Engineering Papers⌕ Search

SEARCH · Engineering Papers

Results for “Measurement uncertainty”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 235 records · Page 13

Atmospheric methyl iodide /CH3I/

It is found that atmospheric concentrations of CH3I are not greater than about 3 pptv over most of the earth's surface and drop to less than half this value above the boundary layer, suggesting that the compound is not likely to play such important roles, on a global scale, as the destruction of tropospheric O3 and free radicals and the increasing of the NO2/NO ratio and hydroxyl radical densities. It is hypothesized that a large portion of the global CH3I comes from oceanic regions of high biomass productivity, where the compound may play a key role in local atmospheric chemistry. Attention is given to CH3I measurement uncertainties with regard to global distribution, sources, and sinks.

Rasmussen, R. A.↗

El Chichon eruption cloud - Comparison of lidar and optical thickness measurements for October 1982

Sun photometer and lidar backscatter measurements of the El Chichon volcanic cloud were obtained during an airborne latitude survey. The observations were collected between 46 deg N and 46 deg S from Oct. 19-Nov. 7, 1982. Comparisons between these data sets have been performed. An aerosol optical model was developed for the conversion of the lidar measurements to optical thickness values using numerical aerosol size distribution data and index of refraction information collected with coordinated dustsonde balloon flights. The derived lidar optical thickness values were found to agree with the sun photometer optical thickness values within measurement uncertainties. The lidar derived values ranged from 0.16 at the equator to 0.03 at 30 deg S latitude. Peak values were concentrated between 35 deg N and 10 deg S.

Swissler, T. J.↗

A technique for dynamically calibrating pressure transducers at cryogenic temperatures

A technique was developed for the calibration of dynamic pressure transducers at cryogenic temperatures. The calibration system utilizes an 8.9 Newton peak thrust shaker which oscillates a helium-filled bellows to generate a sinusoidal dynamic pressure to calibrate transducers immersed in a cryogenic environment. The system has a dynamic pressure measurement uncertainty of approximately 11% and is capable of producing peak-to-peak dynamic pressure amplitudes of 1.4 kPa over a frequency range of 40 to 100 hertz and a temperature range of 100 to 300 K. It provides an unprecedented capability of both static and dynamic calibration of pressure transducers from ambient to cryogenic temperature.

Gibbens, B. V.↗

Analysis of thermoelectric properties of high-temperature complex alloys of nickel-base, iron-base and cobalt-base groups

The thermoelectric properties alloys of the nickel-base, iron-base, and cobalt-base groups containing from 1% to 25% 106 chromium were compared and correlated with the following material characteristics: atomic percent of the principle alloy constituent; ratio of concentration of two constituents; alloy physical property (electrical resistivity); alloy phase structure (percent precipitate or percent hardener content); alloy electronic structure (electron concentration). For solid-solution-type alloys the most consistent correlation was obtained with electron concentration, for precipitation-hardenable alloys of the nickel-base superalloy group, the thermoelectric potential correlated with hardener content in the alloy structure. For solid-solution-type alloys, no problems were found with thermoelectric stability to 1000; for precipitation-hardenable alloys, thermoelectric stability was dependent on phase stability. The effects of the compositional range of alloy constituents on temperature measurement uncertainty are discussed.

Holanda, R.↗

Beta systems error analysis

The atmospheric backscatter coefficient, beta, measured with an airborne CO Laser Doppler Velocimeter (LDV) system operating in a continuous wave, focussed model is discussed. The Single Particle Mode (SPM) algorithm, was developed from concept through analysis of an extensive amount of data obtained with the system on board a NASA aircraft. The SPM algorithm is intended to be employed in situations where one particle at a time appears in the sensitive volume of the LDV. In addition to giving the backscatter coefficient, the SPM algorithm also produces as intermediate results the aerosol density and the aerosol backscatter cross section distribution. A second method, which measures only the atmospheric backscatter coefficient, is called the Volume Mode (VM) and was simultaneously employed. The results of these two methods differed by slightly less than an order of magnitude. The measurement uncertainties or other errors in the results of the two methods are examined.

Source record↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

Thermal detectors as X-ray spectrometers

Sensitive thermal detectors should be useful for measuring very small energy pulses, such as those produced by the absorption of X-ray photons. The measurement uncertainty can be very small, making the technique promising for high resolution nondispersive X-ray spectroscopy. The limits to the energy resolution of such thermal detectors are derived and used to find the resolution to be expected for a detector suitable for X-ray spectroscopy in the 100 eV to 10,000 eV range. If there is no noise in the thermalization of the X-ray, resolution better than 1 eV full width at half maximum is possible for detectors operating at 0.1 K. Energy loss in the conversion of the photon energy to heat is a potential problem. The loss mechanisms may include emission of photons or electrons, or the trapping of energy in long lived metastable states. Fluctuations in the phonon spectrum could also limit the resolution if phonon relaxation times are very long. Conceptual solutions are given for each of these possible problems.

Moseley, S. H.↗

A sequential decoding performance analysis for International Comet Explorer

The effect of a noisy reference carrier on the performance of International Comet Explorer (ICE) Sequential decoder is analyzed. Ideal reference models for frame deletion probability are given for the Telemetry Processing Assembly (TPA) and the Linkabit (LS4815) sequential decoders. Based on these ideal reference models the deletion probability in the presence of noisy reference carrier is computed for both the high and the low data rate cases. A medium data rate performance model is then derived using an interpolation method. The derived medium rate performance model depends on the phase locked loop bandwidth-integration time product. Results are obtained for frame length 1024 bits, data bit rates of 1024 bps and 512 bps, modulation index of 60 deg, and threshold loop bandwidths of 10 Hz and 3 Hz. The medium rate model agrees with experimental data to within measurement uncertainty. For the 10 Hz loop bandwidth and modulation index of 60 deg at frame deletion rate of 0.0001, the required total received power to noise ratio is 36 dB. The analysis given is general and applicable to any sequential decoder, provided that the ideal reference model of the decoder is available.

Divsalar, D.↗

Recent experience in seeding transonic/supersonic flows at AEDC

The laser velocimeter has been utilized for several years at the Arnold Engineering and Development Center (AEDC) as a flow diagnostics tool. Most applications, following the initial proof-of-concept experiments, have involved relatively complex unknown flow fields in which the more conventional, intrusive techniques had either not been attempted or had yielded unsatisfactory results. A blunt-base nozzle-afterbody base flow study is discussed as a respresentative example of such applications. A wide variety of problems have been encountered during these tests, many of which have proven to be closely related to the size and/or size distribution of the seeding material within the fluid. Resulting measurement uncertainties could often not be conclusively resolved because of the unknown nature of the flow field. The other experiments listed were conducted to provide known aerodynamic conditions for comparison with the velocimeter results.

Heltsley, F. L.↗

Quantitative void characterization in structural ceramics using scanning laser acoustic microscopy

The ability of scanning laser acoustic microscopy (SLAM) to characterize artificially seeded voids in sintered silicon nitride structural ceramic specimens was investigated. Using trigonometric relationships and Airy's diffraction theory, predictions of internal void depth and size were obtained from acoustic diffraction patterns produced by the voids. Agreement was observed between actual and predicted void depths. However, predicted void diameters were generally much greater than actual diameters. Precise diameter predictions are difficult to obtain due to measurement uncertainty and the limitations of 100 MHz SLAM applied to typical ceramic specimens.

Roth, D. J.↗

Correcting observed stellar Lyman alpha profiles for the effects of interstellar absorption and geocoronal emission

Techniques to compensate for interstellar absorption and geocoronal emission in IUE studies of late stars atmospheres were developed. Thus it is possible to determine the Lyman alpha flux from nearby cool stars using the low-resolution spectra in the IUE archives. The accuracy of such a procedure depends fundamentally upon the assumptions regarding the shape of the intrinsic profile and the density and velocity structure of the local interstellar medium, not upon measurement uncertainties of the low-resolution spectra. Geocoronal emission and saturated spectra are fatal only to a one-dimensional spectral analysis. When both the spatial and the spectral dimensions are considered, the observed Lyman alpha flux can be recovered.

Neff, J. E.↗

An analysis on the shapes of ultraviolet extinction curves. I - The 2175 A bump

IUE data are used to investigate the properties of the 2175 A interstellar extinction bump toward 45 reddened Milky Way stars. Using analytic fitting functions, parameters are derived which describe the central position, FWHM, and strength of the bump. The bump position is very stable, with an extreme deviation which is still significantly larger than the measurement uncertainty, indicating true variability. The bump FWHM has a large range of intrinsic values, 0.77/micron to 1.25/micron. The normalized bump strength varies by more than a factor of three. There are no convincing correlations among the three bump parameters, but the width of the bump is strongly correlated with the dust grain environments. Dense quiescent regions yield broad bumps, while diffuse interstellar medium and regions of recent star formation yield narrower bumps. The absence of any correlation between bump width and central position argues strongly against graphite grains in the size range prescribed by the Mathis, Rumpl, and Nordsieck (1977) model as carriers of the bump.

Fitzpatrick, E. L.↗

Models of the structure of the atmosphere of Venus from the surface to 100 kilometers altitude

From a critical comparison and synthesis of data from the four Pioneer Venus Probes, the Pioneer Venus Orbiter, and the Venera 10, 12, and 13 landers, models of the lower and middle atmosphere of Venus are derived. The models are consistent with the data sets within the measurement uncertainties and established variability of the atmosphere. The models represent the observed variations of state properties with latitude, and preserve the observed static stability. The rationale and the approach used to derive the models are discussed, and the remaining uncertainties are estimated.

Seiff, A.↗

Validation of SAGE II aerosol measurements by comparison with correlative sensors

The SAGE II limb-scanning radiometer carried on the Earth Radiation Budget Satellite functions at wavelengths of 0.385, 0.45, 0.525, and 1.02 microns to identify vertical profiles of aerosol density by atmospheric extinction measurements from cloud tops upward. The data are being validated by correlating the satellite data with data gathered with, e.g., lidar, sunphotometer, and dustsonde instruments. Work thus far has shown that the 1 micron measurements from the ground and satellite are highly correlated and are therefore accurate to within measurement uncertainty.

Swissler, T. J.↗

Quantitative void characterization in structural ceramics by use of scanning laser acoustic microscopy

The ability of scanning laser acoustic microscopy (SLAM) to characterize artificially seeded voids in sintered silicon nitride structural ceramic specimens was investigated. Using trigonometric relationships and Airy's diffraction theory, predictions of internal void depth and size were obtained from acoustic diffraction patterns produced by the voids. Agreement was observed between actual and predicted void depths. However, predicted void diameters were generally much greater than actual diameters. Precise diameter predictions are difficult to obtain due to measurement uncertainty and the limitations of 100 MHz SLAM applied to typical ceramic specimens.

Roth, D. J.↗

Flaw characterization in structural ceramics using scanning laser acoustic microscopy

The ability of scanning laser acoustic microscopy (SLAM) to characterize artifically seeded voids in sintered silicon nitride structural ceramic specimens was investigated. The voids ranged from 20 to 430 microns in diameter and were embedded up to 2 mm beneath the surface of the specimens. Probability of detection was determined as a function of void depth and size. Trigonometric relationships and Airy's diffraction theory were used to obtain predictions of void depth and size from acoustic diffraction patterns produced by the voids. Agreement was observed between actual and predicted void depths. However, predicted void diameters were generally much greater than actual diameters. Precise diameter predictions are difficult to obtain because of measurement uncertainty and the limitations of the 100 MHz SLAM applied to typical ceramic specimens.

Roth, Don J.↗

Ultraviolet extinction differences within NGC 6530

Ultraviolet extinction curves are presented for 14 stars in the very young cluster NGC 6530. The variation of the short-wavelength extinction is consistent with that expected based on random errors alone, although the weakest extinction is found only toward the cluster center. Variations significantly larger than the measurement uncertainty are found in the area, width, and central peak position of the 2200 A extinction bump. These parameters are largest in the cluster center and decrease systematically outwards. Physical processes capable of modifying the grains in the H II region containing the cluster are discussed.

Boggs, Don↗

An inter-comparison of surface energy flux measurement systems used during FIFE, 1987

During the first International Satellite Land Surface Climatology Program Field Experiment (FIFE-87), surface energy fluxes were measured at 22 flux sites by nine groups of scientists using different measuring systems. A rover Bowen ratio station was taken to nearly all the flux stations to serve as a reference for estimating the instrument related differences. The rover system was installed within a few meters from the host instrument of a site. Net radiation, Bowen ratio, and latent heat fluxes were compared between the rover and the host for the stations visited. Linear regression analysis was used to examine the relationship between rover measurements and host measurements. These inter-comparisons are needed to examine the influence of instrumentation on measurement uncertainty. Highly significant effects of instrument type were detected from these comparisons. Instruments of the same type showed average differences of less than 5 percent for net radiation, 10 percent for Bowen ratio, and 6 percent for latent heat flux. The corresponding average differences for different types of instruments can be up to 10, 30, and 20 percent respectively. The Didcot net radiometer gave higher net radiation while the Swissteco type showed lower values, as compared to the corrected REBS model. The 4-way components methed and the Thornswaite type give similar values to the REBS. The SERBS type Bowen ratio systems exhibit slightly lower Bowen ratios and thus higher latent heat fluxes, compared to the AZET systems. Eddy correlation systems showed slightly lower latent heat flux in comparison to the Bowen ratio systems.

Nie, D.↗