Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Medical Imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Noninvasive liquid level sensing with laser generated ultrasonic waves

This article proposes a noninvasive liquid level sensing technique using laser-generated ultrasound waves for nuclear power plant applications. Liquid level sensors play an important role of managing the coolant system safely and stably in the plant structure. Current sensing techniques are mostly intrusive, performing inside the fluidic structure, which is disadvantageous in terms of the regular maintenance of the plant system. Furthermore, typical intrusive sensors do not perform stably under varying environmental conditions such as temperature and radiation. In this study, sensing units are attached to the outer surface of a liquid vessel to capture guided ultrasound waves in a nonintrusive manner. The signal intensity of the guided wave dissipates when the signal interacts with the internal liquid media. The sensing mechanism is mathematically expressed as an index value to correlate the liquid level with the sensor signal. For the acoustic wave generation, laser-generated ultrasound was adopted instead of using typical contact type transducers. Following the simulation validation of the proposed concept, the performance of the developed sensor was confirmed through experimental results under elevated liquid temperature conditions. Finally, the nonlinear multivariable regression exhibited the best-fit to the datasets measured under the variable liquid level and temperature conditions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Extraction and selective promotion of zero-group velocity and cutoff frequency resonances in bi-dimensional waveguides using the electromechanical impedance method

This study showcases the electromechanical impedance (EMI) technique for extracting and promoting zero-group velocity (ZGV) and cutoff frequency resonances in a waveguide structure. Here, we identify the mechanisms of multiple resonances in the EMI spectra via a wave propagation perspective. Both simulation and experiments reveal the fact that sharp resonances in the conductance spectra are associated with either ZGV or cutoff frequency points. Consequently, we design four test configurations to enhance local resonances by aligning induced motions with considered mode shapes. Reasonable agreement between simulation and experiment results is observed. We evaluate the performance of considered configurations in terms of mode enhancement, and configurations that can selectively promote certain mode families are summarized. This study also shines the light on the EMI technique for quantitative non-destructive evaluation (NDE) by potentially supporting the inverse characterization of mechanical properties of host structures.

42 ENGINEERING↗

Vessel Rupture Thresholds for Vessel–Bubble Interactions Using an Earthworm Vasculature Model

Intravenous microbubble oscillation in the presence of ultrasound has the potential to yield a wide range of therapeutic benefits. However, the likelihood of vessel damage caused by mechanical effects has not been quantified as a function of the numerous important parameters in therapeutic ultrasound procedures. In this study, we examined the effects of microbubbles injected into the vasculature of the earthworm. It was found that the elastic properties of earthworm blood vessels are similar to those of arteries in older humans, and that earthworms are well suited to the large number of experiments necessary to investigate safety of procedures involving microbubble oscillation in sonicated vessels. Microbubbles were infused into earthworm vessels, and the rupture time during sonication was recorded as a function of ultrasound frequency, pulse repetition frequency and acoustic pressure. A modified mechanical index (MMI) was defined that successfully captured the trends in rupture probability and rupture time for the different parameter values, creating a database of vessel rupture thresholds. In the absence of bubbles, the product of MMI squared and rupture time was approximately constant, indicating a possible radiation-force effect. Here, the MMI was an effective correlating parameter in the presence of bubbles, though the mathematical dependence is not yet apparent. The results of the study are expected to be valuable in designing more refined studies in vertebrate models, as well as informing computational models.

59 BASIC BIOLOGICAL SCIENCES↗

Application of multi-method-multi-model inference to radiation related solid cancer excess risks models for astronaut risk assessment

The impact of including model-averaged excess radiation risks (ER) into a measure of radiation attributed decrease of survival (RADS) for the outcome all solid cancer incidence and the impact on the uncertainties is demonstrated. It is shown that RADS applying weighted model averaged ER based on AIC weights result in smaller risk estimates with narrower 95% CI than RADS using ER based on BIC weights. Further a multi-method-multi-model inference approach is introduced that allows calculating one general RADS estimate providing a weighted average risk estimate for a lunar and a Mars mission. For males the general RADS estimate is found to be 0.42% (95% CI: 0.38%; 0.45%) and for females 0.67% (95% CI: 0.59%; 0.75%) for a lunar mission and 2.45% (95% CI: 2.23%; 2.67%) for males and 3.91% (95% CI: 3.44%; 4.39%) for females for a Mars mission considering an age at exposure of 40 years and an attained age of 65 years. It is recommended to include these types of uncertainties and to include model-averaged excess risks in astronaut risk assessment.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Gallium oxide semiconductor-based large volume ultrafast radiation hard spectroscopic scintillators

We report on the development of the first-ever inorganic radiation-hard moisture-insensitive large volume spectroscopic semiconductor-based scintillator with less than 2 ns decay time and light yields as high as 8000 ph/MeV. Despite extensive research into scintillator materials, the quest for an ideal scintillator combining ultrafast decay times (akin to BaF 2 and Yb-doped scintillators such as Lu 2 O 3 :Yb), high light yields (exceeding 2000 photons per MeV), spectroscopic capabilities, and exceptional radiation hardness remain unfulfilled. In this study, we demonstrate and report for the first time the viability of large-volume (up to 20 mm thickness) gallium oxide (β-Ga 2 O 3 ) semiconductor-based scintillators for applications requiring these properties. These β-Ga 2 O 3 scintillators were grown using the fast turnaround (~2 days) crucible-free optical float zone (FZ) technique. The high light yield and ultrafast decay time of these high-purity n-type semiconductors with free carrier concentration of 6 × 10 17 cm –3 are attributed to native defects, specifically oxygen vacancies (V O ) and gallium–oxygen vacancy pairs (V Ga –V O ), generated during optimized FZ growth. The ultrafast decay, along with high light yield, enables excellent timing resolution and high count rate detection for applications like time-of-flight positron emission tomography, physics experiments, and nuclear safety. The radiation hardness of these devices has been documented in a separate publication.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗