Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement_method”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Polar Balloon Experiment for Astrophysics Research (Polar BEAR)

A new balloon experiment is proposed for a long duration flight around the North Pole. The primary objective of the experiment is to measure the elemental energy spectra of high-energy cosmic rays in the region up to 10(exp 15) eV. The proposed instrument involves the combination of a large collecting area (approximately 1 x 1 square m) KLEM (Kinematic Lightweight Energy Meter) device with an ionization calorimeter having a smaller collecting area (approximately 0.5 x 0.5 square m) and integrated beneath the KLEM apparatus. This combination has several important advantages. Due to the large aperture (greater than 2 square m sr) of the KLEM device a large exposure factor can be achieved with a long duration balloon flight (2-4 weeks). The calorimeter will collect about 10% of the events already registered by KLEM and provide effective cross-calibration for both energy measurement methods. Details of the experiment and its astrophysical significance will be presented.

Bashindzhagyan, G.↗

Non-Destructive Evaluation Method and Apparatus for Measuring Acoustic Material Nonlinearity

An acoustic non-linearity parameter (beta) measurement method and system for Non-Destructive Evaluation (NDE) of materials and structural members obviates the need for electronic calibration of the measuring equipment. Unlike known substitutional measuring techniques requiring elaborate calibration procedures, the electrical outputs of the capacitive detector of a sample with known beta and the test sample of unknown beta are compared to determine the unknown beta. In order to provide the necessary stability of the present-inventive reference-based approach, the bandpass filters of the measurement system are maintained in a temperature-controlled environment, and the line voltage supplied to said amplifiers is well-regulated.

William T Yost↗

Early Warning Signs

Developed under an SBIR contract with Goddard Space Flight Center, Jentek Sensors, Inc.'s GridStation Measurement System provides thermal spray coating thickness, porosity, and age degradation monitoring capability using comformable inductive and capacitative sensors and model-based grid measurement methods for data interpretation.

Source record↗

Shear-Sensitive Liquid Crystal Coating Method: Surface-Inclination Effects on Shear Vector Measurements

The shear-sensitive liquid crystal coating (SSLCC) method is an image-based technique for both visualizing dynamic surface-flow phenomena, such as transition and separation, and for measuring the continuous shear-stress vector distribution acting on an aerodynamic surface. Under proper lighting and viewing conditions (discussed below), the coating changes color in response to an applied aerodynamic shear. This color-change response is continuous and reversible, with a response time of milliseconds, and is a function of both the shear magnitude and the shear vector orientation relative to the observer. The liquid crystal phase of matter is a weakly-ordered, viscous, non-Newtonian fluid state that exists between the nonuniform liquid phase and the ordered solid phase of certain organic compounds. Cholesteric liquid crystal compounds possess a helical molecular arrangement that selectively scatters white light, incident along the helical axis, as a three-dimensional spectrum. This property is linked to the helical pitch length, which is within the range of wavelengths in the visible spectrum. The pitch length, and hence the wavelength of the scattered light, is influenced by shear stress normal to the helical axis. This unique optical property produces a measurable color change in response to an applied shearing force. The full-surface shear stress vector measurement method, developed at NASA-Ames, is schematically illustrated. As with the visualization method, the coated test surface is illuminated from the normal direction with white light and the camera is positioned at an above-plane view angle of approximately 30 deg. Experiments have been initiated at NASA Ames to begin the process of quantifying surface-inclination (surface-curvature) effects on shear vector measurement accuracy. In preliminary experiments, surface-inclination angles theta(sub x), theta(sub y) of 0, +/-5, +/-10, and +/-15 deg were employed. In this arrangement, white-light illumination was positioned normal to the untilted test surface, and the camera above-plane view angle was set at 30 deg relative to the untilted test surface. As can be seen, vector-aligned lambda(sub d) values showed no dependence on theta(sub x) or theta(sub y) for absolute values of these tilt angles is less than or equal to 15 deg. Acquisition and analyses of full-surface color images are presently underway to definitively document the insensitivity limits of the shear vector measurement methodology to surface-slope variations.

Reda, Daniel C.↗

Measurement of Trailing Edge Noise Using Directional Array and Coherent Output Power Methods

The use of a directional (or phased) array of microphones for the measurement of trailing edge (TE) noise is described and tested. The capabilities of this method arc evaluated via measurements of TE noise from a NACA 63-215 airfoil model and from a cylindrical rod. This TE noise measurement approach is compared to one that is based on thc cross spectral analysis of output signals from a pair of microphones placed on opposite sides of an airframe model (COP method). Advantages and limitations of both methods arc examined. It is shown that the microphone array can accurately measures TE noise and captures its two-dimensional characteristic over a large frequency range for any TE configuration as long as noise contamination from extraneous sources is within bounds. The COP method is shown to also accurately measure TE noise but over a more limited frequency range that narrows for increased TE thickness. Finally, the applicability and generality of an airfoil self-noise prediction method was evaluated via comparison to the experimental data obtained using the COP and array measurement methods. The predicted and experimental results are shown to agree over large frequency ranges.

Hutcheson, Florence V.↗

Measurement Of Trailing Edge Noise using Directional Array and Coherent Output Power Methods

The use of a directional array of microphones for the measurement of trailing edge (TE) noise is described. The capabilities of this method are evaluated via measurements of TE noise from a NACA 63-215 airfoil model and from a cylindrical rod. This TE noise measurement approach is compared to one that is based on the cross spectral analysis of output signals from a pair of microphones (COP method). Advantages and limitations of both methods are examined. It is shown that the microphone array can accurately measures TE noise and captures its two-dimensional characteristic over a large frequency range for any TE configuration as long as noise contamination from extraneous sources is within bounds. The COP method is shown to also accurately measure TE noise but over a more limited frequency range that narrows for increased TE thickness. Finally, the applicability and generality of an airfoil self-noise prediction method was evaluated via comparison to the experimental data obtained using the COP and array measurement methods. The predicted and experimental results are shown to agree over large frequency ranges.

Hutcheson, Florence V.↗

Estimation of neutron and other radiation exposure components in low earth orbit

The interaction of high-energy space radiation with spacecraft materials generates a host of secondary particles, some, such as neutrons, are more biologically damaging and penetrating than the original primary particles. Before committing astronauts to long term exposure in such high radiation environments, a quantitative understanding of the exposure and estimates of the associated risks are required. Energetic neutrons are traditionally difficult to measure due to their neutral charge. Measurement methods have been limited by mass and weight requirements in space to nuclear emulsion, activation foils, a limited number of Bonner spheres, and TEPCs. Such measurements have had limited success in quantifying the neutron component relative to the charged components. We will show that a combination of computational models and experimental measurements can be used as a quantitative tool to evaluate the radiation environment within the Shuttle, including neutrons. Comparisons with space measurements are made with special emphasis on neutron sensitive and insensitive devices. c2001 Elsevier Science Ltd. All rights reserved.

STS-57 Shuttle Project↗

The NASA High Intensity Radiated Fields Laboratory

High Intensity Radiated Fields (HIRF) are the result of a multitude of intentional and nonintentional electromagnetic sources that currently exists in the world. Many of today's digital systems are susceptible to electronic upset if subjected to certain electromagnetic environments (EME). Modern aerospace designers and manufacturers increasingly rely on sophisticated digital electronic systems to provide critical flight control in both military, commercial, and general aviation aircraft. In an effort to understand and emulate the undesired environment that high energy RF provides modern electronics, the Electromagnetics Research Branch (ERB) of the Flight Electronics and Technology Division (FETD) conducts research on RF and microwave measurement methods related to the understanding of HIRF. In the High Intensity Radiated Fields Laboratory, the effects of high energy radiating electromagnetic fields on avionics and electronic systems are tested and studied.

Williams, Reuben A.↗

T wave alternans during exercise and atrial pacing in humans

INTRODUCTION: Evidence is accumulating that microvolt T wave alternans (TWA) is a marker of increased risk for ventricular tachyarrhythmias. Initially, atrial pacing was used to elevate heart rate and elicit TWA. More recently, a noninvasive approach has been developed that elevates heart rate using exercise. METHODS AND RESULTS: In 30 consecutive patients with a history of ventricular tachyarrhythmias, the spectral method was used to detect TWA during both atrial pacing and submaximal exercise testing. The concordance rate for the presence or absence of TWA using the two measurement methods was 84%. There was a patient-specific heart rate threshold for the detection of TWA that averaged 100 +/- 14 beats/min during exercise compared with 97 +/- 9 beats/min during right atrial pacing (P = NS). Beyond this threshold, there was a significant and comparable increase in level of TWA with decreasing pacing cycle length and increasing exercise heart rates. CONCLUSIONS: The present study is the first to demonstrate that microvolt TWA can be assessed reliably and noninvasively during exercise stress. There is a patient-specific heart rate threshold beyond which TWA continues to increase with increasing heart rates. Heart rate thresholds for the onset of TWA measured during atrial pacing and exercise stress were comparable, indicating that heart rate alone appears to be the main factor of determining the onset of TWA during submaximal exercise stress.

NASA Discipline Regulatory Physiology↗

Comparison of computer- and human-derived coronary angiographic end-point measures for controlled therapy trials

The Cholesterol Lowering Atherosclerosis Study, a randomized angiographic clinical trial, demonstrated the beneficial effect of niacin/colestipol plus diet therapy on coronary atherosclerosis. Outcome was determined by panel-based estimates (viewed in both still and cine modes) of percent stenosis severity and change in native artery and bypass graft lesions. Computer-based quantitative coronary angiography (QCA) was also used to measure lesion and bypass graft stenosis severity and change in individual frames closely matched in orientation, opacification, and cardiac phase. Both methods jointly evaluated 350 nonoccluded lesions. The correlation between QCA and panel estimates of lesion size was 0.70 (p less than 0.0001) and for change in lesion size was 0.28 (p = 0.002). Agreement between the two methods in classifying lesion changes (i.e., regression, unchanged, or progression) occurred for 60% (210 of 350) of the lesions kappa +/- SEM = 0.20 +/- 0.05, p less than 0.001). The panel identified 442 nonoccluded lesions for which QCA stenosis measurements could not be obtained. Lesions not measurable by QCA included those with stenosis greater than 85% that could not be reliably edge tracked, segments with diffuse or ecstatic disease that had no reliable reference diameter, and segments for which matched frames could not be located. Seventy-nine lesions, the majority between 21% and 40% stenosis, were identified and measured by QCA but were not identified by the panel. This comparison study demonstrates the need to consider available angiographic measurement methods in relation to the goals of their use.

NASA Center JPL↗

Researches on the Piston Ring

In internal combustion engines, steam engines, air compressors, and so forth, the piston ring plays an important role. Especially, the recent development of Diesel engines which require a high compression pressure for their working, makes, nowadays, the packing action of the piston ring far more important than ever. Though a number of papers have been published in regard to researches on the problem of the piston ring, none has yet dealt with an exact measurement of pressure exerted on the cylinder wall at any given point of the ring. The only paper that can be traced on this subject so far is Mr. Nakagawa's report on the determination of the relative distribution of pressure on the cylinder wall, but the measuring method adopted therein appears to need further consideration. No exact idea has yet been obtained as to how the obturation of gas between the piston and cylinder, the frictional resistance of the piston, and the wear of the cylinder wall are affected by the intensity and the distribution of the radial pressure of the piston ring. Consequently, the author has endeavored, by employing an apparatus of his own invention, to get an exact determination of the pressure distribution of the piston ring. By means of a newly devised ring tester, to which piezoelectricity of quartz was applied, the distribution of the radial pressure of many sample rings on the market was accurately determined. Since many famous piston rings show very irregular pressure distribution, the author investigated and achieved a manufacturing process of the piston ring which will exert uniform pressure on the cylinder wall. Temperature effects on the configuration and on the mean spring power have also been studied. Further, the tests were performed to ascertain how the gas tightness of the piston ring may be affected by the number or spring power. The researches as to the frictional resistance between the piston ring and the cylinder wall were carried out, too. The procedure of study, and experiments conducted by the author, on this subject will be fully described in the following paragraphs.

Ehihara, Keikiti↗

System Being Developed to Measure the Rotordynamic Characteristics of Air Foil Bearings

Because of the many possible advantages of oil-free engine operation, interest in using air lubricated foil-bearing technology in advanced oil-free engine concepts has recently increased. The Oil-Free Turbomachinery Program at the NASA Glenn Research Center at Lewis Field has partially driven this recent push for oil-free technology. The program's goal of developing an innovative, practical, oil-free gas turbine engine for aeropropulsion began with the development of NASA's high-temperature solid-lubricant coating, PS304. This coating virtually eliminates the life-limiting wear that occurs during the startup and shutdown of the bearings. With practically unlimited life, foil air bearings are now very attractive to rotating machinery designers for use in turbomachinery. Unfortunately, the current knowledge base of these types of bearings is limited. In particular, the understanding of how these types of bearings contribute to the rotordynamic stability of turbomachinery is insufficient for designers to design with confidence. Recent work in oil-free turbomachinery has concentrated on advancing the understanding of foil bearings. A high-temperature fiber-optic displacement probe system and measurement method were developed to study the effects of speed, load, temperature, and other environmental issues on the stiffness characteristics of air foil bearings. Since high temperature data are to be collected in future testing, the testing method was intentionally simplified to minimize the need for expensive test hardware. The method measures the displacement induced upon a bearing in response to an applied perturbation load. The early results of these studies, which are shown in the accompanying figure, indicate trends in steady state stiffness that suggest stiffness increases with load and decreases with speed. It can be seen, even from these data, that stiffness is not expected to change by orders of magnitude over the normal operating range of most turbomachinery; a promising sign for their eventual integration into oil-free turbomachines. Planned future testing will generate similar plots for stiffness changes with temperature and geometry, as well as damping data. The data collected by this method represent a critical step toward understanding how to successfully apply foil air bearings to future oil-free turbomachinery systems.

Howard, Samuel A.↗

Software Reliability Measurement Experience

In this chapter, we describe a recent study of software reliability measurement methods that was conducted at the Jet Propulsion Laboratory. The first section of the chapter, sections 8.1, summarizes the study, characterizes the participating projects, describes the available data, and summarizes the tudy's results.

Software data execution-based early prediction↗

Measurement of Density, Sound Velocity, Surface Tension, and Viscosity of Freely Suspended Supercooled Liquids

Non-contact methods have been implemented in conjunction with levitation techniques to carry out the measurement of the macroscopic properties of liquids significantly cooled below their nominal melting point. Free suspension of the sample and remote methods allow the deep excursion into the metastable liquid state and the determination of its thermophysical properties. We used this approach to investigate common substances such as water, o-terphenyl, succinonitrile, as well as higher temperature melts such as molten indium, aluminum and other metals. Although these techniques have thus far involved ultrasonic, electromagnetic, and more recently electrostatic levitation, we restrict our attention to ultrasonic methods in this paper. The resulting magnitude of maximum thermal supercooling achieved have ranged between 10 and 15% of the absolute temperature of the melting point for the materials mentioned above. The physical properties measurement methods have been mostly novel approaches, and the typical accuracy achieved have not yet matched their standard equivalent techniques involving contained samples and invasive probing. They are currently being refined, however, as the levitation techniques become more widespread, and as we gain a better understanding of the physics of levitated liquid samples.

Supercooling Liquids↗

Measurements of Turbulent Flow Field in Separate Flow Nozzles with Enhanced Mixing Devices - Test Report

As part of the Advanced Subsonic Technology Program, a series of experiments was conducted at NASA Glenn Research Center on the effect of mixing enhancement devices on the aeroacoustic performance of separate flow nozzles. Initial acoustic evaluations of the devices showed that they reduced jet noise significantly, while creating very little thrust loss. The explanation for the improvement required that turbulence measurements, namely single point mean and RMS statistics and two-point spatial correlations, be made to determine the change in the turbulence caused by the mixing enhancement devices that lead to the noise reduction. These measurements were made in the summer of 2000 in a test program called Separate Nozzle Flow Test 2000 (SFNT2K) supported by the Aeropropulsion Research Program at NASA Glenn Research Center. Given the hot high-speed flows representative of a contemporary bypass ratio 5 turbofan engine, unsteady flow field measurements required the use of an optical measurement method. To achieve the spatial correlations, the Particle Image Velocimetry technique was employed, acquiring high-density velocity maps of the flows from which the required statistics could be derived. This was the first successful use of this technique for such flows, and shows the utility of this technique for future experimental programs. The extensive statistics obtained were likewise unique and give great insight into the turbulence which produces noise and how the turbulence can be modified to reduce jet noise.

Bridges, James↗

Detection of S02 and N02 in Stack Plume by Raman Scattering and Fluorescence

We have been studying laser-Raman radar which can be used as the remote detector of sulfur dioxide concentration in the stack plume of boiler exhaust gas, and some results have been published. In this paper, we report the interference of nitrogen dioxide fluorescence against sulfur dioxide Raman scattering and the measuring method of sulfur dioxide and nitrogen dioxide concentration. In a stack plume, high density dust and high concentration carbon dioxide are included, therefore very strong Mie back-scattering and carbon dioxide Raman scattering are observed. The separation of these scattering signals from sulfur dioxide Raman signal was the first problem for the laser-Raman radar. But, this problem was solved by using the filter which have high resolving power. It is well known that nitrogen dioxide can be excited to emit fluorescence of broad spectrum by blue-green light. The light source of the laser-Raman radar is SH of Nd:YAG laser, and boiler exhaust gas includes several tens ppm of nitrogen dioxide, then the interference of nitrogen dioxide fluorescence brings the error to sulfur dioxide measurement. 'rhe rejection of the interference can be achieved by the subtraction of the nitrogen dioxide fluorescence contribution from detected signal at sulfur dioxide Raman scattering wavelength. The nitrogen dioxide fluorescence contribution can be measured by two methods. The first is to convert the nitrogen dioxide fluorescence intensity which is measured at a different wavelength from sulfur dioxide Raman line into the one at sulfur dioxide Raman line. The second is to convert the detected signal intensity, which is obtained when the range gate is set just behind the plume, into the one obtained at the range of the plume using the difference of the time dependence between sulfur dioxide Raman scattering and nitrogen dioxide fluorescence. Nitrogen dioxide fluorescence has lifetime of about 300nS, while Raman scattering has none. By either of the two methods, the contribution of nitrogen dioxide fluorescence is determined. Then, we can measure the nitrogen dioxide and sulfur dioxide concentration.The minimum detectable concentration and the experimental results of the remote sensing of sulfur dioxide and nitrogen dioxide in stack plume will be discussed in detail.

Nakahara, S.↗

Brillouin Sensing with PCA, and PCA-Based Neural Networks for Efficient Temperature Monitoring

This work explores peak estimation techniques in Brillouin Optical Time Domain Analysis (BOTDA), emphasizing both accuracy and efficiency. Euclidean distance measurement method is applied to principal components derived from Brillouin Gain Spectrum data. It offers a major speed advantage being 180 170 times faster than traditional curve fitting methods such as Lorentzian curve fitting, while maintaining similar accuracy. Additionally, a PCA- based neural network model shows significant reduction of peak estimation time compared to Lorentzian fitting. Results show Brillouin frequency shift errors lie under 0.75 MHz in both Euclidean distance-based and neural network-based methods, both of which utilize PCA components. For large data sets and long length fibers, PCA- assisted neural network for peak estimation would be an efficient solution.

Distributed optical fiber sensing↗

Location Identifiers, Metadata, and Map for Field Measurements at the East-Taylor Watershed Community Observatory, Colorado, USA (Version 3.3)

This dataset contains identifiers, metadata, and a map of the locations where field measurements have been conducted at the East-Taylor Watershed Community Observatory located in the Upper Colorado River Basin, United States. This is version 3.3 of the dataset and replaces the prior version 3.2 (see below for details on changes between the versions). Dataset description: The East River-Taylor Watershed is the primary field site of the Watershed Function Scientific Focus Area (WFSFA) and the Rocky Mountain Biological Laboratory. Researchers from several institutions generate highly diverse hydrological, biogeochemical, climate, vegetation, geological, remote sensing, and model data at the East-Taylor Watershed in collaboration with the WFSFA. Thus, the purpose of this dataset is to maintain an inventory of the field locations and instrumentation to provide information on the field activities in the East-Taylor Watershed and coordinate data collected across different locations, researchers, and institutions. The dataset contains (1) a README file with information on the various files, (2) three csv files describing the metadata collected for each surface point location, plot and region registered with the WFSFA, (3) csv files with metadata and contact information for each surface point location registered with the WFSFA, (4) a csv file with with metadata and contact information for plots, (5) a csv file with metadata for geographic regions and sub-regions within the watershed, (6) a compiled xlsx file with all the data and metadata which can be opened in Microsoft Excel, (7) a kml map of the locations plotted in the watershed which can be opened in Google Earth, (8) a jpg image of the kml map which can be viewed in any photo viewer, and (9) a zipped file with the registration templates used by the SFA team to collect location metadata. The zipped template file contains two csv files with the blank templates (point and plot), two csv files with instructions for filling out the location templates, and one compiled xlsx file with the instructions and blank templates together. Additionally, the templates in the xlsx include drop down validation for any controlled metadata fields. Persistent location identifiers (Location_ID) are determined by the WFSFA data management team and are used to track data and samples across locations. Dataset uses: This location metadata is used to update the Watershed SFA’s publicly accessible Field Information Portal (an interactive field sampling metadata exploration tool; https://wfsfa-data.lbl.gov/watershed/), the kml map file included in this dataset, and other data management tools internal to the Watershed SFA team. Version Information: The latest version of this dataset publication is version 3.3. This version contains 167 new point locations, 1 new plot, and 2 new geographic regions. Overall, there are a total of 1439 point locations, 75 plots, and 54 geographic regions. Additionally, the kml map of locations and image now includes two boundaries (Upper Ohio Creek (UO) and Carbon Creek (CA)) outside of the East River watershed (USGS HUC-10) and accompanying stream network that represents areas of focus. Refer to methods for further details on the version history. This dataset will be updated on a periodic basis with new measurement location information. Researchers interested in having their East-Taylor Watershed measurement locations added to this list should reach out to the WFSFA data management team at wfsfa-data@googlegroups.com. Acknowledgments: Please cite this dataset if using any of the location metadata in other publications or derived products. If using the location metadata for the 2018 NEON hyperspectral campaign, additionally cite Chadwick et al. (2020). doi:10.15485/1618130. This work was supported by the Watershed Function Science Focus Area at Lawrence Berkeley National Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-05CH11231. Part of this work was performed at SLAC Accelerator Laboratory funded by the US Department of Energy, Office of Science, Biological and Environmental Research under Contract No. DE-AC02-76SF00515.

2018 NEON and 2025 CHESS Campaigns↗