas.

Young, D. T.↗

Hybrid X-ray telescope systems

It has been known for some time that glancing incidence X-ray optics have sharply peaked point response functions. The spatial resolution of Wolter X-ray telescope systems is frequently limited by the performance characteristics of the X-ray detector rather than by the optics, even when high resolution detectors such as photographic emulsions are used. This problem becomes even more severe when it is desirable to take advantage of the high sensitivity and broad wavelength response afforded by modern solid state detectors such as charge coupled devices or multi-anode microchannel arrays. Results of theoretical investigations of methods for increasing the telescope plate scale by the use of glancing incidence hyperboloid/ellipsoid X-ray microscope optics and normal incidence contoured layered synthetic microstructure optics for coupling the Wolter mirrors to the detector are reported. The relative merits of the different hybrid X-ray telescope systems which result will be discussed. Considerations will be made concerning applications of these systems to high resolution imagery and spectroscopy of astronomical X-ray/XUV sources.

Shealy, David L.↗

The off-axis channel macroplate

High-gain microchannel plates (MCPs) which utilize curvature of the channel to inhibit ion feedback (C-plate MCRs) have demonstrated excellent performance characteristics. However, C-plate MCPs are at present costly to fabricate, and the shearing process used to curve the channels produces a low device yield. Described here is a totally new type of high-gain MCP structure in which each channel has an axially symmetric curvature. Initial tests of proof-of-concept units of these MCPs with 75-micron-diameter channels (macroplates) suggest that their performance characteristics have the potential to be equal to those of a C-plate MCP while the fabrication process is no more complex than that of a conventional straight-channel MCP.

Timothy, J. Gethyn↗

The soft X-ray/EUV calibration facility at the University of Colorado

The components of the calibration facility at the University of Colorado are described. The system is capable of analyzing the performance of optical components in the wavelength range from 2.7 to 2500 A. The system uses two light sources: a water-cooled hollow cathode gas discharge source and a soft X-ray source. The 2.2-m grazing incidence monochrometer, slits, large chamber, and computer-controlled manipulator are examined. The NBS aluminum oxide photodiode, a flowing gas proportional counter, and an imaging microchannel plate device are employed to detect the light. The optics, detectors, and data acquisition system are computer controlled. The facility is applicable for evaluating the performance of diffraction gratings, multilayer mirrors, reflective coatings, spectrographs, surface roughness scattering, and absolute detector efficiencies. Examples demonstrating the capabilities of the facility and a diagram of the facility are presented.

Windt, David L.↗

The advanced X-ray astrophysics facility - An overview

This paper presents an overview of NASA's Advanced X-Ray Astrophysics Facility (AXAF), which is planned for launch in the 1990s and is expected to operate in space for at least 15 years. The design of the X-ray telescope is discussed and the instruments that may fly at the start of the AXAF mission, the principal investigator of each instrument, and the instrument performance parameters are listed. The AXAF instruments will include low-energy and high-energy transimission gratings, a Bragg crystal spectrometer, CCD imagers, an X-ray calorimeter, and a microchannel plate imager. The long lifetime of the AXAF will make it possible to follow up on the HEAO-2/Einstein results, the more recent X-ray observations performed by European and Japanese satellites, and the future ROSAT all-sky survey. The long lifetime of the AXAF, together with the servicing capability that will be offered by the Space Station, will also provide the opportunity of incorporating other instruments into the observatory.

Weisskopf, Martin C.↗

The AXAF high resolution camera (HRC) and its use for observations of distant clusters of galaxies

The High Resolution Camera being developed for AXAF is briefly described, comparing it with its predecessor, the Einstein HRI, and providing preliminary performance data. The HRC is a 10 cm x 10 cm detector with CsI coated microchannel plates providing a large field of view device with high X-ray quantum efficiency. The overall sensitivity of the HRC on AXAF is about 50 times that of the Einstein HRI. An example of the power of this instrument is discussed in the context of studies of distant clusters of galaxies. The HRC can detect individual galaxies in a cluster of redshift 1, if they are similar to the early-type galaxies in nearby clusters that have been observed by the Einstein instruments. The HRC will be used to measure the luminosity function for clusters of galaxies as a function of their distance up to a redshift of 1. This will allow observation of evolutionary effects in clusters as a whole, while the detection of individual galaxies will permit studies of galaxy evolution in a cluster environment.

Murray, S. S.↗

High-resolution pulse-counting array detectors for imaging and spectroscopy at ultraviolet wavelengths

The performance characteristics of multianode microchannel array (MAMA) detector systems which have formats as large as 256 x 1024 pixels and which have application to imaging and spectroscopy at UV wavelengths are evaluated. Sealed and open-structure MAMA detector tubes with opaque CsI photocathodes can determine the arrival time of the detected photon to an accuracy of 100 ns or better. Very large format MAMA detectors with CsI and Cs2Te photocathodes and active areas of 52 x 52 mm (2048 x 2048 pixels) will be used as the UV solar blind detectors for the NASA STIS.

Timothy, J. Gethyn↗